Skip to main content
Erschienen in: Mechanics of Composite Materials 3/2018

09.07.2018

Investigation of Two- and Three-Body Wear Resistance on Flowable Bulk-Fill and Resin-Based Composites

verfasst von: E. Ç. Yilmaz, R. Sadeler

Erschienen in: Mechanics of Composite Materials | Ausgabe 3/2018

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The purpose of the present study was to investigate two and three-body wear resistance and hardness of eighth kinds of modern bulk-fill and resin-based composite materials — Grandio, Estelite Flow, Filtek bulk-fill, Charisma, Clearfil, Ultimate, Quadrant, and G-aenial. All samples were kept in distilled water for one week, and their Vickers hardness was determined before two- and three-body wear tests. The mean volume loss of all specimens after the wear tests was determined by the 3D profilometry. In addition, a random specimen was selected from each test group and scanning electron microscope images were taken for an analysis of wear tracks. The surface morphology of the Clearfil and Ultimate composite materials was damaged severely, whereas Grandio and Charisma had a very smooth surface after two-body wear tests. The lowest mean volume loss was measured in micro-fill Grandio two-body and three-body wear tests. The Filtek bulk-fill and resinbased composites showed similar two- and three-body wear behavior. For the composite materials considered, correlations between the filler volume loss, Vickers hardness, and two- and three-body wear resistances were found to be insignificant.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat F. Engelhardt et al., “Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis,” Clin. Oral Investig., 20, No. 8, 2123-2130 (2016).CrossRef F. Engelhardt et al., “Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis,” Clin. Oral Investig., 20, No. 8, 2123-2130 (2016).CrossRef
2.
Zurück zum Zitat N. Ilie and K. Stark, “Curing behaviour of high-viscosity bulk-fill composites,” J. of Dentistry, 42, No. 8, 977-985 (2014).CrossRef N. Ilie and K. Stark, “Curing behaviour of high-viscosity bulk-fill composites,” J. of Dentistry, 42, No. 8, 977-985 (2014).CrossRef
3.
Zurück zum Zitat S. Bucuta and N. Ilie, “Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites,” Clin. Oral Investig., 18, N. 8, 1991-2000 (2014).CrossRef S. Bucuta and N. Ilie, “Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites,” Clin. Oral Investig., 18, N. 8, 1991-2000 (2014).CrossRef
4.
Zurück zum Zitat U. Lohbauer et al., “The effect of different light-curing units on fatigue behavior and degree of conversion of a resin composite,” Dental Mater., 21, No. 7, 608-615 (2005).CrossRef U. Lohbauer et al., “The effect of different light-curing units on fatigue behavior and degree of conversion of a resin composite,” Dental Mater., 21, No. 7, 608-615 (2005).CrossRef
5.
Zurück zum Zitat N. Koottathape et al., Quantitative wear and wear damage analysis of composite resins in vitro,” J. Mech. Behav. Biomed. Mater., 29, 508-516 (2014).CrossRef N. Koottathape et al., Quantitative wear and wear damage analysis of composite resins in vitro,” J. Mech. Behav. Biomed. Mater., 29, 508-516 (2014).CrossRef
6.
Zurück zum Zitat G. J. Christensen, “Remaining challenges with Class II resin-based composite restorations,” J. Am. Dental Assoc., 138, No. 11, 1487-1489 (2007).CrossRef G. J. Christensen, “Remaining challenges with Class II resin-based composite restorations,” J. Am. Dental Assoc., 138, No. 11, 1487-1489 (2007).CrossRef
7.
Zurück zum Zitat D. Lazaridou et al., “Are resin composites suitable replacements for amalgam? A study of two-body wear,” Clin. Oral Investig., 19, No. 6, 1485-1492 (2015).CrossRef D. Lazaridou et al., “Are resin composites suitable replacements for amalgam? A study of two-body wear,” Clin. Oral Investig., 19, No. 6, 1485-1492 (2015).CrossRef
