Abstract

Ambulatory recording of physiological data will provide us deep insight into the physical condition of patients and athletes, and assessing treatment effects and training performances. This study presents a miniature wearable cardiopulmonary monitoring system called “Smart Chest Strap,” which consists of an elastic band worn around the user’s chest with integrated sensors, a physiological signals acquisition unit, and a mobile phone. The physiological signals including electrocardiogram, respiratory inductance plethysmograph, and accelerations (ACC) are sampled, digitalized, stored, and simultaneously transmitted to a mobile phone via Bluetooth. A medical validation test with participants performing discontinuous incremental treadmill (0–12 km/h) exercise was conducted. The results indicate nearly perfect correlations (0.999, 0.996, 0.994), small mean bias (0.60 BPM, 0.51 BPM, 0.05 g), and narrow limits of agreement (±2.90 BPM, ±1.81 BPM, ±0.09 g) for heart rate (HR), breathing rate (BR), and ACC represented as vector magnitude units (VMUs). There is a general trend of decrease in accuracy, precision, and correlation for HR, BR, and VMU as velocity increases, but these validity statistics are all within acceptable error limits and clinically accepted. The findings demonstrate that the Smart Chest Strap is valid and will have wider applications in healthcare, sports, and scientific research areas.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
7.
Zurück zum Zitat Goodrich S, Orr WC (2009) An investigation of the validity of the Lifeshirt in comparison to standard polysomnography in the detection of obstructive sleep apnea. Sleep Med 10:118–122CrossRefPubMed Goodrich S, Orr WC (2009) An investigation of the validity of the Lifeshirt in comparison to standard polysomnography in the detection of obstructive sleep apnea. Sleep Med 10:118–122CrossRefPubMed
10.
Zurück zum Zitat Johnstone JA, Ford PA, Hughes G, Watson T, Garrett AT (2012) Bioharness™ multivariable monitoring device: part. I: validity. J Sports Sci Med 11:400–408PubMedPubMedCentral Johnstone JA, Ford PA, Hughes G, Watson T, Garrett AT (2012) Bioharness™ multivariable monitoring device: part. I: validity. J Sports Sci Med 11:400–408PubMedPubMedCentral
11.
12.
Zurück zum Zitat Liu Y, Zhu SH, Wang GH, Ye F, Li PZ (2013) Validity and reliability of multiparameter physiological measurements recorded by the equivital lifemonitor during activities of various intensities. J Occup Environ Hyg 10:78–85. doi:10.1080/15459624.2012.747404 CrossRefPubMed Liu Y, Zhu SH, Wang GH, Ye F, Li PZ (2013) Validity and reliability of multiparameter physiological measurements recorded by the equivital lifemonitor during activities of various intensities. J Occup Environ Hyg 10:78–85. doi:10.​1080/​15459624.​2012.​747404 CrossRefPubMed
13.
Zurück zum Zitat Pandian PS, Mohanavelu K, Safeer KP, Kotresh TM, Shakunthala DT, Gopal P, Padaki VC (2008) Smart vest: wearable multi-parameter remote physiological monitoring system. Med Eng Phys 30:466–477CrossRefPubMed Pandian PS, Mohanavelu K, Safeer KP, Kotresh TM, Shakunthala DT, Gopal P, Padaki VC (2008) Smart vest: wearable multi-parameter remote physiological monitoring system. Med Eng Phys 30:466–477CrossRefPubMed
16.
Zurück zum Zitat Rowlands AV, Thomas PW, Eston RG, Topping R (2004) Validation of the RT3 triaxial accelerometer for the assessment of physical activity. Med Sci Sports Exerc 36:518–524CrossRefPubMed Rowlands AV, Thomas PW, Eston RG, Topping R (2004) Validation of the RT3 triaxial accelerometer for the assessment of physical activity. Med Sci Sports Exerc 36:518–524CrossRefPubMed
17.
Zurück zum Zitat Salhab M, Al Sarakbi W, Mokbel K (2005) The evolving role of the dynamic thermal analysis in the early detection of breast cancer. Int Semin Surg Oncol 2:8. doi:10.1186/1477-7800-2-8 Salhab M, Al Sarakbi W, Mokbel K (2005) The evolving role of the dynamic thermal analysis in the early detection of breast cancer. Int Semin Surg Oncol 2:8. doi:10.​1186/​1477-7800-2-8
