Skip to main content
Erschienen in: Microsystem Technologies 6/2008

01.06.2008 | Technical Paper

Micromachined SiO2 microcantilever for high sensitive moisture sensor

verfasst von: Qi Chen, Ji Fang, Hai-Feng Ji, Kody Varahramyan

Erschienen in: Microsystem Technologies | Ausgabe 6/2008

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Ultra-sensitive and selective moisture sensors are needed in various industries for processing control or environmental monitoring. As an outstanding sensor platform, surface-stress sensing microcantilevers have potential application in moisture detection. To enlarge the deflection of the microcantilever under surface stress induced by specific reactions, a new SiO2 microcantilever is developed which features a much lower Young’s modulus than conventional Si or SiNx microcantilevers. For comparing SiO2 cantilever with Si cantilevers, a model of the cantilever sensor is given by using both analysis and simulation, resulting in good agreement with the experimental data. The results demonstrate the SiO2 cantilever can achieve a much higher sensitivity than the Si cantilever. In order to fabricate this device, a new fabrication process using isotropic combined with anisotropic dry etching to release the SiO2 microcantilever beam by ICP (Inductively Coupled Plasma) was developed and investigated. This new process not only obtains a high etch rate at 9.1 μm/min, but also provides good profile controllability, and a flexibility of device design. Attributed to the high sensitivity, a significant deflection amplitude of the surface modified SiO2 microcantilever was observed upon exposure to 1% relative humidity. The SiO2 cantilevers are promising for inexpensive and highly sensitive moisture detection.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Aachboun S, Ranson P (1999) Deep anisotropic etching of silicon. J Vac Sci Technol A 17:2270–2273CrossRef Aachboun S, Ranson P (1999) Deep anisotropic etching of silicon. J Vac Sci Technol A 17:2270–2273CrossRef
Zurück zum Zitat Aachboun S, Ranson P, Hibert C, Boufnichel M (2000) Cryogenic etching of deep narrow trenches in silicon. J Vac Sci Technol A 18:1848–1852CrossRef Aachboun S, Ranson P, Hibert C, Boufnichel M (2000) Cryogenic etching of deep narrow trenches in silicon. J Vac Sci Technol A 18:1848–1852CrossRef
Zurück zum Zitat Arshak KI, Twomey K (2002) Investigation into a novel humidity sensor operating at room temperature. Microelectron J 33:213–220CrossRef Arshak KI, Twomey K (2002) Investigation into a novel humidity sensor operating at room temperature. Microelectron J 33:213–220CrossRef
Zurück zum Zitat Bao MH (2000) Micro mechanical transducers. In: Middelhoek S (ed) Handbook of sensors and actuators. Elsevier, Amsterdam Bao MH (2000) Micro mechanical transducers. In: Middelhoek S (ed) Handbook of sensors and actuators. Elsevier, Amsterdam
Zurück zum Zitat Barkauskas J (1997) Investigation of conductometric humidity sensors. Talanta 44:1107–1112CrossRef Barkauskas J (1997) Investigation of conductometric humidity sensors. Talanta 44:1107–1112CrossRef
Zurück zum Zitat Belaubre P, Guirardel M, Garcia G (2003) Fabrication of biological microarrays using microcantilevers. Appl Phys Lett 82:3122–3124CrossRef Belaubre P, Guirardel M, Garcia G (2003) Fabrication of biological microarrays using microcantilevers. Appl Phys Lett 82:3122–3124CrossRef
Zurück zum Zitat Boisen A, Thaysen J, Jensenius H, Hansen O (2000) Environmental sensors based on micromachined cantilevers with integrated read-out. Ultramicroscopy 82:11–16CrossRef Boisen A, Thaysen J, Jensenius H, Hansen O (2000) Environmental sensors based on micromachined cantilevers with integrated read-out. Ultramicroscopy 82:11–16CrossRef