8.
Zurück zum Zitat L. H. Mair et al., “Wear: Mechanisms, manifestations and measurement. Report of a workshop,” J. Dentistry, 24, Nos. 1-2, 141-148 (1996).CrossRef L. H. Mair et al., “Wear: Mechanisms, manifestations and measurement. Report of a workshop,” J. Dentistry, 24, Nos. 1-2, 141-148 (1996).CrossRef
9.
Zurück zum Zitat S. K. Kim et al., “A study of the effects of chewing patterns on occlusal wear,” J. Oral Rehabilit., 28. No. 11, 1048-1055 (2001).CrossRef S. K. Kim et al., “A study of the effects of chewing patterns on occlusal wear,” J. Oral Rehabilit., 28. No. 11, 1048-1055 (2001).CrossRef
10.
Zurück zum Zitat S. Hahnel et al., “Two-body wear of dental restorative materials,” J. Mech. Behav. Biomed. Mater., 4, No. 3, 237-244 (2011).CrossRef S. Hahnel et al., “Two-body wear of dental restorative materials,” J. Mech. Behav. Biomed. Mater., 4, No. 3, 237-244 (2011).CrossRef
11.
Zurück zum Zitat J. L. Ferracane, “Hygroscopic and hydrolytic effects in dental polymer networks,” Dental Mater., 22, No. 3, 211-222 (2006).CrossRef J. L. Ferracane, “Hygroscopic and hydrolytic effects in dental polymer networks,” Dental Mater., 22, No. 3, 211-222 (2006).CrossRef
12.
Zurück zum Zitat C. Mehl et al., “Wear of composite resin veneering materials and enamel in a chewing simulator,” Dental Mater, 23, No. 11, 1382-1389 (2007).CrossRef C. Mehl et al., “Wear of composite resin veneering materials and enamel in a chewing simulator,” Dental Mater, 23, No. 11, 1382-1389 (2007).CrossRef
13.
Zurück zum Zitat M. Rosentritt et al., “Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures,” Dental Mater., 22, No. 2, 176-182 (2006).CrossRef M. Rosentritt et al., “Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures,” Dental Mater., 22, No. 2, 176-182 (2006).CrossRef
14.
Zurück zum Zitat J. C. M. Souza et al., “Abrasive and sliding wear of resin composites for dental restorations,” Tribology Int., 102, 154-160 (2016).CrossRef J. C. M. Souza et al., “Abrasive and sliding wear of resin composites for dental restorations,” Tribology Int., 102, 154-160 (2016).CrossRef
15.
Zurück zum Zitat X. Hu, P.M. Marquis, and A.C. Shortall, “Influence of filler loading on the two-body wear of a dental composite,” J. Oral Rehabilit., 30, No. 7, 729-737 (2003).CrossRef X. Hu, P.M. Marquis, and A.C. Shortall, “Influence of filler loading on the two-body wear of a dental composite,” J. Oral Rehabilit., 30, No. 7, 729-737 (2003).CrossRef
16.
Zurück zum Zitat L. A. Knobloch et al., “Two-body wear resistance and degree of conversion of laboratory-processed composite materials,” Int. J. Prosthodontics, 12. No. 5, 432-438 (1999). L. A. Knobloch et al., “Two-body wear resistance and degree of conversion of laboratory-processed composite materials,” Int. J. Prosthodontics, 12. No. 5, 432-438 (1999).
17.
Zurück zum Zitat N. Koottathape et al., “Two- and three-body wear of composite resins,” Dental Mater., 28, No. 12, 1261-1270 (2012).CrossRef N. Koottathape et al., “Two- and three-body wear of composite resins,” Dental Mater., 28, No. 12, 1261-1270 (2012).CrossRef
18.
Zurück zum Zitat N. Finlay et al., “The in vitro wear behavior of experimental resin-based composites derived from a commercial formulation,” Dental Mater., 29, No. 4, 365-374 (2013).CrossRef N. Finlay et al., “The in vitro wear behavior of experimental resin-based composites derived from a commercial formulation,” Dental Mater., 29, No. 4, 365-374 (2013).CrossRef
19.
