Skip to main content
Erschienen in: Experimental Mechanics 3/2007

01.06.2007

Plated and Intact Femur Strains in Fracture Fixation Using Fiber Bragg Gratings and Strain Gauges

verfasst von: P. M. Talaia, A. Ramos, I. Abe, M. W. Schiller, P. Lopes, R. N. Nogueira, J. L. Pinto, R. Claramunt, J. A. Simões

Erschienen in: Experimental Mechanics | Ausgabe 3/2007

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This paper presents an experimental methodology to determine plated and intact femur strains using fiber Bragg gratings and strain gauges. A plated and an intact synthetic femur were used and loaded under a simplistic static load of 600 N. A stainless steel (316L) plate was used to fixate a simulated 45° fracture on one femur. Strains were recoded at the same sites on both femurs. Strain shielding is shown to be more pronounced at the distal region of the plated femur. The experimental methodology based on fiber Bragg grating sensors is a novel approach to assess bone plate strains, which could also be used to obtain biologic tissue and implant surface strains in locations where conventional strain gauge use is not technically feasible.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Lacroix D, Prendergast PJ, Li G, Marsh D (2003) A biomechanical model to simulate tissue differentiation and bone regeneration: application to fracture healing. Medical Biology Engineering Computation 40:14–21.CrossRef Lacroix D, Prendergast PJ, Li G, Marsh D (2003) A biomechanical model to simulate tissue differentiation and bone regeneration: application to fracture healing. Medical Biology Engineering Computation 40:14–21.CrossRef
3.
Zurück zum Zitat Doblaré M, Gárcia JM, Cegoñino J (2002) Development of an internal bone remodelling theory and applications to some problems in orthopaedic biomechanics. Meccanica 37:365–374.MATHCrossRef Doblaré M, Gárcia JM, Cegoñino J (2002) Development of an internal bone remodelling theory and applications to some problems in orthopaedic biomechanics. Meccanica 37:365–374.MATHCrossRef
4.
Zurück zum Zitat Prendergast P J (2001) Bone prostheses and implants. In: Cowin SC (ed) Bone mechanics handbook, Ch. 35. CRC, Boca Raton. Prendergast P J (2001) Bone prostheses and implants. In: Cowin SC (ed) Bone mechanics handbook, Ch. 35. CRC, Boca Raton.
5.
Zurück zum Zitat Huiskes R, van Driel WD, Prendergast PJ, Soballe K (1997) Biomechanical regulatory model for periprosthetic fibrous tissue differentiation. Journal Material Science: Materials in Medicine 8:785–788.CrossRef Huiskes R, van Driel WD, Prendergast PJ, Soballe K (1997) Biomechanical regulatory model for periprosthetic fibrous tissue differentiation. Journal Material Science: Materials in Medicine 8:785–788.CrossRef
6.
Zurück zum Zitat Stiffler K S (2004) Internal fracture fixation. Clinical Techniques Small Animals Practice 19:105–113.CrossRef Stiffler K S (2004) Internal fracture fixation. Clinical Techniques Small Animals Practice 19:105–113.CrossRef
7.
Zurück zum Zitat Ganesh VJ, Dhanjoo KR, Ghista N (2005) Biomechanics of bone-fracture fixation by stiffness-graded plates incomparison with stainless-steel plates. BioMedical Engineering OnLine 4:46.CrossRef Ganesh VJ, Dhanjoo KR, Ghista N (2005) Biomechanics of bone-fracture fixation by stiffness-graded plates incomparison with stainless-steel plates. BioMedical Engineering OnLine 4:46.CrossRef
8.
Zurück zum Zitat Rand JA, An KN, Chao EY, Kelly PJ (1981) A comparison of the effect of open intramedullary nailing and compression-plate fixation on fracture-site blood flow and fracture union. J Bone Jt Surg A 63(3):427–442. Rand JA, An KN, Chao EY, Kelly PJ (1981) A comparison of the effect of open intramedullary nailing and compression-plate fixation on fracture-site blood flow and fracture union. J Bone Jt Surg A 63(3):427–442.
9.
