Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 6/2015

01.06.2015 | Original Article

Correlation analysis of laser Doppler flowmetry signals: a potential non-invasive tool to assess microcirculatory changes in diabetes mellitus

verfasst von: Cerine Lal, Sujatha Narayanan Unni

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 6/2015

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Measurement and analysis of microcirculation is vital in assessing local and systemic tissue health. Changes in microvascular perfusion if detected can provide information on the development of various related diseases. Laser Doppler blood flowmetry (LDF) provides a non-invasive real-time measurement of cutaneous blood perfusion. LDF signals possess fractal nature that represents the correlation in the successive signal elements. Changes in the correlation of flow and its associated parameters could be used as a tool in differentiating the ailments at different stages or assessing the treatment effectiveness of a particular ailment. Spectral domain analysis of LDF signals reveals five characteristic frequency peaks corresponding to local and central regulatory mechanisms of the human body, namely metabolic, neurogenic, myogenic, respiration, and heart rate. This paper investigates the changes in the fractal nature and constituent frequency bands of laser Doppler signals in diabetic and healthy control subjects acquired from the glabrous skin of the foot so as to provide an assessment of microcirculatory dynamics. As a pilot study, it was attempted on a set of healthy control and diabetic volunteers, and the obtained results indicate that fractal nature of LDF signals is less in diabetic subjects compared to the healthy control. The wavelet analysis carried out on the set of signals reveals the dynamics of blood flow which may have led to the difference in correlation results.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat Arakelyan SM, Kucherik AO, Prokoshev VG, Troitskii DP, Shishkina MV (2010) Nonlinear signal processing of laser Doppler flowmetry records. Biomed Technol Radio Electron 7:29–32 Arakelyan SM, Kucherik AO, Prokoshev VG, Troitskii DP, Shishkina MV (2010) Nonlinear signal processing of laser Doppler flowmetry records. Biomed Technol Radio Electron 7:29–32
3.
4.
Zurück zum Zitat Barnes MD, Peppiatt TN, Mani R (1991) Glimpses into measurements of the microcirculation in skin. In: 30th Annual meeting of the biological engineering society, 18 Sept 1990–20 Sept 1990, Durham, NC, USA, J Biomed Eng, pp 185–188 Barnes MD, Peppiatt TN, Mani R (1991) Glimpses into measurements of the microcirculation in skin. In: 30th Annual meeting of the biological engineering society, 18 Sept 1990–20 Sept 1990, Durham, NC, USA, J Biomed Eng, pp 185–188
5.
Zurück zum Zitat Bernjak A, Stefanovska A, Urbancic-Rovan V, Azman-Juvan K (2005) Quantitative assessment of oscillatory components in blood circulation: classification of the effect of aging, diabetes, and acute myocardial infarction. In: Advanced biomedical and clinical diagnostic systems III, 23 Jan 2005, USA. Proceedings of the SPIE International Society Optics Engineering (USA). SPIE Int Soc Opt Eng, pp 163–173. doi:10.1117/12.589572 Bernjak A, Stefanovska A, Urbancic-Rovan V, Azman-Juvan K (2005) Quantitative assessment of oscillatory components in blood circulation: classification of the effect of aging, diabetes, and acute myocardial infarction. In: Advanced biomedical and clinical diagnostic systems III, 23 Jan 2005, USA. Proceedings of the SPIE International Society Optics Engineering (USA). SPIE Int Soc Opt Eng, pp 163–173. doi:10.​1117/​12.​589572
6.
Zurück zum Zitat Bondar IA, Klimontov VV, Korolyova EA (2002) Autonomic neuropathy in diabetes: early detection and the role in development of microvascular complications. In: Proceedings 6th Russian-Korean international symposium on science and technology, 24–30 June 2002, Piscataway, NJ, USA, Proceedings 6th Russian-Korean international symposium on science and technology. KORUS-2002 (Cat. No. 02EX565). IEEE, pp 464–467. doi:10.1109/KORUS.2002.1028065 Bondar IA, Klimontov VV, Korolyova EA (2002) Autonomic neuropathy in diabetes: early detection and the role in development of microvascular complications. In: Proceedings 6th Russian-Korean international symposium on science and technology, 24–30 June 2002, Piscataway, NJ, USA, Proceedings 6th Russian-Korean international symposium on science and technology. KORUS-2002 (Cat. No. 02EX565). IEEE, pp 464–467. doi:10.​1109/​KORUS.​2002.​1028065
9.
