We present a novel microfabrication method for a tapered hollow metallic microneedle array and its complete microfluidic packaging for drug delivery and body fluid sampling applications. Backside exposure of SU-8 through a UV transparent substrate was investigated as a means of fabricating a dense array of tall (up to 400 μm) uniformly tapered SU-8 pillar structures with angles in the range of 3.1–5° on top of the SU-8 mesa. Conformal electroplating of metals on top of the array of the tapered SU-8 pillars, lapping of the tip of the metallic microneedles with planarizing polymer, and removal of the SU-8 sacrificial layers resulted in an array of tapered hollow metallic microneedles with a fluidic reservoir on the backside. A microfluidic interconnector assembly was designed and fabricated using SU-8 and conventionally machined PMMA in a way that it has a male interconnector, which directly fits into the fluidic reservoir of the microneedle array at one end and the other male interconnector, which provides fluidic interconnection to external devices at the other end. The fluid flow rate was measured and it showed 0.69 μL/s. per microneedle when the pressure of 6.89 KPa (1 psi) was applied.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Ahn C, Choi J, Beaucage G, Nevin J, Lee J, Puntambekar A, Lee J (2004) Disposable smart lab-on-a-chip for point-of-care clinical diagnostics. Proc IEEE 92:154–173CrossRef Ahn C, Choi J, Beaucage G, Nevin J, Lee J, Puntambekar A, Lee J (2004) Disposable smart lab-on-a-chip for point-of-care clinical diagnostics. Proc IEEE 92:154–173CrossRef
Zurück zum Zitat Davis S, Prausnitz M, Allen M (2003) Fabrication and characterization of laser micromachined hollow microneedles, Dig. In: Transducers’03, international conference on solid-state sensors and actuators, pp 1435–1438 Davis S, Prausnitz M, Allen M (2003) Fabrication and characterization of laser micromachined hollow microneedles, Dig. In: Transducers’03, international conference on solid-state sensors and actuators, pp 1435–1438
Zurück zum Zitat Gardeniers H, Luttge R, Berenschot E, de Boer M, Yeshurun S, Hefetz M, Oever R, Berg A (2003) Silicon micromachined hollow microneedles for transdermal liquid transport. J Microelectromech Syst 12:855–862CrossRef Gardeniers H, Luttge R, Berenschot E, de Boer M, Yeshurun S, Hefetz M, Oever R, Berg A (2003) Silicon micromachined hollow microneedles for transdermal liquid transport. J Microelectromech Syst 12:855–862CrossRef
Zurück zum Zitat Griss P, Stemme G (2003) Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer. J Microelectromech Syst 12:296–301CrossRef Griss P, Stemme G (2003) Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer. J Microelectromech Syst 12:296–301CrossRef
Zurück zum Zitat Henry S, McAllister D, Allen M, Prausnitz M (1998) Microfabricated microneedles: a novel approach to transdermal drug delivery. J Pharm Sci 87:922–925CrossRef Henry S, McAllister D, Allen M, Prausnitz M (1998) Microfabricated microneedles: a novel approach to transdermal drug delivery. J Pharm Sci 87:922–925CrossRef
Zurück zum Zitat Kim K, Park D, Lu H, Che W, Kim K, Lee J, Ahn C (2004) A tapered hollow metallic microneedle array using backside exposure of SU-8. J Micromech Microeng 14:597–603CrossRef Kim K, Park D, Lu H, Che W, Kim K, Lee J, Ahn C (2004) A tapered hollow metallic microneedle array using backside exposure of SU-8. J Micromech Microeng 14:597–603CrossRef
Zurück zum Zitat Lorentz H, Despont M, Fahrni N, LaBlance N, Renaud P, Vettiger P (1997) SU-8: a low-cost negative resist for MEMS. J Micromech Microeng 7:121–124CrossRef Lorentz H, Despont M, Fahrni N, LaBlance N, Renaud P, Vettiger P (1997) SU-8: a low-cost negative resist for MEMS. J Micromech Microeng 7:121–124CrossRef
Zurück zum Zitat Lorentz H, Despont M, Fahrni N, LaBlance N, Renaud P, Vettiger P (1998) High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS. Sensors and Actuators A 64:33–39CrossRef Lorentz H, Despont M, Fahrni N, LaBlance N, Renaud P, Vettiger P (1998) High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS. Sensors and Actuators A 64:33–39CrossRef
Zurück zum Zitat McAllister D, Cros F, Davis S, Matta L, Prausnitz M, Allen M (1999) Three-dimensional hollow microneedle and microtube arrays, Dig. In: Transducers’99, international conference on solid-state sensors and actuators, pp 1098–1101 McAllister D, Cros F, Davis S, Matta L, Prausnitz M, Allen M (1999) Three-dimensional hollow microneedle and microtube arrays, Dig. In: Transducers’99, international conference on solid-state sensors and actuators, pp 1098–1101
Zurück zum Zitat Moon S, Lee S (2005) A novel fabrication method of a microneedle array using inclined deep x-ray exposure. J Micromech Microeng 15:903–911CrossRef Moon S, Lee S (2005) A novel fabrication method of a microneedle array using inclined deep x-ray exposure. J Micromech Microeng 15:903–911CrossRef
Zurück zum Zitat Peterman M, Huie P, Bloom D, Fishman H (2003) Building thick photoresist structures from the bottom up. J Micromech Microeng 13:380–382CrossRef Peterman M, Huie P, Bloom D, Fishman H (2003) Building thick photoresist structures from the bottom up. J Micromech Microeng 13:380–382CrossRef
Zurück zum Zitat Stoeber B, Liepmann D (2005) Arrays of hollow out-of-plane microneedles for drug delivery. J Microelectromech Syst 14:472–479CrossRef Stoeber B, Liepmann D (2005) Arrays of hollow out-of-plane microneedles for drug delivery. J Microelectromech Syst 14:472–479CrossRef
Zurück zum Zitat Zhang J, Tan K, Hong G, Yang L, Gong H (2001) Polymerization optimization of SU-8 photoresist and its applications in microfluidic systems and MEMS. J Micromech Microeng 11:20–26CrossRef Zhang J, Tan K, Hong G, Yang L, Gong H (2001) Polymerization optimization of SU-8 photoresist and its applications in microfluidic systems and MEMS. J Micromech Microeng 11:20–26CrossRef
Zurück zum Zitat Zimmermann S, Fienbork D, Flounders A, Liepmann D (2004) In-device enzyme immobilization: wafer-level fabrication of an integrated glucose sensor. Sensors Actuat B 99:163–173CrossRef Zimmermann S, Fienbork D, Flounders A, Liepmann D (2004) In-device enzyme immobilization: wafer-level fabrication of an integrated glucose sensor. Sensors Actuat B 99:163–173CrossRef
Metadaten
Titel
High aspect ratio tapered hollow metallic microneedle arrays with microfluidic interconnector
verfasst von
Kabseog Kim
Jeong-Bong Lee
Publikationsdatum
01.02.2007
Verlag
Springer-Verlag
Erschienen in
Microsystem Technologies / Ausgabe 3-4/2007
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-006-0221-0

Weitere Artikel der Ausgabe 3-4/2007

Microsystem Technologies 3-4/2007 Zur Ausgabe

Neuer Inhalt