Skip to main content

2013 | OriginalPaper | Buchkapitel

Smart Textiles: Technology and Wireless System Network Applications

verfasst von : Antonio Lanatà, Enzo Pasquale Scilingo

Erschienen in: Autonomous Sensor Networks

Verlag: Springer Berlin Heidelberg

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In the last two decades, many research groups and industrial companies have been and are putting much efforts in developing and using fabrics in which electronics, digital components as well as computing can be embedded. These fabrics are identified as E-textiles (e.g., electronic textiles or smart textiles). Starting from the established concept, which asserts that future systems need to be more suitably interfaced with the humans with minimal discomfort and maximum acceptability, the possibility enabled by the E-textile platforms of developing wearable and intelligent technology in terms of everyday textiles and clothes, has made them one of the most important and interesting front-end between the biological and the technological world. One field of application of these innovative textiles is the ambient intelligence, where the use of wireless system network (WSN), body area network (BAN), or wireless body/personal area network (WB/PAN) has made it possible to integrate information coming from the environment, context awareness, and the habits of people during their activities, opening new areas of research on mental and emotional status as well as human behavior in different cultural environments. This chapter is focused on the research literature of the textile-based systems and aims at showing how and where they are currently used. Starting from the textile apparel, i.e. the technology used today for their construction, the chapter reports on the characterization, integration of electronic components and, finally, briefly it illustrates some E-textile-based WBAN platforms applications on network architecture for health care and lifestyle.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Lukowicz P, Kirstein T, Troster G (2004) Wearable systems for health care applications. Methods Inform Med 43(3):232–238 Lukowicz P, Kirstein T, Troster G (2004) Wearable systems for health care applications. Methods Inform Med 43(3):232–238
2.
Zurück zum Zitat Cao H, Leung V, Chow C, Chan H (2009) Enabling technologies for wireless body area networks: a survey and outlook. Commun Mag IEEE 47(12):84–93CrossRef Cao H, Leung V, Chow C, Chan H (2009) Enabling technologies for wireless body area networks: a survey and outlook. Commun Mag IEEE 47(12):84–93CrossRef
3.
Zurück zum Zitat Lymberis A, Paradiso R (2008) Smart fabrics and interactive textile enabling wearable personal applications: R&D state of the art and future challenges. In: Engineering in Medicine and Biology Society, 2008 (EMBS 2008). 30th annual international conference of the IEEE, IEEE, pp 5270–5273 Lymberis A, Paradiso R (2008) Smart fabrics and interactive textile enabling wearable personal applications: R&D state of the art and future challenges. In: Engineering in Medicine and Biology Society, 2008 (EMBS 2008). 30th annual international conference of the IEEE, IEEE, pp 5270–5273
4.
Zurück zum Zitat Lymberis A, Gatzoulis L (2006) Wearable health systems: from smart technologies to real applications. In: EMBS annual international conference. Proceedings of the 28th IEEE, New York Lymberis A, Gatzoulis L (2006) Wearable health systems: from smart technologies to real applications. In: EMBS annual international conference. Proceedings of the 28th IEEE, New York
5.
Zurück zum Zitat Post E, Orth M (1997) Smart fabric, or wearable clothing. In: First international symposium on wearable computers. Digest of papers, IEEE, pp 167–168 Post E, Orth M (1997) Smart fabric, or wearable clothing. In: First international symposium on wearable computers. Digest of papers, IEEE, pp 167–168
6.
Zurück zum Zitat Lind E, Jayaraman S, Park S, Rajamanickam R, Eisler R, Burghart G, McKee T (1997) A sensate liner for personnel monitoring applications. In: ISWC, IEEE Computer Society, p 98 Lind E, Jayaraman S, Park S, Rajamanickam R, Eisler R, Burghart G, McKee T (1997) A sensate liner for personnel monitoring applications. In: ISWC, IEEE Computer Society, p 98
7.
Zurück zum Zitat Ishijima M (1997) Cardiopulmonary monitoring by textile electrodes without subject-awareness of being monitored. Med Biol Eng Comput 35(6):685–690CrossRef Ishijima M (1997) Cardiopulmonary monitoring by textile electrodes without subject-awareness of being monitored. Med Biol Eng Comput 35(6):685–690CrossRef
8.
