Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 1/2017

22.04.2016 | Original Article

A comparison of accuracy of fall detection algorithms (threshold-based vs. machine learning) using waist-mounted tri-axial accelerometer signals from a comprehensive set of falls and non-fall trials

verfasst von: Omar Aziz, Magnus Musngi, Edward J. Park, Greg Mori, Stephen N. Robinovitch

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 1/2017

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Falls are the leading cause of injury-related morbidity and mortality among older adults. Over 90 % of hip and wrist fractures and 60 % of traumatic brain injuries in older adults are due to falls. Another serious consequence of falls among older adults is the ‘long lie’ experienced by individuals who are unable to get up and remain on the ground for an extended period of time after a fall. Considerable research has been conducted over the past decade on the design of wearable sensor systems that can automatically detect falls and send an alert to care providers to reduce the frequency and severity of long lies. While most systems described to date incorporate threshold-based algorithms, machine learning algorithms may offer increased accuracy in detecting falls. In the current study, we compared the accuracy of these two approaches in detecting falls by conducting a comprehensive set of falling experiments with 10 young participants. Participants wore waist-mounted tri-axial accelerometers and simulated the most common causes of falls observed in older adults, along with near-falls and activities of daily living. The overall performance of five machine learning algorithms was greater than the performance of five threshold-based algorithms described in the literature, with support vector machines providing the highest combination of sensitivity and specificity.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat Arnold CM, Faulkner RA (2007) The history of falls and the association of the timed up and go test to falls and near-falls in older adults with hip osteoarthritis. BMC Geriatr 7:17CrossRefPubMedPubMedCentral Arnold CM, Faulkner RA (2007) The history of falls and the association of the timed up and go test to falls and near-falls in older adults with hip osteoarthritis. BMC Geriatr 7:17CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Aziz O, Park EJ, Mori G, Robinovitch SN (2012) Distinguishing near-falls from daily activities with wearable accelerometers and gyroscopes using support vector machines. In: Conference proceedings of IEEE engineering in medicine biology society 2012, pp 5837–5840 Aziz O, Park EJ, Mori G, Robinovitch SN (2012) Distinguishing near-falls from daily activities with wearable accelerometers and gyroscopes using support vector machines. In: Conference proceedings of IEEE engineering in medicine biology society 2012, pp 5837–5840
4.
Zurück zum Zitat Aziz O, Park EJ, Mori G, Robinovitch SN (2014) Distinguishing the causes of falls in humans using an array of wearable tri-axial accelerometers. Gait Posture 39(1):506–512CrossRefPubMed Aziz O, Park EJ, Mori G, Robinovitch SN (2014) Distinguishing the causes of falls in humans using an array of wearable tri-axial accelerometers. Gait Posture 39(1):506–512CrossRefPubMed
5.
