Abstract

Nocturnal polysomnography (PSG) is the gold-standard to diagnose obstructive sleep apnoea syndrome (OSAS). However, it is complex, expensive, and time-consuming. We present an automatic OSAS detection algorithm based on classification of nocturnal oxygen saturation (SaO2) recordings. The algorithm makes use of spectral and nonlinear analysis for feature extraction, principal component analysis (PCA) for preprocessing and linear discriminant analysis (LDA) for classification. We conducted a study to characterize and prospectively validate our OSAS detection algorithm. The population under study was composed of subjects suspected of suffering from OSAS. A total of 214 SaO2 signals were available. These signals were randomly divided into a training set (85 signals) and a test set (129 signals) to prospectively validate the proposed method. The OSAS detection algorithm achieved a diagnostic accuracy of 93.02% (97.00% sensitivity and 79.31% specificity) on the test set. It outperformed other alternative implementations that either use spectral and nonlinear features separately or are based on logistic regression (LR). The proposed method could be a useful tool to assist in early OSAS diagnosis, contributing to overcome the difficulties of conventional PSG.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Álvarez D, Hornero R, Abásolo D, Del Campo F, Zamarrón C (2006) Nonlinear characteristics of blood oxygen saturation from nocturnal oximetry for obstructive sleep apnoea detection. Physiol Meas 27:399–412CrossRefPubMed Álvarez D, Hornero R, Abásolo D, Del Campo F, Zamarrón C (2006) Nonlinear characteristics of blood oxygen saturation from nocturnal oximetry for obstructive sleep apnoea detection. Physiol Meas 27:399–412CrossRefPubMed
2.
Zurück zum Zitat Bishop CM (1995) Neural networks for pattern recognition. Oxford University Press, Oxford Bishop CM (1995) Neural networks for pattern recognition. Oxford University Press, Oxford
3.
4.
Zurück zum Zitat Caballero P, Álvarez-Sala R, García-Río F, Prados C, Hernán MA, Villamar J, Álvarez-Sala JL (1998) CT in the evaluation of the upper airway in healthy subjects and in patients with obstructive sleep apnea syndrome. Chest 113:111–116CrossRefPubMed Caballero P, Álvarez-Sala R, García-Río F, Prados C, Hernán MA, Villamar J, Álvarez-Sala JL (1998) CT in the evaluation of the upper airway in healthy subjects and in patients with obstructive sleep apnea syndrome. Chest 113:111–116CrossRefPubMed
5.
Zurück zum Zitat Cohen ME, Hudson DL, Deedwania PC (1996) Applying continuous chaotic modelling to cardiac signals. IEEE Eng Med Biol Mag 15:97–102CrossRef Cohen ME, Hudson DL, Deedwania PC (1996) Applying continuous chaotic modelling to cardiac signals. IEEE Eng Med Biol Mag 15:97–102CrossRef
6.
Zurück zum Zitat de Chazal P, Heneghan C, Sheridan E, Reilly R, Nolan P, O’Malley M (2003) Automated processing of the single-lead electrocardiogram for the detection of obstructive sleep apnoea. IEEE Trans Biomed Eng 50:686–696CrossRefPubMed de Chazal P, Heneghan C, Sheridan E, Reilly R, Nolan P, O’Malley M (2003) Automated processing of the single-lead electrocardiogram for the detection of obstructive sleep apnoea. IEEE Trans Biomed Eng 50:686–696CrossRefPubMed
7.
Zurück zum Zitat Del Campo F, Hornero R, Zamarrón C, Abásolo DE, Álvarez D (2006) Oxygen saturation regularity analysis in the diagnosis of obstructive sleep apnea. Artif Intel Med 37:111–118CrossRef Del Campo F, Hornero R, Zamarrón C, Abásolo DE, Álvarez D (2006) Oxygen saturation regularity analysis in the diagnosis of obstructive sleep apnea. Artif Intel Med 37:111–118CrossRef
8.
Zurück zum Zitat Dreiseitl S, Ohno-Machado L (2002) Logistic regression and artificial neural network classification models: a methodology review. J Biomed Inform 35:352–359CrossRefPubMed Dreiseitl S, Ohno-Machado L (2002) Logistic regression and artificial neural network classification models: a methodology review. J Biomed Inform 35:352–359CrossRefPubMed
9.
Zurück zum Zitat El-Solh AA, Mador MJ, Ten-Brock E, Shucard DW, Abul-Khoudoud M, Grant BJB (1999) Validity of neural network in sleep apnea. Sleep 22:105–111PubMed El-Solh AA, Mador MJ, Ten-Brock E, Shucard DW, Abul-Khoudoud M, Grant BJB (1999) Validity of neural network in sleep apnea. Sleep 22:105–111PubMed
10.
