Skip to main content
Erschienen in: Microsystem Technologies 7/2013

01.07.2013 | Review Paper

Integrated microfluidic drug delivery devices: a component view

verfasst von: Mst. Fateha Samad, Abbas Z. Kouzani

Erschienen in: Microsystem Technologies | Ausgabe 7/2013

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Research on drug delivery devices is progressing rapidly with the main objective being the delivery of precise quantity of drugs into the target area of the body. A drug delivery device (DDD) needs to accurately control the flow rate of drug delivery and protects the body from undesired additional doses. An integrated microfluidic drug delivery device (IMDDD) is a miniature device that can regulate and monitor the delivery of the right amount of drug using micro-scale components. IMDDDs offer several advantages including ease of use, electro-chemical controllability, low power consumption, simplicity, fast fabrication, and good bio-compatibility. Various IMDDDs have been developed for treatment of cancer, cardiovascular disorder, eye and brain diseases, stress, and diabetes. This paper presents a generic architecture for IMDDDs, discusses the existing drug delivery methods, summarizes the specifications of the components, and identifies a number of performance evaluation parameters. The operation of IMDDDs is presented through fourteen potential internal components. In addition, recommendations on how enhance the design and fabrication process of IMDDDs are given.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Ashraf MW, Tayyaba S, Nisar A, Afzulpurkar N, Tuantranont A (2009) Coupledfield microfluidic analysis of integrated MEMS based device for transdermal drug delivery applications. In: IEEE 13th International Multitopic Conference, INMIC, pp. 1–6 Ashraf MW, Tayyaba S, Nisar A, Afzulpurkar N, Tuantranont A (2009) Coupledfield microfluidic analysis of integrated MEMS based device for transdermal drug delivery applications. In: IEEE 13th International Multitopic Conference, INMIC, pp. 1–6
Zurück zum Zitat Ashraf MW, Tayyaba S, Afzulpurkar N (2010) MEMS based polymeric drug delivery system. In: IEEE Conference on Automation Science and Engineering (CASE), pp. 192–7 Ashraf MW, Tayyaba S, Afzulpurkar N (2010) MEMS based polymeric drug delivery system. In: IEEE Conference on Automation Science and Engineering (CASE), pp. 192–7
Zurück zum Zitat Chang K-F, Tsai Y-C, Shih W-P, Yang L-J (2010) An electro-active nano-valve array for reusable drug delivery system. In: IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS). pp. 1039–42 Chang K-F, Tsai Y-C, Shih W-P, Yang L-J (2010) An electro-active nano-valve array for reusable drug delivery system. In: IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS). pp. 1039–42
Zurück zum Zitat Chen J, Chu M, Koulajian K, Wu XY, Giacca A, Sun Y (2009) pH-responsive drug-delivery devices for implantable applications. In: International Solid-State Sensors, Actuators and Microsystems Conference, TRANSDUCERS, pp. 1465–8 Chen J, Chu M, Koulajian K, Wu XY, Giacca A, Sun Y (2009) pH-responsive drug-delivery devices for implantable applications. In: International Solid-State Sensors, Actuators and Microsystems Conference, TRANSDUCERS, pp. 1465–8
Zurück zum Zitat Evans AT, Park JM, Chiravuri S, Gianchandani YB (2008) Dual drug delivery device for chronic pain management using micromachined elastic metal structures and silicon microvalves. In: IEEE 21st International Conference on Micro Electro Mechanical Systems, MEMS, pp 252–5 Evans AT, Park JM, Chiravuri S, Gianchandani YB (2008) Dual drug delivery device for chronic pain management using micromachined elastic metal structures and silicon microvalves. In: IEEE 21st International Conference on Micro Electro Mechanical Systems, MEMS, pp 252–5
