Skip to main content

2024 | OriginalPaper | Buchkapitel

Negative Time Interval Measurement Using CMOS Standard Cell-Based Vernier TDC Channel

verfasst von : Pooja Saxena

Erschienen in: Micro and Nanoelectronics Devices, Circuits and Systems

Verlag: Springer Nature Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Vernier technique for time interval measurement between two events has gained attention due to its features of high resolution, large dynamic range and area efficiency. This paper presents negative time interval measurement between 'start' and 'stop' events using Vernier technique as its novel feature. Utilizing this feature, a CMOS standard cell-based TDC channel is designed, suitable for both positive and negative time interval measurements between ‘start’ and ‘multi-hit stop’ signal. This TDC channel measures timing of four hits comprised in multi-hit signal with respect to start with LSB of 98 ps over 14 µs dynamic range, 1 ns of double hit resolution, 0.3 LSB DNL error and 0.5 LSB INL error on typical process corner using 0.35 µm CMOS technology.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat J.P. Jansson, A stabilized multichannel CMOS time-to-digital converter based on a low frequency reference. University of Oulu graduate school; University of Oulu (2012) J.P. Jansson, A stabilized multichannel CMOS time-to-digital converter based on a low frequency reference. University of Oulu graduate school; University of Oulu (2012)
2.
Zurück zum Zitat S. Dasgupta, N.K. Mondal et al., Development of trigger scheme for the ICAL detector of India-based neutrino observatory. Nucl. Instrum. Methods Phys. Res., Sect. A 678, 105113 (2012)CrossRef S. Dasgupta, N.K. Mondal et al., Development of trigger scheme for the ICAL detector of India-based neutrino observatory. Nucl. Instrum. Methods Phys. Res., Sect. A 678, 105113 (2012)CrossRef
3.
Zurück zum Zitat O. Bourrion, L. Gallin-Martel, An integrated CMOS time-to-digital converter for coincidence detection in a liquid Xenon PET prototype. Nucl. Instrum. Meth. Phys. Res., Sect. A 563(1), 100–103 (2006)CrossRef O. Bourrion, L. Gallin-Martel, An integrated CMOS time-to-digital converter for coincidence detection in a liquid Xenon PET prototype. Nucl. Instrum. Meth. Phys. Res., Sect. A 563(1), 100–103 (2006)CrossRef
4.
Zurück zum Zitat J. Kalisz, Review of time interval measurement techniques with picoseconds resolution’, Institute of Physics (2004) J. Kalisz, Review of time interval measurement techniques with picoseconds resolution’, Institute of Physics (2004)
5.
Zurück zum Zitat K. Iniewski, Electronics for Radiation Detection, Chap. 12 (CRC Press, Taylor & Francis Group, New York, 2018) K. Iniewski, Electronics for Radiation Detection, Chap. 12 (CRC Press, Taylor & Francis Group, New York, 2018)
6.
Zurück zum Zitat R.D. Barton, King, Two vernier time-interval-digitizer. IEEE Trans. Nucl. Instrum. Methods, 359–70 (1971) R.D. Barton, King, Two vernier time-interval-digitizer. IEEE Trans. Nucl. Instrum. Methods, 359–70 (1971)
7.
Zurück zum Zitat P. Chen, C. Chen, S. Member, Y. Shen, PVT sensitive Vernier based time-to-digital converter with extended input range and high accuracy. IEEE Trans. Nucl. Sci. 54, 294–302 (2007)CrossRef P. Chen, C. Chen, S. Member, Y. Shen, PVT sensitive Vernier based time-to-digital converter with extended input range and high accuracy. IEEE Trans. Nucl. Sci. 54, 294–302 (2007)CrossRef
8.
Zurück zum Zitat K. Hari Prasad, M. Sukhwani, P. Saxena, V. B. Chandratre et al (2014) A four channel time-to-digital converter ASIC within-built Calibration and SPI Interface. Nucl. Instrum. Methods Phys. Res. A 737, 117–121 (2014) K. Hari Prasad, M. Sukhwani, P. Saxena, V. B. Chandratre et al (2014) A four channel time-to-digital converter ASIC within-built Calibration and SPI Interface. Nucl. Instrum. Methods Phys. Res. A 737, 117–121 (2014)
9.
Zurück zum Zitat K. Hari Prasad, Menka Sukhwani, Pooja Saxena, V. B. Chandratre, A CMOS standard cell based TDC, in Proceedings of International Conference on VLSI, Communication, Advanced Devices, Signals and Systems and Networking (VCASAN), vol. 258 (2013), pp. 87–93 K. Hari Prasad, Menka Sukhwani, Pooja Saxena, V. B. Chandratre, A CMOS standard cell based TDC, in Proceedings of International Conference on VLSI, Communication, Advanced Devices, Signals and Systems and Networking (VCASAN), vol. 258 (2013), pp. 87–93
10.
Zurück zum Zitat K. Hari Prasad, V.B. Chandratre, Menka Sukhwani, A versatile multi-hit, multi-channel Vernier time-to-digital converter ASIC, NIM, A-990, 164997 (2021) K. Hari Prasad, V.B. Chandratre, Menka Sukhwani, A versatile multi-hit, multi-channel Vernier time-to-digital converter ASIC, NIM, A-990, 164997 (2021)
Metadaten
Titel
Negative Time Interval Measurement Using CMOS Standard Cell-Based Vernier TDC Channel
verfasst von
Pooja Saxena
Copyright-Jahr
2024
Verlag
Springer Nature Singapore
DOI
https://doi.org/10.1007/978-981-99-4495-8_22

Neuer Inhalt