Skip to main content
Erschienen in: Microsystem Technologies 4/2013

01.04.2013 | Technical Paper

A water-immersible 2-axis scanning mirror microsystem for ultrasound andha photoacoustic microscopic imaging applications

verfasst von: Chih-Hsien Huang, Junjie Yao, Lihong V. Wang, Jun Zou

Erschienen in: Microsystem Technologies | Ausgabe 4/2013

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Fast scanning is highly desired for both ultrasound and photoacoustic microscopic imaging, whereas the liquid environment required for acoustic propagation limits the usage of traditional microelectromechanical systems (MEMS) scanning mirrors. Here, a new water-immersible scanning mirror microsystem has been designed, fabricated and tested. To achieve reliable underwater scanning, flexible polymer torsion hinges fabricated by laser micromachining were used to support the reflective silicon mirror plate. Two efficient electromagnetic microactuators consisting of compact RF choke inductors and high-strength neodymium magnet disc were constructed to drive the silicon mirror plate around a fast axis and a slow axis. The performance of this water-immersible scanning mirror microsystem in both air and water were tested using the laser tracing method. For the fast axis, the resonance frequency reached 224 Hz in air and 164 Hz in water, respectively. The scanning angles in both air and water under ±16 V DC driving were ±12°. The scanning angles in air and water under ±10 V AC driving (at the resonance frequencies) were ±13.6° and ±10°. For the slow axis, the resonance frequency reached 55 Hz in air and 38 Hz in water, respectively. The scanning angles in both air and water under ±10 V DC driving were ±6.5°. The scanning angles in air and water under ±10 V AC driving (at the resonance frequencies) were ±8.5° and ±6°. The feasibility of using such a water-immersible scanning mirror microsystem for scanning ultrasound microscopic imaging has been demonstrated with a 25-MHz ultrasound pulse/echo system and a target consisting of three optical fibers.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Chen WH, Gottlieb EJ, Cannata JM, Chen YF, Shung KK (2000) Development of sector scanning ultrasonic backscatter microscope. 2000 IEEE Ultrasonics Symposium Chen WH, Gottlieb EJ, Cannata JM, Chen YF, Shung KK (2000) Development of sector scanning ultrasonic backscatter microscope. 2000 IEEE Ultrasonics Symposium
Zurück zum Zitat Cornelis AVE, John ES (2006) Resonant frequencies of a rectangular cantilever beam immersed in a fluid. J Appl Phys 100:114916CrossRef Cornelis AVE, John ES (2006) Resonant frequencies of a rectangular cantilever beam immersed in a fluid. J Appl Phys 100:114916CrossRef
Zurück zum Zitat Hagelin PM, Krishnamoorthy U, Heritage JP, Solgaard O (2000) Scalable optical cross-connect switch using micromachined mirrors. IEEE Photonics Technol Lett 12:882–884CrossRef Hagelin PM, Krishnamoorthy U, Heritage JP, Solgaard O (2000) Scalable optical cross-connect switch using micromachined mirrors. IEEE Photonics Technol Lett 12:882–884CrossRef
Zurück zum Zitat Hyejun R, Piyawattanametha W, Taguchi Y, Daesung L, Mandella MJ, Solgaard O (2007) Two-dimensional MEMS scanner for dual-axes confocal microscopy. J Microelectromech Syst 16:969–976CrossRef Hyejun R, Piyawattanametha W, Taguchi Y, Daesung L, Mandella MJ, Solgaard O (2007) Two-dimensional MEMS scanner for dual-axes confocal microscopy. J Microelectromech Syst 16:969–976CrossRef
Zurück zum Zitat Jung WY, Tang S, McCormic DT, Xie TQ, Ahn YC, Su JP, Tomov IV, Krasieva TB, Tromberg BJ, Chen ZP (2008) Miniaturized probe based on a microelectromechanical system mirror for multiphoton microscopy. Opt Lett 33:1324–1326CrossRef Jung WY, Tang S, McCormic DT, Xie TQ, Ahn YC, Su JP, Tomov IV, Krasieva TB, Tromberg BJ, Chen ZP (2008) Miniaturized probe based on a microelectromechanical system mirror for multiphoton microscopy. Opt Lett 33:1324–1326CrossRef
Zurück zum Zitat Liu C (2006) Foundations of MEMS. Upper Saddle River, NJ Liu C (2006) Foundations of MEMS. Upper Saddle River, NJ
Zurück zum Zitat Wang LV (2009) Multiscale photoacoustic microscopy and computed tomography. Nat Photonics 3:503–509CrossRef Wang LV (2009) Multiscale photoacoustic microscopy and computed tomography. Nat Photonics 3:503–509CrossRef
Zurück zum Zitat Wang L, Maslov K, Yao J, Rao B, Wang LV (2011) Fast voice-coil scanning optical-resolution photoacoustic microscopy. Opt Lett 36:139–141CrossRef Wang L, Maslov K, Yao J, Rao B, Wang LV (2011) Fast voice-coil scanning optical-resolution photoacoustic microscopy. Opt Lett 36:139–141CrossRef
Zurück zum Zitat Yang VXD, Mao YX, Standish BA, Munce NR, Chiu S, Burnes D, Wilson BC, Vitkin IA, Himmer PA, Dickensheets DL (2006) Doppler optical coherence tomography with a micro-electro-mechanical membrane mirror for high-speed dynamic focus tracking. Opt Lett 31:1262–1264CrossRef Yang VXD, Mao YX, Standish BA, Munce NR, Chiu S, Burnes D, Wilson BC, Vitkin IA, Himmer PA, Dickensheets DL (2006) Doppler optical coherence tomography with a micro-electro-mechanical membrane mirror for high-speed dynamic focus tracking. Opt Lett 31:1262–1264CrossRef
Zurück zum Zitat Yao J, Wang LV (2011) Photoacoustic tomography: fundamentals, advances and prospects. Contrast Media Mol Imaging 6:332–345CrossRef Yao J, Wang LV (2011) Photoacoustic tomography: fundamentals, advances and prospects. Contrast Media Mol Imaging 6:332–345CrossRef
Zurück zum Zitat Yao J, Maslov KI, Zhang Y, Xia Y, Wang LV (2011) Label-free oxygen-metabolic photoacoustic microscopy in vivo. J Biomed Opt 16:076003CrossRef Yao J, Maslov KI, Zhang Y, Xia Y, Wang LV (2011) Label-free oxygen-metabolic photoacoustic microscopy in vivo. J Biomed Opt 16:076003CrossRef
Metadaten
Titel
A water-immersible 2-axis scanning mirror microsystem for ultrasound andha photoacoustic microscopic imaging applications
verfasst von
Chih-Hsien Huang
Junjie Yao
Lihong V. Wang
Jun Zou
Publikationsdatum
01.04.2013
Verlag
Springer-Verlag
Erschienen in
Microsystem Technologies / Ausgabe 4/2013
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-012-1660-4

Weitere Artikel der Ausgabe 4/2013

Microsystem Technologies 4/2013 Zur Ausgabe

Neuer Inhalt