Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 6/2018

18.11.2017 | Original Article

Beat-to-beat estimation of stroke volume using impedance cardiography and artificial neural network

verfasst von: S. M. M. Naidu, Prem C. Pandey, Uttam R. Bagal, Suhas P. Hardas

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 6/2018

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Impedance cardiography is a low-cost noninvasive technique, based on monitoring of the thoracic impedance, for estimation of stroke volume (SV). Impedance cardiogram (ICG) is the negative of the first derivative of the impedance signal. A technique for beat-to-beat SV estimation using impedance cardiography and artificial neural network (ANN) is proposed. A three-layer feed-forward ANN with error back-propagation algorithm is optimized by examining the effects of number of neurons in the hidden layer, activation function, training algorithm, and set of input parameters. The input parameters are obtained by automatic detection of the ICG characteristic points, and the target values are obtained by beat-to-beat SV measurements from time-aligned Doppler echocardiogram. The technique is evaluated using an ICG-echocardiography database with recordings from subjects with normal health in the under-rest and post-exercise conditions and from subjects with cardiovascular disorders in the under-rest condition. The proposed technique performed much better than the earlier established equation-based estimations, and it resulted in correlation coefficient of 0.93 for recordings from subjects with cardiovascular disorders. It may be helpful in improving the acceptability of impedance cardiography in clinical practice.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Arora D, Chand R, Mehta Y, Trehan N (2007) Cardiac output estimation after off-pump coronary artery bypass: a comparison of two different techniques. Ann Card Anaesth 10(2):132–136CrossRefPubMed Arora D, Chand R, Mehta Y, Trehan N (2007) Cardiac output estimation after off-pump coronary artery bypass: a comparison of two different techniques. Ann Card Anaesth 10(2):132–136CrossRefPubMed
2.
Zurück zum Zitat Aust PE, Belz GG, Belz G, Koch W (1982) Comparison of impedance cardiography and echocardiography for measurement of stroke volume. Eur J Clin Pharmacol 23(6):475–477CrossRefPubMed Aust PE, Belz GG, Belz G, Koch W (1982) Comparison of impedance cardiography and echocardiography for measurement of stroke volume. Eur J Clin Pharmacol 23(6):475–477CrossRefPubMed
4.
Zurück zum Zitat Baumgartner H, Hung J, Bermejo J, Chambers JB, Evangelista A, Griffin BP, Iung B, Otto CM, Pellikka PA, Quiñones M (2009) Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. Eur J Echocardiography 10:1–25CrossRef Baumgartner H, Hung J, Bermejo J, Chambers JB, Evangelista A, Griffin BP, Iung B, Otto CM, Pellikka PA, Quiñones M (2009) Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. Eur J Echocardiography 10:1–25CrossRef
5.
Zurück zum Zitat Baura GD (2001) Noninvasive continuous cardiac output monitor US Patent No US 6186955 B1 Baura GD (2001) Noninvasive continuous cardiac output monitor US Patent No US 6186955 B1
6.
Zurück zum Zitat Bernstein DP, Lemmens HJM (2005) Stroke volume equation for impedance cardiography. Med Biol Eng Comput 43(4):443–450CrossRefPubMed Bernstein DP, Lemmens HJM (2005) Stroke volume equation for impedance cardiography. Med Biol Eng Comput 43(4):443–450CrossRefPubMed
7.
Zurück zum Zitat Bruce RA, Lovejoy FW Jr, Pearson R, PNG Y, Brothers GB, Velasquez T (1949) Normal respiratory and circulatory pathways of adaptation in exercise. J Clin Invest 28(6 Pt 2):1423–1430CrossRefPubMedPubMedCentral Bruce RA, Lovejoy FW Jr, Pearson R, PNG Y, Brothers GB, Velasquez T (1949) Normal respiratory and circulatory pathways of adaptation in exercise. J Clin Invest 28(6 Pt 2):1423–1430CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Castor G, Klocke RK, Stoll M, Helms J, Niedermark I (1994) Simultaneous measurement of cardiac output by thermodilution, thoracic electrical bioimpedance and Doppler ultrasound. Br J Anaesth 72(1):133–138CrossRefPubMed Castor G, Klocke RK, Stoll M, Helms J, Niedermark I (1994) Simultaneous measurement of cardiac output by thermodilution, thoracic electrical bioimpedance and Doppler ultrasound. Br J Anaesth 72(1):133–138CrossRefPubMed
9.
