Skip to main content
Erschienen in: Health and Technology 6/2020

11.08.2020 | Original Paper

Performance evaluation of near-real time angular tube current modulation in X-ray computed tomography using real-time dosimeter: a phantom study

verfasst von: Kosuke Matsubara, Hiroki Kawashima, Masanao Kobayashi, Atsushi Fukuda

Erschienen in: Health and Technology | Ausgabe 6/2020

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In X-ray computed tomography (CT), angular tube current modulation (TCM) minimizes the unnecessary travel of X-rays in the anteroposterior direction. This study aimed to evaluate the performance of near-real time angular TCM in a CT scanner using a real-time dosimeter when different-sized elliptical phantoms were scanned. Air kerma and air kerma rate profiles of small and large elliptical phantoms were measured using a solid-state detector with a fixed tube current (FTC) and TCM with the same volume CT dose index (6.20 mGy for the small phantom and 12.32 mGy for the large phantom) displayed on the CT console. Image noises were evaluated by measuring the standard deviation of CT numbers in specific regions in the phantoms. The air kerma at the central and upper and lower peripheral holes were decreased with TCM, whereas air kerma at left and right peripheral holes were increased. With both phantom sizes, the air kerma rate profiles stabilized when TCM was used after the first two cycles. The standard deviations of CT numbers in images of the small phantom were 10.7 ± 1.3 and 10.3 ± 1.2 Hounsfield units (HU) with the FTC and TCM, respectively, and those of the large phantom were 20.6 ± 2.0 and 19.6 ± 1.7 HU, respectively. Therefore, angular TCM can adjust the tube current during each tube rotation according to the phantom’s angular attenuation profile and can decrease the image noises. It can also decrease the variance of air kerma within the in-plane direction.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Mettler FA Jr, Thomadsen BR, Bhargavan M, Gilley DB, Gray JE, Lipoti JA, et al. Medical radiation exposure in the U.S. in 2006: preliminary results. Health Phys. 2008;95:502–7.CrossRef Mettler FA Jr, Thomadsen BR, Bhargavan M, Gilley DB, Gray JE, Lipoti JA, et al. Medical radiation exposure in the U.S. in 2006: preliminary results. Health Phys. 2008;95:502–7.CrossRef
2.
Zurück zum Zitat Kalra MK, Maher MM, Toth TL, Schmidt B, Westerman BL, Morgan HT, et al. Techniques and applications of automatic tube current modulation for CT. Radiology. 2004;233:649–57.CrossRef Kalra MK, Maher MM, Toth TL, Schmidt B, Westerman BL, Morgan HT, et al. Techniques and applications of automatic tube current modulation for CT. Radiology. 2004;233:649–57.CrossRef
3.
Zurück zum Zitat Lee TY, Chhem RK. Impact of new technologies on dose reduction in CT. Eur J Radiol. 2010;76:28–35.CrossRef Lee TY, Chhem RK. Impact of new technologies on dose reduction in CT. Eur J Radiol. 2010;76:28–35.CrossRef
4.
Zurück zum Zitat Haaga JR, Miraldi F, MacIntyre W, LiPuma JP, Bryan PJ, Wiesen E. The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies. Radiology. 1981;138:449–54.CrossRef Haaga JR, Miraldi F, MacIntyre W, LiPuma JP, Bryan PJ, Wiesen E. The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies. Radiology. 1981;138:449–54.CrossRef
5.
Zurück zum Zitat Kalender WA, Wolf H, Suess C. Dose reduction in CT by anatomically adapted tube current modulation: phantom measurements. Med Phys. 1999;26:2248–53.CrossRef Kalender WA, Wolf H, Suess C. Dose reduction in CT by anatomically adapted tube current modulation: phantom measurements. Med Phys. 1999;26:2248–53.CrossRef
6.
Zurück zum Zitat McCollough CH, Bruesewitz MR, Kofler JM Jr. CT dose reduction and dose management tools: overview of available options. Radiographics. 2006;26:503–12.CrossRef McCollough CH, Bruesewitz MR, Kofler JM Jr. CT dose reduction and dose management tools: overview of available options. Radiographics. 2006;26:503–12.CrossRef
7.
Zurück zum Zitat Redžić M, Beganović A, Čiva L, Jašić R, Skopljak-Beganović A, Vegar-Zubović S. Quality control of angular tube current modulation. IFMBE Proc. 2017;62:563–7.CrossRef Redžić M, Beganović A, Čiva L, Jašić R, Skopljak-Beganović A, Vegar-Zubović S. Quality control of angular tube current modulation. IFMBE Proc. 2017;62:563–7.CrossRef
