Skip to main content
Erschienen in: Microsystem Technologies 6/2008

01.06.2008 | Technical Paper

A directly stackable microsystem onto the cultured cells for cytotoxicity tests

verfasst von: Hyunwoo Bang, Won Gu Lee, Hoyoung Yun, Chanil Chung, Jun Keun Chang, Dong-Chul Han

Erschienen in: Microsystem Technologies | Ausgabe 6/2008

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Today’s pharmaceutical industry is facing several challenges resulting from a vastly increasing number of samples through a high-throughput screening. In addition, the increased demand for cytotoxicity tests have caused bottlenecks, which in turn is causing serious problems. Here we present a novel approach to performing the cytotoxicity test. This new method uses a directly stackable microsystem on the cultured cells. It also enables us to perform cytotoxicity tests with more reliability by providing exactly the same cell-culture environment for all experiments. The new approach consists of two fascinating modules: First, a serial dilution module can linearly dilute one drug solution into several diluted ones in a serial manner, and equally distribute them into independent microchambers. Secondly, a microcompartment module can firmly attach itself onto any cultured cells and divide the directly-covered cell surface into multiple well-type microchambers instantaneously. This microsystem has a strong feasible advantage. It hardly needs to modify the established cell culture protocols, and at the same time it can eliminate some repetitive and laborious processes. A quick flexible integrated microsystem would reduce many redundant efforts during on-chip cytotoxicity tests.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Bang H, Lim SH, Lee YK, Chung S, Chung C, Han D-C, Chang JK (2004) Serial dilution microchip for cytotoxicity test. J Micromech Microeng 14:1165–1170CrossRef Bang H, Lim SH, Lee YK, Chung S, Chung C, Han D-C, Chang JK (2004) Serial dilution microchip for cytotoxicity test. J Micromech Microeng 14:1165–1170CrossRef
Zurück zum Zitat Bang H, Lee WG, Park J, Yun H, Lee J, Chung S, Cho K, Chung C, Han D-C, Chang JK (2006) Active sealing for soft polymer microchips: method and practical applications. J Micromech Microeng 16:708–714CrossRef Bang H, Lee WG, Park J, Yun H, Lee J, Chung S, Cho K, Chung C, Han D-C, Chang JK (2006) Active sealing for soft polymer microchips: method and practical applications. J Micromech Microeng 16:708–714CrossRef
Zurück zum Zitat Cantin AM, North SL, Fells GA, Hubbard RC, Crystal RG (1987) Oxidant-mediated epithelial cell injury in idiopathic pulmonary fibrosis. J Clin Invest 79:1665–1673CrossRef Cantin AM, North SL, Fells GA, Hubbard RC, Crystal RG (1987) Oxidant-mediated epithelial cell injury in idiopathic pulmonary fibrosis. J Clin Invest 79:1665–1673CrossRef
Zurück zum Zitat Chang JK, Heo YS, Bang H, Cho K, Chung S, Chung C, Han D-C (2003a) Functional integration of serial dilution and capillary electrophoresis on a PDMS microchip. Biotech Bioprocess Eng 8:33–239 Chang JK, Heo YS, Bang H, Cho K, Chung S, Chung C, Han D-C (2003a) Functional integration of serial dilution and capillary electrophoresis on a PDMS microchip. Biotech Bioprocess Eng 8:33–239
Zurück zum Zitat Chang JK, Bang H, Park S-J, Chung S, Chung C, Han D-C (2003b) Fabrication of the PDMS microchip for serially diluting sample with buffer. Microsyst Technol 9:555–558CrossRef Chang JK, Bang H, Park S-J, Chung S, Chung C, Han D-C (2003b) Fabrication of the PDMS microchip for serially diluting sample with buffer. Microsyst Technol 9:555–558CrossRef
