Skip to main content
Erschienen in: Experiments in Fluids 6/2016

01.06.2016 | Letter

On the rheology of refractive-index-matched, non-Newtonian blood-analog fluids for PIV experiments

verfasst von: Mohammad Reza Najjari, Jessica A. Hinke, Kartik V. Bulusu, Michael W. Plesniak

Erschienen in: Experiments in Fluids | Ausgabe 6/2016

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Four commonly used refractive-index (RI)-matched Newtonian blood-analog fluids are reviewed, and different non-Newtonian blood-analogs, with RI of 1.372–1.495, are investigated. Sodium iodide (NaI), sodium thiocyanate (NaSCN) and potassium thiocyanate are used to adjust the RI of blood-analogs to that of test sections for minimizing optical distortions in particle image velocimetry data, and xanthan gum (XG) is added to the fluids to give them non-Newtonian properties (shear thinning and viscoelasticity). Our results support the general belief that adding NaI to Newtonian fluids matches the RI without changing the kinematic viscosity. However, in contrast to claims made in a few studies that did not measure rheology, our investigation revealed that adding NaI or NaSCN to XG-based non-Newtonian fluids changes the viscosity of the fluids considerably and reduces the shear-thinning property. Therefore, the RI of non-Newtonian blood-analog fluids with XG cannot be adjusted easily by varying the concentration of NaI or NaSCN and needs more careful rheological study.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Baldwin JT, Deutsch S, Geselowitz DB, Tarbell JM (1994) LDA measurements of mean velocity and Reynolds stress fields within an artificial heart ventricle. J Biomech Eng 116:190–200. doi:10.1115/1.2895719 CrossRef Baldwin JT, Deutsch S, Geselowitz DB, Tarbell JM (1994) LDA measurements of mean velocity and Reynolds stress fields within an artificial heart ventricle. J Biomech Eng 116:190–200. doi:10.​1115/​1.​2895719 CrossRef
Zurück zum Zitat Brookshier KA, Tarbell JM (1993) Evaluation of a transparent blood analog fluid: aqueous xanthan gum/glycerin. Biorheology 30:107–116 Brookshier KA, Tarbell JM (1993) Evaluation of a transparent blood analog fluid: aqueous xanthan gum/glycerin. Biorheology 30:107–116
Zurück zum Zitat Buchmann NA, Jermy MC (2007) Particle image velocimetry measurements of blood flow in a modeled carotid artery bifurcation BT. In: 16th Australasian fluid mechanics conference, 16AFMC, December 3, 2007–December 7, 2007. Proceedings of the 16th Australasian fluid mechanics conference 16AFMC, pp 60–67 Buchmann NA, Jermy MC (2007) Particle image velocimetry measurements of blood flow in a modeled carotid artery bifurcation BT. In: 16th Australasian fluid mechanics conference, 16AFMC, December 3, 2007–December 7, 2007. Proceedings of the 16th Australasian fluid mechanics conference 16AFMC, pp 60–67
Zurück zum Zitat Burgmann S, Große S, Schröder W, Roggenkamp J, Jansen S et al (2009) A refractive index-matched facility for fluid–structure interaction studies of pulsatile and oscillating flow in elastic vessels of adjustable compliance. Exp Fluids 47:865. doi:10.1007/s00348-009-0681-y CrossRef Burgmann S, Große S, Schröder W, Roggenkamp J, Jansen S et al (2009) A refractive index-matched facility for fluid–structure interaction studies of pulsatile and oscillating flow in elastic vessels of adjustable compliance. Exp Fluids 47:865. doi:10.​1007/​s00348-009-0681-y CrossRef
Zurück zum Zitat Geoghegan PH, Buchmann NA, Spence CJT, Moore S, Jermy M (2012) Fabrication of rigid and flexible refractive-index-matched flow phantoms for flow visualisation and optical flow measurements. Exp Fluids 52:1331–1347. doi:10.1007/s00348-011-1258-0 CrossRef Geoghegan PH, Buchmann NA, Spence CJT, Moore S, Jermy M (2012) Fabrication of rigid and flexible refractive-index-matched flow phantoms for flow visualisation and optical flow measurements. Exp Fluids 52:1331–1347. doi:10.​1007/​s00348-011-1258-0 CrossRef