Zurück zum Zitat Aziz O, Robinovitch SN (2011) An analysis of the accuracy of wearable sensors for classifying the causes of falls in humans. IEEE Trans Neural Syst Rehabil Eng 19(6):670–676CrossRefPubMedPubMedCentral Aziz O, Robinovitch SN (2011) An analysis of the accuracy of wearable sensors for classifying the causes of falls in humans. IEEE Trans Neural Syst Rehabil Eng 19(6):670–676CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Bagala F, Becker C, Cappello A, Chiari L, Aminian K, Hausdorff JM, Zijlstra W, Klenk J (2012) Evaluation of accelerometer-based fall detection algorithms on real-world falls. PLoS One 7(5):e37062CrossRefPubMedPubMedCentral Bagala F, Becker C, Cappello A, Chiari L, Aminian K, Hausdorff JM, Zijlstra W, Klenk J (2012) Evaluation of accelerometer-based fall detection algorithms on real-world falls. PLoS One 7(5):e37062CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Bourke AK, O'Brien JV, Lyons GM (2007) Evaluation of a threshold-based tri-axial accelerometer fall detection algorithm. Gait Posture 26(2):194–199CrossRefPubMed Bourke AK, O'Brien JV, Lyons GM (2007) Evaluation of a threshold-based tri-axial accelerometer fall detection algorithm. Gait Posture 26(2):194–199CrossRefPubMed
8.
Zurück zum Zitat Bourke AK, O'Donovan KJ, Olaighin G (2008) The identification of vertical velocity profiles using an inertial sensor to investigate pre-impact detection of falls. Med Eng Phys 30(7):937–946CrossRefPubMed Bourke AK, O'Donovan KJ, Olaighin G (2008) The identification of vertical velocity profiles using an inertial sensor to investigate pre-impact detection of falls. Med Eng Phys 30(7):937–946CrossRefPubMed
9.
Zurück zum Zitat Bourke AK, Scanaill CN, Culhane KM, Brien JVO, Lyons GM (2006) An optimum accelerometer configuration and simple algorithm for accurately detecting falls. In: Proceedings of the 24th IASTED international conference on Biomedical engineering. ACTA Press, Innsbruck Bourke AK, Scanaill CN, Culhane KM, Brien JVO, Lyons GM (2006) An optimum accelerometer configuration and simple algorithm for accurately detecting falls. In: Proceedings of the 24th IASTED international conference on Biomedical engineering. ACTA Press, Innsbruck
10.
Zurück zum Zitat Bourke AK, van de Ven P, Gamble M, O'Connor R, Murphy K, Bogan E, McQuade E, Finucane P, Olaighin G, Nelson J (2010) Evaluation of waist-mounted tri-axial accelerometer based fall-detection algorithms during scripted and continuous unscripted activities. J Biomech 43(15):3051–3057CrossRefPubMed Bourke AK, van de Ven P, Gamble M, O'Connor R, Murphy K, Bogan E, McQuade E, Finucane P, Olaighin G, Nelson J (2010) Evaluation of waist-mounted tri-axial accelerometer based fall-detection algorithms during scripted and continuous unscripted activities. J Biomech 43(15):3051–3057CrossRefPubMed
11.
Zurück zum Zitat Bourke AK, van de Ven PW, Chaya AE, GM OL, Nelson J (2008) Testing of a long-term fall detection system incorporated into a custom vest for the elderly. In: Conference Proceedings of IEEE engineering in medicine and biology society 2008, pp 2844–2847 Bourke AK, van de Ven PW, Chaya AE, GM OL, Nelson J (2008) Testing of a long-term fall detection system incorporated into a custom vest for the elderly. In: Conference Proceedings of IEEE engineering in medicine and biology society 2008, pp 2844–2847
12.
Zurück zum Zitat Boyle J, Karunanithi M (2008) Simulated fall detection via accelerometers. In: Conference Proceedings of IEEE engineering in medicine and biology society 2008, pp 1274–1277 Boyle J, Karunanithi M (2008) Simulated fall detection via accelerometers. In: Conference Proceedings of IEEE engineering in medicine and biology society 2008, pp 1274–1277
13.
Zurück zum Zitat Chao PK, Chan HL, Tang FT, Chen YC, Wong MK (2009) A comparison of automatic fall detection by the cross-product and magnitude of tri-axial acceleration. Physiol Meas 30(10):1027–1037CrossRefPubMed Chao PK, Chan HL, Tang FT, Chen YC, Wong MK (2009) A comparison of automatic fall detection by the cross-product and magnitude of tri-axial acceleration. Physiol Meas 30(10):1027–1037CrossRefPubMed
14.
Zurück zum Zitat Chen J, Kwong K, Chang D, Luk J, Bajcsy R (2005) Wearable sensors for reliable fall detection. In: Conference proceedings of IEEE engineering in medicine and biology society 4, pp 3551–3554 Chen J, Kwong K, Chang D, Luk J, Bajcsy R (2005) Wearable sensors for reliable fall detection. In: Conference proceedings of IEEE engineering in medicine and biology society 4, pp 3551–3554
