Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 12/2016

01.12.2016 | Original Article

Construct validity of a video-tracking system based on orthogonal cameras approach for objective assessment of laparoscopic skills

verfasst von: Fernando Pérez-Escamirosa, Alberto Chousleb-Kalach, Maria del Carmen Hernández-Baro, Juan Alberto Sánchez-Margallo, Daniel Lorias-Espinoza, Arturo Minor-Martínez

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 12/2016

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Purpose

This study was aimed to establish the construct validity of a video-tracking system based on orthogonal cameras approach for assessment of laparoscopic psychomotor skills in training environments.

Methods

The camera-tracking system consists of two webcams placed in orthogonal configuration at a distance of 13.5 cm. The orthogonal cameras employ a color segmentation algorithm to register the 3D motions of the laparoscopic instruments using colored tapes placed on the distal end. For construct validity, 31 participants (4 experts and 27 residents) performed three training tasks in a laparoscopic box trainer with the built-in orthogonal cameras system. Eleven motion-related parameters were used to evaluate their performance. Statistical analysis was performed, and results between two groups were compared using a Mann–Whitney U-test.

Results

Construct validity results showed statistical differences in almost all motion-related parameters for assessment of laparoscopic technical skills. Results demonstrated that the orthogonal video-based tracking system was able to differentiate laparoscopic experience between experts and trainees surgeons.