Zurück zum Zitat De Rossi D, Santa A, Mazzoldi A (1997) Dressware: wearable piezo and thermoresistive fabrics for ergonomics and rehabilitation. In: Engineering in Medicine and Biology Society, 1997. Proceedings of the 19th annual international conference of the IEEE, vol 5, IEEE, Chicago, 1997, pp 1880–1883 De Rossi D, Santa A, Mazzoldi A (1997) Dressware: wearable piezo and thermoresistive fabrics for ergonomics and rehabilitation. In: Engineering in Medicine and Biology Society, 1997. Proceedings of the 19th annual international conference of the IEEE, vol 5, IEEE, Chicago, 1997, pp 1880–1883
9.
Zurück zum Zitat Marculescu D, Marculescu R, Khosla P (2002) Challenges and opportunities in electronic textiles modeling and optimization. In: Proceedings of the 39th annual design automation conference, ACM, New Orleans, pp 175–180 Marculescu D, Marculescu R, Khosla P (2002) Challenges and opportunities in electronic textiles modeling and optimization. In: Proceedings of the 39th annual design automation conference, ACM, New Orleans, pp 175–180
10.
Zurück zum Zitat Cottet D, Grzyb J, Kirstein T, Troster G (2003) Electrical characterization of textile transmission lines. Adv Packag IEEE Trans 26(2):182–190CrossRef Cottet D, Grzyb J, Kirstein T, Troster G (2003) Electrical characterization of textile transmission lines. Adv Packag IEEE Trans 26(2):182–190CrossRef
11.
Zurück zum Zitat Karayianni E (2007) Electrically conductive elastic composite yarn, methods for making the same, and articles incorporating the same. EP Patent 1,631,711 (27 June 2007) Karayianni E (2007) Electrically conductive elastic composite yarn, methods for making the same, and articles incorporating the same. EP Patent 1,631,711 (27 June 2007)
12.
Zurück zum Zitat Gimpel S, Mohring U, Muller H, Neudeck A, Scheibner W (2004) Textile-based electronic substrate technology. J Ind Text 33(3):179CrossRef Gimpel S, Mohring U, Muller H, Neudeck A, Scheibner W (2004) Textile-based electronic substrate technology. J Ind Text 33(3):179CrossRef
13.
Zurück zum Zitat Benson M, Neudecker B, Emerson B (2003) Power fibers: thin-film batteries on fiber substrates Benson M, Neudecker B, Emerson B (2003) Power fibers: thin-film batteries on fiber substrates
14.
Zurück zum Zitat Axisa F, Schmitt P, Gehin C, Delhomme G, McAdams E, Dittmar A (2005) Flexible technologies and smart clothing for citizen medicine, home healthcare, and disease prevention. Inform Technol Biomed IEEE Trans 9(3):325–336CrossRef Axisa F, Schmitt P, Gehin C, Delhomme G, McAdams E, Dittmar A (2005) Flexible technologies and smart clothing for citizen medicine, home healthcare, and disease prevention. Inform Technol Biomed IEEE Trans 9(3):325–336CrossRef
15.
Zurück zum Zitat Hill I, Trotz S, Riddle G, Brookstein D, Govindaraj M (2006) Plural layer woven electronic textile, article and method. US Patent 7,144,830 (5 December 2006) Hill I, Trotz S, Riddle G, Brookstein D, Govindaraj M (2006) Plural layer woven electronic textile, article and method. US Patent 7,144,830 (5 December 2006)
16.
Zurück zum Zitat Post E, Orth M, Russo P, Gershenfeld N (2000) E-broidery: design and fabrication of textile-based computing. IBM Syst J 39(3/4):840–860CrossRef Post E, Orth M, Russo P, Gershenfeld N (2000) E-broidery: design and fabrication of textile-based computing. IBM Syst J 39(3/4):840–860CrossRef
17.
Zurück zum Zitat Chou T (1992) Microstructural design of fiber composites. Cambridge University Press, Cambridge Chou T (1992) Microstructural design of fiber composites. Cambridge University Press, Cambridge
18.
Zurück zum Zitat Chou T, Kamiya R, Cheeseman B (1998) An assessment of the textile preform technology for structural composites. Recent advances in mechanics of aerospace structures and materials, pp 165–171 Chou T, Kamiya R, Cheeseman B (1998) An assessment of the textile preform technology for structural composites. Recent advances in mechanics of aerospace structures and materials, pp 165–171
19.