Zurück zum Zitat De Maria AN, Raisinghani A (2000) Comparative overview of cardiac output measurement methods: has impedance cardiography come of age? Congest Heart Fail 6(2):60–73CrossRefPubMed De Maria AN, Raisinghani A (2000) Comparative overview of cardiac output measurement methods: has impedance cardiography come of age? Congest Heart Fail 6(2):60–73CrossRefPubMed
10.
Zurück zum Zitat Elstad M, Walloe L (2015) Heart rate variability and stroke volume variability to detect central hypovolemia during spontaneous breathing and supported ventilation in young, healthy volunteers. Physiol Meas 36(4):671–681CrossRefPubMed Elstad M, Walloe L (2015) Heart rate variability and stroke volume variability to detect central hypovolemia during spontaneous breathing and supported ventilation in young, healthy volunteers. Physiol Meas 36(4):671–681CrossRefPubMed
11.
Zurück zum Zitat Ermishkin VV, Kolesnikov VA, Lukoshkova EV (2014) Age-dependent and pathologic changes in ICG waveforms resulting from superposition of pre-ejection and ejection waves. Physiol Meas 35(6):943–963CrossRefPubMed Ermishkin VV, Kolesnikov VA, Lukoshkova EV (2014) Age-dependent and pathologic changes in ICG waveforms resulting from superposition of pre-ejection and ejection waves. Physiol Meas 35(6):943–963CrossRefPubMed
12.
Zurück zum Zitat Fellahi JL, Caille V, Charron C, Deschamps-Berger PH, Vieillard-Baron A (2009) Noninvasive assessment of cardiac index in healthy volunteers: a comparison between thoracic impedance cardiography and Doppler echocardiography. Anesth Analg 108(5):1553–1559CrossRefPubMed Fellahi JL, Caille V, Charron C, Deschamps-Berger PH, Vieillard-Baron A (2009) Noninvasive assessment of cardiac index in healthy volunteers: a comparison between thoracic impedance cardiography and Doppler echocardiography. Anesth Analg 108(5):1553–1559CrossRefPubMed
13.
Zurück zum Zitat Fortin J et al (2006) Non-invasive beat-to-beat cardiac output monitoring by an improved method of transthoracic bioimpedance measurement. Comp Biol Med 36(11):1185–1203CrossRef Fortin J et al (2006) Non-invasive beat-to-beat cardiac output monitoring by an improved method of transthoracic bioimpedance measurement. Comp Biol Med 36(11):1185–1203CrossRef
14.
Zurück zum Zitat Guyton AC, Hall JE (2006) Textbook of medical physiology, 11th edn. Saunders, Elsevier Guyton AC, Hall JE (2006) Textbook of medical physiology, 11th edn. Saunders, Elsevier
15.
Zurück zum Zitat Haykin S (1999) Neural networks: a comprehensive foundation, 2nd edn, Prentice Hall, Upper Saddle River Haykin S (1999) Neural networks: a comprehensive foundation, 2nd edn, Prentice Hall, Upper Saddle River
16.
Zurück zum Zitat Hoff IE, Hoiseth LO, Hisdal J, Roislien J, Landsverk SA, Kirkeboen KA (2014) Respiratory variations in pulse pressure reflect central hypovolemia during noninvasive positive pressure ventilation. Crit Care Res Pract 2014:9. https://doi.org/10.1155/2014/712728 Hoff IE, Hoiseth LO, Hisdal J, Roislien J, Landsverk SA, Kirkeboen KA (2014) Respiratory variations in pulse pressure reflect central hypovolemia during noninvasive positive pressure ventilation. Crit Care Res Pract 2014:9. https://​doi.​org/​10.​1155/​2014/​712728
17.