Zurück zum Zitat Briers JD (2001) Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging. Physiol Meas 22(4):R35–R66CrossRefPubMed Briers JD (2001) Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging. Physiol Meas 22(4):R35–R66CrossRefPubMed
11.
Zurück zum Zitat Campos R, Figueiras E, Ferreira LFR, Humeau-Heurtier A (2012) Spectral analysis of laser Doppler flowmetry signals. In: Bioengineering (ENBENG), 2012 IEEE 2nd Portuguese meeting in, 23–25 Feb 2012, pp 1–6. doi:10.1109/ENBENG.2012.6331342 Campos R, Figueiras E, Ferreira LFR, Humeau-Heurtier A (2012) Spectral analysis of laser Doppler flowmetry signals. In: Bioengineering (ENBENG), 2012 IEEE 2nd Portuguese meeting in, 23–25 Feb 2012, pp 1–6. doi:10.​1109/​ENBENG.​2012.​6331342
12.
Zurück zum Zitat Cannon MJ, Percival DB, Caccia DC, Raymond GM, Bassingthwaighte JB (1997) Evaluating scaled windowed variance methods for estimating the Hurst coefficient of time series. Phys A 241(3–4):606–626. doi:10.1016/s0378-4371(97)00252-5 CrossRef Cannon MJ, Percival DB, Caccia DC, Raymond GM, Bassingthwaighte JB (1997) Evaluating scaled windowed variance methods for estimating the Hurst coefficient of time series. Phys A 241(3–4):606–626. doi:10.​1016/​s0378-4371(97)00252-5 CrossRef
13.
Zurück zum Zitat Carolan-Rees G, Tweddel AC, Naka KK, Griffith TM (2002) Fractal dimensions of laser Doppler flowmetry time series. Med Eng Phys 24(1):71–76CrossRefPubMed Carolan-Rees G, Tweddel AC, Naka KK, Griffith TM (2002) Fractal dimensions of laser Doppler flowmetry time series. Med Eng Phys 24(1):71–76CrossRefPubMed
14.
Zurück zum Zitat Chih-Hui H, Eng-Kean Y, Kang-Ping L (2003) Portable laser Doppler flowmetry in studying the effect of diabetes mellitus on cutaneous microcirculation. J Med Biol Eng 23(1):13–18 Chih-Hui H, Eng-Kean Y, Kang-Ping L (2003) Portable laser Doppler flowmetry in studying the effect of diabetes mellitus on cutaneous microcirculation. J Med Biol Eng 23(1):13–18
17.
Zurück zum Zitat Eke A, Herman P, Bassingthwaighte JB, Raymond GM, Percival DB, Cannon M, Balla I, Ikrenyi C (2000) Physiological time series: distinguishing fractal noises from motions. Pflug Arch 439(4):403–415CrossRef Eke A, Herman P, Bassingthwaighte JB, Raymond GM, Percival DB, Cannon M, Balla I, Ikrenyi C (2000) Physiological time series: distinguishing fractal noises from motions. Pflug Arch 439(4):403–415CrossRef
18.
Zurück zum Zitat Eke A, Herman P, Kocsis L, Kozak LR (2002) Fractal characterization of complexity in temporal physiological signals. Physiol Meas 23(1):R1–R38CrossRefPubMed Eke A, Herman P, Kocsis L, Kozak LR (2002) Fractal characterization of complexity in temporal physiological signals. Physiol Meas 23(1):R1–R38CrossRefPubMed
20.
Zurück zum Zitat Glenny RW, Robertson HT, Yamashiro S, Bassingthwaighte JB (1991) Applications of fractal analysis to physiology. J Appl Physiol (Bethesda, MD: 1985) 70(6):2351–2367 Glenny RW, Robertson HT, Yamashiro S, Bassingthwaighte JB (1991) Applications of fractal analysis to physiology. J Appl Physiol (Bethesda, MD: 1985) 70(6):2351–2367
23.
Zurück zum Zitat Greenman RL, Panasyuk S, Wang X, Lyons TE, Dinh T, Longoria L, Giurini JM, Freeman J, Khaodhiar L, Veves A (2005) Early changes in the skin microcirculation and muscle metabolism of the diabetic foot. Lancet 366(9498):1711–1717. doi:10.1016/s0140-6736(05)67696-9 CrossRefPubMed Greenman RL, Panasyuk S, Wang X, Lyons TE, Dinh T, Longoria L, Giurini JM, Freeman J, Khaodhiar L, Veves A (2005) Early changes in the skin microcirculation and muscle metabolism of the diabetic foot. Lancet 366(9498):1711–1717. doi:10.​1016/​s0140-6736(05)67696-9 CrossRefPubMed
24.