15.
Zurück zum Zitat Diaz A, Prado M, Roa LM, Reina-Tosina J, Sanchez G (2004) Preliminary evaluation of a full-time falling monitor for the elderly. In: Conference proceedings of IEEE engineering in medicine and biology society 3, pp 2180–2183 Diaz A, Prado M, Roa LM, Reina-Tosina J, Sanchez G (2004) Preliminary evaluation of a full-time falling monitor for the elderly. In: Conference proceedings of IEEE engineering in medicine and biology society 3, pp 2180–2183
16.
Zurück zum Zitat Herman M, Gallagher E, Scott VJ (2006) The evolution of seniors falls prevention in British Columbia. BC Ministry of Health Services, Victoria Herman M, Gallagher E, Scott VJ (2006) The evolution of seniors falls prevention in British Columbia. BC Ministry of Health Services, Victoria
17.
Zurück zum Zitat Kangas M, Konttila A, Lindgren P, Winblad I, Jamsa T (2008) Comparison of low-complexity fall detection algorithms for body attached accelerometers. Gait Posture 28(2):285–291CrossRefPubMed Kangas M, Konttila A, Lindgren P, Winblad I, Jamsa T (2008) Comparison of low-complexity fall detection algorithms for body attached accelerometers. Gait Posture 28(2):285–291CrossRefPubMed
18.
Zurück zum Zitat Kau LJ, Chen CS (2015) A smart phone-based pocket fall accident detection, positioning, and rescue system. IEEE J Biomed Health Inform 19(1):44–56CrossRefPubMed Kau LJ, Chen CS (2015) A smart phone-based pocket fall accident detection, positioning, and rescue system. IEEE J Biomed Health Inform 19(1):44–56CrossRefPubMed
19.
Zurück zum Zitat Kern N, Schiele B, Schmidt A (2007) Recognizing context for annotating a live life recording. Personal Ubiquitous Comput. 11(4):251–263CrossRef Kern N, Schiele B, Schmidt A (2007) Recognizing context for annotating a live life recording. Personal Ubiquitous Comput. 11(4):251–263CrossRef
20.
Zurück zum Zitat King MB, Tinetti ME (1995) Falls in community-dwelling older persons. J Am Geriatr Soc 43(10):1146–1154CrossRefPubMed King MB, Tinetti ME (1995) Falls in community-dwelling older persons. J Am Geriatr Soc 43(10):1146–1154CrossRefPubMed
21.
Zurück zum Zitat Lee JK, Robinovitch SN, Park EJ (2015) Inertial sensing-based pre-impact detection of falls involving near-fall scenarios. IEEE Trans Neural Syst Rehabil Eng 23(2):258–266CrossRefPubMed Lee JK, Robinovitch SN, Park EJ (2015) Inertial sensing-based pre-impact detection of falls involving near-fall scenarios. IEEE Trans Neural Syst Rehabil Eng 23(2):258–266CrossRefPubMed
22.
Zurück zum Zitat Lindemann U, Hock A, Stuber M, Keck W, Becker C (2005) Evaluation of a fall detector based on accelerometers: a pilot study. Med Biol Eng Comput 43(5):548–551CrossRefPubMed Lindemann U, Hock A, Stuber M, Keck W, Becker C (2005) Evaluation of a fall detector based on accelerometers: a pilot study. Med Biol Eng Comput 43(5):548–551CrossRefPubMed
23.
Zurück zum Zitat Mallinson WJ, Green MF (1985) Covert muscle injury in aged patients admitted to hospital following falls. Age Ageing 14(3):174–178CrossRefPubMed Mallinson WJ, Green MF (1985) Covert muscle injury in aged patients admitted to hospital following falls. Age Ageing 14(3):174–178CrossRefPubMed
24.
Zurück zum Zitat Nevitt MC, Cummings SR, Kidd S, Black D (1989) Risk factors for recurrent nonsyncopal falls. A prospective study. JAMA 261(18):2663–2668CrossRefPubMed Nevitt MC, Cummings SR, Kidd S, Black D (1989) Risk factors for recurrent nonsyncopal falls. A prospective study. JAMA 261(18):2663–2668CrossRefPubMed
25.
