Skip to main content
Erschienen in: Fire Technology 2/2021

22.07.2020

Fire Resistance of Exterior Wall Assemblies for Housing and Small Buildings

verfasst von: Mohamed A. Sultan

Erschienen in: Fire Technology | Ausgabe 2/2021

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This paper presents the fire resistance results of 6 full-scale exterior wall assemblies study conducted at the National Research Council of Canada jointly with the North American construction industry and other Canadian government departments. The parameters investigated include: cavity insulation types (rock, glass and cellulose fibre) in exterior wall assemblies with oriented strand board sheathing; cavity insulation types (glass fibre and cellulose fibre) in exterior wall assemblies with Type X gypsum glass mat sheathing; and assemblies with different screw spacing of standard 400 mm o.c. and non-standard 200 mm o.c. for attaching the Type X gypsum board on the fire-exposed side and glass mat sheathing board on unexposed side to wood studs using glass fibre insulation in wall cavity. The impact of the investigated parameters on the fire resistance of exterior wall assemblies is discussed. Also, Further research recommendations on design changes to enhance the fire resistance of exterior wall assemblies are proposed. Results of the parameters studied showed that the effect of insulation types on the fire resistance of exterior wall assemblies with OSB sheathing can be considered significant when gypsum board on the fire-exposed side is attached to wood studs with screws spaced at 406 mm o.c., however, the effect insulation types on fire resistance when the gypsum board on fire-exposed side and gypsum glass mat sheathing are attached to wood studs with screw spaced at 203 mm o.c. can be considered insignificant. Also, results showed the use of non-standard screw spacing at 203 mm o.c. for attaching the gypsum board on the fire-exposed side increased the fire resistance by 37% compared to screw spacing at 406 mm o.c. Therefore, the effect of screw spacing on the fire resistance of exterior wall is significant.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat National Building Code of Canada, Edition (2015) National Research Council Canada, Ottawa, ON, Canada National Building Code of Canada, Edition (2015) National Research Council Canada, Ottawa, ON, Canada
2.
Zurück zum Zitat ASTM C1396/C1396M-17 (2017) Standard Specification for Gypsum Board. ASTM International, USA ASTM C1396/C1396M-17 (2017) Standard Specification for Gypsum Board. ASTM International, USA
3.
Zurück zum Zitat CAN/CSA O325-07 (2017), Construction sheathing. Canadian Standards Association, Mississauga, ON, Canada CAN/CSA O325-07 (2017), Construction sheathing. Canadian Standards Association, Mississauga, ON, Canada
4.
Zurück zum Zitat ASTM C1177/C1177M-17 (2017) Standard specification for glass mat gypsum substrate for use as sheathing. ASTM International, West Conshohocken, PA ASTM C1177/C1177M-17 (2017) Standard specification for glass mat gypsum substrate for use as sheathing. ASTM International, West Conshohocken, PA
5.
Zurück zum Zitat CSA O141-05 (2015) Softwood lumber. Canadian Standards Association, Mississauga, Canada CSA O141-05 (2015) Softwood lumber. Canadian Standards Association, Mississauga, Canada
6.
Zurück zum Zitat CAN/ULC-S702 (2014) Standard for mineral fibre thermal insulation for buildings. Underwriters Laboratories of Canada, Canada CAN/ULC-S702 (2014) Standard for mineral fibre thermal insulation for buildings. Underwriters Laboratories of Canada, Canada
7.
Zurück zum Zitat CAN/ULC-S703-09 (2009) Standard for cellulose fibre insulation (CFI) for buildings Reaffirmation of second edition. Underwriters’ Laboratories of Canada, Canada CAN/ULC-S703-09 (2009) Standard for cellulose fibre insulation (CFI) for buildings Reaffirmation of second edition. Underwriters’ Laboratories of Canada, Canada
8.
Zurück zum Zitat CAN/CSA-A82.31-M91 (1991) Gypsum board application. Canadian Standards Association, Mississauga, ON, Canada CAN/CSA-A82.31-M91 (1991) Gypsum board application. Canadian Standards Association, Mississauga, ON, Canada
9.
Zurück zum Zitat Bwalya AC, Sultan MA, Thomas JR (2007) Impact of board orientation on the fire performance of regular gypsum bard walls. In: Fire and materials conference proceedings, San Francisco, USA Bwalya AC, Sultan MA, Thomas JR (2007) Impact of board orientation on the fire performance of regular gypsum bard walls. In: Fire and materials conference proceedings, San Francisco, USA
10.
Zurück zum Zitat ULC Design No. W308 (2019) Loadbearing wall rating − 1 h, fire from one side only ULC Design No. W308 (2019) Loadbearing wall rating − 1 h, fire from one side only
11.
Zurück zum Zitat CAN/ULC-S101-14 (2014) Standard methods of fire endurance tests of building construction and materials (1960). Underwriters’ Laboratories of Canada CAN/ULC-S101-14 (2014) Standard methods of fire endurance tests of building construction and materials (1960). Underwriters’ Laboratories of Canada
12.
Zurück zum Zitat Sultan MA, Adelzadeh M (2019) Fire resistance performance of building assemblies—results of 13 full-scale wall assemblies tests. Research Report CONST-56340E, National Research Council Canada Sultan MA, Adelzadeh M (2019) Fire resistance performance of building assemblies—results of 13 full-scale wall assemblies tests. Research Report CONST-56340E, National Research Council Canada
13.
Zurück zum Zitat Shorter GW, Harmathy TZ. Fire research furnaces at the National Research Council Canada, Research Report 5732 Shorter GW, Harmathy TZ. Fire research furnaces at the National Research Council Canada, Research Report 5732
14.
Zurück zum Zitat Sultan MA, Adelzadeh M (2019) Fire resistance performance of building assemblies—results of 13 full-scale wall assemblies tests. In: Interflam Conference proceedings, London, UK Sultan MA, Adelzadeh M (2019) Fire resistance performance of building assemblies—results of 13 full-scale wall assemblies tests. In: Interflam Conference proceedings, London, UK
15.
Zurück zum Zitat ASTM E119 (2019) Standard test methods for fire tests of building construction and materials ASTM E119 (2019) Standard test methods for fire tests of building construction and materials
16.
Zurück zum Zitat Sultan MA, Lougheed GD (2002) Results of fire resistance tests on full-scale gypsum board wall assemblies. National Research Council Canada, IR No. 833 Sultan MA, Lougheed GD (2002) Results of fire resistance tests on full-scale gypsum board wall assemblies. National Research Council Canada, IR No. 833
Metadaten
Titel
Fire Resistance of Exterior Wall Assemblies for Housing and Small Buildings
verfasst von
Mohamed A. Sultan
Publikationsdatum
22.07.2020
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 2/2021
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-020-01015-8

Weitere Artikel der Ausgabe 2/2021

Fire Technology 2/2021 Zur Ausgabe