Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 9/2007

01.09.2007 | Original Article

A procedure to simulate coronary artery bypass graft surgery

verfasst von: Fernando Cacho, Manuel Doblaré, Gerhard A. Holzapfel

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 9/2007

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In coronary artery bypass graft (CABG) surgery the involved tissues are overstretched, which may lead to intimal hyperplasia and graft failure. We propose a computational methodology for the simulation of traditional CABG surgery, and analyze the effect of two clinically relevant parameters on the artery and graft responses, i.e., incision length and insertion angle for a given graft diameter. The computational structural analyses are based on actual three-dimensional vessel dimensions of a human coronary artery and a human saphenous vein. The analyses consider the structure of the end-to-side anastomosis, the residual stresses and the typical anisotropic and nonlinear vessel behaviors. The coronary artery is modeled as a three-layer thick-walled tube. The finite element method is employed to predict deformation and stress distribution at various stages of CABG surgery. Small variations of the arterial incision have relatively big effects on the size of the arterial opening, which depends solely on the residual stress state. The incision length has a critical influence on the graft shape and the stress in the graft wall. Stresses at the heel region are higher than those at the toe region. The changes in the mechanical environment are severe along all transitions between the venous tissue and the host artery. Particular stress concentrations occur at the incision ends. The proposed computational methodology may be useful in designing a coronary anastomotic device for reducing surgical trauma. It may improve the quantitative knowledge of vessel diseases and serve as a tool for virtual planning of vascular surgery.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Ahmed SR, Johansson BL, Karlsson MB, Souza DS, Dashwood MR, Loesch A (2004) Human saphenous vein and coronary bypass surgery: ultrastructural aspects of conventional and ‘no-touch’ vein graft preparations. Histol Histopathol 19:421–433 Ahmed SR, Johansson BL, Karlsson MB, Souza DS, Dashwood MR, Loesch A (2004) Human saphenous vein and coronary bypass surgery: ultrastructural aspects of conventional and ‘no-touch’ vein graft preparations. Histol Histopathol 19:421–433
2.
Zurück zum Zitat Ballyk PD, Walsh C, Butany J, Ojha M (1998) Compliance mismatch may promote graft artery intimal hyperplasia by altering suture-line stresses. J Biomech 31:229–237CrossRef Ballyk PD, Walsh C, Butany J, Ojha M (1998) Compliance mismatch may promote graft artery intimal hyperplasia by altering suture-line stresses. J Biomech 31:229–237CrossRef
3.
Zurück zum Zitat Bassiouny HS, White S, Glagov S, Choi E, Giddens DP, Zarins CK (1992) Anastomotic intimal hyperplasia: mechanical injury or flow induced. J Vasc Surg 15:708–716CrossRef Bassiouny HS, White S, Glagov S, Choi E, Giddens DP, Zarins CK (1992) Anastomotic intimal hyperplasia: mechanical injury or flow induced. J Vasc Surg 15:708–716CrossRef
4.
Zurück zum Zitat Chamiot-Clerc P, Copie X, Renaud JF, Safar M, Girerd X (1998) Comparative reactivity and mechanical properties of human isolated internal mammary and radial arteries. Cardiovasc Res 37:811–819CrossRef Chamiot-Clerc P, Copie X, Renaud JF, Safar M, Girerd X (1998) Comparative reactivity and mechanical properties of human isolated internal mammary and radial arteries. Cardiovasc Res 37:811–819CrossRef
5.
Zurück zum Zitat Donovan DL, Schmidt SP, Townsend SP, Njus GO, Sharp WV (1990) Material and structural characterization of human saphenous vein. J Vasc Surg 12:531–537CrossRef Donovan DL, Schmidt SP, Townsend SP, Njus GO, Sharp WV (1990) Material and structural characterization of human saphenous vein. J Vasc Surg 12:531–537CrossRef
6.
Zurück zum Zitat Fung YC, Liu SQ (1989) Change of residual strains in arteries due to hypertrophy caused by aortic constrictions. Circ Res 65:1340–1349 Fung YC, Liu SQ (1989) Change of residual strains in arteries due to hypertrophy caused by aortic constrictions. Circ Res 65:1340–1349
