Abstract

The paper discusses the Forward Kinematic Model (FKM) of a special Spherical Parallel Manipulator (SPM). The special SPM is obtained by modifying one leg of a classic SPM. This new architecture eliminates the singularity from the workspace. The SPM is used as master device for medical tele-operation system. The FKM of the new SPM is calculated using the equation of spherical four-bar mechanism. A method to improve the FKM calculation using extra sensor is proposed in this paper.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Tobergte, A. et al.: The sigma.7 haptic interface for mirosurge: a new bi-manual surgical console. In: Proceedings of the IEEE/RSJ International Conference on Intelligent Robots and Systems, pp. 3023–3030, 25–30 Sept 2011 Tobergte, A. et al.: The sigma.7 haptic interface for mirosurge: a new bi-manual surgical console. In: Proceedings of the IEEE/RSJ International Conference on Intelligent Robots and Systems, pp. 3023–3030, 25–30 Sept 2011
2.
Zurück zum Zitat Ma, A.; Payandeh, S.: Analysis and experimentation of a 4-DOF haptic device. In: Haptic interfaces for virtual environment and teleoperator systems, symposium on haptics, pp. 351–356, 13–14 March 2008 Ma, A.; Payandeh, S.: Analysis and experimentation of a 4-DOF haptic device. In: Haptic interfaces for virtual environment and teleoperator systems, symposium on haptics, pp. 351–356, 13–14 March 2008
3.
Zurück zum Zitat Chaker, A., Mlika, A., Laribi, M.A., Romdhane, L., Zeghoul, S.: Synthesis of a spherical parallel manipulator for a dexterous medical task. Front. Mech. Eng. 7(2), 150–162 (2012)CrossRef Chaker, A., Mlika, A., Laribi, M.A., Romdhane, L., Zeghoul, S.: Synthesis of a spherical parallel manipulator for a dexterous medical task. Front. Mech. Eng. 7(2), 150–162 (2012)CrossRef
4.
Zurück zum Zitat Saafi, H., Laribi, M.A., Zeghloul, S.: Optimal design of a new Spherical Parallel Manipulator. In: 23rd International Conference on Robotics in Alpe-Adria-Danube region, Smolenice castle, Slovakia, 3–5 Sept 2013 Saafi, H., Laribi, M.A., Zeghloul, S.: Optimal design of a new Spherical Parallel Manipulator. In: 23rd International Conference on Robotics in Alpe-Adria-Danube region, Smolenice castle, Slovakia, 3–5 Sept 2013
5.
Zurück zum Zitat Bai, S., Hansen, M.R., Angeles, J.: A robust forward-displacement analysis of spherical parallel robots. Mech. Mach. Th. 44(12), 2204–2216 (2009)CrossRefMATH Bai, S., Hansen, M.R., Angeles, J.: A robust forward-displacement analysis of spherical parallel robots. Mech. Mach. Th. 44(12), 2204–2216 (2009)CrossRefMATH
6.
Zurück zum Zitat Saafi, H., Laribi, M. A., Zeghloul, S.: Improvement of the direct kinematic model of a haptic device for medical application in real time using an extra sensor. In: IEEE/RSJ International Conference on Intelligent Robots and Systems, pp. 1697–1702, 14–18 Sept 2014 Saafi, H., Laribi, M. A., Zeghloul, S.: Improvement of the direct kinematic model of a haptic device for medical application in real time using an extra sensor. In: IEEE/RSJ International Conference on Intelligent Robots and Systems, pp. 1697–1702, 14–18 Sept 2014
Metadaten
Titel
Forward Kinematic Model of a New Spherical Parallel Manipulator Used as a Master Device
verfasst von
H. Saafi
M. A. Laribi
M. Arsicault
S. Zeghloul
Copyright-Jahr
2015
DOI
https://doi.org/10.1007/978-3-319-18126-4_38

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.