Skip to main content
Erschienen in: Energy Systems 3/2022

06.03.2021 | Original Paper

High impedance fault detection based on current harmonic analysis using Chirp Z transform

verfasst von: Mojtaba Karimi, Navid Ghaffarzadeh

Erschienen in: Energy Systems | Ausgabe 3/2022

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

High Impedance Fault (HIF) is a problematic fault of feeders which its fault current is lower as compared to normal current in power system. Likewise, due to magnitude of impedance engaged in fault area and behavior of fault current is specific and not the same as the usual fault current profile which cannot be identified by standard relays. The HIF is created whenever a live conductor contacts with objects owning large impedance. The HIFs Signal has high index of similarity with some normal cases in feeders like Nonlinear loads (NL) waveform, or instant of switching of linear loads (LL), capacitor banks (CB) and full load transformers (FLT), which provided methods must distinguish them. So, the paper utilized a novel method with ability of recognizing HIF from all possible events in feeders with high accuracy. The Chirp Z Transform (CZT) has been applied to extract the features of HIF and/or other usual network events signal. It is possible to appropriately detect fault by low order harmonics of current signal extracted by means of CZT. Maximum discrepancy of detection is nearly 7 ms which is accurate enough. Also, absence of threshold values in algorithm makes it simple and can be used in each type of distribution and even transmission systems. Working in low-frequency harmonics is another advantage of this method because needs lower sampling frequency. The evaluated signals of HIF, NLs, LLs, capacitors and FLT are acquired by a simulated 13.8 kV distribution system in MATLAB/Simulink.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Wester, C.G.: High impedance fault detection on distribution system. IEEE Rural Electric Power Conf. 1–5 (1998) Wester, C.G.: High impedance fault detection on distribution system. IEEE Rural Electric Power Conf. 1–5 (1998)
2.
Zurück zum Zitat Lee, R., Bishop, M.: performance testing of the ratio ground relay on a four wire distribution feeder. IEEE Trans. Power App. And sys. 102, 2943–2949 (1983)CrossRef Lee, R., Bishop, M.: performance testing of the ratio ground relay on a four wire distribution feeder. IEEE Trans. Power App. And sys. 102, 2943–2949 (1983)CrossRef
3.
Zurück zum Zitat Sarlak, M., Shahtash, S.M.: High impedance faulted branch identification using magnetic field signature analysis. IEEE Trans. Power Delivery. 28(1), 67–74 (2013)CrossRef Sarlak, M., Shahtash, S.M.: High impedance faulted branch identification using magnetic field signature analysis. IEEE Trans. Power Delivery. 28(1), 67–74 (2013)CrossRef
4.
Zurück zum Zitat Gautam, S., Brahma, S.M.: Detection of high impedance fault in power distribution system using mathematical morphology. IEEE Trans. Power delivery. 28(2), 1226–1234 (2013)CrossRef Gautam, S., Brahma, S.M.: Detection of high impedance fault in power distribution system using mathematical morphology. IEEE Trans. Power delivery. 28(2), 1226–1234 (2013)CrossRef
5.
Zurück zum Zitat Snider, L.A., Yuen, Y.S.: ANN based relay algorithm for detection of high impedance fault. Neurocoputing. 23, 243–254 (1998)CrossRef Snider, L.A., Yuen, Y.S.: ANN based relay algorithm for detection of high impedance fault. Neurocoputing. 23, 243–254 (1998)CrossRef
6.
