Skip to main content
Erschienen in: Experiments in Fluids 6/2007

01.06.2007 | Research Article

Modeling and correction of peak-locking in digital PIV

verfasst von: Murali R. Cholemari

Erschienen in: Experiments in Fluids | Ausgabe 6/2007

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The systematic tendency of PIV evaluations to bias towards integral pixel values is known as peak-locking. These errors, although small, significantly affect the statistics extracted from such measurements. In this paper, the process by which such errors accrue is modeled, and a scheme for the removal of the same is suggested. Specifically, the modeling process considers FFT PIV with discrete window offset. The results are applied to actual situations and the results are found to be encouraging. The process is computationally inexpensive, and can be applied as a post processing technique to existing data to correct peak-locking.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Adrian RJ (1991) Particle-imaging techniques for experimental fluid mechanics. Ann Rev Fluid Mech 23:261–304CrossRef Adrian RJ (1991) Particle-imaging techniques for experimental fluid mechanics. Ann Rev Fluid Mech 23:261–304CrossRef
Zurück zum Zitat Angele KP, Muhammad-Klingmann B (2005) A simple model for the effect of peak-locking on the accuracy of boundary layer turbulent statistics in digital piv. Exp Fluids 38:341–347CrossRef Angele KP, Muhammad-Klingmann B (2005) A simple model for the effect of peak-locking on the accuracy of boundary layer turbulent statistics in digital piv. Exp Fluids 38:341–347CrossRef
Zurück zum Zitat Chen J, Katz J (2005) Elimination of peak-locking error in piv analysis using the correlation mapping method. Meas Sci Technol 16:1605–1618CrossRef Chen J, Katz J (2005) Elimination of peak-locking error in piv analysis using the correlation mapping method. Meas Sci Technol 16:1605–1618CrossRef
Zurück zum Zitat Cholemari MR (2004) Buoyancy driven turbulence in a vertical pipe. Ph.D. Thesis, Department of mechanical engineering, Indian Institute of Science Cholemari MR (2004) Buoyancy driven turbulence in a vertical pipe. Ph.D. Thesis, Department of mechanical engineering, Indian Institute of Science
Zurück zum Zitat Cholemari MR, Arakeri JH (2005) Experiments and a model of turbulent exchange flow in a vertical pipe. Int J Heat Mass Transfer 48:4467–4473CrossRef Cholemari MR, Arakeri JH (2005) Experiments and a model of turbulent exchange flow in a vertical pipe. Int J Heat Mass Transfer 48:4467–4473CrossRef
Zurück zum Zitat Christensen KT (2004) On the influence of peaklocking errors on turbulence statistics compared from piv ensembles. Exp Fluids 36(3):484–497CrossRef Christensen KT (2004) On the influence of peaklocking errors on turbulence statistics compared from piv ensembles. Exp Fluids 36(3):484–497CrossRef
Zurück zum Zitat Gui L, Wereley S (2002) A correlation-based continuous window-shift technique to reduce the peak-locking effect in digital piv image evaluation. Exp Fluids 32:506–517CrossRef Gui L, Wereley S (2002) A correlation-based continuous window-shift technique to reduce the peak-locking effect in digital piv image evaluation. Exp Fluids 32:506–517CrossRef
Zurück zum Zitat Huang H, Dabiri D, Gharib M (1997) On the errors of digital particle image velocimetry. Meas Sci Technol 8:1427–1440CrossRef Huang H, Dabiri D, Gharib M (1997) On the errors of digital particle image velocimetry. Meas Sci Technol 8:1427–1440CrossRef
Zurück zum Zitat Keane RD, Adrian RJ (1992) Theory of cross-correlation analysis of piv images. Appl Sci Res 49:191–215CrossRef Keane RD, Adrian RJ (1992) Theory of cross-correlation analysis of piv images. Appl Sci Res 49:191–215CrossRef
Zurück zum Zitat Lecordier B, Demare D, Vervisch LMJ, Réveillon J, Trinité M (2001) Estimation of the accuracy of piv treatments for turbulent flow studies by direct numerical simulation of multi-phase flow. Meas Sci Technol 12(1382–1391) Lecordier B, Demare D, Vervisch LMJ, Réveillon J, Trinité M (2001) Estimation of the accuracy of piv treatments for turbulent flow studies by direct numerical simulation of multi-phase flow. Meas Sci Technol 12(1382–1391)
Zurück zum Zitat Liao Q, Cowen EA (2005) An efficient anti-aliasing spectral continuous window shifting technique for piv. Exp Fluids 38:197–208CrossRef Liao Q, Cowen EA (2005) An efficient anti-aliasing spectral continuous window shifting technique for piv. Exp Fluids 38:197–208CrossRef