Zurück zum Zitat Gensler H, Sheybani R, Po-Ying L, Lo R, Zhu S, Ken-Tye Y, Roy I, Prasad PN, Masood R, Sinha UK, Meng E (2010) Implantable MEMS drug delivery device for cancer radiation reduction. In: IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS), pp. 23–6 Gensler H, Sheybani R, Po-Ying L, Lo R, Zhu S, Ken-Tye Y, Roy I, Prasad PN, Masood R, Sinha UK, Meng E (2010) Implantable MEMS drug delivery device for cancer radiation reduction. In: IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS), pp. 23–6
Zurück zum Zitat Ghahremani M, Nabili M, Mahesh S, Ji L, Belyea D, Geist C, Zderic V, Zaghloul M (2010) Surface acoustic wave devices for ocular drug delivery. In: IEEE Ultrasonics Symposium (IUS), pp 872–5 Ghahremani M, Nabili M, Mahesh S, Ji L, Belyea D, Geist C, Zderic V, Zaghloul M (2010) Surface acoustic wave devices for ocular drug delivery. In: IEEE Ultrasonics Symposium (IUS), pp 872–5
Zurück zum Zitat Gutierrez CA, Sheybani R, Meng E (2011) Electrochemically-based dose measurement for closed-loop drug delivery applications. In: 16th International Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), pp 2839–2842 Gutierrez CA, Sheybani R, Meng E (2011) Electrochemically-based dose measurement for closed-loop drug delivery applications. In: 16th International Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), pp 2839–2842
Zurück zum Zitat Hirota Y, Mishima F, Akiyama Y, Nishijima S (2010) Drug delivery using an embedded ferromagnetic needle and external magnets. IEEE Trans Appl Supercond 20(3):826–828CrossRef Hirota Y, Mishima F, Akiyama Y, Nishijima S (2010) Drug delivery using an embedded ferromagnetic needle and external magnets. IEEE Trans Appl Supercond 20(3):826–828CrossRef
Zurück zum Zitat Hou Z, Lin C, Zhang Q (2010) Design of a smart transdermal insulin drug delivery system. In: 4th International Conference on Bioinformatics and Biomedical Engineering (iCBBE), pp. 1–4 Hou Z, Lin C, Zhang Q (2010) Design of a smart transdermal insulin drug delivery system. In: 4th International Conference on Bioinformatics and Biomedical Engineering (iCBBE), pp. 1–4
Zurück zum Zitat Li PY, Sheybani R, Kuo J, Meng E (2009) A parylene bellows electrochemical actuator for intraocular drug delivery. In: International Solid-State Sensors, Actuators and Microsystems Conference, TRANSDUCERS, pp 1461–1464 Li PY, Sheybani R, Kuo J, Meng E (2009) A parylene bellows electrochemical actuator for intraocular drug delivery. In: International Solid-State Sensors, Actuators and Microsystems Conference, TRANSDUCERS, pp 1461–1464
Zurück zum Zitat Huang P-L, Kuo P-H, Huang Y-J, Liao H-H, Yang Y-J J, Wang T, Wang Y-H, Lu S-S (2012) A controlled-release drug delivery system on a chip using electrolysis.IEEE Trans Ind Electron 59(3):1578–1587 Huang P-L, Kuo P-H, Huang Y-J, Liao H-H, Yang Y-J J, Wang T, Wang Y-H, Lu S-S (2012) A controlled-release drug delivery system on a chip using electrolysis.IEEE Trans Ind Electron 59(3):1578–1587
Zurück zum Zitat Lo R, Meng E (2009) In-plane bandpass regulation check valve in heat-shrink packaging for drug delivery. In: IEEE 22nd International Conference on Micro Electro Mechanical Systems, MEMS, pp 236–239 Lo R, Meng E (2009) In-plane bandpass regulation check valve in heat-shrink packaging for drug delivery. In: IEEE 22nd International Conference on Micro Electro Mechanical Systems, MEMS, pp 236–239
Zurück zum Zitat Mohanty SP, Ghai D, Kougianos E, Joshi B (2009) A universal level converter towards the realization of energy efficient implantable drug delivery nano-electro-mechanical-systems. In: Quality of electronic design, ISQED, pp 673–679 Mohanty SP, Ghai D, Kougianos E, Joshi B (2009) A universal level converter towards the realization of energy efficient implantable drug delivery nano-electro-mechanical-systems. In: Quality of electronic design, ISQED, pp 673–679
Zurück zum Zitat Pirmoradi FN, Jackson J, Burt H, Chiao M (2011) Delivery of an anti-cancer drug from a magnetically controlled MEMS device show cytotoxicity in PC3 and HUVEC cells. In: 16th International Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), pp 2831–2834 Pirmoradi FN, Jackson J, Burt H, Chiao M (2011) Delivery of an anti-cancer drug from a magnetically controlled MEMS device show cytotoxicity in PC3 and HUVEC cells. In: 16th International Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), pp 2831–2834
