Skip to main content
Erschienen in: Experimental Mechanics 4/2011

01.04.2011

Voxel-Scale Digital Volume Correlation

verfasst von: H. Leclerc, J.-N. Périé, S. Roux, F. Hild

Erschienen in: Experimental Mechanics | Ausgabe 4/2011

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Among various correlation techniques to find the displacement field of a volume imaged by X-ray tomography at several deformation states, a new approach is proposed where the displacement is measured down to the voxel scale and determined from a mechanically regularized system using the equilibrium gap method, and an additional boundary regularization. It is shown that even if the underlying material behavior is not very well known, this approach leads to extremely small correlation residuals. An excellent stability of the estimated displacement field for noisy (reconstructed) volumes is also observed.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Baruchel J, Buffière J-Y, Maire E, Merle P, Peix G (2000) X-ray tomography in material sciences. Hermes Science, Paris Baruchel J, Buffière J-Y, Maire E, Merle P, Peix G (2000) X-ray tomography in material sciences. Hermes Science, Paris
2.
Zurück zum Zitat Maire E, Buffière J-Y, Salvo L, Blandin J-J, Ludwig W, Létang J-M (2001) On the application of X-ray microtomography in the field of materials science. Adv Eng Mat 3(8):539–546CrossRef Maire E, Buffière J-Y, Salvo L, Blandin J-J, Ludwig W, Létang J-M (2001) On the application of X-ray microtomography in the field of materials science. Adv Eng Mat 3(8):539–546CrossRef
3.
Zurück zum Zitat Bernard D (ed) (2008) 1st conference on 3D-imaging of materials and systems 2008. ICMCB, Bordeaux Bernard D (ed) (2008) 1st conference on 3D-imaging of materials and systems 2008. ICMCB, Bordeaux
4.
Zurück zum Zitat Stock SR (2008) MicroComputed tomography: methodology and applications. CRC Stock SR (2008) MicroComputed tomography: methodology and applications. CRC
5.
Zurück zum Zitat Stock SR (2008) Recent advances in X-ray microtomography applied to materials. Int Mater Rev 53(3):129–181CrossRef Stock SR (2008) Recent advances in X-ray microtomography applied to materials. Int Mater Rev 53(3):129–181CrossRef
6.
Zurück zum Zitat Banhart J (2008) Advanced tomographic methods in materials research and engineering. Oxford University Press Banhart J (2008) Advanced tomographic methods in materials research and engineering. Oxford University Press
7.
Zurück zum Zitat Bart-Smith H, Bastawros A-F, Mumm DR, Evans AG, Sypeck DJ, Wadley HNG (1998) Compressive deformation and yielding mechanisms in cellular Al alloys determined using X-ray tomography and surface strain mapping. Acta Mater 46(10):3583–3592CrossRef Bart-Smith H, Bastawros A-F, Mumm DR, Evans AG, Sypeck DJ, Wadley HNG (1998) Compressive deformation and yielding mechanisms in cellular Al alloys determined using X-ray tomography and surface strain mapping. Acta Mater 46(10):3583–3592CrossRef
8.
Zurück zum Zitat Babout L, Maire E, Buffière J-Y, Fougères R (2001) Characterisation by X-ray computed tomography of decohesion, porosity growth and coalescence in model metal matrix composites. Acta Mater 49(11):2055–2063CrossRef Babout L, Maire E, Buffière J-Y, Fougères R (2001) Characterisation by X-ray computed tomography of decohesion, porosity growth and coalescence in model metal matrix composites. Acta Mater 49(11):2055–2063CrossRef
9.
Zurück zum Zitat Bontaz-Carion J, Pellegrini Y-P (2006) X-ray microtomography analysis of dynamic damage in tantalum. Adv Eng Mater 8(6):480–486CrossRef Bontaz-Carion J, Pellegrini Y-P (2006) X-ray microtomography analysis of dynamic damage in tantalum. Adv Eng Mater 8(6):480–486CrossRef
10.
Zurück zum Zitat Schilling PJ, Karedla BR, Tatiparthi AK, Verges MA, Herrington PD (2005) X-ray computed microtomography of internal damage in fiber reinforced polymer matrix composites. Compos Sci Tech 65(14):2071–2078CrossRef Schilling PJ, Karedla BR, Tatiparthi AK, Verges MA, Herrington PD (2005) X-ray computed microtomography of internal damage in fiber reinforced polymer matrix composites. Compos Sci Tech 65(14):2071–2078CrossRef
11.
