Skip to main content
Erschienen in: Microsystem Technologies 6/2021

03.01.2021 | Technical Paper

Investigation of long term drift of an intraocular pressure sensor

verfasst von: Alex Phan, Phuong Truong, Christoph Schade, Aditya Vasan, James Friend, Frank E. Talke

Erschienen in: Microsystem Technologies | Ausgabe 6/2021

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

“Zero drift” behavior of an optical intraocular pressure sensor is studied using an analytical model based on the deflection of a circular membrane. Results from the analytical model were verified with experimental results from “bulge” testing. The analytical model was used to study the zero drift of the sensor as a function of changes in membrane thickness, geometry of the sensor and amount of gas inside the cavity of the sensor. The results show that dissolution of the membrane, swelling of the spacer layer and oxidative aging can contribute significantly to zero drift of the sensor over time. The results are useful in guiding design and fabrication optimization to minimize drift in intraocular pressure sensors used for long term implantation.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Beams JW (1959) Mechanical properties of thin films of gold and silver. In: Neugebauer CA, Newkirk JB, Vermilyea DA (eds) Structures and properties of thin films. Wiley, New York, pp 183–192 Beams JW (1959) Mechanical properties of thin films of gold and silver. In: Neugebauer CA, Newkirk JB, Vermilyea DA (eds) Structures and properties of thin films. Wiley, New York, pp 183–192
Zurück zum Zitat Chen K-S, Kuang-Shun Ou (2015) “MEMS Residual Stress Characterization: Methodology and Perspective.” Handbook of Silicon Based MEMS Materials and Technologies, William Andrew Publishing, pp. 398–412 Chen K-S, Kuang-Shun Ou (2015) “MEMS Residual Stress Characterization: Methodology and Perspective.” Handbook of Silicon Based MEMS Materials and Technologies, William Andrew Publishing, pp. 398–412
Zurück zum Zitat Elmore WC (1969) Physics of waves. McGraw-Hill, New York, p 62 Elmore WC (1969) Physics of waves. McGraw-Hill, New York, p 62
Zurück zum Zitat Kuppusami S, Oskouei RH (2015) Parylene coatings in medical devices and implants: a review. Univers J Biomed Eng 3:9–14CrossRef Kuppusami S, Oskouei RH (2015) Parylene coatings in medical devices and implants: a review. Univers J Biomed Eng 3:9–14CrossRef
Zurück zum Zitat “Membranes.” Introduction to microsystem design, by Werner Karl. Schomburg, Springer Berlin Heidelberg, 2011, pp. 29–52 “Membranes.” Introduction to microsystem design, by Werner Karl. Schomburg, Springer Berlin Heidelberg, 2011, pp. 29–52
Zurück zum Zitat Phan A et al (2017) Design of an optical pressure measurement system for intraocular pressure monitoring. IEEE Sens J 18(1):61–68CrossRef Phan A et al (2017) Design of an optical pressure measurement system for intraocular pressure monitoring. IEEE Sens J 18(1):61–68CrossRef
Zurück zum Zitat Phan A et al (2019) A wireless handheld pressure measurement system for in vivo monitoring of intraocular pressure in rabbits. IEEE Trans Biomed Eng 67(3):931–937MathSciNetCrossRef Phan A et al (2019) A wireless handheld pressure measurement system for in vivo monitoring of intraocular pressure in rabbits. IEEE Trans Biomed Eng 67(3):931–937MathSciNetCrossRef
Zurück zum Zitat Verdu J (2012) “Oxidation and oxygen diffusion.” Oxidative ageing of polymers, ISTE, pp. 93–108 Verdu J (2012) “Oxidation and oxygen diffusion.” Oxidative ageing of polymers, ISTE, pp. 93–108
Zurück zum Zitat Yu L, Kim BJ, Meng E (2014) Chronically implanted pressure sensors: challenges and state of the field. Sensors 14:20620–20644CrossRef Yu L, Kim BJ, Meng E (2014) Chronically implanted pressure sensors: challenges and state of the field. Sensors 14:20620–20644CrossRef
Metadaten
Titel
Investigation of long term drift of an intraocular pressure sensor
verfasst von
Alex Phan
Phuong Truong
Christoph Schade
Aditya Vasan
James Friend
Frank E. Talke
Publikationsdatum
03.01.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
Microsystem Technologies / Ausgabe 6/2021
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-020-05164-2

Weitere Artikel der Ausgabe 6/2021

Microsystem Technologies 6/2021 Zur Ausgabe

Neuer Inhalt