Zurück zum Zitat Rahimi S, Takahata K (2011) A wireless implantable drug delivery device with hydrogel microvalves controlled by field-frequency tuning. In: IEEE 24th International Conference on Micro Electro Mechanical Systems (MEMS), pp 1019–1022 Rahimi S, Takahata K (2011) A wireless implantable drug delivery device with hydrogel microvalves controlled by field-frequency tuning. In: IEEE 24th International Conference on Micro Electro Mechanical Systems (MEMS), pp 1019–1022
Zurück zum Zitat Roxhed N, Samel B, Nordquist L, Griss P, Stemme G (2008) Painless drug delivery through microneedle-based transdermal patches featuring active infusion. IEEE Trans Biomed Eng 55(3):1063–1071CrossRef Roxhed N, Samel B, Nordquist L, Griss P, Stemme G (2008) Painless drug delivery through microneedle-based transdermal patches featuring active infusion. IEEE Trans Biomed Eng 55(3):1063–1071CrossRef
Zurück zum Zitat Sheybani R, Gensler H, Meng E (2011) Rapid and repeated bolus drug delivery enabled by high efficiency electrochemical bellows actuators. In: 16th International Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), pp 490–493 Sheybani R, Gensler H, Meng E (2011) Rapid and repeated bolus drug delivery enabled by high efficiency electrochemical bellows actuators. In: 16th International Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), pp 490–493
Zurück zum Zitat Spieth S, Schumacher A, Kallenbach C, Messner S, Zengerle R (2010) Neuromedicator—a disposable drug delivery system with silicon microprobes for neural research. In: IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS), pp 983–6 Spieth S, Schumacher A, Kallenbach C, Messner S, Zengerle R (2010) Neuromedicator—a disposable drug delivery system with silicon microprobes for neural research. In: IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS), pp 983–6
Zurück zum Zitat Wang B, Ni J, Litvin Y, Pfaff DW, Lin Q (2012) A microfluidic approach to pulsatile delivery of drugs for neurobiological studies. J Microelectromech Syst 21(1):53–61CrossRef Wang B, Ni J, Litvin Y, Pfaff DW, Lin Q (2012) A microfluidic approach to pulsatile delivery of drugs for neurobiological studies. J Microelectromech Syst 21(1):53–61CrossRef
Zurück zum Zitat Yang H, Dong L (2010) Smart drug delivery using electrospun hollow nanofibers. In: IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS), pp 308–311 Yang H, Dong L (2010) Smart drug delivery using electrospun hollow nanofibers. In: IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS), pp 308–311
Zurück zum Zitat Cheng C-H, Chao C, Cheung N-Y, Xiao L, Yang M, Leung W (2008) A transcutaneous controlled magnetic microvalve based on iron-powder filled PDMS for implantable drug delivery systems. In: IEEE 3rd International Conference on Nano/Micro Engineered and Molecular Systems, NEMS, pp 1160–3 Cheng C-H, Chao C, Cheung N-Y, Xiao L, Yang M, Leung W (2008) A transcutaneous controlled magnetic microvalve based on iron-powder filled PDMS for implantable drug delivery systems. In: IEEE 3rd International Conference on Nano/Micro Engineered and Molecular Systems, NEMS, pp 1160–3
Zurück zum Zitat Yu H, Du R, Guo Y, Wang Y, Di S (2010) Fabrication of taper hollow metallic microneedle array for portable drug delivery system. In: IEEE 5th International Conference on Nano/Micro Engineered and Molecular Systems (NEMS), pp 676–679 Yu H, Du R, Guo Y, Wang Y, Di S (2010) Fabrication of taper hollow metallic microneedle array for portable drug delivery system. In: IEEE 5th International Conference on Nano/Micro Engineered and Molecular Systems (NEMS), pp 676–679
Metadaten
Titel
Integrated microfluidic drug delivery devices: a component view
verfasst von
Mst. Fateha Samad
Abbas Z. Kouzani
Publikationsdatum
01.07.2013
Verlag
Springer-Verlag
Erschienen in
Microsystem Technologies / Ausgabe 7/2013
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-013-1770-7

Weitere Artikel der Ausgabe 7/2013

Microsystem Technologies 7/2013 Zur Ausgabe

Neuer Inhalt