Conclusion

The orthogonal cameras system was successfully validated in a laparoscopic box trainer. This video-based tracking system was able to distinguish performance between experts and trainees surgeons, showing its potential as a reliable tool to assess laparoscopic psychomotor skills. The orthogonal cameras allow incorporating the advantages of this video motion-tracking technology with the benefits of the traditional laparoscopic box trainers, creating realistic haptic feedback and allowing the evaluation of psychomotor skills of the surgeons.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat Delaney CP, Chang E, Senagore AJ, Broder M (2008) Clinical outcomes and resource utilization associated with laparoscopic and open colectomy using a large national database. Ann Surg 247:819–24CrossRefPubMed Delaney CP, Chang E, Senagore AJ, Broder M (2008) Clinical outcomes and resource utilization associated with laparoscopic and open colectomy using a large national database. Ann Surg 247:819–24CrossRefPubMed
4.
Zurück zum Zitat Aggarwal R, Moorthy K, Darzi A (2004) Laparoscopic skills training and assessment. Br J Surg 91:1549–1558CrossRefPubMed Aggarwal R, Moorthy K, Darzi A (2004) Laparoscopic skills training and assessment. Br J Surg 91:1549–1558CrossRefPubMed
5.
Zurück zum Zitat Subramonian K, DeSylva S, Bishai P, Thompson P, Muir G (2004) Acquiring surgical skills: a comparative study of open versus laparoscopic surgery. Eur Urol 45(3):346–351CrossRefPubMed Subramonian K, DeSylva S, Bishai P, Thompson P, Muir G (2004) Acquiring surgical skills: a comparative study of open versus laparoscopic surgery. Eur Urol 45(3):346–351CrossRefPubMed
6.
Zurück zum Zitat Ritter EM, Scott DJ (2007) Design of a proficiency-based skills training curriculum for the fundamentals of laparoscopic surgery. Surg Innov 14:107–112CrossRefPubMed Ritter EM, Scott DJ (2007) Design of a proficiency-based skills training curriculum for the fundamentals of laparoscopic surgery. Surg Innov 14:107–112CrossRefPubMed
7.
Zurück zum Zitat Bridges M, Diamond DL (1999) The financial impact of teaching surgical residents in the operating room. Am J Surg 177:28–32CrossRefPubMed Bridges M, Diamond DL (1999) The financial impact of teaching surgical residents in the operating room. Am J Surg 177:28–32CrossRefPubMed
8.
Zurück zum Zitat Martinez AM, Kalach AC, Espinoza DL (2008) Millimetric laparoscopic surgery training on a physical trainer using rats. Surg Endosc 22:246–9CrossRefPubMed Martinez AM, Kalach AC, Espinoza DL (2008) Millimetric laparoscopic surgery training on a physical trainer using rats. Surg Endosc 22:246–9CrossRefPubMed
9.
Zurück zum Zitat Hinata N, Iwamoto H, Morizane S, Hikita K, Yao A, Muraoka K, Honda M, Isoyama T, Sejima T, Takenaka A (2013) Dry box training with three-dimensional vision for the assistant surgeon in robot-assisted urological surgery. Int J Urol 20:1037–41. doi:10.1111/iju.12101 CrossRefPubMed Hinata N, Iwamoto H, Morizane S, Hikita K, Yao A, Muraoka K, Honda M, Isoyama T, Sejima T, Takenaka A (2013) Dry box training with three-dimensional vision for the assistant surgeon in robot-assisted urological surgery. Int J Urol 20:1037–41. doi:10.​1111/​iju.​12101 CrossRefPubMed
11.
12.
Zurück zum Zitat Loukas C, Nikiteas N, Schizas D, Lahanas V, Georgiou E (2012) A head-to-head comparison between virtual reality and physical reality simulation training for basic skills acquisition. Surg Endosc 26:2550–8. doi:10.1007/s00464-012-2230-7 CrossRefPubMed Loukas C, Nikiteas N, Schizas D, Lahanas V, Georgiou E (2012) A head-to-head comparison between virtual reality and physical reality simulation training for basic skills acquisition. Surg Endosc 26:2550–8. doi:10.​1007/​s00464-012-2230-7 CrossRefPubMed
13.
