Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 11/2016

01.11.2016 | Original Article

Design of a video capsule endoscopy system with low-power ASIC for monitoring gastrointestinal tract

verfasst von: Gang Liu, Guozheng Yan, Bingquan Zhu, Li Lu

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 11/2016

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In recent years, wireless capsule endoscopy (WCE) has been a state-of-the-art tool to examine disorders of the human gastrointestinal tract painlessly. However, system miniaturization, enhancement of the image-data transfer rate and power consumption reduction for the capsule are still key challenges. In this paper, a video capsule endoscopy system with a low-power controlling and processing application-specific integrated circuit (ASIC) is designed and fabricated. In the design, these challenges are resolved by employing a microimage sensor, a novel radio frequency transmitter with an on–off keying modulation rate of 20 Mbps, and an ASIC structure that includes a clock management module, a power-efficient image compression module and a power management unit. An ASIC-based prototype capsule, which measures Φ11 mm × 25 mm, has been developed here. Test results show that the designed ASIC consumes much less power than most of the other WCE systems and that its total power consumption per frame is the least. The image compression module can realize high near-lossless compression rate (3.69) and high image quality (46.2 dB). The proposed system supports multi-spectral imaging, including white light imaging and autofluorescence imaging, at a maximum frame rate of 24 fps and with a resolution of 400 × 400. Tests and in vivo trials in pigs have proved the feasibility of the entire system, but further improvements in capsule control and compression performance inside the ASIC are needed in the future.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Alonso O, Freixas L, Dieguez A (2009) Advancing towards smart endoscopy with specific electronics to enable locomotion and focusing capabilities in a wireless endoscopic capsule robot. In: BioCAS 2009, IEEE Conference on, pp 213–216 Alonso O, Freixas L, Dieguez A (2009) Advancing towards smart endoscopy with specific electronics to enable locomotion and focusing capabilities in a wireless endoscopic capsule robot. In: BioCAS 2009, IEEE Conference on, pp 213–216
2.
Zurück zum Zitat Basar MR, Malek F, Juni KM et al (2012) Ingestible wireless capsule technology: a review of development and future indication. Int J Antennas Propag. doi:10.1155/2012/807165 Basar MR, Malek F, Juni KM et al (2012) Ingestible wireless capsule technology: a review of development and future indication. Int J Antennas Propag. doi:10.​1155/​2012/​807165
3.
Zurück zum Zitat Basar MR, Malek FI, Mohd M et al (2013) A novel, high-speed image transmitter for wireless capsule endoscopy. Prog Electromagn Res 137:129–147CrossRef Basar MR, Malek FI, Mohd M et al (2013) A novel, high-speed image transmitter for wireless capsule endoscopy. Prog Electromagn Res 137:129–147CrossRef
4.
Zurück zum Zitat Basar MR, Malek F, Juni KM et al (2013) The use of a human body model to determine the variation of path losses in the human body channel in wireless capsule endoscopy. Prog Electromagn Res 133:495–513CrossRef Basar MR, Malek F, Juni KM et al (2013) The use of a human body model to determine the variation of path losses in the human body channel in wireless capsule endoscopy. Prog Electromagn Res 133:495–513CrossRef
5.
Zurück zum Zitat Cavallotti C, Merlino P, Vatteroni M et al (2011) An FPGA-based versatile development system for endoscopic capsule design optimization. Sens Actuators, A 172:301–307CrossRef Cavallotti C, Merlino P, Vatteroni M et al (2011) An FPGA-based versatile development system for endoscopic capsule design optimization. Sens Actuators, A 172:301–307CrossRef
6.
Zurück zum Zitat Chen X, Zhang X, Zhang L et al (2009) A wireless capsule endoscope system with low power controlling and processing ASIC. IEEE Trans Biomed Circuits Syst 3:11–22CrossRef Chen X, Zhang X, Zhang L et al (2009) A wireless capsule endoscope system with low power controlling and processing ASIC. IEEE Trans Biomed Circuits Syst 3:11–22CrossRef