Zurück zum Zitat Chabot MD, Moreland J (2003) Micrometer-scale magnetometry of thin Ni–Fe films using ultra-sensitive microcantilevers. J Appl Phys 93:7897–7899CrossRef Chabot MD, Moreland J (2003) Micrometer-scale magnetometry of thin Ni–Fe films using ultra-sensitive microcantilevers. J Appl Phys 93:7897–7899CrossRef
Zurück zum Zitat Chatzandroulis S, Tserepi A, Goustouridis D, Normand P, Tsoukalas D (2002) Fabrication of single crystal Si Cantilevers using a dry release process and application in a capacitive-type humidity sensor. Microelectron Eng 61–62:955–961CrossRef Chatzandroulis S, Tserepi A, Goustouridis D, Normand P, Tsoukalas D (2002) Fabrication of single crystal Si Cantilevers using a dry release process and application in a capacitive-type humidity sensor. Microelectron Eng 61–62:955–961CrossRef
Zurück zum Zitat Chou KS, Lee TK, Liu FJ (1999) Sensing mechanism of a porous ceramic as humidity sensor. Sens Actuators B 56:106–111CrossRef Chou KS, Lee TK, Liu FJ (1999) Sensing mechanism of a porous ceramic as humidity sensor. Sens Actuators B 56:106–111CrossRef
Zurück zum Zitat Freund LB, Floro JA, Chason E (1999) Extensions of the Stoney formula for substrate curvature to configurations with thin substrates or large deformations. Appl Phys Lett 74:1987–1989CrossRef Freund LB, Floro JA, Chason E (1999) Extensions of the Stoney formula for substrate curvature to configurations with thin substrates or large deformations. Appl Phys Lett 74:1987–1989CrossRef
Zurück zum Zitat Fritz J et al (2000) Translating biomolecular recognition into nanomechanics. Science 288:316–318CrossRef Fritz J et al (2000) Translating biomolecular recognition into nanomechanics. Science 288:316–318CrossRef
Zurück zum Zitat Hansen KM, Ji HF, Wu G, Datar R, Cote R, Majumadar A, Thundat T (2001) Cantilever-based optical deflection assay for discrimination of DNA single nucleotide mismatches. Anal Chem 73(7):1567–1571CrossRef Hansen KM, Ji HF, Wu G, Datar R, Cote R, Majumadar A, Thundat T (2001) Cantilever-based optical deflection assay for discrimination of DNA single nucleotide mismatches. Anal Chem 73(7):1567–1571CrossRef
Zurück zum Zitat Ji HF, Thundat TG (2002) Trace Ca2+ microcantilever sensor. Biosens Bioelectron 17:337–343CrossRef Ji HF, Thundat TG (2002) Trace Ca2+ microcantilever sensor. Biosens Bioelectron 17:337–343CrossRef
Zurück zum Zitat Ji HF, Thundat TG, Dabestani R, Brown GM, Britt PF, Bonnesen PV (2001) Ultrasensitivity detection of CrO4 2− using a microcantilever sensor. Anal Chem 73:1572–1576CrossRef Ji HF, Thundat TG, Dabestani R, Brown GM, Britt PF, Bonnesen PV (2001) Ultrasensitivity detection of CrO4 2− using a microcantilever sensor. Anal Chem 73:1572–1576CrossRef
Zurück zum Zitat Kang U, Wise K (2000) A high-speed capacitive humidity sensor with on-chip thermal reset. IEEE Trans Electron Devices 47:702–710CrossRef Kang U, Wise K (2000) A high-speed capacitive humidity sensor with on-chip thermal reset. IEEE Trans Electron Devices 47:702–710CrossRef
Zurück zum Zitat Klein CA (2000) How accurate are Stoney’s equation and recent modifications. J Appl Phys 88:5487–5489CrossRef Klein CA (2000) How accurate are Stoney’s equation and recent modifications. J Appl Phys 88:5487–5489CrossRef
Zurück zum Zitat Laermer F, Schilp A (1996) Method of anisotropically etching silicon. US Patent, 5501893 Laermer F, Schilp A (1996) Method of anisotropically etching silicon. US Patent, 5501893
Zurück zum Zitat Laermer F, Schilp A, Funk K, Offenberg M (1999) Bosch deep silicon etching: improving uniformity and etch rate for advanced MEMS applications. In: Technical Digest MEMS’99, Florida, pp 211–216 Laermer F, Schilp A, Funk K, Offenberg M (1999) Bosch deep silicon etching: improving uniformity and etch rate for advanced MEMS applications. In: Technical Digest MEMS’99, Florida, pp 211–216
Zurück zum Zitat Nahar RK, Khanna VK (1998) Ionic doping and inversion of the characteristic of thin film porous Al2O3 humidity sensor. Sens Actuators B 46:35–41CrossRef Nahar RK, Khanna VK (1998) Ionic doping and inversion of the characteristic of thin film porous Al2O3 humidity sensor. Sens Actuators B 46:35–41CrossRef
