Skip to main content
Erschienen in: Acta Mechanica 9/2023

01.09.2023 | Original Paper

A novel nonlinear isolated rooftop tuned mass damper-inerter (IR-TMDI) system for seismic response mitigation of buildings

verfasst von: Komal Rajana, Agathoklis Giaralis

Erschienen in: Acta Mechanica | Ausgabe 9/2023

Einloggen, um Zugang zu erhalten

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This paper conceptualizes a novel passive vibration control system comprising a tuned mass damper-inerter (TMDI) contained within a seismically isolated rooftop and investigates numerically its effectiveness for seismic response mitigation of building structures. The working principle of the proposed isolated rooftop tuned mass damper-inerter (IR-TMDI) system relies on the yielding of typical elastomeric isolators (e.g. lead rubber bearings) under severe earthquake ground motions to create a flexible rooftop which, in turn, increases the efficacy of the TMDI for seismic vibrations suppression. Herein, a nonlinear mechanical model is considered to explore the potential of IR-TMDI whereby the primary building structure is taken as linear damped single-mode system, while the Bouc–Wen model is used to capture the nonlinear/hysteretic behaviour of the rooftop isolators. An equivalent linear system (ELS), derived through statistical linearization, is used to expedite the optimal IR-TMDI tuning for different isolated rooftop properties, inertance, and primary structure natural period. To this aim, white noise excitations with different intensities as well as Kanai–Tajimi excitations for different soil conditions are considered. It is found that tuning for maximizing TMDI seismic energy dissipation is more advantageous than tuning for minimizing primary structure displacement or acceleration response since it lowers deflection and force demands to the isolators and to the inerter. Further, significant primary structure displacement and acceleration reductions are achieved as the effective rooftop flexibility increases through reduction of the nominal strength of the isolators, which verifies the intended working principle of the IR-TMDI. This is also confirmed through response history analyses to the nonlinear model under benchmark recorded ground motions. Moreover, for IR-TMDI with sufficiently flexible isolators, improved seismic structural performance with concurrent reduced deflection and force demands at the isolators is shown for all considered stochastic excitations as the inertance scales-up, which is readily achievable technologically. Thus, it is concluded that the IR-TMDI mitigates effectively structural seismic response without requiring the inerter to span several floors, as suggested in previous studies, thus extending the TMDI applicability to both existing and low-rise new-built structures.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Berquist, M., De Pasquale, R., Frye, S., Gilani, A., Klembczyk, A., Lee, D., Malatesta, A., Metzger, J., Schneide, R., Smith, C., Taylor, D., Wang, S., Winters, C.: Fluid Viscous Dampers General Guidelines for Engineers Including a Brief History. Taylor Devices Inc, New York (2019) Berquist, M., De Pasquale, R., Frye, S., Gilani, A., Klembczyk, A., Lee, D., Malatesta, A., Metzger, J., Schneide, R., Smith, C., Taylor, D., Wang, S., Winters, C.: Fluid Viscous Dampers General Guidelines for Engineers Including a Brief History. Taylor Devices Inc, New York (2019)
3.
Zurück zum Zitat Brzeski, P., Perlikowski, P.: Effects of play and inerter nonlinearities on the performance of tuned mass damper. Nonlinear Dyn. 88, 1027–1041 (2017)CrossRef Brzeski, P., Perlikowski, P.: Effects of play and inerter nonlinearities on the performance of tuned mass damper. Nonlinear Dyn. 88, 1027–1041 (2017)CrossRef
4.
Zurück zum Zitat Clough, R., Penzien, J.: Dynamics of structures, 2nd edn. Mc Graw-Hill, NY (2003)MATH Clough, R., Penzien, J.: Dynamics of structures, 2nd edn. Mc Graw-Hill, NY (2003)MATH
5.