18.
Zurück zum Zitat Sang Hyun K, Dong Wan R, Changseok B (2008) U-healthcare System using Smart Headband. In: Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE, 20–25 Aug. 2008. pp 1557–1560. doi:10.1109/iembs.2008.4649467 Sang Hyun K, Dong Wan R, Changseok B (2008) U-healthcare System using Smart Headband. In: Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE, 20–25 Aug. 2008. pp 1557–1560. doi:10.​1109/​iembs.​2008.​4649467
19.
Zurück zum Zitat Schulz S, Bär K-J, Voss A (2015) Analyses of heart rate, respiration and cardiorespiratory coupling in patients with schizophrenia. Entropy 17:483. doi:10.3390/e17020483 CrossRef Schulz S, Bär K-J, Voss A (2015) Analyses of heart rate, respiration and cardiorespiratory coupling in patients with schizophrenia. Entropy 17:483. doi:10.​3390/​e17020483 CrossRef
20.
Zurück zum Zitat Seoane F, Mohino-Herranz I, Ferreira J, Alvarez L, Buendia R, Ayllon D, Llerena C, Gil-Pita R (2014) Wearable biomedical measurement systems for assessment of mental stress of combatants in real time. Sensors (Basel) 14:7120–7141. doi:10.3390/s140407120 CrossRef Seoane F, Mohino-Herranz I, Ferreira J, Alvarez L, Buendia R, Ayllon D, Llerena C, Gil-Pita R (2014) Wearable biomedical measurement systems for assessment of mental stress of combatants in real time. Sensors (Basel) 14:7120–7141. doi:10.​3390/​s140407120 CrossRef
26.
Zurück zum Zitat Witt JD, Fisher JR, Guenette JA, Cheong KA, Wilson BJ, Sheel AW (2006) Measurement of exercise ventilation by a portable respiratory inductive plethysmograph. Respir Physiol Neurobiol 154:389–395CrossRefPubMed Witt JD, Fisher JR, Guenette JA, Cheong KA, Wilson BJ, Sheel AW (2006) Measurement of exercise ventilation by a portable respiratory inductive plethysmograph. Respir Physiol Neurobiol 154:389–395CrossRefPubMed
27.
Zurück zum Zitat Yang G, Xie L, Mantysalo M, Chen J, Tenhunen H, Zheng LR (2012) Bio-patch design and implementation based on a low-power system-on-chip and paper-based inkjet printing technology. IEEE Trans Inf Technol Biomed 16:1043–1050. doi:10.1109/TITB.2012.2204437 CrossRefPubMed Yang G, Xie L, Mantysalo M, Chen J, Tenhunen H, Zheng LR (2012) Bio-patch design and implementation based on a low-power system-on-chip and paper-based inkjet printing technology. IEEE Trans Inf Technol Biomed 16:1043–1050. doi:10.​1109/​TITB.​2012.​2204437 CrossRefPubMed
28.
29.
Zurück zum Zitat Zhang Z, Zheng J, Wu H, Wang W, Wang B, Liu H (2012) Development of a respiratory inductive plethysmography module supporting multiple sensors for wearable systems. Sensors (Basel) 12:13167–13184. doi:10.3390/s121013167 CrossRef Zhang Z, Zheng J, Wu H, Wang W, Wang B, Liu H (2012) Development of a respiratory inductive plethysmography module supporting multiple sensors for wearable systems. Sensors (Basel) 12:13167–13184. doi:10.​3390/​s121013167 CrossRef
30.
31.
Zurück zum Zitat Zheng J, Shen Y, Zhang Z, Wu T-H, Zhang G, Lu H (2013) Emerging Wearable Medical Devices towards Personalized Healthcare. In: Proceedings of the 8th International Conference on Body Area Networks, Brussels, Belgium, pp 427–431. doi:10.4108/icst.bodynets.2013.253725 Zheng J, Shen Y, Zhang Z, Wu T-H, Zhang G, Lu H (2013) Emerging Wearable Medical Devices towards Personalized Healthcare. In: Proceedings of the 8th International Conference on Body Area Networks, Brussels, Belgium, pp 427–431. doi:10.​4108/​icst.​bodynets.​2013.​253725
Metadaten
Titel
Design and evaluation of a ubiquitous chest-worn cardiopulmonary monitoring system for healthcare application: a pilot study
verfasst von
Jiewen Zheng
Congying Ha
Zhengbo Zhang
Publikationsdatum
13.05.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 2/2017
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-016-1518-5

Weitere Artikel der Ausgabe 2/2017

Medical & Biological Engineering & Computing 2/2017 Zur Ausgabe

Premium Partner