Skip to main content
Erschienen in: Experimental Mechanics 6/2011

01.07.2011

Analysis and Artifact Correction for Volume Correlation Measurements Using Tomographic Images from a Laboratory X-ray Source

verfasst von: N. Limodin, J. Réthoré, J. Adrien, J.-Y. Buffière, F. Hild, S. Roux

Erschienen in: Experimental Mechanics | Ausgabe 6/2011

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The effects of three artifacts (reconstruction, beam hardening and temperature of the X-ray tube) associated with the use of a lab tomograph are analyzed in terms of their induced biases for Digital Volume Correlation (DVC) from a series of reconstructed volumes acquired successively. The most detrimental effect is due to spurious dilatational strains induced by temperature variations in the tomograph. If they are not accounted for, any quantitative kinematic measurement is impossible for strain levels below 0.5%.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Ambrose J, Hounsfield GN (1973) Computerized transverse axial tomography. Br J Radiol 46(542):148–149 Ambrose J, Hounsfield GN (1973) Computerized transverse axial tomography. Br J Radiol 46(542):148–149
2.
Zurück zum Zitat Hounsfield GN (1973) Computerized transverse axial scanning (tomography). 1. Description of system. Br J Radiol 46(552):1016–22CrossRef Hounsfield GN (1973) Computerized transverse axial scanning (tomography). 1. Description of system. Br J Radiol 46(552):1016–22CrossRef
3.
Zurück zum Zitat Baruchel J, Buffière J-Y, Maire E, Merle P, Peix G (2000) X-Ray tomography in material sciences. Hermes Science, Paris Baruchel J, Buffière J-Y, Maire E, Merle P, Peix G (2000) X-Ray tomography in material sciences. Hermes Science, Paris
4.
Zurück zum Zitat Bernard D (ed) (2008) 1st conference on 3D-imaging of materials and systems 2008. ICMCB, Bordeaux Bernard D (ed) (2008) 1st conference on 3D-imaging of materials and systems 2008. ICMCB, Bordeaux
5.
Zurück zum Zitat Ludwig O, Dimichiel M, Salvo L, Suéry M, Falus P (2005) In situ Three-dimensional microstructural investigation of solidification of an Al-Cu alloy by ultrafast X-ray microtomography. Metall Mater Trans A 36(6):1515–1523CrossRef Ludwig O, Dimichiel M, Salvo L, Suéry M, Falus P (2005) In situ Three-dimensional microstructural investigation of solidification of an Al-Cu alloy by ultrafast X-ray microtomography. Metall Mater Trans A 36(6):1515–1523CrossRef
6.
Zurück zum Zitat Maire E, Colombo P, Adrien J, Babout L, Biasetto L (2007) Characterization of the morphology of cellular ceramics by 3D image processing of X-ray tomography. J Eur Ceram Soc 27:1973–1981CrossRef Maire E, Colombo P, Adrien J, Babout L, Biasetto L (2007) Characterization of the morphology of cellular ceramics by 3D image processing of X-ray tomography. J Eur Ceram Soc 27:1973–1981CrossRef
7.
Zurück zum Zitat Juettner T, Moertel H, Svinka V, Svinka R (2007) Structure of kaoline-alumina based foam ceramics for high temperature applications. J Eur Ceram Soc 27:1435–1441CrossRef Juettner T, Moertel H, Svinka V, Svinka R (2007) Structure of kaoline-alumina based foam ceramics for high temperature applications. J Eur Ceram Soc 27:1435–1441CrossRef
8.
Zurück zum Zitat Chotarda TJ, Smith A, Boncoeur MP, Fargeot D, Gault C (2003) Characterisation of early stage calcium aluminate cement hydration by combination of non-destructive techniques: acoustic emission and X-ray tomography. J Eur Ceram Soc 23:2211–2223.CrossRef Chotarda TJ, Smith A, Boncoeur MP, Fargeot D, Gault C (2003) Characterisation of early stage calcium aluminate cement hydration by combination of non-destructive techniques: acoustic emission and X-ray tomography. J Eur Ceram Soc 23:2211–2223.CrossRef