7.
Zurück zum Zitat Gu H, Chua A, Tan BK, Chew Hung K (2006) Nonlinear finite element simulation to elucidate the efficacy of slit arteriotomy for end-to-side arterial anastomosis in microsurgery. J Biomech 39:435–443 Gu H, Chua A, Tan BK, Chew Hung K (2006) Nonlinear finite element simulation to elucidate the efficacy of slit arteriotomy for end-to-side arterial anastomosis in microsurgery. J Biomech 39:435–443
8.
Zurück zum Zitat Hofer M, Rappitsch G, Perktold K, Trubel W, Schima H (1996) Numerical study of wall mechanics and fluid dynamics in end-to-side anastomoses and correlation to intimal hyperplasia. J Biomech 29:1297–1308CrossRef Hofer M, Rappitsch G, Perktold K, Trubel W, Schima H (1996) Numerical study of wall mechanics and fluid dynamics in end-to-side anastomoses and correlation to intimal hyperplasia. J Biomech 29:1297–1308CrossRef
9.
Zurück zum Zitat Holzapfel GA, Gasser TC, Ogden RW (2000) A new constitutive framework for arterial wall mechanics and a comparative study of material models. J Elast 61:1–48MATHCrossRefMathSciNet Holzapfel GA, Gasser TC, Ogden RW (2000) A new constitutive framework for arterial wall mechanics and a comparative study of material models. J Elast 61:1–48MATHCrossRefMathSciNet
10.
Zurück zum Zitat Holzapfel GA, Sommer G, Gasser CT, Regitnig P (2005) Determination of the layer-specific mechanical properties of human coronary arteries with non-atherosclerotic intimal thickening, and related constitutive modelling. Am J Physiol Heart Circ Physiol 289:H2048–H2058CrossRef Holzapfel GA, Sommer G, Gasser CT, Regitnig P (2005) Determination of the layer-specific mechanical properties of human coronary arteries with non-atherosclerotic intimal thickening, and related constitutive modelling. Am J Physiol Heart Circ Physiol 289:H2048–H2058CrossRef
11.
Zurück zum Zitat Holzapfel GA, Stadler M, Gasser TC (2005) Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent design. J Biomech Eng 127:166–180CrossRef Holzapfel GA, Stadler M, Gasser TC (2005) Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent design. J Biomech Eng 127:166–180CrossRef
12.
Zurück zum Zitat Hughes PE, How TV (1996) Effects of geometry and flow division on flow structures in models of the distal end-to-side anastomosis. J Biomech 29:855–872CrossRef Hughes PE, How TV (1996) Effects of geometry and flow division on flow structures in models of the distal end-to-side anastomosis. J Biomech 29:855–872CrossRef
13.
Zurück zum Zitat Humphrey JD (2002) Cardiovascular solid mechanics. Cells, tissues, and organs. Springer, New York Humphrey JD (2002) Cardiovascular solid mechanics. Cells, tissues, and organs. Springer, New York
14.
Zurück zum Zitat Kaimovitz B, Lanir Y, Kassab GS (2005) Large-scale 3-D geometric reconstruction of the porcine coronary arterial vasculature based on detailed anatomical data. Ann Biomed Eng 33:1517–1535CrossRef Kaimovitz B, Lanir Y, Kassab GS (2005) Large-scale 3-D geometric reconstruction of the porcine coronary arterial vasculature based on detailed anatomical data. Ann Biomed Eng 33:1517–1535CrossRef
15.
Zurück zum Zitat Leuprecht A, Perktold K, Prosi M, Berk T, Trubel W, Schima H (2002) Numerical study of hemodynamics and wall mechanics in distal end-to-side anastomoses of bypass grafts. J Biomech 35:225–236CrossRef Leuprecht A, Perktold K, Prosi M, Berk T, Trubel W, Schima H (2002) Numerical study of hemodynamics and wall mechanics in distal end-to-side anastomoses of bypass grafts. J Biomech 35:225–236CrossRef
16.
Zurück zum Zitat Matsumoto T, Hayashi K (1994) Mechanical and dimensional adaptation of rat aorta to hypertension. J Biomech Eng 116:278–283 Matsumoto T, Hayashi K (1994) Mechanical and dimensional adaptation of rat aorta to hypertension. J Biomech Eng 116:278–283
17.
Zurück zum Zitat Meng X, Mavromatis K, Galis ZS (1999) Mechanical stretching of human saphenous vein grafts induces expression and activation of matrix-degrading enzymes associated with vascular tissue injury and repair. Exp Mol Pathol 66:227–237CrossRef Meng X, Mavromatis K, Galis ZS (1999) Mechanical stretching of human saphenous vein grafts induces expression and activation of matrix-degrading enzymes associated with vascular tissue injury and repair. Exp Mol Pathol 66:227–237CrossRef