Zurück zum Zitat Charles, A., Dennis, J.E., Jr.: Analysis of generalized pattern searches. SIAM J. Optim. 13, 889–903 (2008)MathSciNetMATH Charles, A., Dennis, J.E., Jr.: Analysis of generalized pattern searches. SIAM J. Optim. 13, 889–903 (2008)MathSciNetMATH
6.
7.
Zurück zum Zitat Dai, J., Xu, Z., Gai, P.: Tuned mass-damper-inerter control of wind-induced vibration of flexible structures based on inerter location. Eng. Struct. 199, 109585 (2019)CrossRef Dai, J., Xu, Z., Gai, P.: Tuned mass-damper-inerter control of wind-induced vibration of flexible structures based on inerter location. Eng. Struct. 199, 109585 (2019)CrossRef
9.
Zurück zum Zitat De Angelis, M., Giaralis, A., Petrini, F., Pietrosanti, D.: Optimal tuning and assessment of inertial dampers with grounded inerter for vibration control of seismically excited base-isolated systems. Eng. Struct. 196, 109250 (2019)CrossRef De Angelis, M., Giaralis, A., Petrini, F., Pietrosanti, D.: Optimal tuning and assessment of inertial dampers with grounded inerter for vibration control of seismically excited base-isolated systems. Eng. Struct. 196, 109250 (2019)CrossRef
11.
Zurück zum Zitat De Domenico, D., Ricciardi, G., Zhang, R.: Optimal design and seismic performance of tuned fluid inerter applied to structures with friction pendulum isolators. Soil Dyn. Earthq. Eng. 132, 106099 (2020)CrossRef De Domenico, D., Ricciardi, G., Zhang, R.: Optimal design and seismic performance of tuned fluid inerter applied to structures with friction pendulum isolators. Soil Dyn. Earthq. Eng. 132, 106099 (2020)CrossRef
12.
Zurück zum Zitat Djerouni, S., Ounis, A., Elias, S., Abdeddaim, M., Rupakhety, R.: Optimization and performance assessment of tuned mass damper-inerter systems for control of buildings subjected to pulse-like ground motions. Structures 38, 139–156 (2022)CrossRef Djerouni, S., Ounis, A., Elias, S., Abdeddaim, M., Rupakhety, R.: Optimization and performance assessment of tuned mass damper-inerter systems for control of buildings subjected to pulse-like ground motions. Structures 38, 139–156 (2022)CrossRef
14.
Zurück zum Zitat Faiella, D., Mele, E.: Vibration characteristics and higher mode coupling in intermediate isolation systems (IIS): a parametric analysis. Bull. Earthq. Eng. 17, 4347–4387 (2019)CrossRef Faiella, D., Mele, E.: Vibration characteristics and higher mode coupling in intermediate isolation systems (IIS): a parametric analysis. Bull. Earthq. Eng. 17, 4347–4387 (2019)CrossRef
15.
Zurück zum Zitat Faiella, D., Mele, E.: Insights into inter-story isolation design through the analysis of two case studies. Eng. Struct. 215, 110660 (2020)CrossRef Faiella, D., Mele, E.: Insights into inter-story isolation design through the analysis of two case studies. Eng. Struct. 215, 110660 (2020)CrossRef
16.
Zurück zum Zitat Freddi, F., Galasso, C., Cremen, G., Dall’Asta, A., Di Sarno, L., Giaralis, A., Gutiérrez-Urzúa, F., Málaga-Chuquitaype, C., Mitoulis, S.A., Petrone, C., Sextos, A., Sousa, L., Tarbali, K., Tubaldi, E., Wardman, J., Woo, G.: Innovations in earthquake risk reduction for resilience: recent advances and challenges. Int. J. Disaster Risk Reduct. 60, 102267 (2021)CrossRef Freddi, F., Galasso, C., Cremen, G., Dall’Asta, A., Di Sarno, L., Giaralis, A., Gutiérrez-Urzúa, F., Málaga-Chuquitaype, C., Mitoulis, S.A., Petrone, C., Sextos, A., Sousa, L., Tarbali, K., Tubaldi, E., Wardman, J., Woo, G.: Innovations in earthquake risk reduction for resilience: recent advances and challenges. Int. J. Disaster Risk Reduct. 60, 102267 (2021)CrossRef
18.