7.
Zurück zum Zitat Cheng C, Liu Z, Hu C, Meng MQ (2010) A novel wireless capsule endoscope with JPEG compression engine. In: Automation and Logistics, IEEE Conference on, pp 553–558 Cheng C, Liu Z, Hu C, Meng MQ (2010) A novel wireless capsule endoscope with JPEG compression engine. In: Automation and Logistics, IEEE Conference on, pp 553–558
8.
Zurück zum Zitat Ciuti G, Menciassi A, Dario P (2011) Capsule endoscopy: from current achievements to open challenges. IEEE Rev Biomed Eng 4:59–72CrossRefPubMed Ciuti G, Menciassi A, Dario P (2011) Capsule endoscopy: from current achievements to open challenges. IEEE Rev Biomed Eng 4:59–72CrossRefPubMed
9.
Zurück zum Zitat Eom K, Jeong J, Lee TH et al (2014) A wireless power transmission system for implantable devices in freely moving rodents. Med Biol Eng Compu 52:639–651CrossRef Eom K, Jeong J, Lee TH et al (2014) A wireless power transmission system for implantable devices in freely moving rodents. Med Biol Eng Compu 52:639–651CrossRef
10.
Zurück zum Zitat Gholamzadeh B, Nabovati H (2008) Concepts for designing low power wireless sensor network. World Acad Sci Eng Technol 45:559–565 Gholamzadeh B, Nabovati H (2008) Concepts for designing low power wireless sensor network. World Acad Sci Eng Technol 45:559–565
14.
Zurück zum Zitat Iddan G, Meron G, Glukhovsky A, Swain P (2000) Wireless capsule endoscopy. Nature 405:417–418CrossRefPubMed Iddan G, Meron G, Glukhovsky A, Swain P (2000) Wireless capsule endoscopy. Nature 405:417–418CrossRefPubMed
15.
Zurück zum Zitat Karargyris A, Koulaouzidis A (2015) OdoCapsule: next-generation wireless capsule endoscopy with accurate lesion localization and video stabilization capabilities. IEEE Trans Biomed Eng 62(1):352–360CrossRefPubMed Karargyris A, Koulaouzidis A (2015) OdoCapsule: next-generation wireless capsule endoscopy with accurate lesion localization and video stabilization capabilities. IEEE Trans Biomed Eng 62(1):352–360CrossRefPubMed
16.
Zurück zum Zitat Kim K, Yun S, Lee S, Nam S, Yoon YJ, Cheon C (2012) A design of a high-speed and high-efficiency capsule endoscopy system. IEEE Trans Biomed Eng 59:1005–1011CrossRefPubMed Kim K, Yun S, Lee S, Nam S, Yoon YJ, Cheon C (2012) A design of a high-speed and high-efficiency capsule endoscopy system. IEEE Trans Biomed Eng 59:1005–1011CrossRefPubMed
17.
Zurück zum Zitat Koulaouzidis A, Iakovidis DK, Karargyris A et al (2015) Wireless endoscopy in 2020: will it still be a capsule? World J Gastroenterol 21(17):5119CrossRefPubMedPubMedCentral Koulaouzidis A, Iakovidis DK, Karargyris A et al (2015) Wireless endoscopy in 2020: will it still be a capsule? World J Gastroenterol 21(17):5119CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Metzger YC, Adler SN, Shitrit AB et al (2009) Comparison of a new PillCam™ SB2 video capsule versus the standard PillCam™ SB for detection of small bowel disease. Rep Med Imaging 2(1):7–11 Metzger YC, Adler SN, Shitrit AB et al (2009) Comparison of a new PillCam™ SB2 video capsule versus the standard PillCam™ SB for detection of small bowel disease. Rep Med Imaging 2(1):7–11
19.
Zurück zum Zitat Miaou S, Chen S (2005) A data compression method for long sequence of wireless capsule endoscope images. J Med Biol Eng 25:107–116 Miaou S, Chen S (2005) A data compression method for long sequence of wireless capsule endoscope images. J Med Biol Eng 25:107–116
20.
Zurück zum Zitat Neumann H, Fry LC, Nägel A, Neurath MF (2014) Wireless capsule endoscopy of the small intestine: a review with future directions. Curr Opin Gastroenterol 30:463–471CrossRefPubMed Neumann H, Fry LC, Nägel A, Neurath MF (2014) Wireless capsule endoscopy of the small intestine: a review with future directions. Curr Opin Gastroenterol 30:463–471CrossRefPubMed
22.
Zurück zum Zitat Pan G, Xin W, Yan G, Chen J (2011) A video wireless capsule endoscopy system powered wirelessly: design, analysis and experiment. Meas Sci Technol 22:065802CrossRef Pan G, Xin W, Yan G, Chen J (2011) A video wireless capsule endoscopy system powered wirelessly: design, analysis and experiment. Meas Sci Technol 22:065802CrossRef
