Peristaltic micropump system with piezoelectric actuators

verfasst von: Ling-Sheng Jang, Yung-Chiang Yu

Erschienen in: Microsystem Technologies | Ausgabe 2/2008

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This work presents a driving system for a peristaltic micropump that is based on piezoelectric actuation. The effects of the actuation sequence on pump performance are also considered. A valveless peristaltic micropump based on piezoelectric actuation is designed and fabricated using microelectromechanical system technology. The pump has three parts––silicon, Pyrex glass and commercially available bulk PZT (lead zirconate titanate) chips. The peristaltic micropump actuated by PZT chips comprises three chambers that are in series. The driving system consists of an ATmega 8535 microprocessor, a high voltage power supply, three differential amplifiers, a phase controller, an A/D converter, a 555 oscillator and an LCD module. It is supplied via a 110 Vrms 60-Hz AC line and is programmable. The system can produce step-function signals with voltages of up to 100 Vpp and frequencies ranging from 10 Hz to 1 kHz, as the inputs for the pump. Fluid pumping with air is successfully demonstrated. Additionally, 3-, 4- and 6-phase actuation sequences for the pump are designed and used to study the effects on pump performance, as revealed by the flow rate and the displacement of a pump diaphragm. The experimental results show that the flow rate and the displacement of the diaphragm actuated by the 4-phase sequence exceed those actuated by the 3- and 6-phase sequences. A flow rate of 17.6 μl min−1 and a displacement of 2.91 μm (peak-to-peak) in 4-phase peristaltic motion are achieved at 100 Hz and 100 Vpp. The results demonstrate that the pump actuated in the 4-phase sequence is the most efficient. Consequently, the actuation sequences can affect the pump performance.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Ahn CH, Allen MG (1995) Fluid micropumps based on rotary magnetic actuators. In: Proceedings of the IEEE micro electro mechanical systems (MEMS), pp 408–412 Ahn CH, Allen MG (1995) Fluid micropumps based on rotary magnetic actuators. In: Proceedings of the IEEE micro electro mechanical systems (MEMS), pp 408–412
Zurück zum Zitat Anderssona H, van der Wijngaarta W, Nilssonb P, Enokssona P, Stemme G (2001) A valve-less diffuser micropump for microfluidic analytical systems. Sens Actuators B 72:259–265CrossRef Anderssona H, van der Wijngaarta W, Nilssonb P, Enokssona P, Stemme G (2001) A valve-less diffuser micropump for microfluidic analytical systems. Sens Actuators B 72:259–265CrossRef
Zurück zum Zitat Cao L, Mantell S, Polla D (2001) Design and simulation of an implantable medical drug delivery system using microelectromechanical systems technology. Sens Actuators A 94:117–125CrossRef Cao L, Mantell S, Polla D (2001) Design and simulation of an implantable medical drug delivery system using microelectromechanical systems technology. Sens Actuators A 94:117–125CrossRef
Zurück zum Zitat Carr JJ, Brown JM (2001) Introduction to biomedical equipment technology, 4th edn. Prentice Hall, Upper Saddle River Carr JJ, Brown JM (2001) Introduction to biomedical equipment technology, 4th edn. Prentice Hall, Upper Saddle River
Zurück zum Zitat Francais O, Dufour I (1998) Dynamic simulation of an electrostatic micropump with pull-in and hysteresis phenomena. Sens Actuators A 70:56–60CrossRef Francais O, Dufour I (1998) Dynamic simulation of an electrostatic micropump with pull-in and hysteresis phenomena. Sens Actuators A 70:56–60CrossRef