Zurück zum Zitat Holme NL, Rein EB, Elstad M (2016) Cardiac stroke volume variability measured non-invasively by three methods for detection of central hypovolemia in healthy humans. Eur J Appl Physiol 116(11–12):2187–2196CrossRefPubMed Holme NL, Rein EB, Elstad M (2016) Cardiac stroke volume variability measured non-invasively by three methods for detection of central hypovolemia in healthy humans. Eur J Appl Physiol 116(11–12):2187–2196CrossRefPubMed
18.
Zurück zum Zitat Hurwitz BE, Shyu L-Y, Reddy SP, Schneiderman N, Nagel JH (1990) Coherent ensemble averaging techniques for impedance cardiography. In: Proc 3rd Ann IEEE Symp CBMS, Chapel Hill, pp 228–235 Hurwitz BE, Shyu L-Y, Reddy SP, Schneiderman N, Nagel JH (1990) Coherent ensemble averaging techniques for impedance cardiography. In: Proc 3rd Ann IEEE Symp CBMS, Chapel Hill, pp 228–235
19.
Zurück zum Zitat Jensen L, Yakimets J, Teo KK (1995) A review of impedance cardiography. Heart & Lung: J Acute Crit Care 24(3):183–193CrossRef Jensen L, Yakimets J, Teo KK (1995) A review of impedance cardiography. Heart & Lung: J Acute Crit Care 24(3):183–193CrossRef
20.
Zurück zum Zitat Kerr AJ, Simmonds MB, Stewart RA (1998) Influence of heart rate on stroke volume variability in atrial fibrillation in patients with normal and impaired left ventricular function. Am J Cardiol 82(12):1496–1500CrossRefPubMed Kerr AJ, Simmonds MB, Stewart RA (1998) Influence of heart rate on stroke volume variability in atrial fibrillation in patients with normal and impaired left ventricular function. Am J Cardiol 82(12):1496–1500CrossRefPubMed
21.
Zurück zum Zitat Kieback AG, Borges AC, Schink T, Baumann G, Laule M (2010) Impedance cardiography versus invasive measurements of stroke volume index in patients with chronic heart failure. Int J Cardiol 143(2):211–213CrossRefPubMed Kieback AG, Borges AC, Schink T, Baumann G, Laule M (2010) Impedance cardiography versus invasive measurements of stroke volume index in patients with chronic heart failure. Int J Cardiol 143(2):211–213CrossRefPubMed
22.
23.
Zurück zum Zitat Kizakevich PN, Teague SM, Nissman DB, Jochem WJ, Niclou R, Sharma MK (1993) Comparative measures of systolic ejection during treadmill exercise by impedance cardiography and Doppler echocardiography. Biol Psychol 36(1–2):51–61CrossRefPubMed Kizakevich PN, Teague SM, Nissman DB, Jochem WJ, Niclou R, Sharma MK (1993) Comparative measures of systolic ejection during treadmill exercise by impedance cardiography and Doppler echocardiography. Biol Psychol 36(1–2):51–61CrossRefPubMed
24.
Zurück zum Zitat Korhonen I, Koobi T, Turjanmaa V (1999) Beat-to-beat variability of stroke volume measured by whole-body impedance cardiography. Med Biol Eng Comput 37(Suppl.1):61–62 Korhonen I, Koobi T, Turjanmaa V (1999) Beat-to-beat variability of stroke volume measured by whole-body impedance cardiography. Med Biol Eng Comput 37(Suppl.1):61–62
25.
Zurück zum Zitat Kubicek WG, Kottke FJ, Ramos MU, Patterson RP, Witsoe DA, Labree JW, Remole W, Layman TE, Schoening H, Garamela JT (1974) The Minnesota impedance cardiograph theory and applications. Biomed Eng 9(9):410–416PubMed Kubicek WG, Kottke FJ, Ramos MU, Patterson RP, Witsoe DA, Labree JW, Remole W, Layman TE, Schoening H, Garamela JT (1974) The Minnesota impedance cardiograph theory and applications. Biomed Eng 9(9):410–416PubMed
26.