Zurück zum Zitat Giaralis, A., Marian, L.: Use of inerter devices for weight reduction of tuned mass dampers for seismic protection of multistorey buildings: the tuned mass-damper-inerter (TMDI). In: Proceedings of SPIE on Active and Passive Smart Structures and Integrated Systems 2016 (March 20-24, 2016, Las Vegas, NV, USA), Vol9799-1G, (2016). https://doi.org/10.1117/12.2219324 Giaralis, A., Marian, L.: Use of inerter devices for weight reduction of tuned mass dampers for seismic protection of multistorey buildings: the tuned mass-damper-inerter (TMDI). In: Proceedings of SPIE on Active and Passive Smart Structures and Integrated Systems 2016 (March 20-24, 2016, Las Vegas, NV, USA), Vol9799-1G, (2016). https://​doi.​org/​10.​1117/​12.​2219324
19.
Zurück zum Zitat Giaralis, A., Petrini, F.: Wind-induced vibration mitigation in tall buildings using the tuned mass-damper-inerter (TMDI). J. Struct. Eng. ASCE 143(9), 04017127 (2017)CrossRef Giaralis, A., Petrini, F.: Wind-induced vibration mitigation in tall buildings using the tuned mass-damper-inerter (TMDI). J. Struct. Eng. ASCE 143(9), 04017127 (2017)CrossRef
21.
Zurück zum Zitat Gonzales-Buelga, A., Lazar, I.F., Jiang, J.Z., Neild, S.A., Inman, D.J.: Assessing the effect of nonlinearities on the performance of a tuned inerter damper. Struct. Control Health Monit. 24, e1879 (2017)CrossRef Gonzales-Buelga, A., Lazar, I.F., Jiang, J.Z., Neild, S.A., Inman, D.J.: Assessing the effect of nonlinearities on the performance of a tuned inerter damper. Struct. Control Health Monit. 24, e1879 (2017)CrossRef
23.
Zurück zum Zitat Javidialesaadi, A., Wierschem, N.E.: An inerter-enhanced nonlinear energy sink. Mech. Syst. Signal Process. 129, 449–454 (2019)CrossRef Javidialesaadi, A., Wierschem, N.E.: An inerter-enhanced nonlinear energy sink. Mech. Syst. Signal Process. 129, 449–454 (2019)CrossRef
24.
Zurück zum Zitat Ikhouane, F., Rodellar, J., Hurtado, J.E.: Analytical characterization of hysteresis loops described by the Bouc–Wen model. Mech. Adv. Mater. Struct. 13, 463–472 (2006)CrossRef Ikhouane, F., Rodellar, J., Hurtado, J.E.: Analytical characterization of hysteresis loops described by the Bouc–Wen model. Mech. Adv. Mater. Struct. 13, 463–472 (2006)CrossRef
26.
Zurück zum Zitat Li, Q.S., Zhi, L.H., Tuan, A.Y., Kao, C.S., Su, S.C., Wu, C.F.: Dynamic behavior of Taipei 101 tower: field measurement and numerical analysis. J. Struct. Eng. ASCE 137(1), 143–155 (2011)CrossRef Li, Q.S., Zhi, L.H., Tuan, A.Y., Kao, C.S., Su, S.C., Wu, C.F.: Dynamic behavior of Taipei 101 tower: field measurement and numerical analysis. J. Struct. Eng. ASCE 137(1), 143–155 (2011)CrossRef
27.