Zurück zum Zitat Curiskis J, Durie A, Nicolaidis A, Herszberg I (1997) Developments in multiaxial weaving for advanced composite materials. In: Proceedings of the ICCM-11 (six volumes), p 86 Curiskis J, Durie A, Nicolaidis A, Herszberg I (1997) Developments in multiaxial weaving for advanced composite materials. In: Proceedings of the ICCM-11 (six volumes), p 86
20.
Zurück zum Zitat Hearle J (1994) Textiles for composites. Text Horizons 14(6):12–15 Hearle J (1994) Textiles for composites. Text Horizons 14(6):12–15
21.
Zurück zum Zitat Evans R (1998) Method, machine and diagonal pattern fabric for threedimensional flat panel fabric. US Patent 5,791,384 (11 August 1998) Evans R (1998) Method, machine and diagonal pattern fabric for threedimensional flat panel fabric. US Patent 5,791,384 (11 August 1998)
22.
Zurück zum Zitat Dirk Philips I, Van RaemdonckJ J (1997) Optimising the mechanical properties of 3d-knitted sandwich structures. In: Proceedings of the ICCM-11 (six volumes), p 211 Dirk Philips I, Van RaemdonckJ J (1997) Optimising the mechanical properties of 3d-knitted sandwich structures. In: Proceedings of the ICCM-11 (six volumes), p 211
23.
Zurück zum Zitat Yasui Y, Anahara M, Hori F, Takeuchi J (1994) Method of producing fabric reinforcing matrix for composites. US Patent 5,327,621 (12 July 1994) Yasui Y, Anahara M, Hori F, Takeuchi J (1994) Method of producing fabric reinforcing matrix for composites. US Patent 5,327,621 (12 July 1994)
24.
Zurück zum Zitat Popper P, McConnell R (1987) A new 3d braid for integrated parts manufacture and improved delamination resistance- the 2-step process. In: Advanced materials technology’87, Anaheim, pp 92–103 Popper P, McConnell R (1987) A new 3d braid for integrated parts manufacture and improved delamination resistance- the 2-step process. In: Advanced materials technology’87, Anaheim, pp 92–103
25.
Zurück zum Zitat Li W, Shiekh A (1988) Effect of processes and processing parameters on 3-d braided preforms for composites. SAMPE Q (United States) 19(4):22–28 Li W, Shiekh A (1988) Effect of processes and processing parameters on 3-d braided preforms for composites. SAMPE Q (United States) 19(4):22–28
26.
Zurück zum Zitat Kostar T, Chou T (1994) Process simulation and fabrication of advanced multi-step three-dimensional braided preforms. J Mater Sci 29(8):2159–2167CrossRef Kostar T, Chou T (1994) Process simulation and fabrication of advanced multi-step three-dimensional braided preforms. J Mater Sci 29(8):2159–2167CrossRef
27.
Zurück zum Zitat Kostar T (1998) Analysis, design, fabrication, and performance of threedimensional braided composites. Diss Abstr Int 59(4B):1811–2051 Kostar T (1998) Analysis, design, fabrication, and performance of threedimensional braided composites. Diss Abstr Int 59(4B):1811–2051
28.
Zurück zum Zitat Ostmann A, Loher T, Seckel M, Bottcher L, Reichl H (2008) Manufacturing concepts for stretchable electronic systems. In: Microsystems, Packaging, Assembly & Circuits Technology Conference, 2008 (IMPACT 2008), 3rd international, IEEE, Taipei, Taiwan, pp 24–27 Ostmann A, Loher T, Seckel M, Bottcher L, Reichl H (2008) Manufacturing concepts for stretchable electronic systems. In: Microsystems, Packaging, Assembly & Circuits Technology Conference, 2008 (IMPACT 2008), 3rd international, IEEE, Taipei, Taiwan, pp 24–27
29.
Zurück zum Zitat Kallmayer C, Pisarek R, Neudeck A, Cichos S, Gimpel S, Aschenbrenner R, Reichlt H (2003) New assembly technologies for textile transponder systems. In: Proceedings of the 53rd electronic components and technology conference, IEEE, pp 1123–1126 Kallmayer C, Pisarek R, Neudeck A, Cichos S, Gimpel S, Aschenbrenner R, Reichlt H (2003) New assembly technologies for textile transponder systems. In: Proceedings of the 53rd electronic components and technology conference, IEEE, pp 1123–1126
30.
