Skip to main content
Erschienen in: Journal of Elasticity 1-2/2021

11.08.2021

The Effect of an Implanted Filter on Valsalva-Compression and Respiratory-Compression of the Inferior Vena Cava

verfasst von: Attila Kossa, Robert M. McMeeking

Erschienen in: Journal of Elasticity | Ausgabe 1-2/2021

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

We carry out computational simulations of the Valsalva compression of an inferior vena cava (IVC) with a filter implanted in it. We find that when we treat the IVC wall as simply a boundary between 2 fluids and apply an external pressure on the IVC, the deformation magnitudes and patterns do not agree with data in the literature. We conclude that IVC compression is mainly caused by solid bodies (i.e. tissue and organs) compressing the IVC, and develop a model to simulate this phenomenon. We calibrate our model to data in the literature for Valsalva compression with and without an implanted filter. We then use our approach to predict the area reduction of the IVC during breathing when 2 different types of filters are implanted. Not surprisingly, we find that a compliant filter is less able to resist the compression of the IVC during respiration than a stiffer one, and we quantify the difference. We anticipate that, with further development, our model can be used to make assessments of design and testing parameters that can help to avoid fatigue failure of a filter that is subjected to millions of compressions due to breathing.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Netter, F.H.: Atlas of Human Anatomy. Elsevier, Amsterdam (2019) Netter, F.H.: Atlas of Human Anatomy. Elsevier, Amsterdam (2019)
3.
Zurück zum Zitat Grassi, C.J.: Inferior vena caval filters: analysis of five currently available devices. Am. J. Roentgenol. 156, 813–821 (1991) CrossRef Grassi, C.J.: Inferior vena caval filters: analysis of five currently available devices. Am. J. Roentgenol. 156, 813–821 (1991) CrossRef
4.
Zurück zum Zitat Neuerburg, J., Günther, R.W., Rassmussen, E., Vorwerk, D., Tonn, K., Handt, S., Küpper, W., Hansen, J.V.: New retrievable percutaneous vena cava filter: experimental in vitro and in vivo evaluation. Cardiovasc. Interv. Radiol. 16, 224–229 (1993). https://doi.org/10.1007/BF02602965CrossRef Neuerburg, J., Günther, R.W., Rassmussen, E., Vorwerk, D., Tonn, K., Handt, S., Küpper, W., Hansen, J.V.: New retrievable percutaneous vena cava filter: experimental in vitro and in vivo evaluation. Cardiovasc. Interv. Radiol. 16, 224–229 (1993). https://​doi.​org/​10.​1007/​BF02602965CrossRef
6.
Zurück zum Zitat Grant, E., Rendano, F., Sevinc, E., Gammelgaard, J., Holm, H., Grovall, S.: Normal inferior vena cava: Caliber changes observed by dynamic ultrasound. Am. J. Roentgenol. 135, 335–338 (1980) CrossRef Grant, E., Rendano, F., Sevinc, E., Gammelgaard, J., Holm, H., Grovall, S.: Normal inferior vena cava: Caliber changes observed by dynamic ultrasound. Am. J. Roentgenol. 135, 335–338 (1980) CrossRef
7.
8.
Zurück zum Zitat Klabunde, R.E.: Cardiovascular Physiology Concepts, 2nd edn. LWW, Philadelphia (2011) Klabunde, R.E.: Cardiovascular Physiology Concepts, 2nd edn. LWW, Philadelphia (2011)
9.
