Abstract

The aim of this work is to quantify individual and regional differences in the relative concentration of gamma-aminobutyric acid (GABA) in human brain with in vivo magnetic resonance spectroscopy. Spectral editing Mescher–Garwood point resolved spectroscopy (MEGA-PRESS) sequence and GABA analysis toolkit (Gannet) were used to detect and quantify GABA in anterior cingulate cortex (ACC) and occipital cortex (OCC) of healthy volunteers. Residual bootstrap, a model-based statistical analysis technique, was applied to resample the fitting residuals of GABA from the Gaussian fitting model (referred to as GABA+ thereafter) in both individual and group data of ACC and OCC. The inter-subject coefficient of variation (CV) of GABA+ in OCC (20.66 %) and ACC (12.55 %) with residual bootstrap was lower than that of a standard Gaussian model analysis (21.58 % and 16.73 % for OCC and ACC, respectively). The intra-subject uncertainty and CV of OCC were lower than that of ACC in both analyses. The residual bootstrap analysis thus provides a more robust uncertainty estimation of individual and group GABA+ detection in different brain regions, which may be useful in our understanding of GABA biochemistry in brain and its use for the diagnosis of related neuropsychiatric diseases.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310CrossRefPubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310CrossRefPubMed
2.
Zurück zum Zitat Bogner W, Gruber S, Doelken M, Stadlbauer A, Ganslandt O, Boettcher U, Trattnig S, Doerfler A, Stefan H, Hammen T (2010) In vivo quantification of intracerebral GABA by single-voxel (1)H-MRS—How reproducible are the results? Eur J Radiol 73(3):526–531CrossRefPubMed Bogner W, Gruber S, Doelken M, Stadlbauer A, Ganslandt O, Boettcher U, Trattnig S, Doerfler A, Stefan H, Hammen T (2010) In vivo quantification of intracerebral GABA by single-voxel (1)H-MRS—How reproducible are the results? Eur J Radiol 73(3):526–531CrossRefPubMed
3.
Zurück zum Zitat Bolan PJ, Auffermann WF, Henry PG, Garwood M (2004) Feasibility of computer-intensive methods for estimating the variance of spectral fitting parameters. In: Proceedings of the 12th annual meeting ISMRM (abstract 304), Kyoto Bolan PJ, Auffermann WF, Henry PG, Garwood M (2004) Feasibility of computer-intensive methods for estimating the variance of spectral fitting parameters. In: Proceedings of the 12th annual meeting ISMRM (abstract 304), Kyoto
4.
Zurück zum Zitat Bolliger CS, Boesch C, Kreis R (2013) On the use of Cramer–Rao minimum variance bounds for the design of magnetic resonance spectroscopy experiments. Neuroimage 83:1031–1040CrossRefPubMed Bolliger CS, Boesch C, Kreis R (2013) On the use of Cramer–Rao minimum variance bounds for the design of magnetic resonance spectroscopy experiments. Neuroimage 83:1031–1040CrossRefPubMed
5.
Zurück zum Zitat Bush G, Luu P, Posner MI (2000) Cognitive and emotional influences in anterior cingulate cortex. Trends Cogn Sci 4(6):215–222CrossRefPubMed Bush G, Luu P, Posner MI (2000) Cognitive and emotional influences in anterior cingulate cortex. Trends Cogn Sci 4(6):215–222CrossRefPubMed
6.
Zurück zum Zitat Choi IY, Lee SP, Merkle H, Shen J (2004) Single-shot two-echo technique for simultaneous measurement of GABA and creatine in the human brain in vivo. Magn Reson Med 51(6):1115–1121CrossRefPubMed Choi IY, Lee SP, Merkle H, Shen J (2004) Single-shot two-echo technique for simultaneous measurement of GABA and creatine in the human brain in vivo. Magn Reson Med 51(6):1115–1121CrossRefPubMed
7.
Zurück zum Zitat Chung S, Lu Y, Henry RG (2006) Comparison of bootstrap approaches for estimation of uncertainties of DTI parameters. Neuroimage 33(2):531–541CrossRefPubMed Chung S, Lu Y, Henry RG (2006) Comparison of bootstrap approaches for estimation of uncertainties of DTI parameters. Neuroimage 33(2):531–541CrossRefPubMed
8.