Zurück zum Zitat Marian, L., Giaralis, A.: Optimal design of inerter devices combined with TMDs for vibration control of buildings exposed to stochastic seismic excitations. In: Proceedings of the 11th International Conference on Structural Safety and Reliability for Integrating Structural Analysis, Risk and Reliability- ICOSSAR2013, New York, vol. 137, pp 1025–1032 (2013) Marian, L., Giaralis, A.: Optimal design of inerter devices combined with TMDs for vibration control of buildings exposed to stochastic seismic excitations. In: Proceedings of the 11th International Conference on Structural Safety and Reliability for Integrating Structural Analysis, Risk and Reliability- ICOSSAR2013, New York, vol. 137, pp 1025–1032 (2013)
30.
Zurück zum Zitat Mitseas, I.P., Kougioumtzoglou, I.A., Giaralis, A., Beer, M.: A novel stochastic linearization framework for seismic demand estimation of hysteretic MDOF systems subject to linear response spectra. Struct. Saf. 72, 84–98 (2018)CrossRef Mitseas, I.P., Kougioumtzoglou, I.A., Giaralis, A., Beer, M.: A novel stochastic linearization framework for seismic demand estimation of hysteretic MDOF systems subject to linear response spectra. Struct. Saf. 72, 84–98 (2018)CrossRef
32.
Zurück zum Zitat Nagarajaiah, S., Xiaohong, S.: Response of base-isolated USC hospital building in Northridge earthquake. J. Struct. Eng. 126(10), 1177–1186 (2000)CrossRef Nagarajaiah, S., Xiaohong, S.: Response of base-isolated USC hospital building in Northridge earthquake. J. Struct. Eng. 126(10), 1177–1186 (2000)CrossRef
33.
Zurück zum Zitat Nakamura, Y., Fukukita, A., Tamura, K., Yamazaki, I., Matsuoka, T., Hiramoto, K., Sunakoda, K.: Seismic response control using electromagnetic inertial mass dampers. Earthq. Eng. Struct. Dyn. 43(4), 507–527 (2014)CrossRef Nakamura, Y., Fukukita, A., Tamura, K., Yamazaki, I., Matsuoka, T., Hiramoto, K., Sunakoda, K.: Seismic response control using electromagnetic inertial mass dampers. Earthq. Eng. Struct. Dyn. 43(4), 507–527 (2014)CrossRef
34.
Zurück zum Zitat Nakaminami, S., Kida, H., Ikago, K., Inoue N. Dynamic testing of a full-scale hydraulic inerter-damper for the seismic protection of civil structures. In: 7th International conference on advances in experimental structural engineering, pp. 41–54 (2017).https://doi.org/10.7414/7aese.T1.55.2016. Nakaminami, S., Kida, H., Ikago, K., Inoue N. Dynamic testing of a full-scale hydraulic inerter-damper for the seismic protection of civil structures. In: 7th International conference on advances in experimental structural engineering, pp. 41–54 (2017).https://​doi.​org/​10.​7414/​7aese.​T1.​55.​2016.
39.
Zurück zum Zitat Pietrosanti, D., De Angelis, M., Giaralis, A.: Experimental seismic performance assessment and numerical modelling of nonlinear inerter Vibration absorber (iva)-equipped base isolated structures tested on shaking table. Earthq. Eng. Struct. Dyn. 50(10), 2732–2753 (2021). https://doi.org/10.1002/eqe.3469CrossRef Pietrosanti, D., De Angelis, M., Giaralis, A.: Experimental seismic performance assessment and numerical modelling of nonlinear inerter Vibration absorber (iva)-equipped base isolated structures tested on shaking table. Earthq. Eng. Struct. Dyn. 50(10), 2732–2753 (2021). https://​doi.​org/​10.​1002/​eqe.​3469CrossRef
40.
