Erschienen in: Medical & Biological Engineering & Computing 4/2011

01.04.2011 | Original Article

Non-invasive monitoring of central blood pressure by electrical impedance tomography: first experimental evidence

verfasst von: Josep Solà, Andy Adler, Arnoldo Santos, Gerardo Tusman, Fernando Suárez Sipmann, Stephan H. Bohm

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 4/2011

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

There is a strong clinical demand for devices allowing continuous non-invasive monitoring of central blood pressure (BP). In the state of the art a new family of techniques providing BP surrogates based on the measurement of the so-called pulse wave velocity (PWV) has been proposed, eliminating the need for inflation cuffs. PWV is defined as the velocity at which pressure pulses propagate along the arterial wall. However, no technique to assess PWV within central arteries in a fully unsupervised manner has been proposed so far. In this pilot study, we provide first experimental evidence that electrical impedance tomography (EIT) is capable of measuring pressure pulses directly within the descending aorta. To obtain a wide range of BP values, we administrated noradrenalin and nitroglycerine to an anesthetized pig under mechanical ventilation. An arterial line was inserted into the ascending aorta for measuring reference BP. EIT images were generated from 32 impedance electrodes placed around the chest at the level of the axilla. Regions of Interest (ROI) such as the descending aorta and the lungs were automatically identified by a novel time-based processing algorithm as the respective EIT pixels representing these structures. The correct positions of these ROIs were confirmed by bolus injections of highly conductive concentrated saline into the right heart and into the ascending aorta. Aortic pulse transit time (PTT) values were determined as the delay between the opening of the aortic valve (obtained from arterial line) and the arrival of pressure pulses at the aortic ROI within the EIT plane. For 11 experimental conditions, with mean BP ranging from 73 to 141 mmHg, strongly significant correlation (r = −0.97, P < 0.00001) between central BP and aortic PTT was observed, suggesting that EIT-derived aortic PTT is a potential non-invasive surrogate of central BP.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Davies RJ, Jenkins NE, Stradling JR (1994) Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleep. BMJ 308:820–823PubMed Davies RJ, Jenkins NE, Stradling JR (1994) Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleep. BMJ 308:820–823PubMed
2.
Zurück zum Zitat Frerichs I, Hinz J, Hermann P, Weisser G, Hahn G, Quintel M, Hellige G (2002) Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging. IEEE Trans Med Imaging 21:646–652PubMedCrossRef Frerichs I, Hinz J, Hermann P, Weisser G, Hahn G, Quintel M, Hellige G (2002) Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging. IEEE Trans Med Imaging 21:646–652PubMedCrossRef
3.
Zurück zum Zitat Holder DS (2005) Electrical impedance tomography: methods, history and applications. In: Holder D (ed) Medical physics and biomedical engineering. Institute of Physics Publishing, Bristol Holder DS (2005) Electrical impedance tomography: methods, history and applications. In: Holder D (ed) Medical physics and biomedical engineering. Institute of Physics Publishing, Bristol
4.
Zurück zum Zitat Hurwitz BE, Shyu LY, Reddy SP, Schneiderman N, Nagel JH (1990) Coherent ensemble averaging techniques for impedance cardiography. In: Proceedings of the third annual IEEE symposium on computer-based medical systems, Chapel Hill Hurwitz BE, Shyu LY, Reddy SP, Schneiderman N, Nagel JH (1990) Coherent ensemble averaging techniques for impedance cardiography. In: Proceedings of the third annual IEEE symposium on computer-based medical systems, Chapel Hill
5.
Zurück zum Zitat Laurent S, Cockcroft J, Bortel LV, Boutouyrie P, Giannattasio C, Hayoz D, Pannier B, Vlackoppoulos C, Wilkinson I, Struijker-Boudier H (2006) Expert consensus document on arterial stiffness: methodological issues and clinical applications. Eur Heart J 27:2588–2605PubMedCrossRef Laurent S, Cockcroft J, Bortel LV, Boutouyrie P, Giannattasio C, Hayoz D, Pannier B, Vlackoppoulos C, Wilkinson I, Struijker-Boudier H (2006) Expert consensus document on arterial stiffness: methodological issues and clinical applications. Eur Heart J 27:2588–2605PubMedCrossRef
6.
Zurück zum Zitat Nichols WW, O’Rourke MF (2005) McDonald’s blood flow in arteries. Hodder Arnold, London Nichols WW, O’Rourke MF (2005) McDonald’s blood flow in arteries. Hodder Arnold, London
7.
Zurück zum Zitat O’Rourke M (2009) Time domain analysis of the arterial pulse in clinical medicine. Med Biol Eng Comput 47:119–129PubMedCrossRef O’Rourke M (2009) Time domain analysis of the arterial pulse in clinical medicine. Med Biol Eng Comput 47:119–129PubMedCrossRef
8.
Zurück zum Zitat Parati G, Stergiou GS et al (2008) European Society of Hypertension guidelines for blood pressure monitoring at home: a summary report of the Second International Consensus Conference on Home Blood Pressure Monitoring. J Hypertens 26:1505–1530PubMedCrossRef Parati G, Stergiou GS et al (2008) European Society of Hypertension guidelines for blood pressure monitoring at home: a summary report of the Second International Consensus Conference on Home Blood Pressure Monitoring. J Hypertens 26:1505–1530PubMedCrossRef
9.
Zurück zum Zitat Solà J, Vetter R, Renevey Ph, Chételat O, Sartori C, Rimoldi SF (2009) Parametric estimation of pulse arrival time: a robust approach to pulse wave velocity. Physiol Meas 30:603–615PubMedCrossRef Solà J, Vetter R, Renevey Ph, Chételat O, Sartori C, Rimoldi SF (2009) Parametric estimation of pulse arrival time: a robust approach to pulse wave velocity. Physiol Meas 30:603–615PubMedCrossRef
10.
Zurück zum Zitat Solà J, Rimoldi SF, Allemann Y (2010) Ambulatory monitoring of the cardiovascular system: the role of pulse wave velocity. In: Campolo D (ed) New developments in biomedical engineering. I-Tech Education and Publishing, Vienna Solà J, Rimoldi SF, Allemann Y (2010) Ambulatory monitoring of the cardiovascular system: the role of pulse wave velocity. In: Campolo D (ed) New developments in biomedical engineering. I-Tech Education and Publishing, Vienna
Metadaten
Titel
Non-invasive monitoring of central blood pressure by electrical impedance tomography: first experimental evidence
verfasst von
Josep Solà
Andy Adler
Arnoldo Santos
Gerardo Tusman
Fernando Suárez Sipmann
Stephan H. Bohm
Publikationsdatum
01.04.2011
Verlag
Springer-Verlag
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 4/2011
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-011-0753-z

Weitere Artikel der Ausgabe 4/2011

Medical & Biological Engineering & Computing 4/2011 Zur Ausgabe

Premium Partner