Zurück zum Zitat Dobbe JG, Pre KJ, Kloen P, Blankevoort L, Streekstra GJ (2011) Computer-assisted and patient-specific 3-D planning and evaluation of a single-cut rotational osteotomy for complex long-bone deformities. Med Biol Eng Comput 49:1363–1370CrossRefPubMedPubMedCentral Dobbe JG, Pre KJ, Kloen P, Blankevoort L, Streekstra GJ (2011) Computer-assisted and patient-specific 3-D planning and evaluation of a single-cut rotational osteotomy for complex long-bone deformities. Med Biol Eng Comput 49:1363–1370CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Edden RA, Puts NA, Harris AD, Barker PB, Evans CJ (2014) Gannet: a batch-processing tool for the quantitative analysis of gamma-aminobutyric acid-edited MR spectroscopy spectra. J Magn Reson Imaging 40(6):1445–1452CrossRefPubMed Edden RA, Puts NA, Harris AD, Barker PB, Evans CJ (2014) Gannet: a batch-processing tool for the quantitative analysis of gamma-aminobutyric acid-edited MR spectroscopy spectra. J Magn Reson Imaging 40(6):1445–1452CrossRefPubMed
10.
Zurück zum Zitat Evans CJ, Puts NA, Robson SE, Boy F, McGonigle DJ, Sumner P, Singh KD, Edden RA (2013) Subtraction artifacts and frequency (mis-)alignment in J-difference GABA editing. J Magn Reson Imaging 38(4):970–975CrossRefPubMed Evans CJ, Puts NA, Robson SE, Boy F, McGonigle DJ, Sumner P, Singh KD, Edden RA (2013) Subtraction artifacts and frequency (mis-)alignment in J-difference GABA editing. J Magn Reson Imaging 38(4):970–975CrossRefPubMed
11.
Zurück zum Zitat Gao F, Edden RA, Li M, Puts NA, Wang G, Liu C, Zhao B, Wang H, Bai X, Zhao C, Wang X, Barker PB (2013) Edited magnetic resonance spectroscopy detects an age-related decline in brain GABA levels. Neuroimage 78:75–82CrossRefPubMedPubMedCentral Gao F, Edden RA, Li M, Puts NA, Wang G, Liu C, Zhao B, Wang H, Bai X, Zhao C, Wang X, Barker PB (2013) Edited magnetic resonance spectroscopy detects an age-related decline in brain GABA levels. Neuroimage 78:75–82CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Harris AD, Puts NAJ, Barker PB, Edden RAE (2015) Spectral-editing measurements of GABA in the human brain with and without macromolecule suppression. Magn Reson Med 74:1523–1529CrossRefPubMed Harris AD, Puts NAJ, Barker PB, Edden RAE (2015) Spectral-editing measurements of GABA in the human brain with and without macromolecule suppression. Magn Reson Med 74:1523–1529CrossRefPubMed
13.
Zurück zum Zitat Haroon HA, Morris DM, Embleton KV, Alexander DC, Parker GJM (2009) Using the model-based residual bootstrap to quantify uncertainty in fiber orientations from Q-Ball analysis. IEEE Trans Med Imaging 28(4):535–550CrossRefPubMed Haroon HA, Morris DM, Embleton KV, Alexander DC, Parker GJM (2009) Using the model-based residual bootstrap to quantify uncertainty in fiber orientations from Q-Ball analysis. IEEE Trans Med Imaging 28(4):535–550CrossRefPubMed
14.
Zurück zum Zitat Johnson RW (2001) An introduction to the bootstrap. Teach Stat 23(2):49–54CrossRef Johnson RW (2001) An introduction to the bootstrap. Teach Stat 23(2):49–54CrossRef
15.
Zurück zum Zitat Mescher M, Merkle H, Kirsch J, Garwood M, Gruetter R (1998) Simultaneous in vivo spectral editing and water suppression. NMR Biomed 11:466–472CrossRef Mescher M, Merkle H, Kirsch J, Garwood M, Gruetter R (1998) Simultaneous in vivo spectral editing and water suppression. NMR Biomed 11:466–472CrossRef
16.
Zurück zum Zitat Mullins PG, McGonigle DJ, O’Gorman RL, Puts NAJ, Vidyasagar R, Evans CJ, Cardiff Symposium on MRS of GABA, Edden RAE (2014) Current practice in the use of MEGA-PRESS spectroscopy for the detection of GABA. Neuroimage 86:43–52CrossRefPubMed Mullins PG, McGonigle DJ, O’Gorman RL, Puts NAJ, Vidyasagar R, Evans CJ, Cardiff Symposium on MRS of GABA, Edden RAE (2014) Current practice in the use of MEGA-PRESS spectroscopy for the detection of GABA. Neuroimage 86:43–52CrossRefPubMed
17.
Zurück zum Zitat Near J, Ho YC, Sandberg K, Kumaragamage C, Blicher JU (2014) Long-term reproducibility of GABA magnetic resonance spectroscopy. Neuroimage 99:191–196CrossRefPubMed Near J, Ho YC, Sandberg K, Kumaragamage C, Blicher JU (2014) Long-term reproducibility of GABA magnetic resonance spectroscopy. Neuroimage 99:191–196CrossRefPubMed
18.