Zurück zum Zitat Rajana, K., Wang, Z., Giaralis, A.: Optimal design and assessment of tuned mass damper-inerter with nonlinear viscous damper in seismically excited multi-storey buildings. Bull. Earthq. Eng. 21, 1509–1539 (2023)CrossRef Rajana, K., Wang, Z., Giaralis, A.: Optimal design and assessment of tuned mass damper-inerter with nonlinear viscous damper in seismically excited multi-storey buildings. Bull. Earthq. Eng. 21, 1509–1539 (2023)CrossRef
42.
Zurück zum Zitat Roberts, J., Spanos, P.: Random vibration and statistical linearization. Dover Publications, New York (2003)MATH Roberts, J., Spanos, P.: Random vibration and statistical linearization. Dover Publications, New York (2003)MATH
43.
Zurück zum Zitat Ruiz, R., Taflanidis, A., Giaralis, A., Lopez-Garcia, D.: Risk-informed optimization of the tuned mass-damper-inerter (TMDI) for the seismic protection of multi-storey building structures. Eng. Struct. 177, 836–850 (2018)CrossRef Ruiz, R., Taflanidis, A., Giaralis, A., Lopez-Garcia, D.: Risk-informed optimization of the tuned mass-damper-inerter (TMDI) for the seismic protection of multi-storey building structures. Eng. Struct. 177, 836–850 (2018)CrossRef
48.
Zurück zum Zitat Soto, M.G., Adeli, H.: Tuned mass dampers. Arch. Comput. Methods Eng. 20, 419–431 (2013)CrossRef Soto, M.G., Adeli, H.: Tuned mass dampers. Arch. Comput. Methods Eng. 20, 419–431 (2013)CrossRef
49.
Zurück zum Zitat Spanos, P.D., Giaralis, A., Politis, N.P.: Time- frequency representation of earthquake accelerograms and inelastic structural response records using the adaptive chirplet decomposition and empirical mode decomposition. Soil Dyn. Earthq. Eng. 27, 675–689 (2007)CrossRef Spanos, P.D., Giaralis, A., Politis, N.P.: Time- frequency representation of earthquake accelerograms and inelastic structural response records using the adaptive chirplet decomposition and empirical mode decomposition. Soil Dyn. Earthq. Eng. 27, 675–689 (2007)CrossRef
50.
Zurück zum Zitat Spanos, P.D., Giaralis, A.: Third-order statistical linearization-based approach to derive equivalent linear properties of bilinear hysteretic systems for seismic response spectrum analysis. Struct. Saf. 44, 59–69 (2013)CrossRef Spanos, P.D., Giaralis, A.: Third-order statistical linearization-based approach to derive equivalent linear properties of bilinear hysteretic systems for seismic response spectrum analysis. Struct. Saf. 44, 59–69 (2013)CrossRef
52.
Zurück zum Zitat Tsiatas, G.C., Karatzia, D.A.: Reliability analysis of the Hysteretic Nonlinear Energy Sink in shock mitigation considering uncertainties. J. Vib. Control 26(23–24), 2261–2273 (2020)MathSciNetCrossRef Tsiatas, G.C., Karatzia, D.A.: Reliability analysis of the Hysteretic Nonlinear Energy Sink in shock mitigation considering uncertainties. J. Vib. Control 26(23–24), 2261–2273 (2020)MathSciNetCrossRef
53.
Zurück zum Zitat Tsiatas, G.C., Charalampakis, A.E., Tsopelas, P.: A comparative study of linear and nonlinear mass damping systems under seismic excitation. Eng. Struct. 219, 110926 (2020)CrossRef Tsiatas, G.C., Charalampakis, A.E., Tsopelas, P.: A comparative study of linear and nonlinear mass damping systems under seismic excitation. Eng. Struct. 219, 110926 (2020)CrossRef
54.
Zurück zum Zitat Uang, C., Bertero, V.: Use of energy as a design criterion in earthquake-resistant design. Technical Report UCB/EERC 88–18, Earthquake Engineering Research Center, University of California at Berkeley (1988) Uang, C., Bertero, V.: Use of energy as a design criterion in earthquake-resistant design. Technical Report UCB/EERC 88–18, Earthquake Engineering Research Center, University of California at Berkeley (1988)
55.