Zurück zum Zitat Lababidi Z, Ehmke DA, Durnin RE, Leaverton PE, Lauer RM (1970) The first derivative thoracic impedance cardiogram. Circulation 41(4):651–658CrossRefPubMed Lababidi Z, Ehmke DA, Durnin RE, Leaverton PE, Lauer RM (1970) The first derivative thoracic impedance cardiogram. Circulation 41(4):651–658CrossRefPubMed
27.
Zurück zum Zitat Lababidi Z, Ehmke DA, Durnin RE, Leaverton PE, Lauer RM (1971) Evaluation of impedance cardiac output in children. Pediatrics 47(5):870–879PubMed Lababidi Z, Ehmke DA, Durnin RE, Leaverton PE, Lauer RM (1971) Evaluation of impedance cardiac output in children. Pediatrics 47(5):870–879PubMed
28.
Zurück zum Zitat Lewis JF, Kuo LC, Nelson JG, Limacher MC, Quinones MA (1984) Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. Circulation 70(3):425–431CrossRefPubMed Lewis JF, Kuo LC, Nelson JG, Limacher MC, Quinones MA (1984) Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. Circulation 70(3):425–431CrossRefPubMed
29.
Zurück zum Zitat Liu H, Yambe T, Sasada H, Nanka S, Tanaka S, Nagatomi R, Nitta S (2004) Comparison of heart rate variability and stroke volume variability. Auton Neurosci 116(1–2):69–75CrossRefPubMed Liu H, Yambe T, Sasada H, Nanka S, Tanaka S, Nagatomi R, Nitta S (2004) Comparison of heart rate variability and stroke volume variability. Auton Neurosci 116(1–2):69–75CrossRefPubMed
30.
Zurück zum Zitat Marik PE, Cavallazzi R, Vasu T, Hirani A (2009) Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 37(9):2642–2647CrossRefPubMed Marik PE, Cavallazzi R, Vasu T, Hirani A (2009) Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 37(9):2642–2647CrossRefPubMed
31.
Zurück zum Zitat Mulavara AP, Timmons WD, Nair MS, Gupta V, Kumar AA, Taylor BC (1998) Electrical impedance cardiography using artificial neural networks. Ann Biomed Eng 26(4):577–583CrossRefPubMed Mulavara AP, Timmons WD, Nair MS, Gupta V, Kumar AA, Taylor BC (1998) Electrical impedance cardiography using artificial neural networks. Ann Biomed Eng 26(4):577–583CrossRefPubMed
32.
Zurück zum Zitat Naidu SMM, Bagal UR, Pandey PC, Hardas S, Khambete ND (2014) Detection of characterisitc points of impedance cardiogram and validation using Doppler echocardiography. In Proc 11th Ann Conference of the IEEE India Council (Indicon 2014), Pune, India, doi: https://doi.org/10.1109/INDICON.2014.7030596 Naidu SMM, Bagal UR, Pandey PC, Hardas S, Khambete ND (2014) Detection of characterisitc points of impedance cardiogram and validation using Doppler echocardiography. In Proc 11th Ann Conference of the IEEE India Council (Indicon 2014), Pune, India, doi: https://​doi.​org/​10.​1109/​INDICON.​2014.​7030596
33.
Zurück zum Zitat Nelson N, Janerot-Sjoberg B (2001) Beat-to-beat changes in stroke volume precede the general circulatory effects of mechanical ventilation: a case report. Crit Care 5(1):41–45CrossRefPubMedPubMedCentral Nelson N, Janerot-Sjoberg B (2001) Beat-to-beat changes in stroke volume precede the general circulatory effects of mechanical ventilation: a case report. Crit Care 5(1):41–45CrossRefPubMedPubMedCentral
34.
Zurück zum Zitat Nocedal J, Wright SJ (1999) Nonlinear least-squares problems. In: Glynn P, Robinson SM (eds) Numerical Optimization. Springer, New York, pp 262–266CrossRef Nocedal J, Wright SJ (1999) Nonlinear least-squares problems. In: Glynn P, Robinson SM (eds) Numerical Optimization. Springer, New York, pp 262–266CrossRef
35.