Zurück zum Zitat Bossuyt F, Güenther J, Löher T, Seckel M, Sterken T, De Vries J (2011) Cyclic endurance reliability of stretchable electronic substrates. Micro Electron Reliab 51(3):628–635CrossRef Bossuyt F, Güenther J, Löher T, Seckel M, Sterken T, De Vries J (2011) Cyclic endurance reliability of stretchable electronic substrates. Micro Electron Reliab 51(3):628–635CrossRef
31.
Zurück zum Zitat Lozano A (1997) Electrode errors in bioimpedance measurement systems for long-term applications. In: Proceedings of the 1997 sixteenth southern biomedical engineering conference, IEEE, Biloxi, Mississippi, USA, pp 3–6 Lozano A (1997) Electrode errors in bioimpedance measurement systems for long-term applications. In: Proceedings of the 1997 sixteenth southern biomedical engineering conference, IEEE, Biloxi, Mississippi, USA, pp 3–6
32.
Zurück zum Zitat Scilingo E, Gemignani A, Paradiso R, Taccini N, Ghelarducci B, De Rossi D (2005) Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables. Inform Technol Biomed IEEE Trans 9(3):345–352CrossRef Scilingo E, Gemignani A, Paradiso R, Taccini N, Ghelarducci B, De Rossi D (2005) Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables. Inform Technol Biomed IEEE Trans 9(3):345–352CrossRef
33.
Zurück zum Zitat Mestrovic M, Helmer R, Kyratzis L, Kumar D (2007) Preliminary study of dry knitted fabric electrodes for physiological monitoring. In: Third international conference on intelligent sensors, sensor networks and information, 2007 (ISSNIP 2007), IEEE, Melbourne, pp 601–606 Mestrovic M, Helmer R, Kyratzis L, Kumar D (2007) Preliminary study of dry knitted fabric electrodes for physiological monitoring. In: Third international conference on intelligent sensors, sensor networks and information, 2007 (ISSNIP 2007), IEEE, Melbourne, pp 601–606
34.
Zurück zum Zitat Searle A, Kirkup L (2000) A direct comparison of wet, dry and insulating bioelectric recording electrodes. Physiol Meas 21:271CrossRef Searle A, Kirkup L (2000) A direct comparison of wet, dry and insulating bioelectric recording electrodes. Physiol Meas 21:271CrossRef
35.
Zurück zum Zitat Rattfaelt L, Linden M, Hult P, Berglin L, Ask P (2007) Electrical characteristics of conductive yarns and textile electrodes for medical applications. Med Biol Eng Comput 45(12):1251–1257CrossRef Rattfaelt L, Linden M, Hult P, Berglin L, Ask P (2007) Electrical characteristics of conductive yarns and textile electrodes for medical applications. Med Biol Eng Comput 45(12):1251–1257CrossRef
36.
Zurück zum Zitat Riistama J, Lekkala J (2006) Electrode-electrolyte interface properties in implantation conditions. In: 28th annual international conference of the Engineering in Medicine and Biology Society, 2006 (EMBS’06), IEEE, New York, USA, pp 6021–6024 Riistama J, Lekkala J (2006) Electrode-electrolyte interface properties in implantation conditions. In: 28th annual international conference of the Engineering in Medicine and Biology Society, 2006 (EMBS’06), IEEE, New York, USA, pp 6021–6024
37.
Zurück zum Zitat Sunaga T, Ikehira H, Furukawa S, Shinkai H, Kobayashi H, Matsumoto Y, Yoshitome E, Obata T, Tanada S, Murata H et al (2002) Measurement of the electrical properties of human skin and the variation among subjects with certain skin conditions. Phys Med Biol 47:N11CrossRef Sunaga T, Ikehira H, Furukawa S, Shinkai H, Kobayashi H, Matsumoto Y, Yoshitome E, Obata T, Tanada S, Murata H et al (2002) Measurement of the electrical properties of human skin and the variation among subjects with certain skin conditions. Phys Med Biol 47:N11CrossRef
38.
Zurück zum Zitat Lanatà A, Valenza G, Scilingo E (2010) Electrodermal responses through textile electrodes. Res J Text Apparel 14(14):81–88 Lanatà A, Valenza G, Scilingo E (2010) Electrodermal responses through textile electrodes. Res J Text Apparel 14(14):81–88
39.
Zurück zum Zitat Priniotakis G, Westbroek P, Van Langenhove L, Kiekens P (2005) An experimental simulation of human body behaviour during sweat production measured at textile electrodes. Int J Clothing Sci Technol 17(3/4):232–241CrossRef Priniotakis G, Westbroek P, Van Langenhove L, Kiekens P (2005) An experimental simulation of human body behaviour during sweat production measured at textile electrodes. Int J Clothing Sci Technol 17(3/4):232–241CrossRef
40.