Zurück zum Zitat Oden PI, Datskos PG, Thundat T (1996) Uncooled infrared imaging using a Piezoresistive microcantilever. Appl Phys Lett 69:3277–3279CrossRef Oden PI, Datskos PG, Thundat T (1996) Uncooled infrared imaging using a Piezoresistive microcantilever. Appl Phys Lett 69:3277–3279CrossRef
Zurück zum Zitat Quevy E, Parvais B, Raskin JP, Buchaillot L, Flander D, Collard D (2002) A modified Bosch-type process for precise surface micromachining of polysilicon. J Micromech Microeng 12:328–333CrossRef Quevy E, Parvais B, Raskin JP, Buchaillot L, Flander D, Collard D (2002) A modified Bosch-type process for precise surface micromachining of polysilicon. J Micromech Microeng 12:328–333CrossRef
Zurück zum Zitat Quist F, Badia A (2003) Nanomechanical cantilever motion generated by a Surface-confined Redox Reaction. J Phys Chem B 107(39):10691–10695CrossRef Quist F, Badia A (2003) Nanomechanical cantilever motion generated by a Surface-confined Redox Reaction. J Phys Chem B 107(39):10691–10695CrossRef
Zurück zum Zitat Rittersma ZM (2002) Recent achievements in miniaturized humidity sensors—a review of transduction techniques. Sens Actuators A 96:196–210CrossRef Rittersma ZM (2002) Recent achievements in miniaturized humidity sensors—a review of transduction techniques. Sens Actuators A 96:196–210CrossRef
Zurück zum Zitat Somani PR, Viswanath AK, Aiyer RC, Radhakrishnan S (2001) Charge transfer complex-forming dyes incorporated in solid polymer electrolyte for optical humidity sensing. Sens Actuators B 80:141–148CrossRef Somani PR, Viswanath AK, Aiyer RC, Radhakrishnan S (2001) Charge transfer complex-forming dyes incorporated in solid polymer electrolyte for optical humidity sensing. Sens Actuators B 80:141–148CrossRef
Zurück zum Zitat Tang Y, Fang J, Yan X, Ji HF (2004) Fabrication and characterization of SiO2 microcantilever for microsensor application. Sens Actuators B Chem 97:109–113CrossRef Tang Y, Fang J, Yan X, Ji HF (2004) Fabrication and characterization of SiO2 microcantilever for microsensor application. Sens Actuators B Chem 97:109–113CrossRef
Zurück zum Zitat Thundat T, Oden PI, Warmack RJ (1997) Microcantilever sensors. Microscale Thermophys Eng 1:185–199CrossRef Thundat T, Oden PI, Warmack RJ (1997) Microcantilever sensors. Microscale Thermophys Eng 1:185–199CrossRef
Zurück zum Zitat Wu G, Ji HF, Hansen K, Thundat T, Datar R, Cote R, Hagan MF, Chakraborty AK, Majumdar A (2001) Nanomechanical signatures of biomolecular recognition and interactions. Proc Natl Acad Sci USA 98:1560–1564CrossRef Wu G, Ji HF, Hansen K, Thundat T, Datar R, Cote R, Hagan MF, Chakraborty AK, Majumdar A (2001) Nanomechanical signatures of biomolecular recognition and interactions. Proc Natl Acad Sci USA 98:1560–1564CrossRef
Zurück zum Zitat Xu X, Thundat TG, Brown GM, Ji HF (2002) Detection of Hg2+ using microcantilever sensors. Anal Chem 74:3611–3615CrossRef Xu X, Thundat TG, Brown GM, Ji HF (2002) Detection of Hg2+ using microcantilever sensors. Anal Chem 74:3611–3615CrossRef
Zurück zum Zitat Zhang Y, Ren Q, Zhao YP (2004) Modelling analysis of surface stress on a rectangular cantilever beam. J Phys D Appl Phys 37:2140–2145CrossRef Zhang Y, Ren Q, Zhao YP (2004) Modelling analysis of surface stress on a rectangular cantilever beam. J Phys D Appl Phys 37:2140–2145CrossRef
Metadaten
Titel
Micromachined SiO2 microcantilever for high sensitive moisture sensor
verfasst von
Qi Chen
Ji Fang
Hai-Feng Ji
Kody Varahramyan
Publikationsdatum
01.06.2008
Verlag
Springer-Verlag
Erschienen in
Microsystem Technologies / Ausgabe 6/2008
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-007-0489-8

Weitere Artikel der Ausgabe 6/2008

Microsystem Technologies 6/2008 Zur Ausgabe

Neuer Inhalt