Zurück zum Zitat Vakakis, A.F., Gendelman, O.: Energy pumping in nonlinear mechanical oscillators: part II-resonance capture. J. Appl. Mech. 68(1), 42–48 (2001)MathSciNetCrossRefMATH Vakakis, A.F., Gendelman, O.: Energy pumping in nonlinear mechanical oscillators: part II-resonance capture. J. Appl. Mech. 68(1), 42–48 (2001)MathSciNetCrossRefMATH
56.
Zurück zum Zitat Villaverde, R.: Roof isolation system to reduce the seismic response of buildings: a preliminary assessment. Earthq. Spectra 14(3), 521–532 (1998)CrossRef Villaverde, R.: Roof isolation system to reduce the seismic response of buildings: a preliminary assessment. Earthq. Spectra 14(3), 521–532 (1998)CrossRef
60.
Zurück zum Zitat Wang, Z., Giaralis, A.: Enhanced motion control performance of the tuned mass damper inerter through primary structure shaping. Struct. Control Health Monit. 28(8), e2756 (2021)CrossRef Wang, Z., Giaralis, A.: Enhanced motion control performance of the tuned mass damper inerter through primary structure shaping. Struct. Control Health Monit. 28(8), e2756 (2021)CrossRef
61.
Zurück zum Zitat Warn, G.P., Ryan, K.L.: A review of seismic isolation for buildings: historical development and research needs. Buildings 2, 300–325 (2012)CrossRef Warn, G.P., Ryan, K.L.: A review of seismic isolation for buildings: historical development and research needs. Buildings 2, 300–325 (2012)CrossRef
64.
Zurück zum Zitat Whittle, J.K., Williams, M.S., Karavasilis, T.L., Blakeborough, A.: A comparison of viscous damper placement methods for improving seismic building design. J. Earthq. Eng. 16, 540–560 (2012)CrossRef Whittle, J.K., Williams, M.S., Karavasilis, T.L., Blakeborough, A.: A comparison of viscous damper placement methods for improving seismic building design. J. Earthq. Eng. 16, 540–560 (2012)CrossRef
65.
Zurück zum Zitat Wolff, E.D., Ipek, C., Constantinou, M.C., Tapan, M.: Effect of viscous damping devices on the response of seismically isolated structures. Earthq. Eng. Struct. Dyn. 44, 185–198 (2015)CrossRef Wolff, E.D., Ipek, C., Constantinou, M.C., Tapan, M.: Effect of viscous damping devices on the response of seismically isolated structures. Earthq. Eng. Struct. Dyn. 44, 185–198 (2015)CrossRef
67.
Zurück zum Zitat Zemp, R., De la Llera, J.C., Roschke, P.: Tall building vibration control using a TM-MR damper assembly: Experimental results and implementation. Earthq. Eng. Struct. Dyn. 40, 257–271 (2011)CrossRef Zemp, R., De la Llera, J.C., Roschke, P.: Tall building vibration control using a TM-MR damper assembly: Experimental results and implementation. Earthq. Eng. Struct. Dyn. 40, 257–271 (2011)CrossRef
Metadaten
Titel
A novel nonlinear isolated rooftop tuned mass damper-inerter (IR-TMDI) system for seismic response mitigation of buildings
verfasst von
Komal Rajana
Agathoklis Giaralis
Publikationsdatum
01.09.2023
Verlag
Springer Vienna
Erschienen in
Acta Mechanica / Ausgabe 9/2023
Print ISSN: 0001-5970
Elektronische ISSN: 1619-6937
DOI
https://doi.org/10.1007/s00707-023-03556-9

Weitere Artikel der Ausgabe 9/2023

Acta Mechanica 9/2023 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.