Zurück zum Zitat Sankaranarayanan G, Lin H, Arikatla VS, Mulcare M, Zhang L, Derevianko A, Lim R, Fobert D, Cao C, Schwaitzberg SD, Jones DB, De S (2010) Preliminary face and construct validation study of a virtual basic laparoscopic skill trainer. J Laparoendosc Adv Surg Tech A 20:153–7. doi:10.1089/lap.2009.0030 CrossRefPubMedPubMedCentral Sankaranarayanan G, Lin H, Arikatla VS, Mulcare M, Zhang L, Derevianko A, Lim R, Fobert D, Cao C, Schwaitzberg SD, Jones DB, De S (2010) Preliminary face and construct validation study of a virtual basic laparoscopic skill trainer. J Laparoendosc Adv Surg Tech A 20:153–7. doi:10.​1089/​lap.​2009.​0030 CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Stylopoulos N, Cotin S, Maithel SK, Ottensmeye M, Jackson PG, Bardsley RS, Neumann PF, Rattner DW, Dawson SL (2004) Computer-enhanced laparoscopic training system (CELTS): bridging the gap. Surg Endosc 18:782–789CrossRefPubMed Stylopoulos N, Cotin S, Maithel SK, Ottensmeye M, Jackson PG, Bardsley RS, Neumann PF, Rattner DW, Dawson SL (2004) Computer-enhanced laparoscopic training system (CELTS): bridging the gap. Surg Endosc 18:782–789CrossRefPubMed
17.
Zurück zum Zitat Yamaguchi S, Yoshida D, Kenmotsu H, Yasunaga T, Konishi K, Ieiri S, Nakashima H, Tanoue K, Hashizume M (2011) Objective assessment of laparoscopic suturing skills using a motion-tracking system. Surg Endosc 25:771–5. doi:10.1007/s00464-010-1251-3 CrossRefPubMed Yamaguchi S, Yoshida D, Kenmotsu H, Yasunaga T, Konishi K, Ieiri S, Nakashima H, Tanoue K, Hashizume M (2011) Objective assessment of laparoscopic suturing skills using a motion-tracking system. Surg Endosc 25:771–5. doi:10.​1007/​s00464-010-1251-3 CrossRefPubMed
18.
Zurück zum Zitat Rosen J, Brown JD, Barreca M, Chang L, Hannaford B, Sinanan M (2002) The Blue DRAGON—a system for monitoring the kinematics and the dynamics of endoscopic tools in minimally invasive surgery for objective laparoscopic skill assessment. Stud Health Technol Inform 85:412–418PubMed Rosen J, Brown JD, Barreca M, Chang L, Hannaford B, Sinanan M (2002) The Blue DRAGON—a system for monitoring the kinematics and the dynamics of endoscopic tools in minimally invasive surgery for objective laparoscopic skill assessment. Stud Health Technol Inform 85:412–418PubMed
19.
Zurück zum Zitat Egi H, Okajima M, Yoshimitsu M, Ikeda S, Miyata Y, Masugami H, Kawahara T, Kurita Y, Kaneko M, Asahara T (2008) Objective assessment of endoscopic surgical skills by analyzing direction-dependent dexterity using the Hiroshima University Endoscopic Surgical Assessment Device (HUESAD). Surg Today 38:705–10. doi:10.1007/s00595-007-3696-0 CrossRefPubMed Egi H, Okajima M, Yoshimitsu M, Ikeda S, Miyata Y, Masugami H, Kawahara T, Kurita Y, Kaneko M, Asahara T (2008) Objective assessment of endoscopic surgical skills by analyzing direction-dependent dexterity using the Hiroshima University Endoscopic Surgical Assessment Device (HUESAD). Surg Today 38:705–10. doi:10.​1007/​s00595-007-3696-0 CrossRefPubMed
20.
Zurück zum Zitat Chmarra MK, Bakker NH, Grimbergen CA, Dankelman J (2006) TrEndo, a device for tracking minimally invasive surgical instruments in training setups. Sens Actuators A Phys 126:328–334CrossRef Chmarra MK, Bakker NH, Grimbergen CA, Dankelman J (2006) TrEndo, a device for tracking minimally invasive surgical instruments in training setups. Sens Actuators A Phys 126:328–334CrossRef
21.
Zurück zum Zitat Oropesa I, Sánchez-González P, Chmarra MK, Lamata P, Fernández A, Sánchez-Margallo JA, Jansen FW, Dankelman J, Sánchez-Margallo FM, Gómez EJ (2013) EVA: laparoscopic instrument tracking based on endoscopic video analysis for psychomotor skills assessment. Surg Endosc 27:1029–39. doi:10.1007/s00464-012-2513-z CrossRefPubMed Oropesa I, Sánchez-González P, Chmarra MK, Lamata P, Fernández A, Sánchez-Margallo JA, Jansen FW, Dankelman J, Sánchez-Margallo FM, Gómez EJ (2013) EVA: laparoscopic instrument tracking based on endoscopic video analysis for psychomotor skills assessment. Surg Endosc 27:1029–39. doi:10.​1007/​s00464-012-2513-z CrossRefPubMed
22.