Zurück zum Zitat Polders DL, Leemans A, Luijten PR, Hoogduin H (2012) Uncertainty estimations for quantitative in vivo MRI T1 mapping. J Magn Reson 224:53–60CrossRefPubMed Polders DL, Leemans A, Luijten PR, Hoogduin H (2012) Uncertainty estimations for quantitative in vivo MRI T1 mapping. J Magn Reson 224:53–60CrossRefPubMed
19.
Zurück zum Zitat Provencher SW (2001) Automatic quantitation of localized in vivo 1H spectra with LCModel. NMR Biomed 14(4):260–264CrossRefPubMed Provencher SW (2001) Automatic quantitation of localized in vivo 1H spectra with LCModel. NMR Biomed 14(4):260–264CrossRefPubMed
20.
Zurück zum Zitat Puts NA, Edden RA (2012) In vivo magnetic resonance spectroscopy of GABA: a methodological review. Prog Nucl Magn Reson Spectrosc 60:29–41CrossRefPubMed Puts NA, Edden RA (2012) In vivo magnetic resonance spectroscopy of GABA: a methodological review. Prog Nucl Magn Reson Spectrosc 60:29–41CrossRefPubMed
21.
Zurück zum Zitat Rothman DL, Petroff OAC, Behar KL, Mattson RH (1993) Localized 1H NMR measurements of γ-aminobutyric acid in human. Proc Natl Acad Sci USA 90:5662–5666CrossRefPubMedPubMedCentral Rothman DL, Petroff OAC, Behar KL, Mattson RH (1993) Localized 1H NMR measurements of γ-aminobutyric acid in human. Proc Natl Acad Sci USA 90:5662–5666CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Rugelj D, Hrastnik A, Sevsek F, Vauhnik R (2015) Reliability of modified sensory interaction test as measured with force platform. Med Biol Eng Comput 53:525–534CrossRefPubMedPubMedCentral Rugelj D, Hrastnik A, Sevsek F, Vauhnik R (2015) Reliability of modified sensory interaction test as measured with force platform. Med Biol Eng Comput 53:525–534CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Stephenson MC, Gunner F, Napolitano A, Greenhaff PL, Macdonald IA, Saeed N, Vennart W, Francis ST, Morris PG (2011) Applications of multi-nuclear magnetic resonance spectroscopy at 7T. World J Radiol 3:105–113CrossRefPubMedPubMedCentral Stephenson MC, Gunner F, Napolitano A, Greenhaff PL, Macdonald IA, Saeed N, Vennart W, Francis ST, Morris PG (2011) Applications of multi-nuclear magnetic resonance spectroscopy at 7T. World J Radiol 3:105–113CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Terpstra M, Ugurbil K, Gruetter R (2002) Direct in vivo measurement of human cerebral GABA concentration using MEGA-editing at 7 Tesla. Magn Reson Med 47(5):1009–1012CrossRefPubMed Terpstra M, Ugurbil K, Gruetter R (2002) Direct in vivo measurement of human cerebral GABA concentration using MEGA-editing at 7 Tesla. Magn Reson Med 47(5):1009–1012CrossRefPubMed
25.
Zurück zum Zitat van der Veen JW, Shen J (2013) Regional difference in GABA levels between medial prefrontal and occipital cortices. J Magn Reson Imaging 38:745–750CrossRefPubMedPubMedCentral van der Veen JW, Shen J (2013) Regional difference in GABA levels between medial prefrontal and occipital cortices. J Magn Reson Imaging 38:745–750CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Zhu T, Hu R, Qiu X, Taylor M, Tso Y, Yiannoutsos C, Navia B, Mori S, Ekholm S, Schifitto G, Zhong J (2011) Quantification of accuracy and precision of multi-center DTI measurements: a diffusion phantom and human brain study. Neuroimage 56(3):1398–1411CrossRefPubMedPubMedCentral Zhu T, Hu R, Qiu X, Taylor M, Tso Y, Yiannoutsos C, Navia B, Mori S, Ekholm S, Schifitto G, Zhong J (2011) Quantification of accuracy and precision of multi-center DTI measurements: a diffusion phantom and human brain study. Neuroimage 56(3):1398–1411CrossRefPubMedPubMedCentral
Metadaten
Titel
Uncertainty assessment of gamma-aminobutyric acid concentration of different brain regions in individual and group using residual bootstrap analysis
verfasst von
Meng Chen
Congyu Liao
Song Chen
Qiuping Ding
Darong Zhu
Hui Liu
Xu Yan
Jianhui Zhong
Publikationsdatum
01.10.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 6/2017
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-016-1579-5

Weitere Artikel der Ausgabe 6/2017

Medical & Biological Engineering & Computing 6/2017 Zur Ausgabe