Abstract

A new portable blood flow volume (BFV) sensor is developed from the function of estimating oxygen saturation (SpO2) implemented inherently to maximize the accuracy of predicting BFV. The sensor is designed to estimate BFV in high accuracy at the arteriovenous fistula (AVF) of a hemodialysis (HD) patient based on a built artificial neural network (ANN). The BFVs measured by the proposed sensor would help greatly evaluate the AVF complications at early stage, such as infection, bleeding, stenosis, and vascular calcification, while AVFs are under long-time usage. The sensor module consists of LEDs/PDs, readout circuitry and algorithm to estimate BFV. The oxygen saturation (SpO2) is also estimated using the same hardware to serve as one of input features for the aforementioned ANN for maximize the accuracy in BFV. With using the hardware, oxygen saturation’s algorithm is built and implemented with the mean deviation (MD) and standard deviation (SD) adapted FDA standard, which is MD ∓ 1.96SD = 0.024% ∓ 1.772% < 5%. Besides, the BFV ground-truth data are obtained from a transonic HD03 dilution machine for calibrating the ANN. The accuracy in estimating BFV with and without estimating SpO2 are compared, which correspond to R2 = 0. 94,517, root mean square error = 92.199 ml/min and R2 = 0.87145, root mean square error = 141.015 ml/min, respectively. Besides, another neural network model is implemented with fixing value of an input feature of SpO2, the ANN model’s correlation reaches only 0.1554, while the related root mean square error is 493.2442 ml/min. Therefore, the results validate clearly the necessity of the inherent estimation on SpO2.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Bessems D, Rutten M, Vsse FVD (2007) A wave propagation model of blood flow in large vessels using an approximate velocity profile function. J Fluid Mech 580:145–168 Bessems D, Rutten M, Vsse FVD (2007) A wave propagation model of blood flow in large vessels using an approximate velocity profile function. J Fluid Mech 580:145–168
Zurück zum Zitat Cai B, Jiang X (2014) A novel artificial neural network method for biomedical prediction based on matrix pseudo-inversion. J Biomed Inform 48:114–121CrossRef Cai B, Jiang X (2014) A novel artificial neural network method for biomedical prediction based on matrix pseudo-inversion. J Biomed Inform 48:114–121CrossRef
Zurück zum Zitat Chiang PY, Chao PC-P, Tarng DC, Yang CY (2017) A novel wireless photoplethysmography blood flow volume sensor for assessing arteriovenous fistula of hemodialysis patients. IEEE Trans Ind Electron 64:9626–9635CrossRef Chiang PY, Chao PC-P, Tarng DC, Yang CY (2017) A novel wireless photoplethysmography blood flow volume sensor for assessing arteriovenous fistula of hemodialysis patients. IEEE Trans Ind Electron 64:9626–9635CrossRef
Zurück zum Zitat da Silva FAM, Kruger MAV, de Pereira WCA (2014) Continuous flow phantom for the calibration of an ultrasonic transit-time flowmeter. Res Biomed Eng 30:03–10 da Silva FAM, Kruger MAV, de Pereira WCA (2014) Continuous flow phantom for the calibration of an ultrasonic transit-time flowmeter. Res Biomed Eng 30:03–10
Zurück zum Zitat Ingle JD, Crouch SR (1988) Spectrochemical analysis. Prentice Hall, Englewood Cliffs Ingle JD, Crouch SR (1988) Spectrochemical analysis. Prentice Hall, Englewood Cliffs
Zurück zum Zitat Kao YH, Chao PCP, Wey CL (2018) Towards maximizing the sensing accuracy of an cuffless, optical blood pressure sensor using a high-order front-end filter. Microsyst Technol 24:4621–4622CrossRef Kao YH, Chao PCP, Wey CL (2018) Towards maximizing the sensing accuracy of an cuffless, optical blood pressure sensor using a high-order front-end filter. Microsyst Technol 24:4621–4622CrossRef
Zurück zum Zitat Krivitski NM (1995) Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int 48:244–250CrossRef Krivitski NM (1995) Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int 48:244–250CrossRef
Zurück zum Zitat Lee C, Shin HS, Lee M (2011) Relations between ac–dc components and optical path length in photoplethysmography. J Biomed Opt 16:1–10 Lee C, Shin HS, Lee M (2011) Relations between ac–dc components and optical path length in photoplethysmography. J Biomed Opt 16:1–10
Zurück zum Zitat Mukherjee R, Dubey S, Gupta B, Chakravarty T (2016) Bio-optical modeling of human skin to eliminate the skin structure variability in blood pressure measurement. In: Conference on IEEE advances in electrical, electronics, information, communication and bio-informatics (AEEICB), pp 450–454 Mukherjee R, Dubey S, Gupta B, Chakravarty T (2016) Bio-optical modeling of human skin to eliminate the skin structure variability in blood pressure measurement. In: Conference on IEEE advances in electrical, electronics, information, communication and bio-informatics (AEEICB), pp 450–454
