Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 6/2010

01.06.2010 | Original Article

Fully automatic initialization method for quantitative assessment of chest-wall deformity in funnel chest patients

verfasst von: Ho Chul Kim, Hyung Joo Park, Kyoung Won Nam, Soo Min Kim, Eun Jeong Choi, Seungoh Jin, Jae-Jo Lee, Sang Woo Park, Hyuk Choi, Min Gi Kim

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 6/2010

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In our previous study, we developed a computerized technique that measured degree of chest-wall deformity in funnel chest patients using several image processing techniques, such as, active contour model. It could calculate quantitative indices for chest-wall deformity using patient’s CT image. However, the algorithm contained manual initialization processes that required clinicians to obtain additional training processes to understand engineering contents and be familiar with the technique. In this study, we suggested a fully automatic algorithm that can measure the degree of chest-wall deformity by automating initialization processes. The initialization processes to segment CT images were automated by applying various image processing techniques such as histogram analysis, point detection, and object recognition. In order to evaluate the performance of the proposed algorithm, both the previous algorithm (semi-automatic) and newly suggested algorithm (fully automatic) were applied to preoperative CT images of 61 funnel chest patients to calculate several indices that represented chest-wall deformity quantitatively and to measure their processing time of our algorithm using a computer. The time required for initialization processes was 28.12 s using the semi-automatic algorithm and 0.07 s using the fully automatic algorithm (99.75% speed enhancement) and the time required for whole index calculation process was 61.12 s in semi-automatic algorithm and 30.09 s in fully automatic algorithm (50.76% speed enhancement). In most indices, calculation results of the two algorithms showed no significant difference between each other. The proposed algorithm could calculate chest-wall deformity more accurately with relatively shorter processing time than our previous method. Applying this algorithm is expected to facilitate more efficient diagnosis and evaluation processes of funnel chest patients for clinical doctors.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Chang PY, Hsu ZY, Lai JY, Wang CJ, Ching YT (2010) Increase in intrathoracic volume in pectus excavatum patients after the Nuss procedure. Med Biol Eng Comput 48:133–137CrossRefPubMed Chang PY, Hsu ZY, Lai JY, Wang CJ, Ching YT (2010) Increase in intrathoracic volume in pectus excavatum patients after the Nuss procedure. Med Biol Eng Comput 48:133–137CrossRefPubMed
2.
Zurück zum Zitat de Matos AC, Bernardo JE, Fernandes LE, Antunes MJ (1997) Surgery of chest wall deformities. Eur J Cardiothorac Surg 12:345–350CrossRefPubMed de Matos AC, Bernardo JE, Fernandes LE, Antunes MJ (1997) Surgery of chest wall deformities. Eur J Cardiothorac Surg 12:345–350CrossRefPubMed
3.
Zurück zum Zitat Donnelly LF, Frush DP (1999) Abnormalities of the chest wall in pediatric patients. AJR Am J Roentgenol 173:1595–1601PubMed Donnelly LF, Frush DP (1999) Abnormalities of the chest wall in pediatric patients. AJR Am J Roentgenol 173:1595–1601PubMed
4.
5.
Zurück zum Zitat Haller JA Jr, Kramer SS, Lietman SA (1987) Use of CT scans in selection of patients for pectus excavatum surgery: a preliminary report. J Pediatr Surg 22:904–906CrossRefPubMed Haller JA Jr, Kramer SS, Lietman SA (1987) Use of CT scans in selection of patients for pectus excavatum surgery: a preliminary report. J Pediatr Surg 22:904–906CrossRefPubMed
6.
Zurück zum Zitat Haller JA Jr, Scherer LR, Turner CS, Colombani PM (1989) Evolving management of pectus excavatum based on a single institutional experience of 664 patients. Ann Surg 209:578–582 discussion 82-3CrossRefPubMed Haller JA Jr, Scherer LR, Turner CS, Colombani PM (1989) Evolving management of pectus excavatum based on a single institutional experience of 664 patients. Ann Surg 209:578–582 discussion 82-3CrossRefPubMed
7.
Zurück zum Zitat Kass M, Witkin A, Terzopoulos D (1988) Snakes: active contour models. Int J Comput Vis 1:321–331CrossRef Kass M, Witkin A, Terzopoulos D (1988) Snakes: active contour models. Int J Comput Vis 1:321–331CrossRef