Zurück zum Zitat Tencer AF, Johnson KD (1994) Biomechanics in orthopeadic trauma. Bone fracture and fixation 1st edition. Martin Dunitz. Tencer AF, Johnson KD (1994) Biomechanics in orthopeadic trauma. Bone fracture and fixation 1st edition. Martin Dunitz.
10.
Zurück zum Zitat Tayton K, Bradley J (1993) How stiff should semi-rigid fixation of the human tibia be? A clue to the answer. Journal of Bone and Joint Surgery A 65(3):312–315. Tayton K, Bradley J (1993) How stiff should semi-rigid fixation of the human tibia be? A clue to the answer. Journal of Bone and Joint Surgery A 65(3):312–315.
11.
Zurück zum Zitat Dennis RC, Vasu R (1981) Stress fields in the unplated and plated canine femur calculated from in vivo strain measurements. J Biomech 1(14):63–70. Dennis RC, Vasu R (1981) Stress fields in the unplated and plated canine femur calculated from in vivo strain measurements. J Biomech 1(14):63–70.
12.
Zurück zum Zitat Fujihara K, Haung Z, Ramakrishna S, Satknanantham K, Hamada H (2003) Performance study of Braided carbon/PEEK composite compression bone plates. J Biomater 24:2661–2667.CrossRef Fujihara K, Haung Z, Ramakrishna S, Satknanantham K, Hamada H (2003) Performance study of Braided carbon/PEEK composite compression bone plates. J Biomater 24:2661–2667.CrossRef
13.
Zurück zum Zitat Ali MS, French TA, Hastings GW, Rae T, Rushton N, Ross E. RS (1990) Carbon fiber composite bone plates. J Bone Jt Surg B 72:586–591. Ali MS, French TA, Hastings GW, Rae T, Rushton N, Ross E. RS (1990) Carbon fiber composite bone plates. J Bone Jt Surg B 72:586–591.
14.
Zurück zum Zitat Tonino L, Davidson CL, Klopper PL, Linclau LA (1976) Protection from stress in bone and its effects. J Bone Jt Surg B 58(1):107–113. Tonino L, Davidson CL, Klopper PL, Linclau LA (1976) Protection from stress in bone and its effects. J Bone Jt Surg B 58(1):107–113.
15.
Zurück zum Zitat Amnon F, Alan JY, Hans KU (1997) Improved fracture healing with less rigid plates. Clin Orthop Relat Res 39(3):232–245. Amnon F, Alan JY, Hans KU (1997) Improved fracture healing with less rigid plates. Clin Orthop Relat Res 39(3):232–245.
16.
Zurück zum Zitat Cordey J, Perren SM, Steinemannz SG (2000) Stress protection due to plates: Myth or reality? A parametric analysis made using the composite beam theory. Injury, International Journal Care Injured 31:l–13. Cordey J, Perren SM, Steinemannz SG (2000) Stress protection due to plates: Myth or reality? A parametric analysis made using the composite beam theory. Injury, International Journal Care Injured 31:l–13.
17.
Zurück zum Zitat Viceconti M, Cristofolini l, Baleani M, Toni A (2001) Pre-clinical validation of a new partiallycemented femoral prosthesis by synergetic use of numerical and experimental methods. J Biomech 34:723–731.CrossRef Viceconti M, Cristofolini l, Baleani M, Toni A (2001) Pre-clinical validation of a new partiallycemented femoral prosthesis by synergetic use of numerical and experimental methods. J Biomech 34:723–731.CrossRef
18.
Zurück zum Zitat Carvalho L, Silva JCC, Nogueira R, Pinto JL, Kalinowski H, Simões JA (2006) Application of Bragg grating sensors in dental biomechanics. J Strain Anal 41(6):411–415.CrossRef Carvalho L, Silva JCC, Nogueira R, Pinto JL, Kalinowski H, Simões JA (2006) Application of Bragg grating sensors in dental biomechanics. J Strain Anal 41(6):411–415.CrossRef
19.