Zurück zum Zitat S. Lauvahutanon et al., “In vitro evaluation of the wear resistance of composite resin blocks for CAD/CAM,” Dental Mater. J., 34, No. 4, 495-502 (2015).CrossRef S. Lauvahutanon et al., “In vitro evaluation of the wear resistance of composite resin blocks for CAD/CAM,” Dental Mater. J., 34, No. 4, 495-502 (2015).CrossRef
20.
Zurück zum Zitat S. D. Heintze, “How to qualify and validate wear simulation devices and methods,” Dental Mater., 22, No. 8, 712-734 (2006).CrossRef S. D. Heintze, “How to qualify and validate wear simulation devices and methods,” Dental Mater., 22, No. 8, 712-734 (2006).CrossRef
21.
Zurück zum Zitat X. Hu, A. C. Shortall, and P. M. Marquis, “Wear of three dental composites under different testing conditions,” J. Oral Rehabilit., 29, No. 8, 756-764 (2002).CrossRef X. Hu, A. C. Shortall, and P. M. Marquis, “Wear of three dental composites under different testing conditions,” J. Oral Rehabilit., 29, No. 8, 756-764 (2002).CrossRef
22.
Zurück zum Zitat A. U. J. Yap, S. H. Teoh, and K. B. Tan, “Influence of water exposure on three-body wear of composite restoratives,” J. Biomed. Mater. Res., 53, No. 5, 547-553 (2000).CrossRef A. U. J. Yap, S. H. Teoh, and K. B. Tan, “Influence of water exposure on three-body wear of composite restoratives,” J. Biomed. Mater. Res., 53, No. 5, 547-553 (2000).CrossRef
23.
Zurück zum Zitat E. Yilmaz and R. Sadeler, “Effect of thermal cycling and microhardness on roughness of composite restorative materials,” J. of Restorative Dentistry, 4, No. 3, 93-96 (2016).CrossRef E. Yilmaz and R. Sadeler, “Effect of thermal cycling and microhardness on roughness of composite restorative materials,” J. of Restorative Dentistry, 4, No. 3, 93-96 (2016).CrossRef
24.
Zurück zum Zitat R. G. Chadwick et al., The effect of storage media upon the surface microhardness and abrasion resistance of 3 composites,” Dental Mater., 6, No. 2, 123-128 (1990).CrossRef R. G. Chadwick et al., The effect of storage media upon the surface microhardness and abrasion resistance of 3 composites,” Dental Mater., 6, No. 2, 123-128 (1990).CrossRef
25.
Zurück zum Zitat P. Pieters et al., “Water uptake of a silorane-based composite used in restorative dentistry,” Mech. Compos. Mater., 50, No. 3, 395-402 (2014).CrossRef P. Pieters et al., “Water uptake of a silorane-based composite used in restorative dentistry,” Mech. Compos. Mater., 50, No. 3, 395-402 (2014).CrossRef
26.
Zurück zum Zitat W. J. Obrien and J. Yee, “Microstructure of posterior restorations of composite resin after clinical wear,” Operative Dentistry, 5, No. 3, 90-94 (1980). W. J. Obrien and J. Yee, “Microstructure of posterior restorations of composite resin after clinical wear,” Operative Dentistry, 5, No. 3, 90-94 (1980).
27.
Zurück zum Zitat K. D. Jorgensen, “Restorative resins – abrasion vs. mechanical-properties,” Scandinav. J. Dental Res., 88, No. 6, 557-568 (1980). K. D. Jorgensen, “Restorative resins – abrasion vs. mechanical-properties,” Scandinav. J. Dental Res., 88, No. 6, 557-568 (1980).
28.
Zurück zum Zitat J. R. Condon and J. L. Ferracane, “In vitro wear of composite with varied cure, filler level, and filler treatment,” J. Dental Res., 76, No. 7, 1405-1411 (1997).CrossRef J. R. Condon and J. L. Ferracane, “In vitro wear of composite with varied cure, filler level, and filler treatment,” J. Dental Res., 76, No. 7, 1405-1411 (1997).CrossRef
Metadaten
Titel
Investigation of Two- and Three-Body Wear Resistance on Flowable Bulk-Fill and Resin-Based Composites
verfasst von
E. Ç. Yilmaz
R. Sadeler
Publikationsdatum
09.07.2018
Verlag
Springer US
Erschienen in
Mechanics of Composite Materials / Ausgabe 3/2018
Print ISSN: 0191-5665
Elektronische ISSN: 1573-8922
DOI
https://doi.org/10.1007/s11029-018-9750-8

Weitere Artikel der Ausgabe 3/2018

Mechanics of Composite Materials 3/2018 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.