Zurück zum Zitat Eissa, M.M., Sowilam, G.M.A., Sharaf, A.M. (2006): A new protection detection technique for high impedance fault using neural network. Power Engineering IEEE Large Engineering Systems Conference. 146–151 Eissa, M.M., Sowilam, G.M.A., Sharaf, A.M. (2006): A new protection detection technique for high impedance fault using neural network. Power Engineering IEEE Large Engineering Systems Conference. 146–151
7.
Zurück zum Zitat Aziz, M.A., Hassan, M.M., Zahab, E.A.: High-impedance faults analysis in distribution networks using an adaptive neuro fuzzy inference system. Electric Power Compon. Syst. 40(11), 1300–1318 (2012)CrossRef Aziz, M.A., Hassan, M.M., Zahab, E.A.: High-impedance faults analysis in distribution networks using an adaptive neuro fuzzy inference system. Electric Power Compon. Syst. 40(11), 1300–1318 (2012)CrossRef
8.
Zurück zum Zitat Samantaray, S.R.: Ensemble decision trees for high impedance fault detection in power distribution network. Int. J. Elect. Power Energy Syst. 43(1), 1048–1055 (2012)CrossRef Samantaray, S.R.: Ensemble decision trees for high impedance fault detection in power distribution network. Int. J. Elect. Power Energy Syst. 43(1), 1048–1055 (2012)CrossRef
9.
Zurück zum Zitat David W Chan tat, Xia, Y.: A novel technique for high impedance fault Identification. IEEE Trans. Power Del. 13, 738–744 (1998) David W Chan tat, Xia, Y.: A novel technique for high impedance fault Identification. IEEE Trans. Power Del. 13, 738–744 (1998)
10.
Zurück zum Zitat Moravej, Z., Mortazavi, S.H., Shahrtash, S.M.: DT-CWT based event feature extraction for high impedance faults detection in distribution system. Int. Trans. Elec. Energy Syst. 25, 3288–3303 (2015)CrossRef Moravej, Z., Mortazavi, S.H., Shahrtash, S.M.: DT-CWT based event feature extraction for high impedance faults detection in distribution system. Int. Trans. Elec. Energy Syst. 25, 3288–3303 (2015)CrossRef
11.
Zurück zum Zitat Ghaderi, A., Mohammadpour, H., Ginn, H., Shin, Y.: High impedance fault detection in distribution network using time-frequency based algorithm. IEEE Trans. Power Deliv. 30(3), 1260–1268 (2014)CrossRef Ghaderi, A., Mohammadpour, H., Ginn, H., Shin, Y.: High impedance fault detection in distribution network using time-frequency based algorithm. IEEE Trans. Power Deliv. 30(3), 1260–1268 (2014)CrossRef
12.
Zurück zum Zitat Sarlak, M., Shahrtash, S.M., Arab-Khaburi, D.: Design and implementation of a systematically tunable high impedance fault relay. ISA Trans. 49(3), 358–368 (2010)CrossRef Sarlak, M., Shahrtash, S.M., Arab-Khaburi, D.: Design and implementation of a systematically tunable high impedance fault relay. ISA Trans. 49(3), 358–368 (2010)CrossRef
13.
Zurück zum Zitat Sedighi, A.R., Haghifam, M., Malik, O.P., Ghassemian, M.H.: High impedance fault detection based on wavelet transform and statistical pattern recognition. IEEE Trans. Power delivery. 20(4), 2414–2421 (2005)CrossRef Sedighi, A.R., Haghifam, M., Malik, O.P., Ghassemian, M.H.: High impedance fault detection based on wavelet transform and statistical pattern recognition. IEEE Trans. Power delivery. 20(4), 2414–2421 (2005)CrossRef
14.
Zurück zum Zitat Sahoo, S., Baran, M.E.: A method to detect high impedance faults indistribution feeders. in: T D Conference and Exposition. 2014 IEEE PES. 1–6 (2014). Sahoo, S., Baran, M.E.: A method to detect high impedance faults indistribution feeders. in: T D Conference and Exposition. 2014 IEEE PES. 1–6 (2014).
15.