18.
Zurück zum Zitat Migliavacca F, Dubini G (2005) Computational modeling of vascular anastomoses. Biomech Model Mechanobio 3:235–250CrossRef Migliavacca F, Dubini G (2005) Computational modeling of vascular anastomoses. Biomech Model Mechanobio 3:235–250CrossRef
19.
Zurück zum Zitat Milesi V, Rebolledo A, Ayala-Paredes F, Sanz N, Tommasi J, Rinaldi GJ, et al (1998) Mechanical properties of human saphenous veins from normotensive and hypertensive patients. Ann Thorac Surg 66:455–461CrossRef Milesi V, Rebolledo A, Ayala-Paredes F, Sanz N, Tommasi J, Rinaldi GJ, et al (1998) Mechanical properties of human saphenous veins from normotensive and hypertensive patients. Ann Thorac Surg 66:455–461CrossRef
20.
Zurück zum Zitat Scheltes JS, van Andel CJ, Pistecky PV, Borst C (2003) Coronary anastomotic devices: blood-exposed non-intimal surface and coronary wall stress. J Thorac Cardiovasc Surg 126:191–199CrossRef Scheltes JS, van Andel CJ, Pistecky PV, Borst C (2003) Coronary anastomotic devices: blood-exposed non-intimal surface and coronary wall stress. J Thorac Cardiovasc Surg 126:191–199CrossRef
21.
Zurück zum Zitat Sottiurai VS, Yao JS, Batson RC, Sue SL, Jones R, Nakamura YA (1989) Distal anastomotic intimal hyperplasia: histopathologic character and biogenesis. Ann Vasc Surg 3:26–3 Sottiurai VS, Yao JS, Batson RC, Sue SL, Jones R, Nakamura YA (1989) Distal anastomotic intimal hyperplasia: histopathologic character and biogenesis. Ann Vasc Surg 3:26–3
22.
Zurück zum Zitat Stooker W, Gok M, Sipkema P, Niessen HW, Baidoshvili A, Westerhof N et al (2003) Pressure–diameter relationship in the human greater saphenous vein. Ann Thorac Surg 76:1533–1538CrossRef Stooker W, Gok M, Sipkema P, Niessen HW, Baidoshvili A, Westerhof N et al (2003) Pressure–diameter relationship in the human greater saphenous vein. Ann Thorac Surg 76:1533–1538CrossRef
23.
Zurück zum Zitat Taylor RL (2002) FEAP—a finite element analysis program, version 7.4 user manual. University of California at Berkeley, Berkeley Taylor RL (2002) FEAP—a finite element analysis program, version 7.4 user manual. University of California at Berkeley, Berkeley
24.
Zurück zum Zitat Townsend SP (1993) The material and structural characterization of human saphenous vein patch grafts. Master Thesis, University of Akron Townsend SP (1993) The material and structural characterization of human saphenous vein patch grafts. Master Thesis, University of Akron
25.
Zurück zum Zitat Trubel W, Moritz A, Schima H, Raderer F, Scherer R, Ullrich R, et al (1992) Compliance and formation of distal anastomotic intimal hyperplasia in Dacron mesh tube constricted veins used as arterial bypass grafts. ASAIO J 40:M273–M278CrossRef Trubel W, Moritz A, Schima H, Raderer F, Scherer R, Ullrich R, et al (1992) Compliance and formation of distal anastomotic intimal hyperplasia in Dacron mesh tube constricted veins used as arterial bypass grafts. ASAIO J 40:M273–M278CrossRef
26.
Zurück zum Zitat Trubel W, Schima H, Czerny M, Perktold K, Schimeck MG, Polterauer P (2004) Experimental comparison of four methods of end-to-side anastomosis with expanded polytetrafluoroethylene. Br J Surg 91:159–167CrossRef Trubel W, Schima H, Czerny M, Perktold K, Schimeck MG, Polterauer P (2004) Experimental comparison of four methods of end-to-side anastomosis with expanded polytetrafluoroethylene. Br J Surg 91:159–167CrossRef
27.
Zurück zum Zitat Vaishnav RN, Vossoughi J (1983) Estimation of residual strains in aortic segments. In: Hall CW (ed) Biomedical engineering ii: recent developments. Pergamon Press, New York, pp 330–333 Vaishnav RN, Vossoughi J (1983) Estimation of residual strains in aortic segments. In: Hall CW (ed) Biomedical engineering ii: recent developments. Pergamon Press, New York, pp 330–333
Metadaten
Titel
A procedure to simulate coronary artery bypass graft surgery
verfasst von
Fernando Cacho
Manuel Doblaré
Gerhard A. Holzapfel
Publikationsdatum
01.09.2007
Verlag
Springer-Verlag
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 9/2007
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-007-0201-2

Weitere Artikel der Ausgabe 9/2007

Medical & Biological Engineering & Computing 9/2007 Zur Ausgabe

Premium Partner