Skip to main content
main-content

Tipp

Weitere Artikel dieser Ausgabe durch Wischen aufrufen

01.06.2011 | Technical Paper | Ausgabe 5-7/2011

Microsystem Technologies 5-7/2011

Driving mechanisms of CM-scaled PDMS boats of respective close and open reservoirs

Zeitschrift:
Microsystem Technologies > Ausgabe 5-7/2011
Autoren:
Xinchuan Liu, Hao Li, Lei Qiao, Cheng Luo

Abstract

A floating solid object may have a spontaneous motion on a water surface when a liquid, which has a surface tension lower than water, exits the solid object and has contact with water. This motion may be induced due to the difference between surface tensions of water and the liquid. In order to interpret this motion, it is important to know how the liquid exits the solid object. In this article, we reported in situ observation of exchange processes of water and isopropyl alcohol (IPA) inside both close and open reservoirs of cm-scaled polydimethylsiloxane (PDMS) boats. Based on this observation and force analysis, we interpreted driving mechanisms of these boats. We found that the exchange processes may be different in the PDMS boats of respective close and open reservoirs. The PDMS boat of a close reservoir might have a bubble trapped in its reservoir during the motion. This bubble slowed down the exiting process of the IPA from the reservoir, made the motion last longer, and enabled the boat to have a longer travel distance. Also, such a boat had gurgling-like motions (i.e., approximately periodic motions of deceleration and acceleration) after the majority of the IPA had exited the reservoir. The speeds of this boat had an order of 1 cm/s. On the other hand, neither bubbles nor gurgling-like phenomena were found in the motions of the PDMS boat of an open reservoir. The speeds of this boat were in the order of 1 cm/s as well. In addition, based on observed exiting processes of the IPA and experimentally determined speed-time relationships, we also set up a simple model to find force–time relationships. Furthermore, we investigated the exiting process when the open reservoir of the cm-scaled PDMS boat was shallow. We found that, depending on the values of the height difference, h, between the bottom of the reservoir and the water surface outside the reservoir, three different phenomena might appear: (1) if h ≤ 1.33 mm, then the reservoir was empty at the end of the test and no water flowed into the reservoir during the test; (2) if 1.3 mm < h ≤ 2.3 mm, then the reservoir was empty at the end of the test while water flowed into the reservoir during the test; and (3) if 2.3 mm < h ≤ 3.0 mm, then the reservoir was filled by water at the end of the test. The difference in the filling results was induced by the interplay among Marangoni effect, free convection, and recovery of a hollow spot by surrounding water. The corresponding findings interpreted the exiting process of the IPA observed in the open reservoir of a mm-scaled SU-8 boat that we have previously developed, and also explained the filling result in the open reservoir of a PDMS boat.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

Sie möchten Zugang zu diesem Inhalt erhalten? Dann informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit dem Kombi-Abo erhalten Sie vollen Zugriff auf über 1,8 Mio. Dokumente aus mehr als 61.000 Fachbüchern und rund 500 Fachzeitschriften aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Umwelt
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe

Testen Sie jetzt 30 Tage kostenlos.

Springer Professional "Technik"

Online-Abonnement

Mit dem Technik-Abo erhalten Sie Zugriff auf über 1 Mio. Dokumente aus mehr als 40.000 Fachbüchern und 300 Fachzeitschriften aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Umwelt
  • Maschinenbau + Werkstoffe

Testen Sie jetzt 30 Tage kostenlos.

Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 5-7/2011

Microsystem Technologies 5-7/2011 Zur Ausgabe

BranchenIndex Online

Die B2B-Firmensuche für Industrie und Wirtschaft: Kostenfrei in Firmenprofilen nach Lieferanten, Herstellern, Dienstleistern und Händlern recherchieren.

Whitepaper

- ANZEIGE -

Globales Erdungssystem in urbanen Kabelnetzen

Bedingt durch die Altersstruktur vieler Kabelverteilnetze mit der damit verbundenen verminderten Isolationsfestigkeit oder durch fortschreitenden Kabelausbau ist es immer häufiger erforderlich, anstelle der Resonanz-Sternpunktserdung alternative Konzepte für die Sternpunktsbehandlung umzusetzen. Die damit verbundenen Fehlerortungskonzepte bzw. die Erhöhung der Restströme im Erdschlussfall führen jedoch aufgrund der hohen Fehlerströme zu neuen Anforderungen an die Erdungs- und Fehlerstromrückleitungs-Systeme. Lesen Sie hier über die Auswirkung von leitfähigen Strukturen auf die Stromaufteilung sowie die Potentialverhältnisse in urbanen Kabelnetzen bei stromstarken Erdschlüssen. Jetzt gratis downloaden!

Bildnachweise