Zurück zum Zitat El-Solh AA, Magalang UJ, Mador MJ, Dmochowski J, Veeramachaneni S, Saberi A, Draw AM, Lieber BB, Grant BJB (2003) The utility of neural network in the diagnosis of Cheyne-Stokes respiration. J Med Eng Technol 27:54–58CrossRefPubMed El-Solh AA, Magalang UJ, Mador MJ, Dmochowski J, Veeramachaneni S, Saberi A, Draw AM, Lieber BB, Grant BJB (2003) The utility of neural network in the diagnosis of Cheyne-Stokes respiration. J Med Eng Technol 27:54–58CrossRefPubMed
11.
Zurück zum Zitat Fiz JA, Jané R, Solá-Soler J, Abad J, García MA, Morera J (2010) Continuous analysis and monitoring of snores and their relationship to the apnea-hypopnea index. Laryngoscope 120:854–862CrossRefPubMed Fiz JA, Jané R, Solá-Soler J, Abad J, García MA, Morera J (2010) Continuous analysis and monitoring of snores and their relationship to the apnea-hypopnea index. Laryngoscope 120:854–862CrossRefPubMed
12.
Zurück zum Zitat Friedman JH (1989) Regularized discriminant analysis. J Am Stat Assoc 84:165–175CrossRef Friedman JH (1989) Regularized discriminant analysis. J Am Stat Assoc 84:165–175CrossRef
13.
Zurück zum Zitat Gagnadoux F, Pelletier-Fleury N, Philippe C, Rakatonanahary D, Bernard F (2002) Home unattended vs hospital telemonitored polysomnography in suspected obstructive sleep apnea syndrome: a randomized crossover trial. Chest 121:753–758CrossRefPubMed Gagnadoux F, Pelletier-Fleury N, Philippe C, Rakatonanahary D, Bernard F (2002) Home unattended vs hospital telemonitored polysomnography in suspected obstructive sleep apnea syndrome: a randomized crossover trial. Chest 121:753–758CrossRefPubMed
14.
Zurück zum Zitat Golpe R, Jiménez A, Carpizo R, Cifrian JM (1999) Utility of home oximetry as a screening test for patients with moderate to severe symptoms of obstructive sleep apnea. Sleep 22:932–937PubMed Golpe R, Jiménez A, Carpizo R, Cifrian JM (1999) Utility of home oximetry as a screening test for patients with moderate to severe symptoms of obstructive sleep apnea. Sleep 22:932–937PubMed
15.
Zurück zum Zitat Hanley JA, McNeil BJ (1982) The meaning and use of the area under a receiving operating characteristic (ROC) curve. Radiology 143:29–36PubMed Hanley JA, McNeil BJ (1982) The meaning and use of the area under a receiving operating characteristic (ROC) curve. Radiology 143:29–36PubMed
16.
Zurück zum Zitat Hornero R, Álvarez D, Abásolo D, Del Campo F, Zamarrón C (2007) Utility of approximate entropy from overnight pulse oximetry data in the diagnosis of the obstructive sleep apnea syndrome. IEEE Trans Biomed Eng 54:107–113CrossRefPubMed Hornero R, Álvarez D, Abásolo D, Del Campo F, Zamarrón C (2007) Utility of approximate entropy from overnight pulse oximetry data in the diagnosis of the obstructive sleep apnea syndrome. IEEE Trans Biomed Eng 54:107–113CrossRefPubMed
17.
Zurück zum Zitat Jobson JD (1991) Applied multivariate data analysis. Volume II: categorical and multivariate methods. Springer, New York Jobson JD (1991) Applied multivariate data analysis. Volume II: categorical and multivariate methods. Springer, New York
18.
Zurück zum Zitat Jolliffe IT (2002) Principal component analysis. Springer-Verlag, New York Jolliffe IT (2002) Principal component analysis. Springer-Verlag, New York
19.
Zurück zum Zitat Kulkas A, Rauhala E, Huupponen E, Virkkala J, Tenhunen M, Saastamoinen A, Himanen SL (2008) Detection of compressed tracheal sound patterns with large amplitude variation during sleep. Med Biol Eng Comput 46:315–321CrossRefPubMed Kulkas A, Rauhala E, Huupponen E, Virkkala J, Tenhunen M, Saastamoinen A, Himanen SL (2008) Detection of compressed tracheal sound patterns with large amplitude variation during sleep. Med Biol Eng Comput 46:315–321CrossRefPubMed
20.
Zurück zum Zitat Kulkas A, Huupponen E, Virkkala J, Tenhunen M, Saastamoinen A, Rauhala E, Himanen SL (2009) New tracheal sound feature for apnoea analysis. Med Biol Eng Comput 47:405–412CrossRefPubMed Kulkas A, Huupponen E, Virkkala J, Tenhunen M, Saastamoinen A, Rauhala E, Himanen SL (2009) New tracheal sound feature for apnoea analysis. Med Biol Eng Comput 47:405–412CrossRefPubMed
21.