Zurück zum Zitat Beckmann L, Neuhaus C, Medrano G, Jungbecker N, Walter M, Gries T, Leonhardt S (2010) Characterization of textile electrodes and conductors using standardized measurement setups. Physiol Meas 31:233CrossRef Beckmann L, Neuhaus C, Medrano G, Jungbecker N, Walter M, Gries T, Leonhardt S (2010) Characterization of textile electrodes and conductors using standardized measurement setups. Physiol Meas 31:233CrossRef
41.
Zurück zum Zitat Carpi F, De Rossi D (2005) Electroactive polymer-based devices for e-textiles in biomedicine. Inform Technol Biomed IEEE Trans 9(3):295–318CrossRef Carpi F, De Rossi D (2005) Electroactive polymer-based devices for e-textiles in biomedicine. Inform Technol Biomed IEEE Trans 9(3):295–318CrossRef
42.
Zurück zum Zitat Lee J, Subramanian V (2003) Organic transistors on fiber: a first step towards electronic textiles. In: IEEE international electron devices meeting, 2003 (IEDM’03) technical digest, IEEE, pp 3–8 Lee J, Subramanian V (2003) Organic transistors on fiber: a first step towards electronic textiles. In: IEEE international electron devices meeting, 2003 (IEDM’03) technical digest, IEEE, pp 3–8
43.
Zurück zum Zitat Locher I, Klemm M, Kirstein T, Troster G (2006) Design and characterization of purely textile patch antennas. Adv Packag IEEE Trans 29(4):777–788CrossRef Locher I, Klemm M, Kirstein T, Troster G (2006) Design and characterization of purely textile patch antennas. Adv Packag IEEE Trans 29(4):777–788CrossRef
44.
Zurück zum Zitat Klemm M, Troester G (2006) Textile UWB antennas for wireless body area networks. Antenn Propag IEEE Trans 54(11):3192–3197CrossRef Klemm M, Troester G (2006) Textile UWB antennas for wireless body area networks. Antenn Propag IEEE Trans 54(11):3192–3197CrossRef
45.
Zurück zum Zitat Tronquo A, Rogier H, Hertleer C, Van Langenhove L (2006) Robust planar textile antenna for wireless body lans operating in 2.45 GHz ism band. Electron Lett 42(3):142–143CrossRef Tronquo A, Rogier H, Hertleer C, Van Langenhove L (2006) Robust planar textile antenna for wireless body lans operating in 2.45 GHz ism band. Electron Lett 42(3):142–143CrossRef
46.
Zurück zum Zitat Sergio M, Manaresi N, Tartagni M, Guerrieri R, Canegallo R (2002) A textile based capacitive pressure sensor. In: Sensors, 2002. Proceedings of IEEE, vol 2, IEEE, Orlando, pp 1625–1630 Sergio M, Manaresi N, Tartagni M, Guerrieri R, Canegallo R (2002) A textile based capacitive pressure sensor. In: Sensors, 2002. Proceedings of IEEE, vol 2, IEEE, Orlando, pp 1625–1630
47.
48.
Zurück zum Zitat Reynolds J, Kincal D, Kumar A, Child A (1998) Conductivity switching in polypyrrole-coated textile fabrics as gas sensors. Synth Met 92(1):53–56CrossRef Reynolds J, Kincal D, Kumar A, Child A (1998) Conductivity switching in polypyrrole-coated textile fabrics as gas sensors. Synth Met 92(1):53–56CrossRef
49.
Zurück zum Zitat Gregory R, Kimbrell W, Kuhn H (1991) Electrically conductive non-metallic textile coatings. J Ind Text 20(3):167–175CrossRef Gregory R, Kimbrell W, Kuhn H (1991) Electrically conductive non-metallic textile coatings. J Ind Text 20(3):167–175CrossRef
50.
Zurück zum Zitat Mincica M, Pepe D, Tognetti A, Lanata A, De Rossi D, Zito D (2010) Enabling technology for heart health wireless assistance. In: 12th IEEE international conference on e-HealthNetworking applications and services, 2010 (Healthcom, 2010), IEEE, Lyon, pp 36–42 Mincica M, Pepe D, Tognetti A, Lanata A, De Rossi D, Zito D (2010) Enabling technology for heart health wireless assistance. In: 12th IEEE international conference on e-HealthNetworking applications and services, 2010 (Healthcom, 2010), IEEE, Lyon, pp 36–42
51.