Zurück zum Zitat Näslund J, Pettersson J, Lundeberg T, Linnarsson D, Lindberg L-G (2006) Non-invasive continuous estimation of blood flow changes in human patellar bone. Med Biol Eng Comput 44:501–509CrossRef Näslund J, Pettersson J, Lundeberg T, Linnarsson D, Lindberg L-G (2006) Non-invasive continuous estimation of blood flow changes in human patellar bone. Med Biol Eng Comput 44:501–509CrossRef
Zurück zum Zitat National Kidney Foundation (2006) KDOQI clinical practice guidelines and clinical practice recommendations for 2006 updates: hemodialysis adequacy peritoneal dialysis adequacy and vascular access. Am J Kidney Dis 48(suppl 1):S1–S322 National Kidney Foundation (2006) KDOQI clinical practice guidelines and clinical practice recommendations for 2006 updates: hemodialysis adequacy peritoneal dialysis adequacy and vascular access. Am J Kidney Dis 48(suppl 1):S1–S322
Zurück zum Zitat Orozco L (2013) Programmable-gain transimpedance amplifiers maximize dynamic range in spectroscopy systems. Analog Dialogue 47:1–5 Orozco L (2013) Programmable-gain transimpedance amplifiers maximize dynamic range in spectroscopy systems. Analog Dialogue 47:1–5
Zurück zum Zitat Reisner A, Shaltis PA, McCombie D, Asada HH (2008) Utility of the photoplethysmogram in circulatory monitoring. Anesthesiology 108:950–958CrossRef Reisner A, Shaltis PA, McCombie D, Asada HH (2008) Utility of the photoplethysmogram in circulatory monitoring. Anesthesiology 108:950–958CrossRef
Zurück zum Zitat Rybynok VO, Kyriacou PA (2010) Beer–Lambert law along non-linear mean light pathways for the rational analysis of photoplethysmography. J Phys Conf Ser 238(1): 012061 Rybynok VO, Kyriacou PA (2010) Beer–Lambert law along non-linear mean light pathways for the rational analysis of photoplethysmography. J Phys Conf Ser 238(1): 012061
Zurück zum Zitat Sallomi AH, Ahmed S (2016) Multi-layer feed forward neural network application in adaptive beamforming of smart antenna system. In: 2016 Al-Sadeq international conference on multidisciplinary in IT and communication science and applications (AIC-MITCSA). IEEE Sallomi AH, Ahmed S (2016) Multi-layer feed forward neural network application in adaptive beamforming of smart antenna system. In: 2016 Al-Sadeq international conference on multidisciplinary in IT and communication science and applications (AIC-MITCSA). IEEE
Zurück zum Zitat Tamura T, Maeda Y, Sekine M, Yoshida M (2014) Wearable photoplethysmographic sensors—past and present. Electronics 3:282–302CrossRef Tamura T, Maeda Y, Sekine M, Yoshida M (2014) Wearable photoplethysmographic sensors—past and present. Electronics 3:282–302CrossRef
Zurück zum Zitat Teng XF, Zhang YT (2004) The effect of contacting force on photoplethysmographic signals. Physiol Meas 25:1323–1335CrossRef Teng XF, Zhang YT (2004) The effect of contacting force on photoplethysmographic signals. Physiol Meas 25:1323–1335CrossRef
Zurück zum Zitat Tessitore N, Bedogna V, Gammaro L, Lipari G, Poli A, Baggio E, Firpo M, Morana G, Mansueto G, Maschio G (2003) Diagnostic accuracy of ultrasound dilution access blood flow measurement in detecting stenosis and predicting thrombosis in native forearm arteriovenous fistulae for hemodialysis. Am J Kidney Dis 42:331–341CrossRef Tessitore N, Bedogna V, Gammaro L, Lipari G, Poli A, Baggio E, Firpo M, Morana G, Mansueto G, Maschio G (2003) Diagnostic accuracy of ultrasound dilution access blood flow measurement in detecting stenosis and predicting thrombosis in native forearm arteriovenous fistulae for hemodialysis. Am J Kidney Dis 42:331–341CrossRef
Zurück zum Zitat Venketesu K (2015) Blood flow analysis using ultrasound doppler technique. IOSR J Electron Commun Eng 10:31–35 Venketesu K (2015) Blood flow analysis using ultrasound doppler technique. IOSR J Electron Commun Eng 10:31–35
Zurück zum Zitat Whittier WL (2009) Surveillance of hemodialysis vascular access. Semin Intervent Radiol 26:130–138CrossRef Whittier WL (2009) Surveillance of hemodialysis vascular access. Semin Intervent Radiol 26:130–138CrossRef
Zurück zum Zitat Wilhelm K-P, Elsner P, Berardesca E, Maibach HI (2006) Bioengineering of the skin: skin imaging and analysis. CRC Press, Boca RatonCrossRef Wilhelm K-P, Elsner P, Berardesca E, Maibach HI (2006) Bioengineering of the skin: skin imaging and analysis. CRC Press, Boca RatonCrossRef
Zurück zum Zitat Zeraati A, Mousavi SSB, Mousavi MB (2013) A review article: access recirculation among end stage renal disease patients undergoing maintenance hemodialysis. Nephro-Urol Mon 5:728–732CrossRef Zeraati A, Mousavi SSB, Mousavi MB (2013) A review article: access recirculation among end stage renal disease patients undergoing maintenance hemodialysis. Nephro-Urol Mon 5:728–732CrossRef
Metadaten
Titel
A new blood flow volume sensor with embedded estimation of SpO2 to maximize its accuracy
verfasst von
Duc Huy Nguyen
Yu-Ting Chen
Tse-Yi Tu
Paul C.-P. Chao
Yu-Wei Fang
Bing Shi Lin
Publikationsdatum
11.01.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
Microsystem Technologies / Ausgabe 6/2021
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-020-05149-1

Weitere Artikel der Ausgabe 6/2021

Microsystem Technologies 6/2021 Zur Ausgabe

Neuer Inhalt