9.
Zurück zum Zitat Maire E, Fazekas A, Salvo L, Dendievel R, Youssef S, Cloetens P, Letang JM (2003) X-ray tomography applied to the characterization of cellular materials. Related finite element modeling problems. Comp Sci Tech 63(16): 2431–2443CrossRef Maire E, Fazekas A, Salvo L, Dendievel R, Youssef S, Cloetens P, Letang JM (2003) X-ray tomography applied to the characterization of cellular materials. Related finite element modeling problems. Comp Sci Tech 63(16): 2431–2443CrossRef
10.
Zurück zum Zitat Babout L, Maire E, Buffière J-Y, Fougères R (2001) Characterisation by X-ray computed tomography of decohesion, porosity growth and coalescence in model metal matrix composites. Acta Mater 49(11):2055–2063CrossRef Babout L, Maire E, Buffière J-Y, Fougères R (2001) Characterisation by X-ray computed tomography of decohesion, porosity growth and coalescence in model metal matrix composites. Acta Mater 49(11):2055–2063CrossRef
11.
Zurück zum Zitat Bontaz-Carion J, Pellegrini Y-P (2006) X-ray microtomography analysis of dynamic damage in tantalum. Adv Eng Mater 8(6):480–486CrossRef Bontaz-Carion J, Pellegrini Y-P (2006) X-ray microtomography analysis of dynamic damage in tantalum. Adv Eng Mater 8(6):480–486CrossRef
12.
Zurück zum Zitat Sinclair R, Preuss M, Maire E, Buffière J-Y, Bowen P, Withers PJ (2004) The effect of fibre fractures in the bridging zone of fatigue cracked Ti-6Al-4V/SiC fibre composites. Acta Mater 52(6):1423–1438CrossRef Sinclair R, Preuss M, Maire E, Buffière J-Y, Bowen P, Withers PJ (2004) The effect of fibre fractures in the bridging zone of fatigue cracked Ti-6Al-4V/SiC fibre composites. Acta Mater 52(6):1423–1438CrossRef
13.
Zurück zum Zitat Ferrié E, Buffière J-Y, Ludwig W, Gravouil A, Edwards L (2006) Fatigue crack propagation: in situ visualization using X-ray microtomography and 3D simulation using the extended finite element method. Acta Mater 54(4):1111–1122CrossRef Ferrié E, Buffière J-Y, Ludwig W, Gravouil A, Edwards L (2006) Fatigue crack propagation: in situ visualization using X-ray microtomography and 3D simulation using the extended finite element method. Acta Mater 54(4):1111–1122CrossRef
14.
Zurück zum Zitat Buffière J-Y, Ferrié E, Proudhon H, Ludwig W (2006) Three-dimensional visualisation of fatigue cracks in metals using high resolution synchrotron X-ray micro-tomography. Mater Sci Technol 22(9):1019–1024CrossRef Buffière J-Y, Ferrié E, Proudhon H, Ludwig W (2006) Three-dimensional visualisation of fatigue cracks in metals using high resolution synchrotron X-ray micro-tomography. Mater Sci Technol 22(9):1019–1024CrossRef
15.
Zurück zum Zitat Nielsen SF, Poulsen HF, Beckmann F, Thorning C, Wert JA (2003) Measurements of plastic displacement gradient components in three dimensions using marker particles and synchrotron X-ray absorption microtomography. Acta Mater 51(8):2407–2415CrossRef Nielsen SF, Poulsen HF, Beckmann F, Thorning C, Wert JA (2003) Measurements of plastic displacement gradient components in three dimensions using marker particles and synchrotron X-ray absorption microtomography. Acta Mater 51(8):2407–2415CrossRef
16.
Zurück zum Zitat Bay BK, Smith TS, Fyhrie DP, Saad M (1999) Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp Mech 39:217–226CrossRef Bay BK, Smith TS, Fyhrie DP, Saad M (1999) Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp Mech 39:217–226CrossRef
17.