Zurück zum Zitat Breque C, Dupre J, Bremand F (2004) Calibration of a system of projection moire for relief measuring: biomechanical applications. Opt Lasers Eng 41:241–260.CrossRef Breque C, Dupre J, Bremand F (2004) Calibration of a system of projection moire for relief measuring: biomechanical applications. Opt Lasers Eng 41:241–260.CrossRef
20.
Zurück zum Zitat Huo B (2005) An inhomogeneous and anisotropic constitutive model of human dentin. J Biomech 38:587–594.CrossRef Huo B (2005) An inhomogeneous and anisotropic constitutive model of human dentin. J Biomech 38:587–594.CrossRef
21.
Zurück zum Zitat Kishena A, Tana KBC, Asundib A (2006) Digital moire´ interferometric investigations on the deformation gradients of enamel and dentine: An insight into non-carious cervical lesions. J Dent 34:12–18.CrossRef Kishena A, Tana KBC, Asundib A (2006) Digital moire´ interferometric investigations on the deformation gradients of enamel and dentine: An insight into non-carious cervical lesions. J Dent 34:12–18.CrossRef
22.
Zurück zum Zitat Edvardsen T, Helle-Valle T, Smiseth OA (2006) Systolic dysfunction in heart failure with normal ejection fraction: speckle-tracking echocardiograp. Prog Cardiovasc Dis 49(3):207–214.CrossRef Edvardsen T, Helle-Valle T, Smiseth OA (2006) Systolic dysfunction in heart failure with normal ejection fraction: speckle-tracking echocardiograp. Prog Cardiovasc Dis 49(3):207–214.CrossRef
23.
Zurück zum Zitat Horta J, Brostow W, Martinez G, Castano VM (2003) Characterization of bones by speckle interferometry. J Med Eng Technol 27(2):49–53.CrossRef Horta J, Brostow W, Martinez G, Castano VM (2003) Characterization of bones by speckle interferometry. J Med Eng Technol 27(2):49–53.CrossRef
24.
Zurück zum Zitat Zhang J, Jin GC, Meng LB, Jian LH, Wang AY, Lu SB (2005) Strain and mechanical behavior measurements of soft tissues with digital speckle method. J Biomed Opt 10(3):000–000. Zhang J, Jin GC, Meng LB, Jian LH, Wang AY, Lu SB (2005) Strain and mechanical behavior measurements of soft tissues with digital speckle method. J Biomed Opt 10(3):000–000.
25.
Zurück zum Zitat Kessler O, Lacatusu E, Sommers MB, Mayr E, Bottlang M (2006) Malrotation in total knee arthroplasty: effect on tibial cortex strain captured by laser-based strain acquisition. Clin Biomech 21(6):603–609.CrossRef Kessler O, Lacatusu E, Sommers MB, Mayr E, Bottlang M (2006) Malrotation in total knee arthroplasty: effect on tibial cortex strain captured by laser-based strain acquisition. Clin Biomech 21(6):603–609.CrossRef
26.
Zurück zum Zitat Shahar R, Zaslansky P, Barak M, Friesem AA III, Currey, JD, Weiner S (2006) Speckle interferometry: a novel method to map three-dimensional surface deformations of small bone samples. J Biomech 39(Suppl 1):S18.CrossRef Shahar R, Zaslansky P, Barak M, Friesem AA III, Currey, JD, Weiner S (2006) Speckle interferometry: a novel method to map three-dimensional surface deformations of small bone samples. J Biomech 39(Suppl 1):S18.CrossRef
27.
Zurück zum Zitat Mohr M, Simon U, Claes L, Bottlang M (2006) Full-field strain acquisition on ovine fracture callus with electronic speckle pattern interferometry. J Biomech 39(Suppl 1):S467.CrossRef Mohr M, Simon U, Claes L, Bottlang M (2006) Full-field strain acquisition on ovine fracture callus with electronic speckle pattern interferometry. J Biomech 39(Suppl 1):S467.CrossRef
28.
Zurück zum Zitat Simões JA, Monteiro J, Vaz MA (2001) Numerical-experimental method for the validation of a controlled stiffness femoral prosthesis. J Biomech Eng Trans ASME 123:234–238.CrossRef Simões JA, Monteiro J, Vaz MA (2001) Numerical-experimental method for the validation of a controlled stiffness femoral prosthesis. J Biomech Eng Trans ASME 123:234–238.CrossRef
29.
