Skip to main content

2013 | OriginalPaper | Buchkapitel

8. Remaining Life Analysis

verfasst von : Sivaji Chakravorti, Debangshu Dey, Biswendu Chatterjee

Erschienen in: Recent Trends in the Condition Monitoring of Transformers

Verlag: Springer London

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Generally, the life of a transformer is equated to the life of its cellulose insulation. In other words, the aging of cellulose insulation determines the ultimate life of a transformer. It has been established that thermal degradation of cellulose insulation like paper and pressboard eventually limit transformer lifetimes. In order to develop a model for predicting life expectancy of oil-immersed transformers, it is necessary to understand the aging mechanism of cellulose insulation. Life estimation using transformer thermal model is a practical approach in predicting transformer end-of-life as detailed in IEEE and IEC guides. In such cases, calculation of life of in-service transformers is done based on temperature rise of transformers, its loading condition, and ambient temperature. But the results of such thermal models using temperature rise as the only index of aging introduce large errors in life estimation. Temperature rise, oil condition, loading history, and design parameters are all key factors that determine the loss of life of a transformer through thermochemical degradation. Degree of polymerization (DP) of cellulose insulation is an excellent indicator of insulation aging which incorporates the effect of all the key factors of aging. Hence, transformer life estimation using the DP value of its solid insulation has been explored over the years. But DP tests are destructive in nature and are very difficult to perform for transformer in service. So life estimation through non-destructive testing by measurement of furanic compounds in oil, which are present in oil in dissolved state, is an attractive alternative. Since this methodology is based on oil tests, it could be used for online monitoring of transformer life, too. A predictive model which involves reliability engineering, physical understanding of the degradation process, and actual knowledge of the present condition of a transformer is necessary for accurate estimation of remaining life, which will facilitate appropriate replacement time of transformer and planning of appropriate maintenance scenario.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Jarman P, Wang Z, Zhong Q, Ishak T (2009) End-of-Life modeling for power transformers in aged power system networks. CIGRE 6th Southern Africa Regional Conference, Paper C105 Jarman P, Wang Z, Zhong Q, Ishak T (2009) End-of-Life modeling for power transformers in aged power system networks. CIGRE 6th Southern Africa Regional Conference, Paper C105
2.
Zurück zum Zitat van Schijndel A, Wetzer JM, Wouters PAAF (2008) Remaining lifetime modelling for replacement of power transformer populations. In: Proceedings of international conference on condition monitoring and diagnosis, Beijing, China, April 21–24 van Schijndel A, Wetzer JM, Wouters PAAF (2008) Remaining lifetime modelling for replacement of power transformer populations. In: Proceedings of international conference on condition monitoring and diagnosis, Beijing, China, April 21–24
3.
Zurück zum Zitat Montsinger VM (1930) Loading the transformers by temperature. AIEE Trans 49:776–792 Montsinger VM (1930) Loading the transformers by temperature. AIEE Trans 49:776–792
4.
Zurück zum Zitat Dakin TW (1947) Electrical insulation deterioration treated as a chemical reaction rate phenomenon. AIEE Trans 66:113–122 Dakin TW (1947) Electrical insulation deterioration treated as a chemical reaction rate phenomenon. AIEE Trans 66:113–122
5.
Zurück zum Zitat IEEE Loading Guide for Mineral Oil Immersed Transformer, C57.91-1995 IEEE Loading Guide for Mineral Oil Immersed Transformer, C57.91-1995
6.
Zurück zum Zitat IEC 60076 Part 7: Loading Guide for Oil-immersed Power Transformers, 2005 IEC 60076 Part 7: Loading Guide for Oil-immersed Power Transformers, 2005
7.
Zurück zum Zitat CIGRE Working Group 12.09 (1993) Lifetime evaluation of transformers. Electra, pp 39–51 CIGRE Working Group 12.09 (1993) Lifetime evaluation of transformers. Electra, pp 39–51
8.
Zurück zum Zitat IEEE Standard Test Procedure for Thermal Evaluation Liquid-Immersed Distribution and Power Transformers, C57.100-1999 IEEE Standard Test Procedure for Thermal Evaluation Liquid-Immersed Distribution and Power Transformers, C57.100-1999
9.
Zurück zum Zitat CIGRE Working Group 12.09 (1995) Experimental determination of power transformer hot-spot factor. Electra, pp 35–39 CIGRE Working Group 12.09 (1995) Experimental determination of power transformer hot-spot factor. Electra, pp 35–39
10.