Zurück zum Zitat Bornert M, Chaix J-M, Doumalin P, Dupré J-C, Fournel T, Jeulin D, Maire E, Moreaud M, Moulinec H (2004) Mesure tridimensionnelle de champs cinématiques par imagerie volumique pour l’analyse des matériaux et des structures. Inst Mes Métrol 4:43–88 Bornert M, Chaix J-M, Doumalin P, Dupré J-C, Fournel T, Jeulin D, Maire E, Moreaud M, Moulinec H (2004) Mesure tridimensionnelle de champs cinématiques par imagerie volumique pour l’analyse des matériaux et des structures. Inst Mes Métrol 4:43–88
18.
Zurück zum Zitat McKinley TO, Bay BK (2003) Trabecular bone strain changes associated with subchondral stiffening of the proximal tibia. J Biomech 36(2):155–163CrossRef McKinley TO, Bay BK (2003) Trabecular bone strain changes associated with subchondral stiffening of the proximal tibia. J Biomech 36(2):155–163CrossRef
19.
Zurück zum Zitat Roux S, Hild F, Viot P, Bernard D (2008) Three dimensional image correlation from X-Ray computed tomography of solid foam. Comp Part A 39(8):1253–1265CrossRef Roux S, Hild F, Viot P, Bernard D (2008) Three dimensional image correlation from X-Ray computed tomography of solid foam. Comp Part A 39(8):1253–1265CrossRef
20.
Zurück zum Zitat Réthoré J, Tinnes J-P, Roux S, Buffière J-Y, Hild F (2008) Extended three-dimensional digital image correlation (X3D-DIC). C R Méc 336:643–649MATH Réthoré J, Tinnes J-P, Roux S, Buffière J-Y, Hild F (2008) Extended three-dimensional digital image correlation (X3D-DIC). C R Méc 336:643–649MATH
21.
Zurück zum Zitat Limodin N, Réthoré J, Buffière J-Y, Gravouil A, Hild F, Roux S (2009) Crack closure and stress intensity factor measurements in nodular graphite cast iron using 3D correlation of laboratory X-ray microtomography images. Acta Mater 57(14):4090–4101CrossRef Limodin N, Réthoré J, Buffière J-Y, Gravouil A, Hild F, Roux S (2009) Crack closure and stress intensity factor measurements in nodular graphite cast iron using 3D correlation of laboratory X-ray microtomography images. Acta Mater 57(14):4090–4101CrossRef
22.
Zurück zum Zitat Rannou J, Limodin N, Réthoré J, Gravouil A, Ludwig W, Baïetto-Dubourg M-C, Buffière J-Y, Combescure A, Hild F, Roux S (2010) Three dimensional experimental and numerical multiscale analysis of a fatigue crack. Comput Methods Appl Mech Eng 199:1307–1325CrossRef Rannou J, Limodin N, Réthoré J, Gravouil A, Ludwig W, Baïetto-Dubourg M-C, Buffière J-Y, Combescure A, Hild F, Roux S (2010) Three dimensional experimental and numerical multiscale analysis of a fatigue crack. Comput Methods Appl Mech Eng 199:1307–1325CrossRef
23.
Zurück zum Zitat Kak AC, Slaney M (1988) Principles of computerized tomographic imaging. IEEE, New YorkMATH Kak AC, Slaney M (1988) Principles of computerized tomographic imaging. IEEE, New YorkMATH
24.
Zurück zum Zitat Stock SR (2008) MicroComputed tomography: methodology and applications. CRC, Boca RatonCrossRef Stock SR (2008) MicroComputed tomography: methodology and applications. CRC, Boca RatonCrossRef
25.
Zurück zum Zitat Stock SR (2008) Recent advances in X-Ray microtomography applied to materials. Int Mater Rev 53(3):129–181CrossRef Stock SR (2008) Recent advances in X-Ray microtomography applied to materials. Int Mater Rev 53(3):129–181CrossRef
26.
Zurück zum Zitat Davis GR, Elliot JC (2006) Artefacts in X-ray microtomography of materials. Mater Sci Technol 22(9):1011–1018CrossRef Davis GR, Elliot JC (2006) Artefacts in X-ray microtomography of materials. Mater Sci Technol 22(9):1011–1018CrossRef
28.
Zurück zum Zitat Rivers ML, Wang Y (2006) Recent developments in microtomography at GeoSoilEnviroCARS. In: Bonse U (ed) Developments in X-ray tomography V, vol 6318. SPIE, Bellingham, pp 0J-1-15 Rivers ML, Wang Y (2006) Recent developments in microtomography at GeoSoilEnviroCARS. In: Bonse U (ed) Developments in X-ray tomography V, vol 6318. SPIE, Bellingham, pp 0J-1-15