Zurück zum Zitat Simões JA, Monteiro J, Vaz MA (2001) Femoral displacement patterns induced by different prosthesis fixation methods: A holographic study. J Biomech 34(Suppl 1):S27. Simões JA, Monteiro J, Vaz MA (2001) Femoral displacement patterns induced by different prosthesis fixation methods: A holographic study. J Biomech 34(Suppl 1):S27.
30.
Zurück zum Zitat Vieira A, Frazão O, Novo C, Simões JA (2004) On the use of fiber grating sensors for strain measurements in biomechanics, European Society of Biomechanics, ESB 2004, 4–7 July, Hertogenbosch, The Netherlands. Vieira A, Frazão O, Novo C, Simões JA (2004) On the use of fiber grating sensors for strain measurements in biomechanics, European Society of Biomechanics, ESB 2004, 4–7 July, Hertogenbosch, The Netherlands.
31.
Zurück zum Zitat Simões JA, Vaz MA (2002) The Influence on strain shielding of material stiffness of press-fit femoral components. Proceedings Institution Mechanical Engineers, Part H, Journal Engineering Medicine 216:341–346CrossRef Simões JA, Vaz MA (2002) The Influence on strain shielding of material stiffness of press-fit femoral components. Proceedings Institution Mechanical Engineers, Part H, Journal Engineering Medicine 216:341–346CrossRef
32.
Zurück zum Zitat Carvalho L, Vaz MA, Simões JA (2004) Mandible strains induced by conventional and novel dental implants. J Strain Anal Eng Des 39(3):291–297.CrossRef Carvalho L, Vaz MA, Simões JA (2004) Mandible strains induced by conventional and novel dental implants. J Strain Anal Eng Des 39(3):291–297.CrossRef
33.
Zurück zum Zitat - Silva, JC, Carvalho L, Nogueira RN, Simões JA, Pinto JL, Kalinowski HJ (2004) FBG applied in dynamic analysis of an implanted cadaveric mandible”, Second European Workshop on Optical Fiber Sensors, Santander; Saratov Fall Meeting 2003: Laser Physics and Photonics, Spectroscopy, and Molecular Modeling IV. In: Derbov Vladimir L, Melnikov Leonid A, Babkov Lev M (eds) Proceedings of the SPIE, 5502, 226–229. - Silva, JC, Carvalho L, Nogueira RN, Simões JA, Pinto JL, Kalinowski HJ (2004) FBG applied in dynamic analysis of an implanted cadaveric mandible”, Second European Workshop on Optical Fiber Sensors, Santander; Saratov Fall Meeting 2003: Laser Physics and Photonics, Spectroscopy, and Molecular Modeling IV. In: Derbov Vladimir L, Melnikov Leonid A, Babkov Lev M (eds) Proceedings of the SPIE, 5502, 226–229.
34.
Zurück zum Zitat Milczeswki MS, Silva JCC, Simões JA, Paterno AS, Kalinowski H (2006) Measurement of orthodontic forces and tooth displacement using fiber Bragg grating sensors. 5th International Conference on Mechanics Materials and Design, Porto. Milczeswki MS, Silva JCC, Simões JA, Paterno AS, Kalinowski H (2006) Measurement of orthodontic forces and tooth displacement using fiber Bragg grating sensors. 5th International Conference on Mechanics Materials and Design, Porto.
35.
Zurück zum Zitat Ottevaere H, Tabak M, Aznar D, Fernandez A, Van Ierschot S, Berghmans F Thienpont H (2003) Optical fiber sensors for monitoring stress build-up in dental cements 16th International Conference on Optical Fiber Sensor (Nara) 574–577. Ottevaere H, Tabak M, Aznar D, Fernandez A, Van Ierschot S, Berghmans F Thienpont H (2003) Optical fiber sensors for monitoring stress build-up in dental cements 16th International Conference on Optical Fiber Sensor (Nara) 574–577.
