Purpose

Patient immobilization and X-ray-based imaging provide neither a convenient nor a very accurate way to ensure low repositioning errors or to compensate for motion in cranial radiotherapy. We therefore propose an optical tracking device that exploits subcutaneous structures as landmarks in addition to merely spatial registration. To develop such head tracking algorithms, precise and robust computation of these structures is necessary. Here, we show that the tissue thickness can be predicted with high accuracy and moreover exploit local neighborhood information within the laser spot grid on the forehead to further increase this estimation accuracy.

Methods

We use statistical learning with Support Vector Regression and Gaussian Processes to learn a relationship between optical backscatter features and an MR tissue thickness ground truth. We compare different kernel functions for the data of five different subjects. The incident angle of the laser on the forehead as well as local neighborhoods is incorporated into the feature space. The latter represent the backscatter features from four neighboring laser spots.

Results

We confirm that the incident angle has a positive effect on the estimation error of the tissue thickness. The root-mean-square error falls even below 0.15 mm when adding the complete neighborhood information. This prior knowledge also leads to a smoothing effect on the reconstructed skin patch. Learning between different head poses yields similar results. The partial overlap of the point clouds makes the trade-off between novel information and increased feature space dimension obvious and hence feature selection by e.g., sequential forward selection necessary.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Fuss M, Salter BJ, Cheek D, Sadeghi A, Hevezi JM, Herman TS (2004) Repositioning accuracy of a commercially available thermoplastic mask system. Radiother Oncol 71:339–345CrossRefPubMed Fuss M, Salter BJ, Cheek D, Sadeghi A, Hevezi JM, Herman TS (2004) Repositioning accuracy of a commercially available thermoplastic mask system. Radiother Oncol 71:339–345CrossRefPubMed
2.
Zurück zum Zitat Minniti G, Clarke E, Cavallo L, Osti MF, Esposito V, Cantore G, Cappabianca P, Enrici RM (2011) Fractionated stereotactic conformal radiotherapy for large benign skull base meningiomas. Radiat Oncol 6:1CrossRef Minniti G, Clarke E, Cavallo L, Osti MF, Esposito V, Cantore G, Cappabianca P, Enrici RM (2011) Fractionated stereotactic conformal radiotherapy for large benign skull base meningiomas. Radiat Oncol 6:1CrossRef
3.
Zurück zum Zitat Tryggestad E, Christian M, Ford E, Kut C, Le Y, Sanguineti YG, Song DY, Kleinberg L (2011) Inter- and intrafraction patient positioning uncertainties for intracranial radiotherapy: a study of four frameless, thermoplastic mask-based immobilization strategies using daily cone-beam CT. Int J Radiat Oncol* Biol* Phys 80:281–290 Tryggestad E, Christian M, Ford E, Kut C, Le Y, Sanguineti YG, Song DY, Kleinberg L (2011) Inter- and intrafraction patient positioning uncertainties for intracranial radiotherapy: a study of four frameless, thermoplastic mask-based immobilization strategies using daily cone-beam CT. Int J Radiat Oncol* Biol* Phys 80:281–290
5.
Zurück zum Zitat Peng JL, Kahler D, Li JG, Samant S, Yan G, Amdur R, Liu C (2010) Characterization of a real-time surface image-guided stereotactic positioning system. Med Phys 37:5421–5433 Peng JL, Kahler D, Li JG, Samant S, Yan G, Amdur R, Liu C (2010) Characterization of a real-time surface image-guided stereotactic positioning system. Med Phys 37:5421–5433
6.
Zurück zum Zitat Cervino LI, Detorie N, Taylor M, Lawson JD, Harry T, Murphy KT, Mundt AJ, Jiang SB, Pawlicki TA (2012) Initial clinical experience with a frameless and maskless stereotactic radiosurgery treatment. Pract Radiat Oncol 2:54–62CrossRefPubMed Cervino LI, Detorie N, Taylor M, Lawson JD, Harry T, Murphy KT, Mundt AJ, Jiang SB, Pawlicki TA (2012) Initial clinical experience with a frameless and maskless stereotactic radiosurgery treatment. Pract Radiat Oncol 2:54–62CrossRefPubMed
7.
Zurück zum Zitat Gopan O, Wu Q (2012) Evaluation of the accuracy of a 3D surface imaging system for patient setup in head and neck cancer radiotherapy. Int J Radiat Oncol* Biol* Phys 84:547–552CrossRef Gopan O, Wu Q (2012) Evaluation of the accuracy of a 3D surface imaging system for patient setup in head and neck cancer radiotherapy. Int J Radiat Oncol* Biol* Phys 84:547–552CrossRef
8.