Zurück zum Zitat Lempel A, Ziv J (1976) On the complexity of finite sequences. IEEE Trans Inf Theory 22:75–81CrossRef Lempel A, Ziv J (1976) On the complexity of finite sequences. IEEE Trans Inf Theory 22:75–81CrossRef
22.
Zurück zum Zitat Magalang UJ, Dmochowski J, Veeramachaneni S, Draw A, Mador MJ, El-Solh A, Grant BJB (2003) Prediction of the apnea-hypopnea index from overnight pulse oximetry. Chest 124:1694–1701CrossRefPubMed Magalang UJ, Dmochowski J, Veeramachaneni S, Draw A, Mador MJ, El-Solh A, Grant BJB (2003) Prediction of the apnea-hypopnea index from overnight pulse oximetry. Chest 124:1694–1701CrossRefPubMed
23.
Zurück zum Zitat Marcos JV, Hornero R, Álvarez D, Del Campo F, Zamarrón C, López M (2008) Utility of multilayer perceptron neural network classifiers in the diagnosis of the obstructive sleep apnoea syndrome from nocturnal oximetry. Comput Methods Programs Biomed 92:79–89CrossRefPubMed Marcos JV, Hornero R, Álvarez D, Del Campo F, Zamarrón C, López M (2008) Utility of multilayer perceptron neural network classifiers in the diagnosis of the obstructive sleep apnoea syndrome from nocturnal oximetry. Comput Methods Programs Biomed 92:79–89CrossRefPubMed
24.
Zurück zum Zitat Marcos JV, Hornero R, Álvarez D, Del Campo F, López M, Zamarrón C (2008) Radial basis function classifiers to help in the diagnosis of the obstructive sleep apnoea syndrome from nocturnal oximetry. Med Biol Eng Comput 46:323–332CrossRefPubMed Marcos JV, Hornero R, Álvarez D, Del Campo F, López M, Zamarrón C (2008) Radial basis function classifiers to help in the diagnosis of the obstructive sleep apnoea syndrome from nocturnal oximetry. Med Biol Eng Comput 46:323–332CrossRefPubMed
25.
Zurück zum Zitat Marcos JV, Hornero R, Álvarez D, Del Campo F, Zamarrón C (2009) Assessment of four statistical pattern recognition techniques to assist in obstructive sleep apnoea diagnosis. Med Eng Phys 31:971–978CrossRefPubMed Marcos JV, Hornero R, Álvarez D, Del Campo F, Zamarrón C (2009) Assessment of four statistical pattern recognition techniques to assist in obstructive sleep apnoea diagnosis. Med Eng Phys 31:971–978CrossRefPubMed
26.
Zurück zum Zitat Netzer N, Eliasson AH, Netzer C, Kristo DA (2001) Overnight pulse oximetry for sleep-disordered-breathing in adults: a review. Chest 120:625–633CrossRefPubMed Netzer N, Eliasson AH, Netzer C, Kristo DA (2001) Overnight pulse oximetry for sleep-disordered-breathing in adults: a review. Chest 120:625–633CrossRefPubMed
27.
Zurück zum Zitat Penzel T, McNames J, de Chazal P, Raymond B, Murray A, Moody G (2002) Systematic comparison of different algorithms for apnoea detection based on electrocardiogram recordings. Med Biol Eng Comput 40:402–407CrossRefPubMed Penzel T, McNames J, de Chazal P, Raymond B, Murray A, Moody G (2002) Systematic comparison of different algorithms for apnoea detection based on electrocardiogram recordings. Med Biol Eng Comput 40:402–407CrossRefPubMed
28.
Zurück zum Zitat Pincus SM (2001) Assessing serial irregularity and its implications for health. Ann N Y Acad Sci 954:245–267CrossRefPubMed Pincus SM (2001) Assessing serial irregularity and its implications for health. Ann N Y Acad Sci 954:245–267CrossRefPubMed
29.
30.
Zurück zum Zitat Rodríguez JM, De Lucas P, Sánchez MJ, Izquierdo JL, Peralta R, Cubillo JM (1996) Usefulness of the visual analysis of night oximetry as a screening method in patients with suspected clinical obstructive sleep apnea syndrome. Arch Bronconeumol 32:437–441 Rodríguez JM, De Lucas P, Sánchez MJ, Izquierdo JL, Peralta R, Cubillo JM (1996) Usefulness of the visual analysis of night oximetry as a screening method in patients with suspected clinical obstructive sleep apnea syndrome. Arch Bronconeumol 32:437–441
31.