36.
Zurück zum Zitat Liu HB, Liu HY, Peng GD, Chu PL (2003) Strain and temperature sensor using a combination of polymer and silica fiber bragg gratings. Opt Commun 219(1–6):139–142.CrossRef Liu HB, Liu HY, Peng GD, Chu PL (2003) Strain and temperature sensor using a combination of polymer and silica fiber bragg gratings. Opt Commun 219(1–6):139–142.CrossRef
37.
Zurück zum Zitat Wehrle G, Nohama P, Kalinowski HJ, Torres PI Valente, LCG (2001) A fiber optic bragg grating strain sensor for monitoring ventilatory movements. Meas Sci Technol 12:805–809.CrossRef Wehrle G, Nohama P, Kalinowski HJ, Torres PI Valente, LCG (2001) A fiber optic bragg grating strain sensor for monitoring ventilatory movements. Meas Sci Technol 12:805–809.CrossRef
38.
Zurück zum Zitat Kashyap R (1999) Fiber bragg grating. Academic Press, San Diego. Kashyap R (1999) Fiber bragg grating. Academic Press, San Diego.
39.
Zurück zum Zitat Higuera JML (2002) Handbook of optical fiber sensing technology. Wiley, New York. Higuera JML (2002) Handbook of optical fiber sensing technology. Wiley, New York.
40.
Zurück zum Zitat Othonos A (1997) Fiber bragg gratings. Review Science Instrumentation 68(12):4309–4341.CrossRef Othonos A (1997) Fiber bragg gratings. Review Science Instrumentation 68(12):4309–4341.CrossRef
41.
Zurück zum Zitat Heiner AD, Brown TD (2001) Structural properties of new design of composite replicate femurs and tibias. J Biomech 34:773–781.CrossRef Heiner AD, Brown TD (2001) Structural properties of new design of composite replicate femurs and tibias. J Biomech 34:773–781.CrossRef
42.
Zurück zum Zitat Cristofolini L, Bini S, Toni A, (1998) In vitro testing of a novel limb salvage prosthesis for the distal femur. Clin Biomech 13:608–615.CrossRef Cristofolini L, Bini S, Toni A, (1998) In vitro testing of a novel limb salvage prosthesis for the distal femur. Clin Biomech 13:608–615.CrossRef
43.
Zurück zum Zitat Cristofolini L, Viceconti M (1997) Comparison of uniaxial and triaxial strain gages for strain measurement in the femur. Exp Mech 37(3):350–354.CrossRef Cristofolini L, Viceconti M (1997) Comparison of uniaxial and triaxial strain gages for strain measurement in the femur. Exp Mech 37(3):350–354.CrossRef
44.
Zurück zum Zitat Dias Rodrigues, JF, Lopes H, Simões JA (2004) Experimental model analysis of a synthetic composite femur. Exp Mech 44(1):29–32.CrossRef Dias Rodrigues, JF, Lopes H, Simões JA (2004) Experimental model analysis of a synthetic composite femur. Exp Mech 44(1):29–32.CrossRef
45.
Zurück zum Zitat Grecula MJ, Morris RP, Laughlin JC, Buford WL, Patterson RM (2000) Femoral surface strain in intact composite femurs: a custom computer analysis of the photoelastic coating technique. IEEE Trans Biomed Eng 47:926–933.CrossRef Grecula MJ, Morris RP, Laughlin JC, Buford WL, Patterson RM (2000) Femoral surface strain in intact composite femurs: a custom computer analysis of the photoelastic coating technique. IEEE Trans Biomed Eng 47:926–933.CrossRef
46.
Zurück zum Zitat Stolk J, Verdonschot N, Cristofolini L, Firmati L, Toni A, Huiskes R (2000) Strains in a composite hip joint reconstruction obtained through FEA and experiments correspond closely. Transactions of the 46th Annual Meeting of the Orthopaedic Research Society, O515. Stolk J, Verdonschot N, Cristofolini L, Firmati L, Toni A, Huiskes R (2000) Strains in a composite hip joint reconstruction obtained through FEA and experiments correspond closely. Transactions of the 46th Annual Meeting of the Orthopaedic Research Society, O515.