Zurück zum Zitat Kim Y, Li R, Na YH, Lee R, Xing L (2014) Accuracy of surface registration compared to conventional volumetric registration in patient positioning for head-and-neck radiotherapy: a simulation study using patient data. Med Phys 41:121701CrossRefPubMedPubMedCentral Kim Y, Li R, Na YH, Lee R, Xing L (2014) Accuracy of surface registration compared to conventional volumetric registration in patient positioning for head-and-neck radiotherapy: a simulation study using patient data. Med Phys 41:121701CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Ernst F, Bruder R, Wissel T, Stüber P, Wagner B, Schweikard A (2013) Real time contact-free and non-invasive tracking of the human skull first light and initial validation. In: Applications of digital image processing XXXVI, proceedings of SPIE 8856, San Diego, pp 88561G-1–88561G-8 Ernst F, Bruder R, Wissel T, Stüber P, Wagner B, Schweikard A (2013) Real time contact-free and non-invasive tracking of the human skull first light and initial validation. In: Applications of digital image processing XXXVI, proceedings of SPIE 8856, San Diego, pp 88561G-1–88561G-8
10.
Zurück zum Zitat Wissel T, Stüber P, Wagner B, Bruder R, Schweikard A, Ernst F (2013) Preliminary study on optical feature detection for head tracking in radiation therapy, 13th IEEE international conference on bioInformatics and bioengineering (BIBE). IEEE, Chania, Greece, pp 1–5 Wissel T, Stüber P, Wagner B, Bruder R, Schweikard A, Ernst F (2013) Preliminary study on optical feature detection for head tracking in radiation therapy, 13th IEEE international conference on bioInformatics and bioengineering (BIBE). IEEE, Chania, Greece, pp 1–5
11.
Zurück zum Zitat Wagner B, Stüber P, Wissel T, Bruder R, Schweikard A, Ernst F (2014) Accuracy analysis for triangulation and tracking based on time-multiplexed structured light. Med Phys 41(8):82701-1-9 Wagner B, Stüber P, Wissel T, Bruder R, Schweikard A, Ernst F (2014) Accuracy analysis for triangulation and tracking based on time-multiplexed structured light. Med Phys 41(8):82701-1-9
12.
Zurück zum Zitat Wissel T, Bruder R, Schweikard A, Ernst F (2013) Estimating soft tissue thickness from light-tissue interactions—a simulation study. Biomed Opt Express 4:1176–1187CrossRefPubMedPubMedCentral Wissel T, Bruder R, Schweikard A, Ernst F (2013) Estimating soft tissue thickness from light-tissue interactions—a simulation study. Biomed Opt Express 4:1176–1187CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Wissel T, Stueber P, Wagner B, Dürichen R, Bruder R, Schweikard A, Ernst F (2014) Tissue thickness estimation for high precision head-tracking using a galvanometric laser scanner—a case study. In: 36th annual international conference of the IEEE engineering in medicine and biology society (EMBC‘14). IEEE, Chicago, USA, pp 3106–3109 Wissel T, Stueber P, Wagner B, Dürichen R, Bruder R, Schweikard A, Ernst F (2014) Tissue thickness estimation for high precision head-tracking using a galvanometric laser scanner—a case study. In: 36th annual international conference of the IEEE engineering in medicine and biology society (EMBC‘14). IEEE, Chicago, USA, pp 3106–3109
14.
Zurück zum Zitat Wissel T, Stüber P, Wagner B, Bruder R, Schweikard A, Ernst F (2014) Angle influence and compensation for marker-less head tracking based on laser scanners. In: Proceedings of the 28th international congress and exhibition on computer assisted radiology and surgery (CARS’14), Fukuoka, Japan, vol 9, no S1, pp 62–63 Wissel T, Stüber P, Wagner B, Bruder R, Schweikard A, Ernst F (2014) Angle influence and compensation for marker-less head tracking based on laser scanners. In: Proceedings of the 28th international congress and exhibition on computer assisted radiology and surgery (CARS’14), Fukuoka, Japan, vol 9, no S1, pp 62–63
15.
Zurück zum Zitat Abdel-Aziz YI, Karara HM (1971) Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry. Proceedings of the symposium on close-range photogrammetry, Falls Church, VA Abdel-Aziz YI, Karara HM (1971) Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry. Proceedings of the symposium on close-range photogrammetry, Falls Church, VA
16.
Zurück zum Zitat Besl PJ, Keil ND (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal 14:239–256CrossRef Besl PJ, Keil ND (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal 14:239–256CrossRef
17.
Zurück zum Zitat Smola A, Schölkopf B (2004) A tutorial on Support Vector Regression. Stat Comput 14:199–222 Smola A, Schölkopf B (2004) A tutorial on Support Vector Regression. Stat Comput 14:199–222
19.
Zurück zum Zitat Verleysen M, Francois D (2005) The curse of dimensionality in data mining and time series prediction. In: Proceedings of the 8th international workshop on artificial neural networks (IWANN 2005) Barcelona, Spain, pp 758–770 Verleysen M, Francois D (2005) The curse of dimensionality in data mining and time series prediction. In: Proceedings of the 8th international workshop on artificial neural networks (IWANN 2005) Barcelona, Spain, pp 758–770
Metadaten
Titel
Enriching 3D optical surface scans with prior knowledge: tissue thickness computation by exploiting local neighborhoods
verfasst von
Tobias Wissel
Patrick Stüber
Benjamin Wagner
Ralf Bruder
Achim Schweikard
Floris Ernst
Publikationsdatum
01.04.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 4/2016
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1246-6

Weitere Artikel der Ausgabe 4/2016

International Journal of Computer Assisted Radiology and Surgery 4/2016 Zur Ausgabe

Premium Partner