Collapse-free thermal bonding technique for large area microchambers in plastic lab-on-a-chip applications

verfasst von: Dong Sung Kim, Hyun Sup Lee, Jungyoup Han, Se Hwan Lee, Chong H. Ahn, Tai Hun Kwon

Erschienen in: Microsystem Technologies | Ausgabe 2/2008

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Bonding is an essential step to form microchannels or microchambers in lab-on-a-chip applications. In this paper, we present a novel plastic thermal bonding technique to seal and form large area microchambers (planar characteristic width and length on the order of 1 mm and characteristic thickness on the order of 10–100 μm) without collapse by introducing a holed pressure equalizing plate (HPEP) that includes holes of the same size and shape as the microchambers. To demonstrate the proposed technique, two types of large area microchambers [(1) 20 × 10 mm and 40 μm thick and (2) 12 × 2.5 mm and 120 μm thick] with microchannels were designed and replicated on plastic substrates by means of hot embossing and injection molding processes with prepared two nickel mold inserts. The replicated large area microchambers as well as the microchannels in the plastic lab-on-a-chip were successfully sealed (i.e., no leakage) and formed without any collapse by the proposed thermal bonding technique with the help of the HPEP.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Anderson H, van der Wijngaart W, Stemme G (2001) Micromachined filter-chamber array with passive valves for biochemical assays on beads. Electrophoresis 22:249–257CrossRef Anderson H, van der Wijngaart W, Stemme G (2001) Micromachined filter-chamber array with passive valves for biochemical assays on beads. Electrophoresis 22:249–257CrossRef
Zurück zum Zitat Becker H, Gärtner C (2000) Polymer microfabrication methods for microfluidic analytical applications. Electrophoresis 21:12–26CrossRef Becker H, Gärtner C (2000) Polymer microfabrication methods for microfluidic analytical applications. Electrophoresis 21:12–26CrossRef
Zurück zum Zitat Kanai M, Abe H, Munaka T, Fujiyama Y, Uchida D, Yamayoshi A, Nakanishi H, Murakami A, Shoji S (2004) Micro chamber for cellar analysis integrated with negligible dead volume sample injector. Sens Actuator A 114:129–134CrossRef Kanai M, Abe H, Munaka T, Fujiyama Y, Uchida D, Yamayoshi A, Nakanishi H, Murakami A, Shoji S (2004) Micro chamber for cellar analysis integrated with negligible dead volume sample injector. Sens Actuator A 114:129–134CrossRef
Zurück zum Zitat Kim DS, Lee SH, Ahn CH, Lee JY, Kwon TH (2006) Disposable integrated microfluidic biochip for blood typing by plastic microinjection moulding. Lab Chip 6:794–802CrossRef Kim DS, Lee SH, Ahn CH, Lee JY, Kwon TH (2006) Disposable integrated microfluidic biochip for blood typing by plastic microinjection moulding. Lab Chip 6:794–802CrossRef
Zurück zum Zitat Lee HS, Kim DS, Kwon T H (2003) A novel low temperature bonding technique for plastic substrates using deep X-ray irradiation. Proceedings of international conference on solid-state sensors, actuators and microsystems (Transducers’03), Boston, USA, pp 1331–1334 Lee HS, Kim DS, Kwon T H (2003) A novel low temperature bonding technique for plastic substrates using deep X-ray irradiation. Proceedings of international conference on solid-state sensors, actuators and microsystems (Transducers’03), Boston, USA, pp 1331–1334
Zurück zum Zitat Luo JK, Chu DP, Flewitt AJ, Spearing SM, Fleck NA, Milne WI (2005) Uniformity control of Ni thin-film microstructures deposited by through-mask plating. J Electochem Soc 152:C36–C41CrossRef Luo JK, Chu DP, Flewitt AJ, Spearing SM, Fleck NA, Milne WI (2005) Uniformity control of Ni thin-film microstructures deposited by through-mask plating. J Electochem Soc 152:C36–C41CrossRef
Zurück zum Zitat Oh KW, Han A, Bhansali S, Ahn CH (2002) A low-temperature bonding technique using spin-on fluorocarbon polymers to assemble microsystems. J Micromech Microeng 12:187–191CrossRef Oh KW, Han A, Bhansali S, Ahn CH (2002) A low-temperature bonding technique using spin-on fluorocarbon polymers to assemble microsystems. J Micromech Microeng 12:187–191CrossRef
Zurück zum Zitat Puntambekar A, Murugesan S, Trichur R, Cho HJ, Kim S, Choi J-W, Beaucage G, Ahn CH (2002) Effect of surface modification on thermoplastic fusion bonding for 3-D microfluidics. Proceedings of micro total analysis systems (μTAS) 2002, Nara, Japan, pp 425–427 Puntambekar A, Murugesan S, Trichur R, Cho HJ, Kim S, Choi J-W, Beaucage G, Ahn CH (2002) Effect of surface modification on thermoplastic fusion bonding for 3-D microfluidics. Proceedings of micro total analysis systems (μTAS) 2002, Nara, Japan, pp 425–427
Zurück zum Zitat Yu X, Zhang D, Li T, Hao L, Li X (2003) 3-D microarrays biochip for DNA amplification in polydimethylsiloxane (PDMS) elastomer. Sens Actuator A 108:103–107CrossRef Yu X, Zhang D, Li T, Hao L, Li X (2003) 3-D microarrays biochip for DNA amplification in polydimethylsiloxane (PDMS) elastomer. Sens Actuator A 108:103–107CrossRef
Metadaten
Titel
Collapse-free thermal bonding technique for large area microchambers in plastic lab-on-a-chip applications
verfasst von
Dong Sung Kim
Hyun Sup Lee
Jungyoup Han
Se Hwan Lee
Chong H. Ahn
Tai Hun Kwon
Publikationsdatum
01.02.2008
Verlag
Springer-Verlag
Erschienen in
Microsystem Technologies / Ausgabe 2/2008
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-007-0416-z

Weitere Artikel der Ausgabe 2/2008

Microsystem Technologies 2/2008 Zur Ausgabe

Neuer Inhalt