Zurück zum Zitat Paradiso R, Loriga G, Taccini N, Gemignani A, Ghelarducci B (2005) Wealthy, a wearable health-care system: new frontier on etextile. J Telecommun Inform Technol 4:105–113 Paradiso R, Loriga G, Taccini N, Gemignani A, Ghelarducci B (2005) Wealthy, a wearable health-care system: new frontier on etextile. J Telecommun Inform Technol 4:105–113
52.
Zurück zum Zitat Milenkovic A, Otto C, Jovanov E (2006) Wireless sensor networks for personal health monitoring: issues and an implementation. Comput Commun 29(13–14):2521–2533CrossRef Milenkovic A, Otto C, Jovanov E (2006) Wireless sensor networks for personal health monitoring: issues and an implementation. Comput Commun 29(13–14):2521–2533CrossRef
53.
Zurück zum Zitat Gulrez T, Tognetti A, Rossi D (2010) Sensorized garment augmented 3d pervasive virtual reality system. Pervasive Comput 97–115 Gulrez T, Tognetti A, Rossi D (2010) Sensorized garment augmented 3d pervasive virtual reality system. Pervasive Comput 97–115
54.
Zurück zum Zitat Ruiz J, Shimamoto S (2006) Novel communication services based on human body and environment interaction: applications inside trains and applications for handicapped people. In: Wireless communications and networking conference, 2006 (WCNC 2006), vol 4, IEEE, Las Vegas, NV, USA, pp 2240–2245 Ruiz J, Shimamoto S (2006) Novel communication services based on human body and environment interaction: applications inside trains and applications for handicapped people. In: Wireless communications and networking conference, 2006 (WCNC 2006), vol 4, IEEE, Las Vegas, NV, USA, pp 2240–2245
55.
Zurück zum Zitat Pentland A (2004) Healthwear: medical technology becomes wearable. Computer 37(5):42–49 Pentland A (2004) Healthwear: medical technology becomes wearable. Computer 37(5):42–49
56.
Zurück zum Zitat Chrisman L, Caruana R, Carriker W (1991) Intelligent agent design issues: internal agent state and incomplete perception. In: AAAI fall symposium series: sensory aspects of robotic intelligence, Citeseer, pp 18–25 Chrisman L, Caruana R, Carriker W (1991) Intelligent agent design issues: internal agent state and incomplete perception. In: AAAI fall symposium series: sensory aspects of robotic intelligence, Citeseer, pp 18–25
57.
Zurück zum Zitat Latrè B, Braem B, Moerman I, Blondia C, Demeester P (2011) A survey on wireless body area networks. Wirel Netw 17(1):1–18CrossRef Latrè B, Braem B, Moerman I, Blondia C, Demeester P (2011) A survey on wireless body area networks. Wirel Netw 17(1):1–18CrossRef
58.
Zurück zum Zitat Girouard A, Solovey E, Mandryk R, Tan D, Nacke L, Jacob R (2010) Brain, body and bytes: psychophysiological user interaction. In: Proceedings of the 28th of the international conference extended abstracts on human factors in computing systems, ACM, pp 4433–4436 Girouard A, Solovey E, Mandryk R, Tan D, Nacke L, Jacob R (2010) Brain, body and bytes: psychophysiological user interaction. In: Proceedings of the 28th of the international conference extended abstracts on human factors in computing systems, ACM, pp 4433–4436
59.
Zurück zum Zitat Yu E (2011) Modelling strategic relationships for process reengineering. Soc Model Requir Eng 11 Yu E (2011) Modelling strategic relationships for process reengineering. Soc Model Requir Eng 11
60.
Zurück zum Zitat Van Lamsweerde A (2001) Goal-oriented requirements engineering: a guided tour. Fifth IEEE International Symposium on Requirements Engineering (Toronto, Canada), IEEE, pp 249–262 Van Lamsweerde A (2001) Goal-oriented requirements engineering: a guided tour. Fifth IEEE International Symposium on Requirements Engineering (Toronto, Canada), IEEE, pp 249–262
61.
Zurück zum Zitat Ekman P (1973) Cross-cultural studies of facial expression. In: Darwin and facial expression: a century of research in review, Academic Press, pp 169–222 Ekman P (1973) Cross-cultural studies of facial expression. In: Darwin and facial expression: a century of research in review, Academic Press, pp 169–222
62.