Zurück zum Zitat IDF Diabetic Atlas (2013) 6th edition International Diabetes Federation IDF Diabetic Atlas (2013) 6th edition International Diabetes Federation
26.
Zurück zum Zitat Kalani M (2008) The importance of endothelin-1 for microvascular dysfunction in diabetes. Vasc Health Risk Manag 4(5):1061–1068PubMedCentralPubMed Kalani M (2008) The importance of endothelin-1 for microvascular dysfunction in diabetes. Vasc Health Risk Manag 4(5):1061–1068PubMedCentralPubMed
28.
Zurück zum Zitat Kun H, Peng CK, Huang NE, Zhaohua W, Lipsitz LA, Cavallerano J, Novak V (2008) Altered phase interactions between spontaneous blood pressure and flow fluctuations in type 2 diabetes mellitus: nonlinear assessment of cerebral autoregulation. Phys A 387(10):2279–2292. doi:10.1016/j.physa.2007.11.052 CrossRef Kun H, Peng CK, Huang NE, Zhaohua W, Lipsitz LA, Cavallerano J, Novak V (2008) Altered phase interactions between spontaneous blood pressure and flow fluctuations in type 2 diabetes mellitus: nonlinear assessment of cerebral autoregulation. Phys A 387(10):2279–2292. doi:10.​1016/​j.​physa.​2007.​11.​052 CrossRef
29.
Zurück zum Zitat Kvandal P, Stefanovska A, Veber M, Kvernmo HD, Kirkeboen KA (2003) Regulation of human cutaneous circulation evaluated by laser Doppler flowmetry, iontophoresis, and spectral analysis: importance of nitric oxide and prostaglandines. Microvasc Res 65(3):160–171CrossRefPubMed Kvandal P, Stefanovska A, Veber M, Kvernmo HD, Kirkeboen KA (2003) Regulation of human cutaneous circulation evaluated by laser Doppler flowmetry, iontophoresis, and spectral analysis: importance of nitric oxide and prostaglandines. Microvasc Res 65(3):160–171CrossRefPubMed
30.
31.
Zurück zum Zitat Liu D, Wood NB, Xu XY, Witt N, Hughes AD, Thom SA (2008) Image-based blood flow simulation in the retinal circulation. In: 4th European conference of the international federation for medical and biological engineering, ECIFMBE 2008, 23 Nov 2008–27 Nov 2008, Antwerp, Belgium, 2008. IFMBE Proceedings. Springer, Berlin, pp 1963–1966. doi:10.1007/978-3-540-89208-3_468 Liu D, Wood NB, Xu XY, Witt N, Hughes AD, Thom SA (2008) Image-based blood flow simulation in the retinal circulation. In: 4th European conference of the international federation for medical and biological engineering, ECIFMBE 2008, 23 Nov 2008–27 Nov 2008, Antwerp, Belgium, 2008. IFMBE Proceedings. Springer, Berlin, pp 1963–1966. doi:10.​1007/​978-3-540-89208-3_​468
32.
Zurück zum Zitat Meglinski IV Diffusing wave spectroscopy and its application for monitoring of skin blood microcirculation. In: Saratov Fall Meeting 2002 Optical Technologies in Biophysics and Medicine IV, 1 Oct 2002–4 Oct 2002, Saratov, Russia, 2002. Proceedings of SPIE—the International Society for Optical Engineering. SPIE, pp 163–169. doi:10.1117/12.518758 Meglinski IV Diffusing wave spectroscopy and its application for monitoring of skin blood microcirculation. In: Saratov Fall Meeting 2002 Optical Technologies in Biophysics and Medicine IV, 1 Oct 2002–4 Oct 2002, Saratov, Russia, 2002. Proceedings of SPIE—the International Society for Optical Engineering. SPIE, pp 163–169. doi:10.​1117/​12.​518758
33.
Zurück zum Zitat Obeid AN (1993) In vitro comparison of different signal processing algorithms used in laser Doppler flowmetry. Med Biol Eng Comput 31(1):43–52CrossRefPubMed Obeid AN (1993) In vitro comparison of different signal processing algorithms used in laser Doppler flowmetry. Med Biol Eng Comput 31(1):43–52CrossRefPubMed
34.