Zurück zum Zitat Tibbs, D.J.: Varicose Veins and Related Disorders. Butterworth-Heinemann, Stoneham (1991) Tibbs, D.J.: Varicose Veins and Related Disorders. Butterworth-Heinemann, Stoneham (1991)
19.
Zurück zum Zitat Johnson, M.S., Nemcek, A.A. Jr., Benenati, J.F., Baumann, D.S., Dolmatch, B.L., Kaufman, J.A., Garcia, M.J., Stecker, M.S., Venbrux, A.C., Haskal, Z.J., Avelar, R.L.: The safety and effectiveness of the retrievable Option inferior vena cava filter: a United States prospective multicenter clinical study. J. Vasc. Interv. Radiol. 21, 1173–1184 (2010). https://doi.org/10.1016/j.jvir.2010.04.004CrossRef Johnson, M.S., Nemcek, A.A. Jr., Benenati, J.F., Baumann, D.S., Dolmatch, B.L., Kaufman, J.A., Garcia, M.J., Stecker, M.S., Venbrux, A.C., Haskal, Z.J., Avelar, R.L.: The safety and effectiveness of the retrievable Option inferior vena cava filter: a United States prospective multicenter clinical study. J. Vasc. Interv. Radiol. 21, 1173–1184 (2010). https://​doi.​org/​10.​1016/​j.​jvir.​2010.​04.​004CrossRef
20.
Zurück zum Zitat Stavropoulos, S.W., Sing, R.F., Elmasri, F., Silver, M.J., Powell, A., Lynch, F.C., Aal, A.K.A., Lansky, A.J., Settlage, R.A., Muhs, B.E.: The Denali trial: an interim analysis of a prospective, multicenter study of the Denali retrievable inferior vena cava filter. J. Vasc. Interv. Radiol. 25, 1497–1505.e1 (2014). https://doi.org/10.1016/j.jvir.2014.07.001CrossRef Stavropoulos, S.W., Sing, R.F., Elmasri, F., Silver, M.J., Powell, A., Lynch, F.C., Aal, A.K.A., Lansky, A.J., Settlage, R.A., Muhs, B.E.: The Denali trial: an interim analysis of a prospective, multicenter study of the Denali retrievable inferior vena cava filter. J. Vasc. Interv. Radiol. 25, 1497–1505.e1 (2014). https://​doi.​org/​10.​1016/​j.​jvir.​2014.​07.​001CrossRef
22.
23.
Zurück zum Zitat Lyon, S.M., Riojas, G.E., Uberoi, R., Patel, J., Lipp, M.E.B., Plant, G.R., De Gregorio, M.A., Günther, R.W., Voorhees, W.D., McCann-Brown, J.A.: Short- and long-term retrievability of the Celect vena cava filter: results from a multi-institutional registry. J. Vasc. Interv. Radiol. 20, 1441–1448 (2009). https://doi.org/10.1016/j.jvir.2009.07.038CrossRef Lyon, S.M., Riojas, G.E., Uberoi, R., Patel, J., Lipp, M.E.B., Plant, G.R., De Gregorio, M.A., Günther, R.W., Voorhees, W.D., McCann-Brown, J.A.: Short- and long-term retrievability of the Celect vena cava filter: results from a multi-institutional registry. J. Vasc. Interv. Radiol. 20, 1441–1448 (2009). https://​doi.​org/​10.​1016/​j.​jvir.​2009.​07.​038CrossRef
33.
Zurück zum Zitat Special 510(k): Device Modification, K121057, Günther Tulip Vena Cava Filter Sets and Cook Celect Vena Cava Filter Sets, Cook Medical–William Cook Europe ApS (2012) Special 510(k): Device Modification, K121057, Günther Tulip Vena Cava Filter Sets and Cook Celect Vena Cava Filter Sets, Cook Medical–William Cook Europe ApS (2012)
34.