8.
Zurück zum Zitat Kim HC, Park HJ, Ham SY, Nam KW, Choi SY, Oh JS et al (2008) Development of automatized new indices for radiological assessment of chest-wall deformity and its quantitative evaluation. Med Biol Eng Comput 46:815–823CrossRefPubMed Kim HC, Park HJ, Ham SY, Nam KW, Choi SY, Oh JS et al (2008) Development of automatized new indices for radiological assessment of chest-wall deformity and its quantitative evaluation. Med Biol Eng Comput 46:815–823CrossRefPubMed
9.
Zurück zum Zitat Lee CS, Park HJ, Lee SY (2004) New computerized tomogram (CT) indices for pectus excavatum: tools for assessing modified techniques for asymmetry in Nuss repair. Chest Suppl 126(4):777s Lee CS, Park HJ, Lee SY (2004) New computerized tomogram (CT) indices for pectus excavatum: tools for assessing modified techniques for asymmetry in Nuss repair. Chest Suppl 126(4):777s
10.
Zurück zum Zitat Li B, Acton S (2008) Automatic active model initialization via Poisson inverse gradient. IEEE Trans Image Process 17:1406–1420CrossRefPubMed Li B, Acton S (2008) Automatic active model initialization via Poisson inverse gradient. IEEE Trans Image Process 17:1406–1420CrossRefPubMed
11.
Zurück zum Zitat Li C, Liu J, Fox M (2005) Segmentation of external force field for automatic initialization and splitting of snakes. Pattern Recognit 38:1947–1960CrossRef Li C, Liu J, Fox M (2005) Segmentation of external force field for automatic initialization and splitting of snakes. Pattern Recognit 38:1947–1960CrossRef
12.
Zurück zum Zitat Ohno K, Nakahira M, Takeuchi S, Shiokawa C, Moriuchi T, Harumoto K et al (2001) Indications for surgical treatment of funnel chest by chest radiograph. Pediatr Surg Int 17:591–595CrossRefPubMed Ohno K, Nakahira M, Takeuchi S, Shiokawa C, Moriuchi T, Harumoto K et al (2001) Indications for surgical treatment of funnel chest by chest radiograph. Pediatr Surg Int 17:591–595CrossRefPubMed
13.
Zurück zum Zitat Ohno K, Morotomi Y, Nakahira M, Takeuchi S, Shiokawa C, Moriuchi T et al (2003) Indications for surgical repair of funnel chest based on indices of chest wall deformity and psychological state. Surg Today 33:662–665CrossRefPubMed Ohno K, Morotomi Y, Nakahira M, Takeuchi S, Shiokawa C, Moriuchi T et al (2003) Indications for surgical repair of funnel chest based on indices of chest wall deformity and psychological state. Surg Today 33:662–665CrossRefPubMed
14.
Zurück zum Zitat Tauber C, Batatia H, Ayache A, CNRS Institute Toulouse France (2005) A general quasi-automatic initialization for snakes: application to ultrasound images. In: IEEE international conference on image processing, pp 806–809 Tauber C, Batatia H, Ayache A, CNRS Institute Toulouse France (2005) A general quasi-automatic initialization for snakes: application to ultrasound images. In: IEEE international conference on image processing, pp 806–809
15.
Zurück zum Zitat Xingfei G, Jie T (2002) An automatic active contour model for multiple objects. In: 16th International Conference on Pattern Recognition (ICPR’02), pp 881–884 Xingfei G, Jie T (2002) An automatic active contour model for multiple objects. In: 16th International Conference on Pattern Recognition (ICPR’02), pp 881–884
16.
Zurück zum Zitat Xu C, Prince JL (1998) Snakes, shapes, and gradient vector flow. IEEE Trans Image Process 7:359–369CrossRefPubMed Xu C, Prince JL (1998) Snakes, shapes, and gradient vector flow. IEEE Trans Image Process 7:359–369CrossRefPubMed
17.
Zurück zum Zitat Xu C, Prince JL (1998) Generalized gradient vector flow external forces for active contours. Signal Process 71:131–139CrossRef Xu C, Prince JL (1998) Generalized gradient vector flow external forces for active contours. Signal Process 71:131–139CrossRef
Metadaten
Titel
Fully automatic initialization method for quantitative assessment of chest-wall deformity in funnel chest patients
verfasst von
Ho Chul Kim
Hyung Joo Park
Kyoung Won Nam
Soo Min Kim
Eun Jeong Choi
Seungoh Jin
Jae-Jo Lee
Sang Woo Park
Hyuk Choi
Min Gi Kim
Publikationsdatum
01.06.2010
Verlag
Springer-Verlag
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 6/2010
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-010-0612-3

Weitere Artikel der Ausgabe 6/2010

Medical & Biological Engineering & Computing 6/2010 Zur Ausgabe

Premium Partner