Zurück zum Zitat Peng CK, Havlin S, Stanley HE, Goldberger AL (1995) Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series. Chaos (Woodbury, NY) 5(1):82–87. doi:10.1063/1.166141 CrossRef Peng CK, Havlin S, Stanley HE, Goldberger AL (1995) Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series. Chaos (Woodbury, NY) 5(1):82–87. doi:10.​1063/​1.​166141 CrossRef
36.
Zurück zum Zitat Pieper GM (1998) Review of alterations in endothelial nitric oxide production in diabetes: protective role of arginine on endothelial dysfunction. Hypertension 31(5):1047–1060CrossRefPubMed Pieper GM (1998) Review of alterations in endothelial nitric oxide production in diabetes: protective role of arginine on endothelial dysfunction. Hypertension 31(5):1047–1060CrossRefPubMed
37.
Zurück zum Zitat Popivanov D, Mineva A, Bendayan P, Leger P, Boccalon H, Moller KO (1999) Dynamic characteristics of laser-Doppler flux in normal individuals and patients with Raynaud’s phenomenon before and after treatment with nifedipine under different thermal conditions. Technol Health Care 7(2/3):193–203PubMed Popivanov D, Mineva A, Bendayan P, Leger P, Boccalon H, Moller KO (1999) Dynamic characteristics of laser-Doppler flux in normal individuals and patients with Raynaud’s phenomenon before and after treatment with nifedipine under different thermal conditions. Technol Health Care 7(2/3):193–203PubMed
40.
Zurück zum Zitat Sanka SC, Bennett DC, Rojas JD, Tasby GB, Meininger CJ, Wu G, Wesson DE, Pfarr C, Martinez-Zaguilan R (2000) Ca2+ homeostasis in microvascular endothelial cells from an insulin dependent diabetic model: role of endosomes/lysosomes. In: Proceedings of SPIE—the International Society for Optical Engineering, vol 3924, pp 56–66 Sanka SC, Bennett DC, Rojas JD, Tasby GB, Meininger CJ, Wu G, Wesson DE, Pfarr C, Martinez-Zaguilan R (2000) Ca2+ homeostasis in microvascular endothelial cells from an insulin dependent diabetic model: role of endosomes/lysosomes. In: Proceedings of SPIE—the International Society for Optical Engineering, vol 3924, pp 56–66
42.
Zurück zum Zitat Shyh-Jier H, Cheng-Tao H, Ching-Lien H (1999) Application of Morlet wavelets to supervise power system disturbances. Power Deliv IEEE Trans 14(1):235–243. doi:10.1109/61.736728 CrossRef Shyh-Jier H, Cheng-Tao H, Ching-Lien H (1999) Application of Morlet wavelets to supervise power system disturbances. Power Deliv IEEE Trans 14(1):235–243. doi:10.​1109/​61.​736728 CrossRef
44.
Zurück zum Zitat Sokolnicki LA, Roberts SK, Wilkins BW, Basu A, Charkoudian N (2007) Contribution of nitric oxide to cutaneous microvascular dilation in individuals with type 2 diabetes mellitus. Am J Physiol Endocrinol Metab 292(1):E314–E318. doi:10.1152/ajpendo.00365.2006 CrossRefPubMed Sokolnicki LA, Roberts SK, Wilkins BW, Basu A, Charkoudian N (2007) Contribution of nitric oxide to cutaneous microvascular dilation in individuals with type 2 diabetes mellitus. Am J Physiol Endocrinol Metab 292(1):E314–E318. doi:10.​1152/​ajpendo.​00365.​2006 CrossRefPubMed
45.
Zurück zum Zitat Stefanovska A, Bracic M, Kvernmo HD (1999) Wavelet analysis of oscillations in the peripheral blood circulation measured by laser Doppler technique. IEEE Trans Bio-Med Eng 46(10):1230–1239CrossRef Stefanovska A, Bracic M, Kvernmo HD (1999) Wavelet analysis of oscillations in the peripheral blood circulation measured by laser Doppler technique. IEEE Trans Bio-Med Eng 46(10):1230–1239CrossRef
46.
Zurück zum Zitat Tooke JE (1996) Peripheral microvascular disease in diabetes. Diabetes Res Clin Pract 30(Suppl):61–65CrossRefPubMed Tooke JE (1996) Peripheral microvascular disease in diabetes. Diabetes Res Clin Pract 30(Suppl):61–65CrossRefPubMed
47.
