Skip to main content
Erschienen in: Clean Technologies and Environmental Policy 4/2012

01.08.2012 | Original Paper

Saving energy using fuzzy control applied to a chiller: an experimental study

verfasst von: F. V. Silva, J. E. Schmitz, L. C. Neves Filho, A. M. F. Fileti, V. Silveira Júnior

Erschienen in: Clean Technologies and Environmental Policy | Ausgabe 4/2012

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In this study the energy consumption of a chiller system, under different configurations and control strategies, was investigated. Two control strategies (Proportional integral—PI and fuzzy-PI) were applied to regulate the temperature of propylene glycol solution and the evaporating temperature using compressor motor supply frequency and pump rotation frequency as manipulated variables. The experiments were initiated with the system in open loop. When the steady-state condition was reached the system was submitted to a positive disturbance in its heat load and the feedback control was activated. Hence, the results were analyzed by means of integral of the time-weighted absolute error (ITAE) criterion and total energy consumption. The analysis of experimental results showed that both controllers were able to regulate the controlled variables appropriately. Also, it was verified that the use of the compressor motor supply frequency as manipulated variable can smooth out process variable oscillations. Besides, comparing the energy demands of both controllers, it was observed that the fuzzy-PI controller required 3.4% less electric energy (0.81 kWh). Considering the propylene glycol solution temperature (secondary fluid) as controlled variable and compressor motor supply frequency as manipulated variable, fuzzy-PI control achieves smaller ITAE index value, and energy consumption than the PI counterpart, consuming 0.25 kWh less energy. Thus, energy savings could be attained for control configurations that exhibit higher ITAE values. It was demonstrated that is desirable to include the energy consumption as a control performance parameter in order to increase the energetic efficiency of process.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Aprea C, Mastrullo R, Renno C (2004) Fuzzy control of the compressor speed in a refrigerant plat. Int J Refrig 27:639–648CrossRef Aprea C, Mastrullo R, Renno C (2004) Fuzzy control of the compressor speed in a refrigerant plat. Int J Refrig 27:639–648CrossRef
Zurück zum Zitat Åström KJ, Hägglund T (1984) Automatic tuning of simple regulators with specifications on phase and amplitude margins. Automatica 20(5):645–651CrossRef Åström KJ, Hägglund T (1984) Automatic tuning of simple regulators with specifications on phase and amplitude margins. Automatica 20(5):645–651CrossRef
Zurück zum Zitat Chiou CB, Chiou CH, Chu CM, Lin SL (2009) The application of fuzzy control on energy saving for multi-unit room air-conditioners. Ap Ther Eng 29(2–3):310–316CrossRef Chiou CB, Chiou CH, Chu CM, Lin SL (2009) The application of fuzzy control on energy saving for multi-unit room air-conditioners. Ap Ther Eng 29(2–3):310–316CrossRef
Zurück zum Zitat Ekren O, Küçüka S (2010) Energy saving potential of chiller system with fuzzy logic control. Int J Energy Res 34:897–906CrossRef Ekren O, Küçüka S (2010) Energy saving potential of chiller system with fuzzy logic control. Int J Energy Res 34:897–906CrossRef
Zurück zum Zitat Ferrer J, Rodrigo MA, Seco A, Penya-Roja JM (1998) Energy saving in the aeration process by fuzzy logic control. Wat Sci Tech 38(3):209–217CrossRef Ferrer J, Rodrigo MA, Seco A, Penya-Roja JM (1998) Energy saving in the aeration process by fuzzy logic control. Wat Sci Tech 38(3):209–217CrossRef
Zurück zum Zitat Li HX, Gatland HB (1996) Conventional fuzzy control and its enhancement. IEEE Trans Systs Man Cybern 26(5):884–889 Li HX, Gatland HB (1996) Conventional fuzzy control and its enhancement. IEEE Trans Systs Man Cybern 26(5):884–889
Zurück zum Zitat Mamlook R, Badran O, Aljumah A, Almazyad AS, Eldos T, Abdulhadi E (2011) Fuzzy logic controller to improve parameters affecting gas turbines power generation. Clean Techn Environ Policy. doi:10.1007/s1009801103571 Mamlook R, Badran O, Aljumah A, Almazyad AS, Eldos T, Abdulhadi E (2011) Fuzzy logic controller to improve parameters affecting gas turbines power generation. Clean Techn Environ Policy. doi:10.​1007/​s1009801103571
Zurück zum Zitat Pedrycz W, Gomide F (1998) An introduction to fuzzy sets. MIT Press, Massachussets Pedrycz W, Gomide F (1998) An introduction to fuzzy sets. MIT Press, Massachussets
Zurück zum Zitat Reddy VS, Panwar NL, Kaushik SC (2011) Exergetic analysis of a vapour compression refrigeration system with R134a, R143a, R152a, R404A, R407C, R410A, R502 and R507A. Clean Techn Environ Policy. doi:10.1007/s1009801103740 Reddy VS, Panwar NL, Kaushik SC (2011) Exergetic analysis of a vapour compression refrigeration system with R134a, R143a, R152a, R404A, R407C, R410A, R502 and R507A. Clean Techn Environ Policy. doi:10.​1007/​s1009801103740
Zurück zum Zitat Seborg DE, Edgar TF, Mellichamp DA (2004) Process dynamics and control. Wiley, New Jersey Seborg DE, Edgar TF, Mellichamp DA (2004) Process dynamics and control. Wiley, New Jersey
Zurück zum Zitat Silva FV, Neves Filho LC, Silveira Junior V (2006) Experimental evaluation of fuzzy controllers for the temperature control of the secondary refrigerant in a liquid chiller. J Food Eng 75:349–354CrossRef Silva FV, Neves Filho LC, Silveira Junior V (2006) Experimental evaluation of fuzzy controllers for the temperature control of the secondary refrigerant in a liquid chiller. J Food Eng 75:349–354CrossRef
Metadaten
Titel
Saving energy using fuzzy control applied to a chiller: an experimental study
verfasst von
F. V. Silva
J. E. Schmitz
L. C. Neves Filho
A. M. F. Fileti
V. Silveira Júnior
Publikationsdatum
01.08.2012
Verlag
Springer-Verlag
Erschienen in
Clean Technologies and Environmental Policy / Ausgabe 4/2012
Print ISSN: 1618-954X
Elektronische ISSN: 1618-9558
DOI
https://doi.org/10.1007/s10098-011-0409-6

Weitere Artikel der Ausgabe 4/2012

Clean Technologies and Environmental Policy 4/2012 Zur Ausgabe