Zurück zum Zitat Northridge DB, Findlay IN, Wilson J, Henderson E, Dargie HJ (1990) Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance. Br Heart J 63(2):93–97CrossRefPubMedPubMedCentral Northridge DB, Findlay IN, Wilson J, Henderson E, Dargie HJ (1990) Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance. Br Heart J 63(2):93–97CrossRefPubMedPubMedCentral
36.
Zurück zum Zitat Ono T, Miyamura M, Yasuda Y, Ito T, Saito T, Ishiguro T, Yoshizawa M, Yambe T (2004) Beat-to-beat evaluation of systolic time intervals during bicycle exercise using impedance cardiography. Tohoku J Exp Med 203(1):17–29CrossRefPubMed Ono T, Miyamura M, Yasuda Y, Ito T, Saito T, Ishiguro T, Yoshizawa M, Yambe T (2004) Beat-to-beat evaluation of systolic time intervals during bicycle exercise using impedance cardiography. Tohoku J Exp Med 203(1):17–29CrossRefPubMed
37.
Zurück zum Zitat Patterson RP (1989) Fundamentals of impedance cardiography. IEEE Eng Med Biol Mag 8(1):35–38CrossRefPubMed Patterson RP (1989) Fundamentals of impedance cardiography. IEEE Eng Med Biol Mag 8(1):35–38CrossRefPubMed
38.
Zurück zum Zitat Peterson GE, Brickner ME, Reimold SC (2003) Transesophageal echocardiography: clinical indications and applications. Circulation 107(19):2398–2402CrossRefPubMed Peterson GE, Brickner ME, Reimold SC (2003) Transesophageal echocardiography: clinical indications and applications. Circulation 107(19):2398–2402CrossRefPubMed
39.
Zurück zum Zitat Qu M, Zhang Y, Webster JG, Tompkins WJ (1986) Motion artifact from spot and band electrodes during impedance cardiography. IEEE Trans Biomed Eng 33(11):1029–1036CrossRefPubMed Qu M, Zhang Y, Webster JG, Tompkins WJ (1986) Motion artifact from spot and band electrodes during impedance cardiography. IEEE Trans Biomed Eng 33(11):1029–1036CrossRefPubMed
40.
Zurück zum Zitat Scherhag A, Kaden JJ, Kentschke E, Sueselbeck T, Borggrefe M (2005) Comparison of impedance cardiography and thermodilution-derived measurements of stroke volume and cardiac output at rest and during exercise testing. Cardiovasc Drugs Ther 19(2):141–147CrossRefPubMed Scherhag A, Kaden JJ, Kentschke E, Sueselbeck T, Borggrefe M (2005) Comparison of impedance cardiography and thermodilution-derived measurements of stroke volume and cardiac output at rest and during exercise testing. Cardiovasc Drugs Ther 19(2):141–147CrossRefPubMed
41.
Zurück zum Zitat Sherwood A, Allen MT, Fahrenberg J, Kelsey RM, Lovallo WR, van Doornen LJ (1990) Methodological guidelines for impedance cardiography. Psychophysiology 27(1):1–23CrossRefPubMed Sherwood A, Allen MT, Fahrenberg J, Kelsey RM, Lovallo WR, van Doornen LJ (1990) Methodological guidelines for impedance cardiography. Psychophysiology 27(1):1–23CrossRefPubMed
42.
Zurück zum Zitat Sherwood A, McFetridge J, Hutcheson JS (1998) Ambulatory impedance cardiography: a feasibility study. J Appl Physiol 85(6):2365–2369CrossRefPubMed Sherwood A, McFetridge J, Hutcheson JS (1998) Ambulatory impedance cardiography: a feasibility study. J Appl Physiol 85(6):2365–2369CrossRefPubMed
43.