Zurück zum Zitat Sinclair R, Preuss M, Maire E, Buffiere J-Y, Bowen P, Withers PJ (2004) The effect of fibre fractures in the bridging zone of fatigue cracked Ti6Al4V/SiC fibre composites. Acta Mater 52(6):1423–1438CrossRef Sinclair R, Preuss M, Maire E, Buffiere J-Y, Bowen P, Withers PJ (2004) The effect of fibre fractures in the bridging zone of fatigue cracked Ti6Al4V/SiC fibre composites. Acta Mater 52(6):1423–1438CrossRef
12.
Zurück zum Zitat Ferrié E, Buffiere J-Y, Ludwig W, Gravouil A, Edwards L (2006) Fatigue crack propagation: in situ visualization using X-ray microtomography and 3D simulation using the extended finite element method. Acta Mater 5(4):1111–1122CrossRef Ferrié E, Buffiere J-Y, Ludwig W, Gravouil A, Edwards L (2006) Fatigue crack propagation: in situ visualization using X-ray microtomography and 3D simulation using the extended finite element method. Acta Mater 5(4):1111–1122CrossRef
13.
Zurück zum Zitat Wolfsdorf TL, Bender WH, Voorhees PW (1997) The morphology of high volume fraction solid-liquid mixtures: an application of microstructural tomography. Acta Mater 45(6):2279–2295CrossRef Wolfsdorf TL, Bender WH, Voorhees PW (1997) The morphology of high volume fraction solid-liquid mixtures: an application of microstructural tomography. Acta Mater 45(6):2279–2295CrossRef
14.
Zurück zum Zitat Ludwig O, Dimichiel M, Salvo L, Suéry M, Falus P (2005) In-situ three-dimensional microstructural investigation of solidification of an Al-Cu Alloy by ultrafast X-ray microtomography. Metall Mater Trans A 36(6):1515–1523CrossRef Ludwig O, Dimichiel M, Salvo L, Suéry M, Falus P (2005) In-situ three-dimensional microstructural investigation of solidification of an Al-Cu Alloy by ultrafast X-ray microtomography. Metall Mater Trans A 36(6):1515–1523CrossRef
15.
Zurück zum Zitat Maire E, Colombo P, Adrien J, Babout L, Biasetto L (2007) Characterization of the morphology of cellular ceramics by 3D image processing of X-ray tomography. J Eur Ceram Soc 27:1973–1981CrossRef Maire E, Colombo P, Adrien J, Babout L, Biasetto L (2007) Characterization of the morphology of cellular ceramics by 3D image processing of X-ray tomography. J Eur Ceram Soc 27:1973–1981CrossRef
16.
Zurück zum Zitat Viot P, Bernard D (2006) Impact test deformations of polypropylene foam samples followed by microtomography. J Mater Sci 41:1277–1279CrossRef Viot P, Bernard D (2006) Impact test deformations of polypropylene foam samples followed by microtomography. J Mater Sci 41:1277–1279CrossRef
17.
Zurück zum Zitat Ludwig W, Buffière J-Y, Savelli S, Cloetens P (2003) Study of the interaction of a short fatigue crack with grain boundaries in a cast Al alloy using X-ray microtomography. Acta Mater 51(3):585–598CrossRef Ludwig W, Buffière J-Y, Savelli S, Cloetens P (2003) Study of the interaction of a short fatigue crack with grain boundaries in a cast Al alloy using X-ray microtomography. Acta Mater 51(3):585–598CrossRef
18.
Zurück zum Zitat Youssef S, Maire E, Gaertner R (2005) Finite element modelling of the actual structure of cellular materials determined by X-ray tomography. Acta Mater 53(3):719–730CrossRef Youssef S, Maire E, Gaertner R (2005) Finite element modelling of the actual structure of cellular materials determined by X-ray tomography. Acta Mater 53(3):719–730CrossRef
19.
Zurück zum Zitat Maire E, Fazekas A, Salvo L, Dendievel R, Youssef S, Cloetens P, Letang JM (2003) X-ray tomography applied to the characterization of cellular materials. Related finite element modeling problems. Compos Sci Technol 63(16):2431–2443CrossRef Maire E, Fazekas A, Salvo L, Dendievel R, Youssef S, Cloetens P, Letang JM (2003) X-ray tomography applied to the characterization of cellular materials. Related finite element modeling problems. Compos Sci Technol 63(16):2431–2443CrossRef
20.