Zurück zum Zitat Partridge RW, Hughes MA, Brennan PM, Hennessey IA (2014) Accessible laparoscopic instrument tracking (“InsTrac”): construct validity in a take-home box simulator. J Laparoendosc Adv Surg Tech A 24:578–583. doi:10.1089/lap.2014.0015 CrossRefPubMed Partridge RW, Hughes MA, Brennan PM, Hennessey IA (2014) Accessible laparoscopic instrument tracking (“InsTrac”): construct validity in a take-home box simulator. J Laparoendosc Adv Surg Tech A 24:578–583. doi:10.​1089/​lap.​2014.​0015 CrossRefPubMed
26.
Zurück zum Zitat Pérez F, Sossa H, Martínez R, Lorias D, Minor A (2013) Video-based tracking of laparoscopic instruments using an orthogonal webcams system. World Acad Sci Eng Technol Int J Med Health Pharm Biomed Eng 7:184–187 Pérez F, Sossa H, Martínez R, Lorias D, Minor A (2013) Video-based tracking of laparoscopic instruments using an orthogonal webcams system. World Acad Sci Eng Technol Int J Med Health Pharm Biomed Eng 7:184–187
27.
Zurück zum Zitat Fraser SA, Klassen DR, Feldman LS, Ghitulescu GA, Stanbridge D, Fried GM (2003) Evaluating laparoscopic skills: setting the pass/fail score for the MISTELS system. Surg Endosc 17(6):964–967 Fraser SA, Klassen DR, Feldman LS, Ghitulescu GA, Stanbridge D, Fried GM (2003) Evaluating laparoscopic skills: setting the pass/fail score for the MISTELS system. Surg Endosc 17(6):964–967
28.
Zurück zum Zitat Chmarra MK, Kolkman W, Jansen FW, Grimbergen CA, Dankelman J (2007) The influence of experience and camera holding on laparoscopic instrument movements with the TrEndo tracking system. Surg Endosc 21:2069–2075CrossRefPubMed Chmarra MK, Kolkman W, Jansen FW, Grimbergen CA, Dankelman J (2007) The influence of experience and camera holding on laparoscopic instrument movements with the TrEndo tracking system. Surg Endosc 21:2069–2075CrossRefPubMed
29.
Zurück zum Zitat Hofstad EF, Våpenstad C, Chmarra MK, Langø T, Kuhry E, Mårvik R (2013) A study of psychomotor skills in minimally invasive surgery: what differentiates expert and nonexpert performance. Surg Endosc 27:854–863. doi:10.1007/s00464-012-2524-9 CrossRefPubMed Hofstad EF, Våpenstad C, Chmarra MK, Langø T, Kuhry E, Mårvik R (2013) A study of psychomotor skills in minimally invasive surgery: what differentiates expert and nonexpert performance. Surg Endosc 27:854–863. doi:10.​1007/​s00464-012-2524-9 CrossRefPubMed
30.
Zurück zum Zitat Escamirosa FP, Flores RM, García IO, Vidal CR, Martínez AM (2014) Face, content, and construct validity of the EndoViS training system for objective assessment of psychomotor skills of laparoscopic surgeons. Surg Endosc 29(11):3392–403. doi:10.1007/s00464-014-4032-6 CrossRefPubMed Escamirosa FP, Flores RM, García IO, Vidal CR, Martínez AM (2014) Face, content, and construct validity of the EndoViS training system for objective assessment of psychomotor skills of laparoscopic surgeons. Surg Endosc 29(11):3392–403. doi:10.​1007/​s00464-014-4032-6 CrossRefPubMed
31.
Zurück zum Zitat Oropesa I, Chmarra MK, Sánchez-González P, Lamata P, Rodrigues SP, Enciso S, Sánchez-Margallo FM, Jansen FW, Dankelman J, Gómez EJ (2013) Relevance of motion-related assessment metrics in laparoscopic surgery. Surg Innov 20:299–312. doi:10.1177/1553350612459808 CrossRefPubMed Oropesa I, Chmarra MK, Sánchez-González P, Lamata P, Rodrigues SP, Enciso S, Sánchez-Margallo FM, Jansen FW, Dankelman J, Gómez EJ (2013) Relevance of motion-related assessment metrics in laparoscopic surgery. Surg Innov 20:299–312. doi:10.​1177/​1553350612459808​ CrossRefPubMed
Metadaten
Titel
Construct validity of a video-tracking system based on orthogonal cameras approach for objective assessment of laparoscopic skills
verfasst von
Fernando Pérez-Escamirosa
Alberto Chousleb-Kalach
Maria del Carmen Hernández-Baro
Juan Alberto Sánchez-Margallo
Daniel Lorias-Espinoza
Arturo Minor-Martínez
Publikationsdatum
01.12.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 12/2016
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-016-1388-1

Weitere Artikel der Ausgabe 12/2016

International Journal of Computer Assisted Radiology and Surgery 12/2016 Zur Ausgabe