Zurück zum Zitat Russell J (1980) A circumplex model of affect. J Pers Soc Psychol 39(6):1161–1178CrossRef Russell J (1980) A circumplex model of affect. J Pers Soc Psychol 39(6):1161–1178CrossRef
63.
Zurück zum Zitat Valenza G, Lanata A, Scilingo E (2011) The role of nonlinear dynamics in affective valence and arousal recognition. In: IEEE transactions on affective computing, no. 99, pp 237–249 Valenza G, Lanata A, Scilingo E (2011) The role of nonlinear dynamics in affective valence and arousal recognition. In: IEEE transactions on affective computing, no. 99, pp 237–249
64.
Zurück zum Zitat Egges A, Kshirsagar S, Magnenat-Thalmann N (2003) A model for personality and emotion simulation. In: Knowledge-based intelligent information and engineering systems. Springer, pp 453–461 Egges A, Kshirsagar S, Magnenat-Thalmann N (2003) A model for personality and emotion simulation. In: Knowledge-based intelligent information and engineering systems. Springer, pp 453–461
65.
Zurück zum Zitat Posner J, Russell J, Peterson B (2005) The circumplex model of affect: an integrative approach to affective neuroscience, cognitive development, and psychopathology. Dev Psychopathol 17(03):715–734CrossRef Posner J, Russell J, Peterson B (2005) The circumplex model of affect: an integrative approach to affective neuroscience, cognitive development, and psychopathology. Dev Psychopathol 17(03):715–734CrossRef
66.
Zurück zum Zitat Van Ommeren M, Saxena S, Saraceno B (2005) Mental and social health during and after acute emergencies: emerging consensus? Bull World Health Organ 83(1):71–75 Van Ommeren M, Saxena S, Saraceno B (2005) Mental and social health during and after acute emergencies: emerging consensus? Bull World Health Organ 83(1):71–75
67.
Zurück zum Zitat Strachan M, Deary I, Ewing F, Ferguson S, Young M, Frier B (2001) Acute hypoglycemia impairs the functioning of the central but not peripheral nervous system. Physiol Behav 72(1–2):83–92CrossRef Strachan M, Deary I, Ewing F, Ferguson S, Young M, Frier B (2001) Acute hypoglycemia impairs the functioning of the central but not peripheral nervous system. Physiol Behav 72(1–2):83–92CrossRef
68.
Zurück zum Zitat Vardy J, Wong K, Yi Q, Park A, Maruff P, Wagner L, Tannock I (2006) Assessing cognitive function in cancer patients. Support Care Cancer 14(11):1111–1118CrossRef Vardy J, Wong K, Yi Q, Park A, Maruff P, Wagner L, Tannock I (2006) Assessing cognitive function in cancer patients. Support Care Cancer 14(11):1111–1118CrossRef
69.
Zurück zum Zitat Ivorra A, Daniels C, Rubinsky B (2008) Minimally obtrusive wearable device for continuous interactive cognitive and neurological assessment. Physiol Meas 29:543CrossRef Ivorra A, Daniels C, Rubinsky B (2008) Minimally obtrusive wearable device for continuous interactive cognitive and neurological assessment. Physiol Meas 29:543CrossRef
70.
Zurück zum Zitat Arnrich B, Mayora O, Bardram J, Tröster G (2010) Pervasive healthcare: paving the way for a pervasive, user-centered and preventive healthcare model. Methods Inform Med 49(1):67 Arnrich B, Mayora O, Bardram J, Tröster G (2010) Pervasive healthcare: paving the way for a pervasive, user-centered and preventive healthcare model. Methods Inform Med 49(1):67
71.
Zurück zum Zitat Mahlberg R, Walther S (2007) Actigraphy in agitated patients with dementia. Z Gerontol Geriatr 40(3):178–184CrossRef Mahlberg R, Walther S (2007) Actigraphy in agitated patients with dementia. Z Gerontol Geriatr 40(3):178–184CrossRef
72.
Zurück zum Zitat Hayes T, Pavel M, Adami A, Larimer N, Tsay I, Nutt J (2007) Distributed healthcare: simultaneous assessment of multiple individuals. IEEE Pervasive Comput 36–43 Hayes T, Pavel M, Adami A, Larimer N, Tsay I, Nutt J (2007) Distributed healthcare: simultaneous assessment of multiple individuals. IEEE Pervasive Comput 36–43
73.