Zurück zum Zitat Tiihonen P, Pääkkönen A, Mervaala E, Hukkanen T, Töyräs J (2009) Design, construction and evaluation of an ambulatory device for screening of sleep apnea. Med Biol Eng Comput 47:56–59CrossRef Tiihonen P, Pääkkönen A, Mervaala E, Hukkanen T, Töyräs J (2009) Design, construction and evaluation of an ambulatory device for screening of sleep apnea. Med Biol Eng Comput 47:56–59CrossRef
32.
Zurück zum Zitat Van Houwelingen KG, Van Uffelen R, Van Vliet ACM (1999) The sleep apnoea syndromes. Eur Heart J 20:858–866CrossRefPubMed Van Houwelingen KG, Van Uffelen R, Van Vliet ACM (1999) The sleep apnoea syndromes. Eur Heart J 20:858–866CrossRefPubMed
33.
Zurück zum Zitat Várady P, Micsik T, Benedek S, Benyó Z (2002) A novel method for the detection of apnea and hypopnea events in respiration signals. IEEE Trans Biomed Eng 49:936–942CrossRefPubMed Várady P, Micsik T, Benedek S, Benyó Z (2002) A novel method for the detection of apnea and hypopnea events in respiration signals. IEEE Trans Biomed Eng 49:936–942CrossRefPubMed
34.
Zurück zum Zitat Vázquez JC, Tsai WH, Flemons WW, Masuda A, Brant R, Hajduk E, Whitelaw WA, Remmers JE (2000) Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea. Thorax 55:302–307CrossRefPubMed Vázquez JC, Tsai WH, Flemons WW, Masuda A, Brant R, Hajduk E, Whitelaw WA, Remmers JE (2000) Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea. Thorax 55:302–307CrossRefPubMed
35.
Zurück zum Zitat Welch PD (1967) The use of fast Fourier transform for the estimation of power spectra: a method based on time averaging over short, modified periodogram. IEEE Trans Audio Electroacoust 15:70–73CrossRef Welch PD (1967) The use of fast Fourier transform for the estimation of power spectra: a method based on time averaging over short, modified periodogram. IEEE Trans Audio Electroacoust 15:70–73CrossRef
36.
Zurück zum Zitat Young T, Evans L, Finn L, Palta M (1997) Estimation of the clinically diagnosed proportion of sleep apnea syndrome in middle-aged men and women. Sleep 20:705–706PubMed Young T, Evans L, Finn L, Palta M (1997) Estimation of the clinically diagnosed proportion of sleep apnea syndrome in middle-aged men and women. Sleep 20:705–706PubMed
37.
Zurück zum Zitat Young T, Peppard PE, Gottlieb DJ (2002) Epidemiology of obstructive sleep apnea: a population health perspective. Am J Respir Crit Care Med 165:1217–1239CrossRefPubMed Young T, Peppard PE, Gottlieb DJ (2002) Epidemiology of obstructive sleep apnea: a population health perspective. Am J Respir Crit Care Med 165:1217–1239CrossRefPubMed
38.
Zurück zum Zitat Young T, Peppard PE, Taheri S (2005) Excess weight and sleep-disordered breathing. J Appl Physiol 99:1592–1599CrossRefPubMed Young T, Peppard PE, Taheri S (2005) Excess weight and sleep-disordered breathing. J Appl Physiol 99:1592–1599CrossRefPubMed
39.
Zurück zum Zitat Zamarrón C, Gude F, Barcala J, Rodríguez JR, Romero PV (2003) Utility of oxygen saturation and heart rate spectral analysis obtained from pulse oximetric recordings in the diagnosis of sleep apnea syndrome. Chest 123:1567–1576CrossRefPubMed Zamarrón C, Gude F, Barcala J, Rodríguez JR, Romero PV (2003) Utility of oxygen saturation and heart rate spectral analysis obtained from pulse oximetric recordings in the diagnosis of sleep apnea syndrome. Chest 123:1567–1576CrossRefPubMed
40.
Zurück zum Zitat Zigel Y, Tarasiuk A, Goldshtein A (2008) Analysis of speech signals among obstructive sleep apnea patients. In: Proceedings of the IEEE 25th convention of electrical and electronic engineers, Israel, pp 760–764 Zigel Y, Tarasiuk A, Goldshtein A (2008) Analysis of speech signals among obstructive sleep apnea patients. In: Proceedings of the IEEE 25th convention of electrical and electronic engineers, Israel, pp 760–764
Metadaten
Titel
Automated detection of obstructive sleep apnoea syndrome from oxygen saturation recordings using linear discriminant analysis
verfasst von
J. Víctor Marcos
Roberto Hornero
Daniel Álvarez
Félix Del Campo
Mateo Aboy
Publikationsdatum
01.09.2010
Verlag
Springer-Verlag
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 9/2010
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-010-0646-6

Weitere Artikel der Ausgabe 9/2010

Medical & Biological Engineering & Computing 9/2010 Zur Ausgabe

Premium Partner