Zurück zum Zitat Gijsen FJ, van de Vosse FN, Janssen JD (1999) The influence of the non-Newtonian properties of blood on the flow in large arteries: steady flow in a carotid bifurcation model. J Biomech 32:601–608. doi:10.1016/S0021-9290(99)00015-9 CrossRef Gijsen FJ, van de Vosse FN, Janssen JD (1999) The influence of the non-Newtonian properties of blood on the flow in large arteries: steady flow in a carotid bifurcation model. J Biomech 32:601–608. doi:10.​1016/​S0021-9290(99)00015-9 CrossRef
Zurück zum Zitat Kalke BR, Mantini EL, Kaster RL, Carlson RG, Lillehei CW (1967) Hemodynamic features of a double-leaflet prosthetic heart valve of new design. ASAIO J 13:105–110 Kalke BR, Mantini EL, Kaster RL, Carlson RG, Lillehei CW (1967) Hemodynamic features of a double-leaflet prosthetic heart valve of new design. ASAIO J 13:105–110
Zurück zum Zitat Keshavarz-Motamed Z, Garcia J, Gaillard E, Maftoon N, Di Labbio G et al (2014) Effect of coarctation of the aorta and bicuspid aortic valve on flow dynamics and turbulence in the aorta using particle image velocimetry. Exp Fluids 55:1696. doi:10.1007/s00348-014-1696-6 CrossRef Keshavarz-Motamed Z, Garcia J, Gaillard E, Maftoon N, Di Labbio G et al (2014) Effect of coarctation of the aorta and bicuspid aortic valve on flow dynamics and turbulence in the aorta using particle image velocimetry. Exp Fluids 55:1696. doi:10.​1007/​s00348-014-1696-6 CrossRef
Zurück zum Zitat Mann DE, Tarbell JM (1990) Flow of non-Newtonian blood analog fluids in rigid curved and straight artery models. Biorheology 27:711–733 Mann DE, Tarbell JM (1990) Flow of non-Newtonian blood analog fluids in rigid curved and straight artery models. Biorheology 27:711–733
Zurück zum Zitat Marx TI, Baldwin BR, Kittle CF (1959) A cardiovascular simulator for the evaluation of prosthetic aortic valves. J Thorac Cardiovasc Surg 38:412–418 Marx TI, Baldwin BR, Kittle CF (1959) A cardiovascular simulator for the evaluation of prosthetic aortic valves. J Thorac Cardiovasc Surg 38:412–418
Zurück zum Zitat Naiki T, Yanai Y, Hayabashi K (1995) Evaluation of high polymer solutions as blood analog fluid. J Jpn Soc Biorheol 9:84–89 Naiki T, Yanai Y, Hayabashi K (1995) Evaluation of high polymer solutions as blood analog fluid. J Jpn Soc Biorheol 9:84–89
Zurück zum Zitat Sousa PC, Pinho FT, Oliveira MSN, Alves MA (2011) Extensional flow of blood analog solutions in microfluidic devices. Biomicrofluidics. doi:10.1063/1.3567888 Sousa PC, Pinho FT, Oliveira MSN, Alves MA (2011) Extensional flow of blood analog solutions in microfluidic devices. Biomicrofluidics. doi:10.​1063/​1.​3567888
Zurück zum Zitat Thurston GB (1979) Rheological parameters for the viscosity, viscoelasticity and thixotropy of blood. Biorheology 16:149–162 Thurston GB (1979) Rheological parameters for the viscosity, viscoelasticity and thixotropy of blood. Biorheology 16:149–162
Zurück zum Zitat Vlastos G, Lerche D, Koch B, Samba O, Pohl M (1997) The effect of parallel combined steady and oscillatory shear flows on blood and polymer solutions. Rheol Acta 36:160–172CrossRef Vlastos G, Lerche D, Koch B, Samba O, Pohl M (1997) The effect of parallel combined steady and oscillatory shear flows on blood and polymer solutions. Rheol Acta 36:160–172CrossRef
Zurück zum Zitat Walker AM, Johnston CR, Rival DE (2014) On the characterization of a non-newtonian blood analog and its response to pulsatile flow downstream of a simplified stenosis. Ann Biomed Eng 42:97–109. doi:10.1007/s10439-013-0893-4 CrossRef Walker AM, Johnston CR, Rival DE (2014) On the characterization of a non-newtonian blood analog and its response to pulsatile flow downstream of a simplified stenosis. Ann Biomed Eng 42:97–109. doi:10.​1007/​s10439-013-0893-4 CrossRef
Metadaten
Titel
On the rheology of refractive-index-matched, non-Newtonian blood-analog fluids for PIV experiments
verfasst von
Mohammad Reza Najjari
Jessica A. Hinke
Kartik V. Bulusu
Michael W. Plesniak
Publikationsdatum
01.06.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Experiments in Fluids / Ausgabe 6/2016
Print ISSN: 0723-4864
Elektronische ISSN: 1432-1114
DOI
https://doi.org/10.1007/s00348-016-2185-x

Weitere Artikel der Ausgabe 6/2016

Experiments in Fluids 6/2016 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.