Zurück zum Zitat Samantaray, S., Panigrahi, K., Dash, P.: High impedance fault detection in power distribution networks using time-frequency transform and probabilistic neural network. IET Gener. Transm. Distrib. 2(2), 261–270 (2008)CrossRef Samantaray, S., Panigrahi, K., Dash, P.: High impedance fault detection in power distribution networks using time-frequency transform and probabilistic neural network. IET Gener. Transm. Distrib. 2(2), 261–270 (2008)CrossRef
16.
Zurück zum Zitat Wang, X., et al.: High impedance fault detection method based on variational mode decomposition and teager-kaiser energy operators for distribution network. IEEE Trans. Smart Grid. 10(6), 6041–6054 (2019)CrossRef Wang, X., et al.: High impedance fault detection method based on variational mode decomposition and teager-kaiser energy operators for distribution network. IEEE Trans. Smart Grid. 10(6), 6041–6054 (2019)CrossRef
17.
Zurück zum Zitat Thomas, M.S., Bhaskar, N., Prakash, A.: Voltage based detection method for high impedance fault in a distribution system. J. Institution Eng. 97, 413–423 (2016) Thomas, M.S., Bhaskar, N., Prakash, A.: Voltage based detection method for high impedance fault in a distribution system. J. Institution Eng. 97, 413–423 (2016)
18.
Zurück zum Zitat Gadanayak, D.A., Mallick, R.K.: Interharmonics based high impedance fault detection in distribution systems using maximum overlap wavelet packet transform and a modified empirical mode decomposition. Int. J. Elect. Power Energy Syst. 112, 282–293 (2019)CrossRef Gadanayak, D.A., Mallick, R.K.: Interharmonics based high impedance fault detection in distribution systems using maximum overlap wavelet packet transform and a modified empirical mode decomposition. Int. J. Elect. Power Energy Syst. 112, 282–293 (2019)CrossRef
19.
Zurück zum Zitat Mortazavi, S.H., Moravej, Z., Shahrtash, S.M.: A hybrid method for arcing faults detection in large distribution networks. Int. J. Elect. Power Energy Syst. 94, 141–150 (2018)CrossRef Mortazavi, S.H., Moravej, Z., Shahrtash, S.M.: A hybrid method for arcing faults detection in large distribution networks. Int. J. Elect. Power Energy Syst. 94, 141–150 (2018)CrossRef
20.
Zurück zum Zitat Oppenheim, A.V., Shafer, R.W.: Digital signal processing. 784p, Englewood cliffs NJ, prentice hall (1975) Oppenheim, A.V., Shafer, R.W.: Digital signal processing. 784p, Englewood cliffs NJ, prentice hall (1975)
21.
Zurück zum Zitat Aiello, M., Cataliotti, A., Nuccio, S.: A Chirp Z transform based synchronizer for power systems measurement. IEEE Trans. Inst. Meas. 54(3), 1025–1032 (2005)CrossRef Aiello, M., Cataliotti, A., Nuccio, S.: A Chirp Z transform based synchronizer for power systems measurement. IEEE Trans. Inst. Meas. 54(3), 1025–1032 (2005)CrossRef
22.
Zurück zum Zitat Aiello, M., Cataliotti, A., Cosentino, V., Nuccio, S.: Synchronization techniques for power quality instruments. IEEE Trans. Inst. Meas. 56(5), 1511–1519 (2007)CrossRef Aiello, M., Cataliotti, A., Cosentino, V., Nuccio, S.: Synchronization techniques for power quality instruments. IEEE Trans. Inst. Meas. 56(5), 1511–1519 (2007)CrossRef
23.
Zurück zum Zitat Diao, R., Meng, Q.: An interpolation algorithm for discrete Fourier transforms of weighted damped sinusoidal signals. IEEE Trans. Inst. Meas. 63(6), 1505–1513 (2014)CrossRef Diao, R., Meng, Q.: An interpolation algorithm for discrete Fourier transforms of weighted damped sinusoidal signals. IEEE Trans. Inst. Meas. 63(6), 1505–1513 (2014)CrossRef