Zurück zum Zitat Noury N, Galay A, Pasquier J, Ballussaud M (2008) Preliminary investigation into the use of autonomous fall detectors. In: Conference proceedings of IEEE engineering in medicine and biology society 2008, pp 2828–2831 Noury N, Galay A, Pasquier J, Ballussaud M (2008) Preliminary investigation into the use of autonomous fall detectors. In: Conference proceedings of IEEE engineering in medicine and biology society 2008, pp 2828–2831
26.
Zurück zum Zitat Noury N, Rumeau P, Bourke AK, ÓLaighin G, Lundy JE (2008) A proposal for the classification and evaluation of fall detectors. IRBM 29(6):340–349CrossRef Noury N, Rumeau P, Bourke AK, ÓLaighin G, Lundy JE (2008) A proposal for the classification and evaluation of fall detectors. IRBM 29(6):340–349CrossRef
27.
Zurück zum Zitat Robinovitch SN, Feldman F, Yang Y, Schonnop R, Leung PM, Sarraf T, Sims-Gould J, Loughin M (2013) Video capture of the circumstances of falls in elderly people residing in long-term care: an observational study. Lancet 381(9860):47–54CrossRefPubMed Robinovitch SN, Feldman F, Yang Y, Schonnop R, Leung PM, Sarraf T, Sims-Gould J, Loughin M (2013) Video capture of the circumstances of falls in elderly people residing in long-term care: an observational study. Lancet 381(9860):47–54CrossRefPubMed
28.
Zurück zum Zitat Srygley JM, Herman T, Giladi N, Hausdorff JM (2009) Self-report of missteps in older adults: a valid proxy of fall risk? Arch Phys Med Rehabil 90(5):786–792CrossRefPubMedPubMedCentral Srygley JM, Herman T, Giladi N, Hausdorff JM (2009) Self-report of missteps in older adults: a valid proxy of fall risk? Arch Phys Med Rehabil 90(5):786–792CrossRefPubMedPubMedCentral
29.
Zurück zum Zitat Tinetti ME, Williams CS (1998) The effect of falls and fall injuries on functioning in community-dwelling older persons. J Gerontol A Biol Sci Med Sci 53(2):M112–M119CrossRefPubMed Tinetti ME, Williams CS (1998) The effect of falls and fall injuries on functioning in community-dwelling older persons. J Gerontol A Biol Sci Med Sci 53(2):M112–M119CrossRefPubMed
30.
Zurück zum Zitat Vellas B, Cayla F, Bocquet H, de Pemille F, Albarede JL (1987) Prospective study of restriction of activity in old people after falls. Age Ageing 16(3):189–193CrossRefPubMed Vellas B, Cayla F, Bocquet H, de Pemille F, Albarede JL (1987) Prospective study of restriction of activity in old people after falls. Age Ageing 16(3):189–193CrossRefPubMed
31.
Zurück zum Zitat Weiss A, Shimkin I, Giladi N, Hausdorff JM (2010) Automated detection of near falls: algorithm development and preliminary results. BMC Res Notes 3:62CrossRefPubMedPubMedCentral Weiss A, Shimkin I, Giladi N, Hausdorff JM (2010) Automated detection of near falls: algorithm development and preliminary results. BMC Res Notes 3:62CrossRefPubMedPubMedCentral
32.
Zurück zum Zitat Weiss GM, Provost F (2003) Learning when training data are costly: the effect of class distribution on tree induction. J Artif Intell Res 19(1):315–354 Weiss GM, Provost F (2003) Learning when training data are costly: the effect of class distribution on tree induction. J Artif Intell Res 19(1):315–354
33.
Zurück zum Zitat Wild D, Nayak US, Isaacs B (1981) How dangerous are falls in old people at home? Br Med J (Clin Res Ed) 282(6260):266–268CrossRef Wild D, Nayak US, Isaacs B (1981) How dangerous are falls in old people at home? Br Med J (Clin Res Ed) 282(6260):266–268CrossRef
Metadaten
Titel
A comparison of accuracy of fall detection algorithms (threshold-based vs. machine learning) using waist-mounted tri-axial accelerometer signals from a comprehensive set of falls and non-fall trials
verfasst von
Omar Aziz
Magnus Musngi
Edward J. Park
Greg Mori
Stephen N. Robinovitch
Publikationsdatum
22.04.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 1/2017
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-016-1504-y

Weitere Artikel der Ausgabe 1/2017

Medical & Biological Engineering & Computing 1/2017 Zur Ausgabe

Premium Partner