Zurück zum Zitat Nicolás, M., Lucea, B., Laborda, A., Peña, E., De Gregorio, M.A., Martínez, M.A., Malvè, M.: Influence of a commercial antithrombotic filter on the caval blood flow during neutra and Valsalva maneuver. J. Med. Devices, Trans. ASME. 11, 1–11 (2017). https://doi.org/10.1115/1.4035983CrossRef Nicolás, M., Lucea, B., Laborda, A., Peña, E., De Gregorio, M.A., Martínez, M.A., Malvè, M.: Influence of a commercial antithrombotic filter on the caval blood flow during neutra and Valsalva maneuver. J. Med. Devices, Trans. ASME. 11, 1–11 (2017). https://​doi.​org/​10.​1115/​1.​4035983CrossRef
35.
Zurück zum Zitat Aycock, K.I., Campbell, R.L., Manning, K.B., Sastry, S.P., Shontz, S.M., Lynch, F.C., Craven, B.A.: A computational method for predicting inferior vena cava filter performance on a patient-specific basis. J. Biomech. Eng. 136, 1–14 (2014). https://doi.org/10.1115/1.4027612CrossRef Aycock, K.I., Campbell, R.L., Manning, K.B., Sastry, S.P., Shontz, S.M., Lynch, F.C., Craven, B.A.: A computational method for predicting inferior vena cava filter performance on a patient-specific basis. J. Biomech. Eng. 136, 1–14 (2014). https://​doi.​org/​10.​1115/​1.​4027612CrossRef
36.
38.
Zurück zum Zitat Dassault Systèmes: Abaqus version 2019, Providence RI (2019) Dassault Systèmes: Abaqus version 2019, Providence RI (2019)
39.
Zurück zum Zitat Anonymous: Cobalt Monograph. Brussels: Centre d’information du cobalt (1960) Anonymous: Cobalt Monograph. Brussels: Centre d’information du cobalt (1960)
51.
Zurück zum Zitat Ogneva, I.V., Ushakov, I.B.: The transversal stiffness of skeletal muscle fibers and cardiomyocytes in control and after simulated microgravity. In: Frewin, C. (ed.) At. Force Microsc. Investig. into Biol. – From Cell to Protein, pp. 325–354 (2012). https://doi.org/10.5772/36457CrossRef Ogneva, I.V., Ushakov, I.B.: The transversal stiffness of skeletal muscle fibers and cardiomyocytes in control and after simulated microgravity. In: Frewin, C. (ed.) At. Force Microsc. Investig. into Biol. – From Cell to Protein, pp. 325–354 (2012). https://​doi.​org/​10.​5772/​36457CrossRef
52.
Zurück zum Zitat Auricchio, F., Taylor, R.L.: Shape-memory alloys: modelling and numerical simulations of the finite-strain superelastic behavior. Comput. Methods Appl. Mech. Eng. 143, 175–194 (1997) ADSCrossRef Auricchio, F., Taylor, R.L.: Shape-memory alloys: modelling and numerical simulations of the finite-strain superelastic behavior. Comput. Methods Appl. Mech. Eng. 143, 175–194 (1997) ADSCrossRef
53.
Zurück zum Zitat Auricchio, F., Taylor, R.L., Lubliner, J.: Shape-memory alloys: macromodelling and numerical simulations of the superelastic behavior. Comput. Methods Appl. Mech. Eng. 146, 281–312 (1997) ADSCrossRef Auricchio, F., Taylor, R.L., Lubliner, J.: Shape-memory alloys: macromodelling and numerical simulations of the superelastic behavior. Comput. Methods Appl. Mech. Eng. 146, 281–312 (1997) ADSCrossRef
Metadaten
Titel
The Effect of an Implanted Filter on Valsalva-Compression and Respiratory-Compression of the Inferior Vena Cava
verfasst von
Attila Kossa
Robert M. McMeeking
Publikationsdatum
11.08.2021
Verlag
Springer Netherlands
Erschienen in
Journal of Elasticity / Ausgabe 1-2/2021
Print ISSN: 0374-3535
Elektronische ISSN: 1573-2681
DOI
https://doi.org/10.1007/s10659-021-09850-8

Weitere Artikel der Ausgabe 1-2/2021

Journal of Elasticity 1-2/2021 Zur Ausgabe

EditorialNotes

Preface

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.