Zurück zum Zitat Nielsen SF, Poulsen HF, Beckmann F, Thorning C, Wert JA (2003) Measurements of plastic displacement gradient components in three dimensions using marker particles and synchrotron X-ray absorption microtomography. Acta Mater 51(8):2407–2415CrossRef Nielsen SF, Poulsen HF, Beckmann F, Thorning C, Wert JA (2003) Measurements of plastic displacement gradient components in three dimensions using marker particles and synchrotron X-ray absorption microtomography. Acta Mater 51(8):2407–2415CrossRef
21.
Zurück zum Zitat Toda H, Sinclair I, Buffière J-Y, Maire E, Connolley T, Joyce M, Khor KH, Gregson P (2003) Assessment of the fatigue crack closure phenomenon in damage-tolerant aluminium alloy by in-situ high-resolution synchrotron X-ray microtomography. Philos Mag 83(21):2429–2448CrossRef Toda H, Sinclair I, Buffière J-Y, Maire E, Connolley T, Joyce M, Khor KH, Gregson P (2003) Assessment of the fatigue crack closure phenomenon in damage-tolerant aluminium alloy by in-situ high-resolution synchrotron X-ray microtomography. Philos Mag 83(21):2429–2448CrossRef
22.
Zurück zum Zitat Withers PJ, Bennett J, Hung Y-C, Preuss M (2006) Crack opening displacements during fatigue crack growth in Ti-SiC fibre metal matrix composites by X-ray tomography. Mater Sci Technol 22(9):1052–1058CrossRef Withers PJ, Bennett J, Hung Y-C, Preuss M (2006) Crack opening displacements during fatigue crack growth in Ti-SiC fibre metal matrix composites by X-ray tomography. Mater Sci Technol 22(9):1052–1058CrossRef
23.
Zurück zum Zitat Bay BK, Smith TS, Fyhrie DP, Saad M (1999) Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp Mech 39:217–226CrossRef Bay BK, Smith TS, Fyhrie DP, Saad M (1999) Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp Mech 39:217–226CrossRef
24.
Zurück zum Zitat Bornert M, Chaix J-M, Doumalin P, Dupré J-C, Fournel T, Jeulin D, Maire E, Moreaud M, Moulinec H (2004) Mesure tridimensionnelle de champs cinématiques par imagerie volumique pour l’analyse des matériaux et des structures. Inst Mes Métrol 4:43–88 Bornert M, Chaix J-M, Doumalin P, Dupré J-C, Fournel T, Jeulin D, Maire E, Moreaud M, Moulinec H (2004) Mesure tridimensionnelle de champs cinématiques par imagerie volumique pour l’analyse des matériaux et des structures. Inst Mes Métrol 4:43–88
25.
Zurück zum Zitat McKinley TO, Bay BK (2003) Trabecular bone strain changes associated with subchondral stiffening of the proximal tibia. J Biomech 36(2):155–163CrossRef McKinley TO, Bay BK (2003) Trabecular bone strain changes associated with subchondral stiffening of the proximal tibia. J Biomech 36(2):155–163CrossRef
26.
Zurück zum Zitat Roux S, Hild F, Viot P, Bernard D (2008) Three dimensional image correlation from X-ray computed tomography of solid foam. Compos Part A 39(8):1253–1265CrossRef Roux S, Hild F, Viot P, Bernard D (2008) Three dimensional image correlation from X-ray computed tomography of solid foam. Compos Part A 39(8):1253–1265CrossRef
27.
Zurück zum Zitat Réthoré J, Tinnes J-P, Roux S, Buffière J-Y, Hild F (2008) Extended three-dimensional digital image correlation (X3D-DIC). C R Méc 336:643–649MATH Réthoré J, Tinnes J-P, Roux S, Buffière J-Y, Hild F (2008) Extended three-dimensional digital image correlation (X3D-DIC). C R Méc 336:643–649MATH
28.
Zurück zum Zitat Hild F, Maire E, Roux S, Witz J-F (2009) Three dimensional analysis of a compression test on stone wool. Acta Mater 57:3310–3320CrossRef Hild F, Maire E, Roux S, Witz J-F (2009) Three dimensional analysis of a compression test on stone wool. Acta Mater 57:3310–3320CrossRef
29.
Zurück zum Zitat Limodin N, Réthoré J, Buffière J-Y, Gravouil A, Hild F, Roux S (2009) Crack closure and stress intensity factor measurements in nodular graphite cast iron using 3D correlation of laboratory X ray microtomography images. Acta Mater 57(14):4090–4101CrossRef Limodin N, Réthoré J, Buffière J-Y, Gravouil A, Hild F, Roux S (2009) Crack closure and stress intensity factor measurements in nodular graphite cast iron using 3D correlation of laboratory X ray microtomography images. Acta Mater 57(14):4090–4101CrossRef
30.