Zurück zum Zitat Tsukada K, Hase K, Minamitani H, Sekizuka E, Oshio C (2001) Simultaneous measurement of blood flow distribution and oxygen tension by photoexcitation in organ microcirculation. Trans Inst Electr Eng Jpn Part C 121-C(9):1415–1421 Tsukada K, Hase K, Minamitani H, Sekizuka E, Oshio C (2001) Simultaneous measurement of blood flow distribution and oxygen tension by photoexcitation in organ microcirculation. Trans Inst Electr Eng Jpn Part C 121-C(9):1415–1421
48.
Zurück zum Zitat Veves A, Akbari CM, Primavera J, Donaghue VM, Zacharoulis D, Chrzan JS, DeGirolami U, LoGerfo FW, Freeman R (1998) Endothelial dysfunction and the expression of endothelial nitric oxide synthetase in diabetic neuropathy, vascular disease, and foot ulceration. Diabetes 47(3):457–463CrossRefPubMed Veves A, Akbari CM, Primavera J, Donaghue VM, Zacharoulis D, Chrzan JS, DeGirolami U, LoGerfo FW, Freeman R (1998) Endothelial dysfunction and the expression of endothelial nitric oxide synthetase in diabetic neuropathy, vascular disease, and foot ulceration. Diabetes 47(3):457–463CrossRefPubMed
49.
Zurück zum Zitat Vinik AI, Erbas T, Park TS, Stansberry KB, Scanelli JA, Pittenger GL (2001) Dermal neurovascular dysfunction in type 2 diabetes. Diabetes Care 24(8):1468–1475CrossRefPubMed Vinik AI, Erbas T, Park TS, Stansberry KB, Scanelli JA, Pittenger GL (2001) Dermal neurovascular dysfunction in type 2 diabetes. Diabetes Care 24(8):1468–1475CrossRefPubMed
50.
Zurück zum Zitat Ward JD, Boulton AJ, Simms JM, Sandler DA, Knight G (1983) Venous distension in the diabetic neuropathic foot (physical sign of arteriovenous shunting). J R Soc Med 76(12):1011–1014PubMedCentralPubMed Ward JD, Boulton AJ, Simms JM, Sandler DA, Knight G (1983) Venous distension in the diabetic neuropathic foot (physical sign of arteriovenous shunting). J R Soc Med 76(12):1011–1014PubMedCentralPubMed
51.
Zurück zum Zitat Williams SB, Cusco JA, Roddy MA, Johnstone MT, Creager MA (1996) Impaired nitric oxide-mediated vasodilation in patients with non-insulin-dependent diabetes mellitus. J Am Coll Cardiol 27(3):567–574CrossRefPubMed Williams SB, Cusco JA, Roddy MA, Johnstone MT, Creager MA (1996) Impaired nitric oxide-mediated vasodilation in patients with non-insulin-dependent diabetes mellitus. J Am Coll Cardiol 27(3):567–574CrossRefPubMed
52.
Zurück zum Zitat Yazdanfar S, Rollins AM, Izatt JA (2000) In vivo imaging of blood flow dynamics using color Doppler optical coherence tomography. In: Coherence domain optical methods in biomedical science and clinical applications IV, 24–26 Jan 2000, USA. Proceedings of the SPIE—International Society Optics Engineering (USA). SPIE Int Soc Opt Eng, pp 106–111. doi:10.1117/12.384146 Yazdanfar S, Rollins AM, Izatt JA (2000) In vivo imaging of blood flow dynamics using color Doppler optical coherence tomography. In: Coherence domain optical methods in biomedical science and clinical applications IV, 24–26 Jan 2000, USA. Proceedings of the SPIE—International Society Optics Engineering (USA). SPIE Int Soc Opt Eng, pp 106–111. doi:10.​1117/​12.​384146
Metadaten
Titel
Correlation analysis of laser Doppler flowmetry signals: a potential non-invasive tool to assess microcirculatory changes in diabetes mellitus
verfasst von
Cerine Lal
Sujatha Narayanan Unni
Publikationsdatum
01.06.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 6/2015
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-015-1266-y

Weitere Artikel der Ausgabe 6/2015

Medical & Biological Engineering & Computing 6/2015 Zur Ausgabe

Premium Partner