Zurück zum Zitat Fallou B (1970) Synthesis of work carried out at LCIE on paper degradation. Rev Gen Elect 79:645 Fallou B (1970) Synthesis of work carried out at LCIE on paper degradation. Rev Gen Elect 79:645
11.
Zurück zum Zitat Bouvier B (1970) Criteria for characterizing the degradation of paper based insulation. Rev Gen Elec 79:489–496 Bouvier B (1970) Criteria for characterizing the degradation of paper based insulation. Rev Gen Elec 79:489–496
12.
Zurück zum Zitat Skabula W, Roganwicz J (1975) Effect of using inhibitor 2,6-di-tert-butyl-p-cresol on ageing of electrical insulation paper. Prz Papier 31:357–360 Skabula W, Roganwicz J (1975) Effect of using inhibitor 2,6-di-tert-butyl-p-cresol on ageing of electrical insulation paper. Prz Papier 31:357–360
13.
Zurück zum Zitat Emsley AM, Stevens GC (1992) A reassessment of the low temperature thermal degradation of cellulose. In: Proceedings of sixth international conference on dielectric materials, measurements and applications, Manchester, pp 229–232 Emsley AM, Stevens GC (1992) A reassessment of the low temperature thermal degradation of cellulose. In: Proceedings of sixth international conference on dielectric materials, measurements and applications, Manchester, pp 229–232
14.
Zurück zum Zitat Emsley AM, Stevens GC (1994) Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformers. IEE Proc-Sci Meas Technol 141(5):324–334 Emsley AM, Stevens GC (1994) Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformers. IEE Proc-Sci Meas Technol 141(5):324–334
15.
Zurück zum Zitat Fabre J, Pichon A (1960) Deteriorating processes and products of paper in oil—Application to transformers. In: Proceedings of international conference on large high voltage electric system, CIGRE, Paris, P 137 Fabre J, Pichon A (1960) Deteriorating processes and products of paper in oil—Application to transformers. In: Proceedings of international conference on large high voltage electric system, CIGRE, Paris, P 137
16.
Zurück zum Zitat Shroff DH, Stannett AW (1985) A review of paper aging in power transformers. IEE Proc Part C 132:312–319 Shroff DH, Stannett AW (1985) A review of paper aging in power transformers. IEE Proc Part C 132:312–319
17.
Zurück zum Zitat Bandyopadhyay MN (2007) Transformer diagnostics in the practical field. In: International conference on sustainable development: challenges and opportunities for GMS, Pattaya, Thailand, 12–14 Dec Bandyopadhyay MN (2007) Transformer diagnostics in the practical field. In: International conference on sustainable development: challenges and opportunities for GMS, Pattaya, Thailand, 12–14 Dec
18.
Zurück zum Zitat de Pablo A (1999) Furfural and ageing: how are they related. In: IEE Colloquium on Insulating Liquids, pp 5/1–5/4 de Pablo A (1999) Furfural and ageing: how are they related. In: IEE Colloquium on Insulating Liquids, pp 5/1–5/4
19.
Zurück zum Zitat Yan Z, Dong M, Shang Y, Muhr M (2004) Ageing diagnosis and life estimation of paper insulation for operating power transformer. In: Proceedings of international conference on solid dielectrics, Toulouse, France, July 5–9 Yan Z, Dong M, Shang Y, Muhr M (2004) Ageing diagnosis and life estimation of paper insulation for operating power transformer. In: Proceedings of international conference on solid dielectrics, Toulouse, France, July 5–9
20.
Zurück zum Zitat Pradhan MK, Ramu TS (2005) On the estimation of elapsed life of oil-immersed power transformers. IEEE Trans on Power Delivery 20(3):1962–1969CrossRef Pradhan MK, Ramu TS (2005) On the estimation of elapsed life of oil-immersed power transformers. IEEE Trans on Power Delivery 20(3):1962–1969CrossRef
21.
Zurück zum Zitat Allan D, Jones C, Sharp B (1991) Studies of the condition of insulation in aged power transformers. Part-1: insulation condition and remnant life assessments for in-service units. In: Proceedings of the 3rd international conference on properties and applications of dielectric materials, Tokyo, Japan, July 8–12 Allan D, Jones C, Sharp B (1991) Studies of the condition of insulation in aged power transformers. Part-1: insulation condition and remnant life assessments for in-service units. In: Proceedings of the 3rd international conference on properties and applications of dielectric materials, Tokyo, Japan, July 8–12
22.
Zurück zum Zitat Abu-Siada A, Pin LS, Islam S (2009) Remnant life estimation of power transformer using oil UV-Vis spectral response. In: IEEE-PES power systems conference and exposition, Seattle, pp 1–5 Abu-Siada A, Pin LS, Islam S (2009) Remnant life estimation of power transformer using oil UV-Vis spectral response. In: IEEE-PES power systems conference and exposition, Seattle, pp 1–5
Metadaten
Titel
Remaining Life Analysis
verfasst von
Sivaji Chakravorti
Debangshu Dey
Biswendu Chatterjee
Copyright-Jahr
2013
Verlag
Springer London
DOI