Zurück zum Zitat Limodin N, Réthoré J, Buffière J-Y, Hild F, Roux S, Ludwig W, Rannou J, Gravouil A (2010) Influence of closure on the 3D propagation of fatigue cracks in a nodular cast iron investigated by X-ray tomography and 3D volume correlation. Acta Mater 58:2957–2967CrossRef Limodin N, Réthoré J, Buffière J-Y, Hild F, Roux S, Ludwig W, Rannou J, Gravouil A (2010) Influence of closure on the 3D propagation of fatigue cracks in a nodular cast iron investigated by X-ray tomography and 3D volume correlation. Acta Mater 58:2957–2967CrossRef
31.
Zurück zum Zitat Rannou J, Limodin N, Réthoré J, Gravouil A, Ludwig W, Baïetto-Dubourg M-C, Buffière J-Y, Combescure A, Hild F, Roux S (2010) Three dimensional experimental and numerical multiscale analysis of a fatigue crack. Comput Methods Appl Mech Eng 199:1307–1325CrossRef Rannou J, Limodin N, Réthoré J, Gravouil A, Ludwig W, Baïetto-Dubourg M-C, Buffière J-Y, Combescure A, Hild F, Roux S (2010) Three dimensional experimental and numerical multiscale analysis of a fatigue crack. Comput Methods Appl Mech Eng 199:1307–1325CrossRef
32.
Zurück zum Zitat Bergonnier S, Hild F, Roux S (2005) Digital image correlation used for mechanical tests on crimped glass wool samples. J Strain Anal 40(2):185–197CrossRef Bergonnier S, Hild F, Roux S (2005) Digital image correlation used for mechanical tests on crimped glass wool samples. J Strain Anal 40(2):185–197CrossRef
33.
Zurück zum Zitat Besnard G, Hild F, Roux S (2006) “Finite-element” displacement fields analysis from digital images: application to Portevin-Le Chatelier bands. Exp Mech 46:789–803CrossRef Besnard G, Hild F, Roux S (2006) “Finite-element” displacement fields analysis from digital images: application to Portevin-Le Chatelier bands. Exp Mech 46:789–803CrossRef
34.
Zurück zum Zitat Bornert M, Brémand F, Doumalin P, Dupré J-C, Fazzini M, Grédiac M, Hild F, Mistou S, Molimard J, Orteu J-J, Robert L, Surrel Y, Vacher P, Wattrisse B (2009) Assessment of digital image correlation measurement errors: methodology and results. Exp Mech 49(3):353–370CrossRef Bornert M, Brémand F, Doumalin P, Dupré J-C, Fazzini M, Grédiac M, Hild F, Mistou S, Molimard J, Orteu J-J, Robert L, Surrel Y, Vacher P, Wattrisse B (2009) Assessment of digital image correlation measurement errors: methodology and results. Exp Mech 49(3):353–370CrossRef
35.
Zurück zum Zitat Réthoré J, Hild F, Roux S (2007) Shear-band capturing using a multiscale extended digital image correlation technique. Comput Methods Appl Mech Eng 196(49–52):5016–5030CrossRefMATH Réthoré J, Hild F, Roux S (2007) Shear-band capturing using a multiscale extended digital image correlation technique. Comput Methods Appl Mech Eng 196(49–52):5016–5030CrossRefMATH
36.
Zurück zum Zitat Réthoré J, Hild F, Roux S (2008) Extended digital image correlation with crack shape optimization. Int J Numer Methods Eng 73(2):248–272CrossRefMATH Réthoré J, Hild F, Roux S (2008) Extended digital image correlation with crack shape optimization. Int J Numer Methods Eng 73(2):248–272CrossRefMATH
37.
Zurück zum Zitat Davis GR, Elliot JC (2006) Artefacts in X-ray microtomography of materials. Mater Sci Eng 22(9):1011–1018 Davis GR, Elliot JC (2006) Artefacts in X-ray microtomography of materials. Mater Sci Eng 22(9):1011–1018
38.
Zurück zum Zitat Ketcham RA (2006) New algorithms for ring artefact removal. In: Bonse U (ed) Developments in X-ray tomography V. SPIE, Bellingham, 00-1-15 Ketcham RA (2006) New algorithms for ring artefact removal. In: Bonse U (ed) Developments in X-ray tomography V. SPIE, Bellingham, 00-1-15
39.