Zurück zum Zitat Gopalan KG (1996) Introduction to digital microelectronic circuits. IRWIN Chicago Gopalan KG (1996) Introduction to digital microelectronic circuits. IRWIN Chicago
Zurück zum Zitat Greiherr G (1997) Micromachines making headway in medical applications. Med Dev Diagn Indus 19(8):50–57 Greiherr G (1997) Micromachines making headway in medical applications. Med Dev Diagn Indus 19(8):50–57
Zurück zum Zitat Husband B, Bu M, Evans AG. R, Melvin T (2004) Investigation for the operation of an integrated peristaltic micropump. J Micromech Microeng 14:S64–S69CrossRef Husband B, Bu M, Evans AG. R, Melvin T (2004) Investigation for the operation of an integrated peristaltic micropump. J Micromech Microeng 14:S64–S69CrossRef
Zurück zum Zitat Jan G.S (1990) Piezoelectric micropump with three valves working peristaltically. Sens Actuators A 21–23:203–206 Jan G.S (1990) Piezoelectric micropump with three valves working peristaltically. Sens Actuators A 21–23:203–206
Zurück zum Zitat Jang LS, Li YJ, Lin SJ, Hsu YC, Yao WS, Tsai MC, Hou CC (2007) A stand-alone peristaltic micropump based on piezoelectric actuation. Biomed Microdev 9(2):185–194CrossRef Jang LS, Li YJ, Lin SJ, Hsu YC, Yao WS, Tsai MC, Hou CC (2007) A stand-alone peristaltic micropump based on piezoelectric actuation. Biomed Microdev 9(2):185–194CrossRef
Zurück zum Zitat Lee DS, Ko JS, Kim YT (2004) Bidirectional pumping properties of a peristaltic piezoelectric micropump with simple design and chemical resistance. Thin Solid Films 486:285–290CrossRef Lee DS, Ko JS, Kim YT (2004) Bidirectional pumping properties of a peristaltic piezoelectric micropump with simple design and chemical resistance. Thin Solid Films 486:285–290CrossRef
Zurück zum Zitat Liao CS, Lee G.B, Wu JJ, Chang CC, Hsieh TM, Huang FC, Luo CH (2005) Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases. Biosens Bioelectron 20:1341–1348CrossRef Liao CS, Lee G.B, Wu JJ, Chang CC, Hsieh TM, Huang FC, Luo CH (2005) Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases. Biosens Bioelectron 20:1341–1348CrossRef
Zurück zum Zitat Nguyen NT, Huang X, Chuan TK (2002) MEMS-Micropumps: a review. Transact ASME 124:384–391 Nguyen NT, Huang X, Chuan TK (2002) MEMS-Micropumps: a review. Transact ASME 124:384–391
Zurück zum Zitat Sedra A, Smith KC (1992) Microelectronics circuits, 4th edn. HRW Sedra A, Smith KC (1992) Microelectronics circuits, 4th edn. HRW
Zurück zum Zitat Shu YC (2002) Shape-memory micropumps. Mat Transact 43(5):1037–1044CrossRef Shu YC (2002) Shape-memory micropumps. Mat Transact 43(5):1037–1044CrossRef
Zurück zum Zitat Tay FEH (2002) Microfluidics and BioMEMS applications. Kluwer, Boston Tay FEH (2002) Microfluidics and BioMEMS applications. Kluwer, Boston
Zurück zum Zitat Tsai JH, Lin L (2002) Active microfludic mixer and gas bubble filter driven thermal bubble micropump. Sens Actuator A 97–98:665–671CrossRef Tsai JH, Lin L (2002) Active microfludic mixer and gas bubble filter driven thermal bubble micropump. Sens Actuator A 97–98:665–671CrossRef
Zurück zum Zitat Xie J, Shih J, Lin Q, Yang B, Tai YC (2004) Surface micromachined electrostatically actuated micro peristaltic pump. Lab Chip 4:495–501CrossRef Xie J, Shih J, Lin Q, Yang B, Tai YC (2004) Surface micromachined electrostatically actuated micro peristaltic pump. Lab Chip 4:495–501CrossRef
Metadaten
Titel
Peristaltic micropump system with piezoelectric actuators
verfasst von
Ling-Sheng Jang
Yung-Chiang Yu
Publikationsdatum
01.02.2008
Verlag
Springer-Verlag
Erschienen in
Microsystem Technologies / Ausgabe 2/2008
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-007-0428-8

Weitere Artikel der Ausgabe 2/2008

Microsystem Technologies 2/2008 Zur Ausgabe

Neuer Inhalt