24.
Zurück zum Zitat Orallo, C.M., Carugati, I., et al.: Harmonics measurement with a modulated sliding discrete Fourier transform algorithm. IEEE Trans. Inst. Meas. 63(4), 781–793 (2014)CrossRef Orallo, C.M., Carugati, I., et al.: Harmonics measurement with a modulated sliding discrete Fourier transform algorithm. IEEE Trans. Inst. Meas. 63(4), 781–793 (2014)CrossRef
25.
Zurück zum Zitat Aiello, M., Cataliotti, A., Nuccio, S.: A comparison of spectrum estimation technique for periodic and not stationary signals. Proc. IMTC. 2, 1130–1134 (2001) Aiello, M., Cataliotti, A., Nuccio, S.: A comparison of spectrum estimation technique for periodic and not stationary signals. Proc. IMTC. 2, 1130–1134 (2001)
26.
Zurück zum Zitat Artale, G., Cataliotti, A., et al.: Arc fault detection method based on CZT low frequency harmonic current analysis. IEEE Trans. Inst. Meas. 66(5), 888–896 (2017)CrossRef Artale, G., Cataliotti, A., et al.: Arc fault detection method based on CZT low frequency harmonic current analysis. IEEE Trans. Inst. Meas. 66(5), 888–896 (2017)CrossRef
27.
Zurück zum Zitat Wang, T.T.: The segmented chirp z transform and its application in spectrum analysis. IEEE Trans. Inst. Meas. 39(2), 318–323 (1990)CrossRef Wang, T.T.: The segmented chirp z transform and its application in spectrum analysis. IEEE Trans. Inst. Meas. 39(2), 318–323 (1990)CrossRef
28.
Zurück zum Zitat Chen, J.C., Phung, B.T., Zhang, D.M., Blackburn, T., Ambikairajah, E.: Study on high impedance fault arcing current characteristics. 2013 Australasian Universities Power Engineering Conf. (2013) Chen, J.C., Phung, B.T., Zhang, D.M., Blackburn, T., Ambikairajah, E.: Study on high impedance fault arcing current characteristics. 2013 Australasian Universities Power Engineering Conf. (2013)
29.
Zurück zum Zitat Elkalashy, N., Lehtonen, M., Darwish, H.A., et al.: Modeling and experimental verification of high impedance arcing fault in medium voltage networks. IEEE Trans. Dielectr. Electr. Insul. 14(2), 375–383 (2007)CrossRef Elkalashy, N., Lehtonen, M., Darwish, H.A., et al.: Modeling and experimental verification of high impedance arcing fault in medium voltage networks. IEEE Trans. Dielectr. Electr. Insul. 14(2), 375–383 (2007)CrossRef
30.
Zurück zum Zitat Costa, F.B., Souza, B.A., Brito, N.S.D., et al.: Real-time detection of transients induced by high-impedance faults based on the boundary wavelet transform. IEEE Trans. Ind. Appl. 51(6), 5312–5323 (2015)CrossRef Costa, F.B., Souza, B.A., Brito, N.S.D., et al.: Real-time detection of transients induced by high-impedance faults based on the boundary wavelet transform. IEEE Trans. Ind. Appl. 51(6), 5312–5323 (2015)CrossRef
31.
Zurück zum Zitat Sarwagya, K., De, S., Nayak, P.K.: High impedance fault detection in electrical power distribution system using moving sum approach. IET Sci. Meas. Tech. 12(1), 1–8 (2018)CrossRef Sarwagya, K., De, S., Nayak, P.K.: High impedance fault detection in electrical power distribution system using moving sum approach. IET Sci. Meas. Tech. 12(1), 1–8 (2018)CrossRef
Metadaten
Titel
High impedance fault detection based on current harmonic analysis using Chirp Z transform
verfasst von
Mojtaba Karimi
Navid Ghaffarzadeh
Publikationsdatum
06.03.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
Energy Systems / Ausgabe 3/2022
Print ISSN: 1868-3967
Elektronische ISSN: 1868-3975
DOI
https://doi.org/10.1007/s12667-021-00431-1

Weitere Artikel der Ausgabe 3/2022

Energy Systems 3/2022 Zur Ausgabe