Zurück zum Zitat Chen CS, Mrksich M, Huang S, Whitesides GM, Ingber DE (1997) Geometric control of cell life and death. Science 276:1425–1428CrossRef Chen CS, Mrksich M, Huang S, Whitesides GM, Ingber DE (1997) Geometric control of cell life and death. Science 276:1425–1428CrossRef
Zurück zum Zitat Dittrich PS, Schwille P (2003) An integrated microfluidic system for reaction, high-sensitivity detection, and sorting of fluorescent cells and particles. Anal Chem 75:5767–5774CrossRef Dittrich PS, Schwille P (2003) An integrated microfluidic system for reaction, high-sensitivity detection, and sorting of fluorescent cells and particles. Anal Chem 75:5767–5774CrossRef
Zurück zum Zitat Freshney I (2001) Application of cell cultures to toxicology. Cell Biol Toxicol 17:213–230CrossRef Freshney I (2001) Application of cell cultures to toxicology. Cell Biol Toxicol 17:213–230CrossRef
Zurück zum Zitat Jeon NL, Dertinger SKW, Chiu DT, Choi IS, Stroock AD, Whitesides GM (2000) Generation of solution and surface gradients using microfluidic systems. Langmuir 16:8311–8316CrossRef Jeon NL, Dertinger SKW, Chiu DT, Choi IS, Stroock AD, Whitesides GM (2000) Generation of solution and surface gradients using microfluidic systems. Langmuir 16:8311–8316CrossRef
Zurück zum Zitat Ng MKJ, Gitlin I, Strook AD, Whitesides GM (2002) Components for integrated poly (dimethylsiloxane) microfluidic systems. Electrophoresis 23:3461–3473CrossRef Ng MKJ, Gitlin I, Strook AD, Whitesides GM (2002) Components for integrated poly (dimethylsiloxane) microfluidic systems. Electrophoresis 23:3461–3473CrossRef
Zurück zum Zitat Slater K (2001) Cytotoxicity tests for high-throughput drug discovery. Curr Opin Biotechnol 12:70–74CrossRef Slater K (2001) Cytotoxicity tests for high-throughput drug discovery. Curr Opin Biotechnol 12:70–74CrossRef
Zurück zum Zitat Suttorp N, Simon LM (1982) Lung cell oxidant injury: enhancement of polymorphonuclear leukocyte-mediated cytotoxicity in lung cells exposed to sustained in vitro hyperoxia. J Clin Invest 70:342–350CrossRef Suttorp N, Simon LM (1982) Lung cell oxidant injury: enhancement of polymorphonuclear leukocyte-mediated cytotoxicity in lung cells exposed to sustained in vitro hyperoxia. J Clin Invest 70:342–350CrossRef
Zurück zum Zitat Thomas CH, Lhoest JB, Castner DG, McFarland CD, Healy KE (1999) Surfaces designed to control the projected area and shape of individual cells. J Biomech Eng 121:40–48CrossRef Thomas CH, Lhoest JB, Castner DG, McFarland CD, Healy KE (1999) Surfaces designed to control the projected area and shape of individual cells. J Biomech Eng 121:40–48CrossRef
Zurück zum Zitat Weiss SJ, Young J, Lobuglio AF, Slivka A, Nimeh NF (1981) Role of hydrogen peroxide in neutrophil-mediated destruction of cultured endothelial cells. J Clin Invest 68:714–721CrossRef Weiss SJ, Young J, Lobuglio AF, Slivka A, Nimeh NF (1981) Role of hydrogen peroxide in neutrophil-mediated destruction of cultured endothelial cells. J Clin Invest 68:714–721CrossRef
Zurück zum Zitat Xia Y, Whitesides GM (1998) Soft Lithography. Annu Rev Mater Sci 28:153–184CrossRef Xia Y, Whitesides GM (1998) Soft Lithography. Annu Rev Mater Sci 28:153–184CrossRef
Metadaten
Titel
A directly stackable microsystem onto the cultured cells for cytotoxicity tests
verfasst von
Hyunwoo Bang
Won Gu Lee
Hoyoung Yun
Chanil Chung
Jun Keun Chang
Dong-Chul Han
Publikationsdatum
01.06.2008
Verlag
Springer-Verlag
Erschienen in
Microsystem Technologies / Ausgabe 6/2008
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-007-0518-7

Weitere Artikel der Ausgabe 6/2008

Microsystem Technologies 6/2008 Zur Ausgabe

Neuer Inhalt