8.
Zurück zum Zitat Greess H, Wolf H, Baum U, Lell M, Pirkl M, Kalender W, et al. Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions. Eur Radiol. 2000;10:391–4.CrossRef Greess H, Wolf H, Baum U, Lell M, Pirkl M, Kalender W, et al. Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions. Eur Radiol. 2000;10:391–4.CrossRef
9.
Zurück zum Zitat Tack D, De Maertelaer V, Gevenois PA. Dose reduction in multidetector CT using attenuation-based online tube current modulation. AJR Am J Roentgenol. 2003;181:331–4.CrossRef Tack D, De Maertelaer V, Gevenois PA. Dose reduction in multidetector CT using attenuation-based online tube current modulation. AJR Am J Roentgenol. 2003;181:331–4.CrossRef
10.
Zurück zum Zitat Salehhon N, Hashim S, Karim MKA, Ang WC, Musa Y, Bahruddin NA. 128 slice computed tomography dose profile measurement using thermoluminescent dosimeter. J Phys Conf Ser. 2017;851:012002.CrossRef Salehhon N, Hashim S, Karim MKA, Ang WC, Musa Y, Bahruddin NA. 128 slice computed tomography dose profile measurement using thermoluminescent dosimeter. J Phys Conf Ser. 2017;851:012002.CrossRef
11.
Zurück zum Zitat Söderberg M, Gunnarsson M. The effect of different adaptation strengths on image quality and radiation dose using Siemens care dose 4D. Radiat Prot Dosim. 2010;139:173–9.CrossRef Söderberg M, Gunnarsson M. The effect of different adaptation strengths on image quality and radiation dose using Siemens care dose 4D. Radiat Prot Dosim. 2010;139:173–9.CrossRef
12.
Zurück zum Zitat Herrnsdorf L, Björk M, Cederquist B, Mattsson CG, Thungström G, Fröjdh C. Point dose profile measurements using solid-state detectors in characterization of computed tomography systems. Nucl Instrum Methods Phys Res Sect A. 2009;607:223–5.CrossRef Herrnsdorf L, Björk M, Cederquist B, Mattsson CG, Thungström G, Fröjdh C. Point dose profile measurements using solid-state detectors in characterization of computed tomography systems. Nucl Instrum Methods Phys Res Sect A. 2009;607:223–5.CrossRef
13.
Zurück zum Zitat Muramatsu Y, Ikeda S, Osawa K, Sekine R, Niwa N, Terada M, et al. Performance evaluation for CT-AEC (CT automatic exposure control) systems. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2007;63:534–45.CrossRef Muramatsu Y, Ikeda S, Osawa K, Sekine R, Niwa N, Terada M, et al. Performance evaluation for CT-AEC (CT automatic exposure control) systems. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2007;63:534–45.CrossRef
14.
Zurück zum Zitat Brisse HJ, Madec L, Gaboriaud G, Lemoine T, Savignoni A, Neuenschwander S, et al. Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: experimental assessment on pediatric phantoms. Med Phys. 2007;34:3018–33.CrossRef Brisse HJ, Madec L, Gaboriaud G, Lemoine T, Savignoni A, Neuenschwander S, et al. Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: experimental assessment on pediatric phantoms. Med Phys. 2007;34:3018–33.CrossRef
15.
Zurück zum Zitat Söderberg M, Gunnarsson M. Automatic exposure control in compured tomography – an evaluation of systems from different manufacturers. Acta Radiol. 2010;51:625–34.CrossRef Söderberg M, Gunnarsson M. Automatic exposure control in compured tomography – an evaluation of systems from different manufacturers. Acta Radiol. 2010;51:625–34.CrossRef
16.
Zurück zum Zitat Raman SP, Mahesh M, Blasko RV, Fishman EK. CT scan parameters and radiation dose: practical advice for radiologists. J Am Coll Radiol. 2013;10:840–6.CrossRef Raman SP, Mahesh M, Blasko RV, Fishman EK. CT scan parameters and radiation dose: practical advice for radiologists. J Am Coll Radiol. 2013;10:840–6.CrossRef
Metadaten
Titel
Performance evaluation of near-real time angular tube current modulation in X-ray computed tomography using real-time dosimeter: a phantom study
verfasst von
Kosuke Matsubara
Hiroki Kawashima
Masanao Kobayashi
Atsushi Fukuda
Publikationsdatum
11.08.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
Health and Technology / Ausgabe 6/2020
Print ISSN: 2190-7188
Elektronische ISSN: 2190-7196
DOI
https://doi.org/10.1007/s12553-020-00473-y

Weitere Artikel der Ausgabe 6/2020

Health and Technology 6/2020 Zur Ausgabe

Premium Partner