Skip to main content

2022 | OriginalPaper | Buchkapitel

Using PPG and Machine Learning to Measure Blood Pressure

verfasst von : G. S. Cardoso, M. G. Lucas, S. S. Cardoso, J. C. M. Ruzicki, A. A. S. Junior

Erschienen in: XXVII Brazilian Congress on Biomedical Engineering

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Measurement of blood pressure is critical for patients with cardiovascular disease. Using a cuff sphygmomanometer with non-invasive registration is currently the most common practice since its fast and does not require an experienced operator. However, it does not allow continuous pressure monitoring and the discomfort of the procedure can discourage consistent use. Photoplethysmography (PPG) is a technique increasingly used for non-invasive, portable devices to monitor arterial oxygen saturation (SpO\(_2\)), heart rate and, more recently, for glycemic control. In this study, we evaluate different methods to estimate blood pressure using PPG. Two methods presented are adapted from the literature, while the third is an improvement proposal. Multiple linear regression (MLR), artificial neural network (ANN), support vector machine regression (SVR) and decison tree regression (DTR) using temporal and spectral PPG features are evaluated. Principal component analysis (PCA) is used in order to reduce dimensionality. The MIMIC (Multiparameter Intelligent Monitoring in Intensive Care) database is used to train and evaluate the approaches. Results indicate that the proposal improves diastolic (DBP) and systolic (SBP) blood pressure estimation with mean absolute errors (MAE) of 6.52 ± 5.75 mmHg and 13.19 ± 11.90 mmHg, respectively.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
[1]
Zurück zum Zitat Malachias MVB, Souza WKSB, Plavnik FL et al (2016) 7th Brazilian guideline of arterial hypertension. Arq Bras Cardiol 107:1–83 Malachias MVB, Souza WKSB, Plavnik FL et al (2016) 7th Brazilian guideline of arterial hypertension. Arq Bras Cardiol 107:1–83
[2]
Zurück zum Zitat Brasil (2006) Systemic arterial hypertension for the unified health system. Ministério da Saúde, Brasília Brasil (2006) Systemic arterial hypertension for the unified health system. Ministério da Saúde, Brasília
[3]
Zurück zum Zitat Wang B, Li R, Lu Z, Huang Y (2020) Does comorbidity increase the risk of patients with COVID-19: evidence from meta-analysis. Aging (Albany NY) 12:6049–6057 Wang B, Li R, Lu Z, Huang Y (2020) Does comorbidity increase the risk of patients with COVID-19: evidence from meta-analysis. Aging (Albany NY) 12:6049–6057
[4]
Zurück zum Zitat Hall JE (2017) Guyton e Hall tratado de fisiologia médica. Elsevier Brasil, Rio de Janeiro Hall JE (2017) Guyton e Hall tratado de fisiologia médica. Elsevier Brasil, Rio de Janeiro
[5]
Zurück zum Zitat Shioya K, Dohi T (2013) Blood pressure measurement device based on the arterial tonometry method with micro triaxial force sensor. In: 2013 Transducers & Eurosensors XXVII: the 17th international conference on solid-state sensors, actuators and microsystems (TRANSDUCERS & EUROSENSORS XXVII), pp 2389–2392 Shioya K, Dohi T (2013) Blood pressure measurement device based on the arterial tonometry method with micro triaxial force sensor. In: 2013 Transducers & Eurosensors XXVII: the 17th international conference on solid-state sensors, actuators and microsystems (TRANSDUCERS & EUROSENSORS XXVII), pp 2389–2392
[6]
Zurück zum Zitat Meidert AS, Saugel B (2018) Techniques for non-invasive monitoring of arterial blood pressure. Front Med 4:231 Meidert AS, Saugel B (2018) Techniques for non-invasive monitoring of arterial blood pressure. Front Med 4:231
[7]
Zurück zum Zitat Webster JG (1997) Design of pulse oximeters. CRC Press, New York Webster JG (1997) Design of pulse oximeters. CRC Press, New York
[8]
Zurück zum Zitat Rosenthal RD, Paynter LN, Mackie LH (1991) Non-invasive measurement of blood glucose 1991. US Patent 5,028,787 Rosenthal RD, Paynter LN, Mackie LH (1991) Non-invasive measurement of blood glucose 1991. US Patent 5,028,787
[9]
Zurück zum Zitat Kachuee M, Kiani MM, Mohammadzade H, Shabany M (2015) Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time. In: 2015 IEEE international symposium on circuits and systems (ISCAS), pp 1006–1009 Kachuee M, Kiani MM, Mohammadzade H, Shabany M (2015) Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time. In: 2015 IEEE international symposium on circuits and systems (ISCAS), pp 1006–1009
[10]
Zurück zum Zitat Nabeel PM, Jayaraj J, Mohanasankar S (2017) Single-source PPG-based local pulse wave velocity measurement: a potential cuffless blood pressure estimation technique. Physiol Measure 38:2122–2140CrossRef Nabeel PM, Jayaraj J, Mohanasankar S (2017) Single-source PPG-based local pulse wave velocity measurement: a potential cuffless blood pressure estimation technique. Physiol Measure 38:2122–2140CrossRef
[11]
Zurück zum Zitat Kurylyak Y, Lamonaca F, Grimaldi D (2013) A neural network-based method for continuous blood pressure estimation from a PPG signal. In: 2013 IEEE international instrumentation and measurement technology conference (I2MTC), pp 280–283 Kurylyak Y, Lamonaca F, Grimaldi D (2013) A neural network-based method for continuous blood pressure estimation from a PPG signal. In: 2013 IEEE international instrumentation and measurement technology conference (I2MTC), pp 280–283