47.
Zurück zum Zitat Szivek JA, Gealer RL (1991) Comparison of the deformation response of synthetic and cadaveric femora during simulated onelegged stance. J Appl Biomater 2(4):277–280.CrossRef Szivek JA, Gealer RL (1991) Comparison of the deformation response of synthetic and cadaveric femora during simulated onelegged stance. J Appl Biomater 2(4):277–280.CrossRef
48.
Zurück zum Zitat McNamara BP, Cristofolini L, Toni A, Taylor D (1994) Evaluation of experimental and finite element models of synthetic and cadaveric femora for pre-clinical design-analysis. Clin Mater 17(3):131–140.CrossRef McNamara BP, Cristofolini L, Toni A, Taylor D (1994) Evaluation of experimental and finite element models of synthetic and cadaveric femora for pre-clinical design-analysis. Clin Mater 17(3):131–140.CrossRef
49.
Zurück zum Zitat Cristofolini L, Viceconti M, Cappelo A, Toni A (1996) Mechanical validation of whole bone composite femur models. J Biomech 29(4):525–535.CrossRef Cristofolini L, Viceconti M, Cappelo A, Toni A (1996) Mechanical validation of whole bone composite femur models. J Biomech 29(4):525–535.CrossRef
50.
Zurück zum Zitat Cristofolini L (1997) A critical analysis of stress shielding evaluation of hip prostheses. Crit Rev Biomed Eng 25:409–483. Cristofolini L (1997) A critical analysis of stress shielding evaluation of hip prostheses. Crit Rev Biomed Eng 25:409–483.
51.
Zurück zum Zitat Ruff CB, Hayes WC (1983) Cross-section geometry of pecos pueblo femora and tibiae – a biomechanical investigation: 1. Methods and general patterns of variation. American Journal of Physics Anthropology 60:359–381.CrossRef Ruff CB, Hayes WC (1983) Cross-section geometry of pecos pueblo femora and tibiae – a biomechanical investigation: 1. Methods and general patterns of variation. American Journal of Physics Anthropology 60:359–381.CrossRef
52.
Zurück zum Zitat Finlay JB, Bourne RB, McLeant J (1982) A technique for in vitro measurement of principal strains in the human femur. J Biomech 5(10):723–739.CrossRef Finlay JB, Bourne RB, McLeant J (1982) A technique for in vitro measurement of principal strains in the human femur. J Biomech 5(10):723–739.CrossRef
53.
Zurück zum Zitat Nogueira R, Abe I, Kalinowski HJ, Pinto JL, Rocha JRF (2002) Sistema interferométrico automatizado para gravação de redes de Bragg. 13a Conferência Nacional de Física, Évora, 592–594. Nogueira R, Abe I, Kalinowski HJ, Pinto JL, Rocha JRF (2002) Sistema interferométrico automatizado para gravação de redes de Bragg. 13a Conferência Nacional de Física, Évora, 592–594.
54.
Zurück zum Zitat Duda GN, Heller M, Albinger J, Schulz O, Schneider E, Claes L (1998) Influence of muscle forces on Femoral strain distribution. J Biomech 31(9):841–846.CrossRef Duda GN, Heller M, Albinger J, Schulz O, Schneider E, Claes L (1998) Influence of muscle forces on Femoral strain distribution. J Biomech 31(9):841–846.CrossRef
Metadaten
Titel
Plated and Intact Femur Strains in Fracture Fixation Using Fiber Bragg Gratings and Strain Gauges
verfasst von
P. M. Talaia
A. Ramos
I. Abe
M. W. Schiller
P. Lopes
R. N. Nogueira
J. L. Pinto
R. Claramunt
J. A. Simões
Publikationsdatum
01.06.2007
Erschienen in
Experimental Mechanics / Ausgabe 3/2007
Print ISSN: 0014-4851
Elektronische ISSN: 1741-2765
DOI
https://doi.org/10.1007/s11340-007-9034-z

Weitere Artikel der Ausgabe 3/2007

Experimental Mechanics 3/2007 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.