Zurück zum Zitat Nogueira J, Lecuona A, Rodriguez PA (2001) Identification of a new source of peak locking and its removal in conventional and super-resolution piv techniques. Exp Fluids 30:309–316CrossRef Nogueira J, Lecuona A, Rodriguez PA (2001) Identification of a new source of peak locking and its removal in conventional and super-resolution piv techniques. Exp Fluids 30:309–316CrossRef
Zurück zum Zitat Piirto M, Eloranta H, Saarenrinne P, Karvinen R (2005) A comparative study of five different piv interrogation algorithms. Exp Fluids 39:571–588CrossRef Piirto M, Eloranta H, Saarenrinne P, Karvinen R (2005) A comparative study of five different piv interrogation algorithms. Exp Fluids 39:571–588CrossRef
Zurück zum Zitat Pope SB (2000) Turbulent flows. Cambridge University Press, CambridgeMATH Pope SB (2000) Turbulent flows. Cambridge University Press, CambridgeMATH
Zurück zum Zitat Prasad AK (2000) Particle image velocimetry. Curr Sci 79:51–60 Prasad AK (2000) Particle image velocimetry. Curr Sci 79:51–60
Zurück zum Zitat Prasad AK, Adrian RJ, Landreth CC, Offutt PW (1992) Effect of resolution on the speed and accuracy of particle image velocimetry interrogation. Exp Fluids 13:105–116CrossRef Prasad AK, Adrian RJ, Landreth CC, Offutt PW (1992) Effect of resolution on the speed and accuracy of particle image velocimetry interrogation. Exp Fluids 13:105–116CrossRef
Zurück zum Zitat Raffel M, Willert CE, Kompenhans J (1998) Particle image velocimetry. Springer, Heidelberg Raffel M, Willert CE, Kompenhans J (1998) Particle image velocimetry. Springer, Heidelberg
Zurück zum Zitat Roesgen T (2003) Optimal subpixel interpolation in particle image velocimetry. Exp Fluids 35:252–256CrossRef Roesgen T (2003) Optimal subpixel interpolation in particle image velocimetry. Exp Fluids 35:252–256CrossRef
Zurück zum Zitat Roth GI, Katz J (2001) Five techniques for increasing the speed and accuracy of piv interrogation. Meas Sci Technol 12:238–245CrossRef Roth GI, Katz J (2001) Five techniques for increasing the speed and accuracy of piv interrogation. Meas Sci Technol 12:238–245CrossRef
Zurück zum Zitat Saddoughi SG, Veeravalli SV (1994) Local isotropy in turbulent boundary layers at high reynolds number. J Fluid Mech 268:333–372CrossRef Saddoughi SG, Veeravalli SV (1994) Local isotropy in turbulent boundary layers at high reynolds number. J Fluid Mech 268:333–372CrossRef
Zurück zum Zitat Scarano F, Reithmuller ML (2000) Advances in iterative multigrid piv image processing. Exp Fluids [suppl], pp S51–S60 Scarano F, Reithmuller ML (2000) Advances in iterative multigrid piv image processing. Exp Fluids [suppl], pp S51–S60
Zurück zum Zitat Westerweel J (1997) Fundamentals of digital particle image velocimetry. Meas Sci Tech 8:1379–1392CrossRef Westerweel J (1997) Fundamentals of digital particle image velocimetry. Meas Sci Tech 8:1379–1392CrossRef
Zurück zum Zitat Westerweel J (2000a) Effect of sensor geometry on the performance of piv interrogation. In: Adrian RJ, Durao DFG, Durst F, Heitor MV, Maeda M, Whitelaw JH (eds) Laser techniques applied to fluid mechanics. Springer, Heidelberg, pp 37–55 Westerweel J (2000a) Effect of sensor geometry on the performance of piv interrogation. In: Adrian RJ, Durao DFG, Durst F, Heitor MV, Maeda M, Whitelaw JH (eds) Laser techniques applied to fluid mechanics. Springer, Heidelberg, pp 37–55
Zurück zum Zitat Westerweel J (2000b) Theoretical analysis of the measurement precision in particle image velocimetry. Exp Fluids [suppl], pp s3–s12 Westerweel J (2000b) Theoretical analysis of the measurement precision in particle image velocimetry. Exp Fluids [suppl], pp s3–s12
Zurück zum Zitat Westerweel J, Dabiri D, Gharib M (1997) The effect of a descrete window offset on the accuracy of cross-correlation analysis of digital PIV recordings. Exp Fluids 23:20–28CrossRef Westerweel J, Dabiri D, Gharib M (1997) The effect of a descrete window offset on the accuracy of cross-correlation analysis of digital PIV recordings. Exp Fluids 23:20–28CrossRef
Metadaten
Titel
Modeling and correction of peak-locking in digital PIV
verfasst von
Murali R. Cholemari
Publikationsdatum
01.06.2007
Verlag
Springer-Verlag
Erschienen in
Experiments in Fluids / Ausgabe 6/2007
Print ISSN: 0723-4864
Elektronische ISSN: 1432-1114
DOI
https://doi.org/10.1007/s00348-007-0300-8

Weitere Artikel der Ausgabe 6/2007

Experiments in Fluids 6/2007 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.