[12]
Zurück zum Zitat Khalid SG, Zhang J, Chen F, Zheng D (2018) Blood pressure estimation using photoplethysmography only: comparison between different machine learning approaches. J Healthcare Eng Khalid SG, Zhang J, Chen F, Zheng D (2018) Blood pressure estimation using photoplethysmography only: comparison between different machine learning approaches. J Healthcare Eng
[13]
Zurück zum Zitat Xing X, Sun M (2016) Optical blood pressure estimation with photoplethysmography and FFT-based neural networks. Biomed Opt Express 7:3007–3020CrossRef Xing X, Sun M (2016) Optical blood pressure estimation with photoplethysmography and FFT-based neural networks. Biomed Opt Express 7:3007–3020CrossRef
[14]
Zurück zum Zitat Slapničar G, Mlakar N, Luštrek M (2019) Blood pressure estimation from photoplethysmogram using a spectro-temporal deep neural network. Sensors 19:3420CrossRef Slapničar G, Mlakar N, Luštrek M (2019) Blood pressure estimation from photoplethysmogram using a spectro-temporal deep neural network. Sensors 19:3420CrossRef
[15]
Zurück zum Zitat AAMI (1987) American national standards for electronic or automated sphygmomanometers. In: ANSI/AAMI SP 10-1987 AAMI (1987) American national standards for electronic or automated sphygmomanometers. In: ANSI/AAMI SP 10-1987
[16]
Zurück zum Zitat Liu M, Po LM, Fu H (2017) Cuffless blood pressure estimation based on photoplethysmography signal and its second derivative. Int J Comput Theory Eng 9:202–206CrossRef Liu M, Po LM, Fu H (2017) Cuffless blood pressure estimation based on photoplethysmography signal and its second derivative. Int J Comput Theory Eng 9:202–206CrossRef
[17]
Zurück zum Zitat Bersano N, Sanson H (2018) Non-invasive blood pressure estimation from photoplethysmography signals using artificial neural networks. In: 2018 20th International conference on advanced communication technology (ICACT), pp 29–35 Bersano N, Sanson H (2018) Non-invasive blood pressure estimation from photoplethysmography signals using artificial neural networks. In: 2018 20th International conference on advanced communication technology (ICACT), pp 29–35
[18]
Zurück zum Zitat Goldberger AL, Amaral LAN, Glass L et al (2000) PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals. Circulation 101:e215–e220 Goldberger AL, Amaral LAN, Glass L et al (2000) PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals. Circulation 101:e215–e220
[19]
Zurück zum Zitat Kavsaoğlu AR, Polat K, Bozkurt MR (2016) An innovative peak detection algorithm for photoplethysmography signals: an adaptive segmentation method. Turkish J Electr Eng & Comput Sci 24:1782–1796CrossRef Kavsaoğlu AR, Polat K, Bozkurt MR (2016) An innovative peak detection algorithm for photoplethysmography signals: an adaptive segmentation method. Turkish J Electr Eng & Comput Sci 24:1782–1796CrossRef
[20]
Zurück zum Zitat Mousavi SS, Firouzmand M, Charmi M, Hemmati M, Moghadam M, Ghorbani Y (2019) Blood pressure estimation from appropriate and inappropriate PPG signals using A whole-based method. Biomed Signal Process Control 47:196–206CrossRef Mousavi SS, Firouzmand M, Charmi M, Hemmati M, Moghadam M, Ghorbani Y (2019) Blood pressure estimation from appropriate and inappropriate PPG signals using A whole-based method. Biomed Signal Process Control 47:196–206CrossRef
[21]
Zurück zum Zitat Robnik-Šikonja M, Kononenko I (1997) An adaptation of relief for attribute estimation in regression. In: Machine learning: proceedings of the fourteenth international conference (ICML’97), vol 5, pp 296–304 Robnik-Šikonja M, Kononenko I (1997) An adaptation of relief for attribute estimation in regression. In: Machine learning: proceedings of the fourteenth international conference (ICML’97), vol 5, pp 296–304
[22]
Zurück zum Zitat Gaurav A, Maheedhar M, Tiwari VN, Narayanan R (2016) Cuff-less PPG based continuous blood pressure monitoring—A smartphone based approach. In: 2016 38th Annual international conference of the IEEE engineering in medicine and biology society (EMBC), pp 607–610 Gaurav A, Maheedhar M, Tiwari VN, Narayanan R (2016) Cuff-less PPG based continuous blood pressure monitoring—A smartphone based approach. In: 2016 38th Annual international conference of the IEEE engineering in medicine and biology society (EMBC), pp 607–610
[23]
Zurück zum Zitat Zhang Y, Feng Z (2017) A SVM method for continuous blood pressure estimation from a PPG signal. In: Proceedings of the 9th international conference on machine learning and computing, New York, NY, USA, pp 128–132 Zhang Y, Feng Z (2017) A SVM method for continuous blood pressure estimation from a PPG signal. In: Proceedings of the 9th international conference on machine learning and computing, New York, NY, USA, pp 128–132
Metadaten
Titel
Using PPG and Machine Learning to Measure Blood Pressure
verfasst von
G. S. Cardoso
M. G. Lucas
S. S. Cardoso
J. C. M. Ruzicki
A. A. S. Junior
Copyright-Jahr
2022
DOI
https://doi.org/10.1007/978-3-030-70601-2_278

Neuer Inhalt