Zurück zum Zitat Have G, Kolbeinsson H, Pétursson H (1991) Dementia and depression in old age: psychophysiological aspects. Acta Psychiatr Scand 83(5):329–333CrossRef Have G, Kolbeinsson H, Pétursson H (1991) Dementia and depression in old age: psychophysiological aspects. Acta Psychiatr Scand 83(5):329–333CrossRef
74.
Zurück zum Zitat Devos D, Kroumova M, Bordet R, Vodougnon H, Guieu J, Libersa C, Destee A (2003) Heart rate variability and parkinsons disease severity. J Neural Transm 110(9):997–1011CrossRef Devos D, Kroumova M, Bordet R, Vodougnon H, Guieu J, Libersa C, Destee A (2003) Heart rate variability and parkinsons disease severity. J Neural Transm 110(9):997–1011CrossRef
75.
Zurück zum Zitat Stollery B (1996) The automated cognitive test (act) system. Neurotoxicol Teratol 18(4):493–497CrossRef Stollery B (1996) The automated cognitive test (act) system. Neurotoxicol Teratol 18(4):493–497CrossRef
76.
Zurück zum Zitat Dwolatzky T, Whitehead V, Doniger G, Simon E, Schweiger A, Jaffe D, Chertkow H (2003) Validity of a novel computerized cognitive battery for mild cognitive impairment. BMC Geriatr 3(1):4CrossRef Dwolatzky T, Whitehead V, Doniger G, Simon E, Schweiger A, Jaffe D, Chertkow H (2003) Validity of a novel computerized cognitive battery for mild cognitive impairment. BMC Geriatr 3(1):4CrossRef
77.
Zurück zum Zitat Elwood R (2001) Microcog: assessment of cognitive functioning. Neuropsychol Rev 11(2):89–100CrossRef Elwood R (2001) Microcog: assessment of cognitive functioning. Neuropsychol Rev 11(2):89–100CrossRef
78.
Zurück zum Zitat Bassett J, Dabbs J (2005) A portable version of the go/no-go association task (gnat). Behav Res Methods 37(3):506–512CrossRef Bassett J, Dabbs J (2005) A portable version of the go/no-go association task (gnat). Behav Res Methods 37(3):506–512CrossRef
79.
Zurück zum Zitat Thorne D, Johnson D, Redmond D, Sing H, Belenky G, Shapiro J (2005) The Walter reed palm-held psychomotor vigilance test. Behav Res Methods 37(1):111–118CrossRef Thorne D, Johnson D, Redmond D, Sing H, Belenky G, Shapiro J (2005) The Walter reed palm-held psychomotor vigilance test. Behav Res Methods 37(1):111–118CrossRef
80.
Zurück zum Zitat Morris M, Intille S, Beaudin J (2005) Embedded assessment: overcoming barriers to early detection with pervasive computing. Pervasive Comput 333–346 Morris M, Intille S, Beaudin J (2005) Embedded assessment: overcoming barriers to early detection with pervasive computing. Pervasive Comput 333–346
81.
Zurück zum Zitat Lieberman H, Kramer F, Montain S, Niro P (2007) Field assessment and enhancement of cognitive performance: development of an ambulatory vigilance monitor. Aviat Space Environ Med 78(Suppl 1):B268–B275 Lieberman H, Kramer F, Montain S, Niro P (2007) Field assessment and enhancement of cognitive performance: development of an ambulatory vigilance monitor. Aviat Space Environ Med 78(Suppl 1):B268–B275
82.
Zurück zum Zitat Kurs A, Karalis A, Moffatt R, Joannopoulos J, Fisher P, Soljačić M (2007) Wireless power transfer via strongly coupled magnetic resonances. Science 317(5834):83CrossRef Kurs A, Karalis A, Moffatt R, Joannopoulos J, Fisher P, Soljačić M (2007) Wireless power transfer via strongly coupled magnetic resonances. Science 317(5834):83CrossRef
83.
Zurück zum Zitat Hardell L, Sage C (2008) Biological effects from electromagnetic field exposure and public exposure standards. Biomed Pharmacother 62(2):104–109 Hardell L, Sage C (2008) Biological effects from electromagnetic field exposure and public exposure standards. Biomed Pharmacother 62(2):104–109
Metadaten
Titel
Smart Textiles: Technology and Wireless System Network Applications
verfasst von
Antonio Lanatà
Enzo Pasquale Scilingo
Copyright-Jahr
2013
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/5346_2012_29