29.
Zurück zum Zitat Ketcham RA (2006) New algorithms for ring artefact removal. In: Bonse U (ed) Developments in X-ray tomography V, vol 6318. SPIE, Bellingham, pp 00-1-15 Ketcham RA (2006) New algorithms for ring artefact removal. In: Bonse U (ed) Developments in X-ray tomography V, vol 6318. SPIE, Bellingham, pp 00-1-15
30.
Zurück zum Zitat Salmon PL, Liu X, Sasov A (2009) A post scan method for correcting artefacts of slow geometry changes during micro-tomographic scans. J X-Ray Sci Technol 17:161–174 Salmon PL, Liu X, Sasov A (2009) A post scan method for correcting artefacts of slow geometry changes during micro-tomographic scans. J X-Ray Sci Technol 17:161–174
31.
Zurück zum Zitat Feldkamp LA, Davis LC, Kress JW (1984) Practical cone beam algorithm. J Opt Soc Am A1:612–619CrossRef Feldkamp LA, Davis LC, Kress JW (1984) Practical cone beam algorithm. J Opt Soc Am A1:612–619CrossRef
32.
Zurück zum Zitat Hild F, Maire E, Roux S, Witz J-F (2009) Three dimensional analysis of a compression test on stone wool. Acta Mater 57:3310–3320CrossRef Hild F, Maire E, Roux S, Witz J-F (2009) Three dimensional analysis of a compression test on stone wool. Acta Mater 57:3310–3320CrossRef
33.
Zurück zum Zitat De Vriendt AB (1987) La transmission de la chaleur. Morin, Québec De Vriendt AB (1987) La transmission de la chaleur. Morin, Québec
34.
Zurück zum Zitat Besnard G, Hild F, Roux S (2006) “Finite-element” displacement fields analysis from digital images: application to Portevin-Le Chatelier bands. Exp Mech 46:789–803CrossRef Besnard G, Hild F, Roux S (2006) “Finite-element” displacement fields analysis from digital images: application to Portevin-Le Chatelier bands. Exp Mech 46:789–803CrossRef
35.
Zurück zum Zitat Schreier HW, Braasch JR, Sutton MA (2000) Systematic errors in digital image correlation caused by intensity interpolation. Opt Eng 39(11):2915–2921CrossRef Schreier HW, Braasch JR, Sutton MA (2000) Systematic errors in digital image correlation caused by intensity interpolation. Opt Eng 39(11):2915–2921CrossRef
36.
Zurück zum Zitat Fayolle X, Calloch S, Hild F (2007) Controlling testing machines with digital image correlation. Exp Tech 31(3):57–63CrossRef Fayolle X, Calloch S, Hild F (2007) Controlling testing machines with digital image correlation. Exp Tech 31(3):57–63CrossRef
37.
Zurück zum Zitat Triconnet K, Derrien K, Hild F, Baptiste D (2009) Parameter choice for optimized digital image correlation. Opt Lasers Eng 47:728–737CrossRef Triconnet K, Derrien K, Hild F, Baptiste D (2009) Parameter choice for optimized digital image correlation. Opt Lasers Eng 47:728–737CrossRef
38.
Zurück zum Zitat Dierickx P (1996) Etude de la microstructure et des mécanismes d’endommagement de fontes G.S. ductiles: influence des traitements thermiques de ferritisation. PhD dissertation, INSA de Lyon Dierickx P (1996) Etude de la microstructure et des mécanismes d’endommagement de fontes G.S. ductiles: influence des traitements thermiques de ferritisation. PhD dissertation, INSA de Lyon
Metadaten
Titel
Analysis and Artifact Correction for Volume Correlation Measurements Using Tomographic Images from a Laboratory X-ray Source
verfasst von
N. Limodin
J. Réthoré
J. Adrien
J.-Y. Buffière
F. Hild
S. Roux
Publikationsdatum
01.07.2011
Verlag
Springer US
Erschienen in
Experimental Mechanics / Ausgabe 6/2011
Print ISSN: 0014-4851
Elektronische ISSN: 1741-2765
DOI
https://doi.org/10.1007/s11340-010-9397-4

Weitere Artikel der Ausgabe 6/2011

Experimental Mechanics 6/2011 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.