Zurück zum Zitat Siebert J, Drabik P, Lango R, Szyndler K (2004) Stroke volume variability and heart rate power spectrum in relation to posture changes in healthy subjects. Med Sci Monit 10(2):MT31–MT37PubMed Siebert J, Drabik P, Lango R, Szyndler K (2004) Stroke volume variability and heart rate power spectrum in relation to posture changes in healthy subjects. Med Sci Monit 10(2):MT31–MT37PubMed
44.
Zurück zum Zitat Sramek B (1984) Noninvasive continuous cardiac output monitor. US Patent 4450527 Sramek B (1984) Noninvasive continuous cardiac output monitor. US Patent 4450527
45.
Zurück zum Zitat Summers RL, Shoemaker WC, Peacock WF, Ander DS, Coleman TG (2003) Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography. Acad Emerg Med 10(6):669–680CrossRefPubMed Summers RL, Shoemaker WC, Peacock WF, Ander DS, Coleman TG (2003) Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography. Acad Emerg Med 10(6):669–680CrossRefPubMed
46.
Zurück zum Zitat Takada K, Fujinami T, Senda K, Nakayama K, Nakano S (1977) Clinical study of ‘A waves’ (atrial waves) in impedance cardiograms. Am Heart J 94(6):710–717CrossRefPubMed Takada K, Fujinami T, Senda K, Nakayama K, Nakano S (1977) Clinical study of ‘A waves’ (atrial waves) in impedance cardiograms. Am Heart J 94(6):710–717CrossRefPubMed
47.
Zurück zum Zitat Tang WH, Tong W (2009) Measuring impedance in congestive heart failure: current options and clinical applications. Am Heart J 157(3):402–411CrossRefPubMed Tang WH, Tong W (2009) Measuring impedance in congestive heart failure: current options and clinical applications. Am Heart J 157(3):402–411CrossRefPubMed
48.
Zurück zum Zitat van der Meer NJ, Noordegraaf AV, Kamp O, De Vries PM (1999) Noninvasive measurement of cardiac output: two methods compared in patients with mitral regurgitation. Angiology 50(2):95–101CrossRefPubMed van der Meer NJ, Noordegraaf AV, Kamp O, De Vries PM (1999) Noninvasive measurement of cardiac output: two methods compared in patients with mitral regurgitation. Angiology 50(2):95–101CrossRefPubMed
49.
Zurück zum Zitat Van De Water JM, Miller TW, Vogel RL, Mount BE, Dalton ML (2003) Impedance cardiography: the next vital sign technology? Chest 123(6):2028–2033CrossRef Van De Water JM, Miller TW, Vogel RL, Mount BE, Dalton ML (2003) Impedance cardiography: the next vital sign technology? Chest 123(6):2028–2033CrossRef
50.
Zurück zum Zitat Wang XA, Sun HH, Adamson D, Van de Water JM (1989) An impedance cardiography system: a new design. Ann Biomed Eng 17(5):535–556CrossRefPubMed Wang XA, Sun HH, Adamson D, Van de Water JM (1989) An impedance cardiography system: a new design. Ann Biomed Eng 17(5):535–556CrossRefPubMed
51.
Zurück zum Zitat Woltjer HH, Bogaard HJ, Scheffer GJ, van der Spoel HI, Huybregts MA, de Vries PM (1996) Standardization of non-invasive impedance cardiography for assessment of stroke volume: comparison with thermodilution. Br J Anaesth 77(6):748–752CrossRefPubMed Woltjer HH, Bogaard HJ, Scheffer GJ, van der Spoel HI, Huybregts MA, de Vries PM (1996) Standardization of non-invasive impedance cardiography for assessment of stroke volume: comparison with thermodilution. Br J Anaesth 77(6):748–752CrossRefPubMed
Metadaten
Titel
Beat-to-beat estimation of stroke volume using impedance cardiography and artificial neural network
verfasst von
S. M. M. Naidu
Prem C. Pandey
Uttam R. Bagal
Suhas P. Hardas
Publikationsdatum
18.11.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 6/2018
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-017-1752-5

Weitere Artikel der Ausgabe 6/2018

Medical & Biological Engineering & Computing 6/2018 Zur Ausgabe