23.
Zurück zum Zitat Poomrittigul S, Ogawa M, Iwahashi M, Kiya H (2013) Reversible color transform for Bayer color filter array images. APSIPA Trans Signal Inform Process 2:e5CrossRef Poomrittigul S, Ogawa M, Iwahashi M, Kiya H (2013) Reversible color transform for Bayer color filter array images. APSIPA Trans Signal Inform Process 2:e5CrossRef
24.
Zurück zum Zitat Rasouli M, Kencana AP, Huynh VA et al (2011) Ingestible wireless capsules for enhanced diagnostic inspection of gastrointestinal tract. Front Mech Eng 6:40–44 Rasouli M, Kencana AP, Huynh VA et al (2011) Ingestible wireless capsules for enhanced diagnostic inspection of gastrointestinal tract. Front Mech Eng 6:40–44
25.
Zurück zum Zitat Ryu M, Kim JD, Chin HU et al (2007) Three-dimensional power receiver for in vivo robotic capsules. Med Biol Eng Compu 45:997–1002CrossRef Ryu M, Kim JD, Chin HU et al (2007) Three-dimensional power receiver for in vivo robotic capsules. Med Biol Eng Compu 45:997–1002CrossRef
26.
Zurück zum Zitat Tareq TH, Shrestha R, Wahid KA, Babyn P (2015) Design of a smart-device and FPGA based wireless capsule endoscopic system. Sens Actuators, A 221:77–87CrossRef Tareq TH, Shrestha R, Wahid KA, Babyn P (2015) Design of a smart-device and FPGA based wireless capsule endoscopic system. Sens Actuators, A 221:77–87CrossRef
27.
Zurück zum Zitat Turcza P, Duplaga M (2011) Low power FPGA-based image processing core for wireless capsule endoscopy. Sens Actuators, A 172:552–560CrossRef Turcza P, Duplaga M (2011) Low power FPGA-based image processing core for wireless capsule endoscopy. Sens Actuators, A 172:552–560CrossRef
28.
Zurück zum Zitat Van GA (2014) Wireless capsule endoscopy of the large intestine: a review with future projections. Curr Opin Gastroenterol 30:472–476CrossRef Van GA (2014) Wireless capsule endoscopy of the large intestine: a review with future projections. Curr Opin Gastroenterol 30:472–476CrossRef
29.
Zurück zum Zitat Vatteroni M, Covi D, Cavallotti C et al (2010) Smart optical CMOS sensor for endoluminal applications. Sens Actuators, A 162:297–303CrossRef Vatteroni M, Covi D, Cavallotti C et al (2010) Smart optical CMOS sensor for endoluminal applications. Sens Actuators, A 162:297–303CrossRef
30.
Zurück zum Zitat Wang A, Banerjee S, Barth BA et al (2013) Wireless capsule endoscopy. Gastrointest Endosc 78:805–815CrossRefPubMed Wang A, Banerjee S, Barth BA et al (2013) Wireless capsule endoscopy. Gastrointest Endosc 78:805–815CrossRefPubMed
31.
Zurück zum Zitat Woo SH, Cho JH (2010) Telemetry system for slow wave measurement from the small bowel. Med Biol Eng Compu 48:277–283CrossRef Woo SH, Cho JH (2010) Telemetry system for slow wave measurement from the small bowel. Med Biol Eng Compu 48:277–283CrossRef
32.
Zurück zum Zitat Xie X, Li G, Wang Z (2006) A low-complexity and high-quality image compression method for digital cameras. ETRI J 28:260–263CrossRef Xie X, Li G, Wang Z (2006) A low-complexity and high-quality image compression method for digital cameras. ETRI J 28:260–263CrossRef
33.
Zurück zum Zitat Zhang N, Wu X (2006) Lossless compression of color mosaic images. IEEE Trans Image Process 15:1379–1388CrossRefPubMed Zhang N, Wu X (2006) Lossless compression of color mosaic images. IEEE Trans Image Process 15:1379–1388CrossRefPubMed
34.
Zurück zum Zitat Zhu B, Yan G, Liu G, Shi Y (2014) Design of a dual-head video capsule endoscopy system based on wireless power transmission technology. J Med Biol Eng. doi:10.5405/jmbe.1841 Zhu B, Yan G, Liu G, Shi Y (2014) Design of a dual-head video capsule endoscopy system based on wireless power transmission technology. J Med Biol Eng. doi:10.​5405/​jmbe.​1841
Metadaten
Titel
Design of a video capsule endoscopy system with low-power ASIC for monitoring gastrointestinal tract
verfasst von
Gang Liu
Guozheng Yan
Bingquan Zhu
Li Lu
Publikationsdatum
01.11.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 11/2016
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-016-1472-2

Weitere Artikel der Ausgabe 11/2016

Medical & Biological Engineering & Computing 11/2016 Zur Ausgabe

Premium Partner