Zurück zum Zitat Roux S, Hild F (2008) Digital image mechanical identification (DIMI). Exp Mech 48(4):495–508CrossRef Roux S, Hild F (2008) Digital image mechanical identification (DIMI). Exp Mech 48(4):495–508CrossRef
40.
Zurück zum Zitat Leclerc H, Périé J-N, Roux S, Hild F (2009) Integrated digital image correlation for the identification of mechanical Properties. In: Gagalowicz A, Philips W (eds) MIRAGE 2009. LNCS, vol 5496. Springer, Berlin, pp 161–171 Leclerc H, Périé J-N, Roux S, Hild F (2009) Integrated digital image correlation for the identification of mechanical Properties. In: Gagalowicz A, Philips W (eds) MIRAGE 2009. LNCS, vol 5496. Springer, Berlin, pp 161–171
41.
Zurück zum Zitat Réthoré J, Roux S, Hild F (2009) An extended and integrated digital image correlation technique applied to the analysis fractured samples. Eur J Comput Mech 18:285–306 Réthoré J, Roux S, Hild F (2009) An extended and integrated digital image correlation technique applied to the analysis fractured samples. Eur J Comput Mech 18:285–306
42.
Zurück zum Zitat Claire D, Hild F, Roux S (2004) A finite element formulation to identify damage fields: the equilibrium gap method. Int J Numer Methods Eng 61(2):189–208CrossRefMATH Claire D, Hild F, Roux S (2004) A finite element formulation to identify damage fields: the equilibrium gap method. Int J Numer Methods Eng 61(2):189–208CrossRefMATH
43.
Zurück zum Zitat Roux S, Hild F (2006) Stress intensity factor measurements from digital image correlation: post-processing and integrated approaches. Int J Fract 140(1–4):141–157CrossRefMATH Roux S, Hild F (2006) Stress intensity factor measurements from digital image correlation: post-processing and integrated approaches. Int J Fract 140(1–4):141–157CrossRefMATH
44.
Zurück zum Zitat Roux S, Hild F (2006) From image analysis to damage constitutive law identification. NDT.net 11(12), roux.pdf Roux S, Hild F (2006) From image analysis to damage constitutive law identification. NDT.net 11(12), roux.pdf
45.
Zurück zum Zitat Labiche J-C, Mathon O, Pascarelli S, Newton MA, Guilera Ferre G, Curfs C, Vaughan G, Homs A, Carreiras DF (2007) The fast readout low noise camera as a versatile X-ray detector for time resolved dispersive extended X-ray absorption fine structure and diffraction studies of dynamic problems in materials science, chemistry and catalysis. Rev Sci Instrum 78:091301CrossRef Labiche J-C, Mathon O, Pascarelli S, Newton MA, Guilera Ferre G, Curfs C, Vaughan G, Homs A, Carreiras DF (2007) The fast readout low noise camera as a versatile X-ray detector for time resolved dispersive extended X-ray absorption fine structure and diffraction studies of dynamic problems in materials science, chemistry and catalysis. Rev Sci Instrum 78:091301CrossRef
46.
Zurück zum Zitat Buffière J-Y, Ferrié E, Proudhon H, Ludwig W (2006) Three-dimensional visualisation of fatigue cracks in metals using high resolution synchrotron X-ray micro-tomography. Mater Sci Technol 22(9):1019–1024CrossRef Buffière J-Y, Ferrié E, Proudhon H, Ludwig W (2006) Three-dimensional visualisation of fatigue cracks in metals using high resolution synchrotron X-ray micro-tomography. Mater Sci Technol 22(9):1019–1024CrossRef
47.
Zurück zum Zitat Kak AC, Slaney M (2001) Principles of computerized tomographic imaging. Society of Industrial and Applied Mathematics Kak AC, Slaney M (2001) Principles of computerized tomographic imaging. Society of Industrial and Applied Mathematics
Metadaten
Titel
Voxel-Scale Digital Volume Correlation
verfasst von
H. Leclerc
J.-N. Périé
S. Roux
F. Hild
Publikationsdatum
01.04.2011
Verlag
Springer US
Erschienen in
Experimental Mechanics / Ausgabe 4/2011
Print ISSN: 0014-4851
Elektronische ISSN: 1741-2765
DOI
https://doi.org/10.1007/s11340-010-9407-6

Weitere Artikel der Ausgabe 4/2011

Experimental Mechanics 4/2011 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.