Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 1/2009

01.01.2009 | Original Article

Spatial synchronization of an insole pressure distribution system with a 3D motion analysis system for center of pressure measurements

verfasst von: Laetitia Fradet, Johannes Siegel, Marieke Dahl, Merkur Alimusaj, Sebastian I. Wolf

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 1/2009

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Insole pressure systems are often more appropriate than force platforms for analysing center of pressure (CoP) as they are more flexible in use and indicate the position of the CoP that characterizes the contact foot/shoe during gait with shoes. However, these systems are typically not synchronized with 3D motion analysis systems. The present paper proposes a direct method that does not require a force platform for synchronizing an insole pressure system with a 3D motion analysis system. The distance separating 24 different CoPs measured optically and their equivalents measured by the insoles and transformed in the global coordinate system did not exceed 2 mm, confirming the suitability of the method proposed. Additionally, during static single limb stance, distances smaller than 7 mm and correlations higher than 0.94 were found between CoP trajectories measured with insoles and force platforms. Similar measurements were performed during gait to illustrate the characteristics of the CoP measured with each system. The distance separating the two CoPs was below 19 mm and the coefficient of correlation above 0.86. The proposed method offers the possibility to conduct new experiments, such as the investigation of proprioception in climbing stairs or in the presence of obstacles.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat Chapdelaine S, McFadyen BJ, Nadeau S, St Vincent G, Langelier E (2005) Instrumented staircase for kinetic analyses of upper- and lower-limb function during stair gait. Med Biol Eng Comput 43:552–556. doi:10.1007/BF02351027 CrossRef Chapdelaine S, McFadyen BJ, Nadeau S, St Vincent G, Langelier E (2005) Instrumented staircase for kinetic analyses of upper- and lower-limb function during stair gait. Med Biol Eng Comput 43:552–556. doi:10.​1007/​BF02351027 CrossRef
3.
Zurück zum Zitat Chen B, Bates BT (2000) Comparison of F-Scan in-sole and AMTI forceplate system in measuring vertical ground reaction force during gait. Physiother Theory Pract 16:43–53. doi:10.1080/095939800307601 CrossRef Chen B, Bates BT (2000) Comparison of F-Scan in-sole and AMTI forceplate system in measuring vertical ground reaction force during gait. Physiother Theory Pract 16:43–53. doi:10.​1080/​095939800307601 CrossRef
4.
Zurück zum Zitat Chesnin KJ, Selby-Silverstein L, Besser MP (2000) Comparison of an in-shoe pressure measurement device to a force plate: concurrent validity of center of pressure measurements. Gait Posture 12:128–133. doi:10.1016/S0966-6362(00)00071-0 CrossRef Chesnin KJ, Selby-Silverstein L, Besser MP (2000) Comparison of an in-shoe pressure measurement device to a force plate: concurrent validity of center of pressure measurements. Gait Posture 12:128–133. doi:10.​1016/​S0966-6362(00)00071-0 CrossRef
6.
Zurück zum Zitat Chumanov ES, Remy CD, Thelen DG (2007) Tracking the position of insole pressure sensors during walking and running. In: Proceedings from the 30th annual meeting of the american society of biomechanics, Stanford University, CA Chumanov ES, Remy CD, Thelen DG (2007) Tracking the position of insole pressure sensors during walking and running. In: Proceedings from the 30th annual meeting of the american society of biomechanics, Stanford University, CA
7.
Zurück zum Zitat Davis BL, Cothren RM, Quesada P, Hanson SB, Perry JE (1996) Frequency content of normal and diabetic plantar pressure profiles: implications for the selection of transducer sizes. J Biomech 29:979–983. doi:10.1016/0021-9290(95)00116-6 CrossRef Davis BL, Cothren RM, Quesada P, Hanson SB, Perry JE (1996) Frequency content of normal and diabetic plantar pressure profiles: implications for the selection of transducer sizes. J Biomech 29:979–983. doi:10.​1016/​0021-9290(95)00116-6 CrossRef
16.
Zurück zum Zitat Moreno JC, Brunetti F, Rocon E, Pons JL (2008) Immediate effects of a controllable knee ankle foot orthosis for functional compensation of gait in patients with proximal leg weakness. Med Biol Eng Comput 46:43–53. doi:10.1007/s11517-007-0267-x CrossRef Moreno JC, Brunetti F, Rocon E, Pons JL (2008) Immediate effects of a controllable knee ankle foot orthosis for functional compensation of gait in patients with proximal leg weakness. Med Biol Eng Comput 46:43–53. doi:10.​1007/​s11517-007-0267-x CrossRef
19.
Zurück zum Zitat Riener R, Rabuffetti M, Frigo C, Quintern J, Schmidt G (1999) Instrumented staircase for ground reaction measurement. Med Biol Eng Comput 37:526–529. doi:10.1007/BF02513341 CrossRef Riener R, Rabuffetti M, Frigo C, Quintern J, Schmidt G (1999) Instrumented staircase for ground reaction measurement. Med Biol Eng Comput 37:526–529. doi:10.​1007/​BF02513341 CrossRef
21.
Zurück zum Zitat Schmiedmayer HB, Kastner J (2000) Enhancements in the accuracy of the center of pressure (COP) determined with piezoelectric force plates are dependent on the load distribution. J Biomech Eng 122:523–527. doi:10.1115/1.1289687 CrossRef Schmiedmayer HB, Kastner J (2000) Enhancements in the accuracy of the center of pressure (COP) determined with piezoelectric force plates are dependent on the load distribution. J Biomech Eng 122:523–527. doi:10.​1115/​1.​1289687 CrossRef
22.
Zurück zum Zitat Yu B, Growney ES, Schultz FM, An KN (1996) Calibration of measured center of pressure of a new stairway design for kinetic analysis of stair climbing. J Biomech 29:1625–1628 Yu B, Growney ES, Schultz FM, An KN (1996) Calibration of measured center of pressure of a new stairway design for kinetic analysis of stair climbing. J Biomech 29:1625–1628
Metadaten
Titel
Spatial synchronization of an insole pressure distribution system with a 3D motion analysis system for center of pressure measurements
verfasst von
Laetitia Fradet
Johannes Siegel
Marieke Dahl
Merkur Alimusaj
Sebastian I. Wolf
Publikationsdatum
01.01.2009
Verlag
Springer-Verlag
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 1/2009
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-008-0382-3

Weitere Artikel der Ausgabe 1/2009

Medical & Biological Engineering & Computing 1/2009 Zur Ausgabe

Premium Partner