Skip to main content
Erschienen in: Fire Technology 5/2017

23.05.2017

SMART Sprinkler Protection for Highly Challenging Fires—Part 2: Full-Scale Fire Tests in Rack Storage

verfasst von: Yibing Xin, Kyle Burchesky, Jaap de Vries, Harold Magistrale, Xiangyang Zhou, Stephen D’Aniello

Erschienen in: Fire Technology | Ausgabe 5/2017

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

An experimental study was conducted to demonstrate the concept of a new sprinkler protection system using Simultaneous Monitoring, Assessment and Response Technology (SMART). Part I of this study focuses on the system design and function evaluation at the component level. The present work is Part II of the study, focusing on full-scale suppression tests to evaluate the performance of SMART sprinkler technology in protecting rack storage fires. The selected fuel was cartoned unexpanded plastic (CUP) commodity representing an intermediate level of fire hazard. The storage height increased from 3 tiers (9.1 m) to 5 tiers (10.7 m) to 7 tiers (12.2 m) in the three tests. The sprinkler activation was initiated by a smoke detector and a ceiling temperature rise threshold. The fire location was calculated as the thermal centroid based on ceiling temperatures. A group of six sprinklers, closest to the calculated fire location, was activated simultaneously. Subsequent fire development was monitored through visual observation as well as ceiling temperature data. Test results show that the SMART sprinklers can provide adequate protection for the CUP commodities stored up to 7-tiers (12.2-m) high within a rack storage under the tested conditions. The water densities used in these tests were approximately 50% of those in existing protection recommendation. These results lay the foundation for exploring potential applications of the SMART sprinklers to Highly Challenging Fires.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat FM Global (2014) FM global loss prevention data sheets, 8–21—Roll paper storage. Norwood, MA 02062, USA FM Global (2014) FM global loss prevention data sheets, 8–21—Roll paper storage. Norwood, MA 02062, USA
2.
Zurück zum Zitat Xin Y, Burchesky K, de Vries J, Magistrale H, Zhou X, D’Aniello S (2017) SMART sprinkler protection for highly challenging fires—Part 1: System design and function evaluation. Fire Technol. doi:10.1007/s10694-017-0662-2 Xin Y, Burchesky K, de Vries J, Magistrale H, Zhou X, D’Aniello S (2017) SMART sprinkler protection for highly challenging fires—Part 1: System design and function evaluation. Fire Technol. doi:10.​1007/​s10694-017-0662-2
4.
Zurück zum Zitat FM Approvals LLC. (2006) Class Number 2000—Approval standard for automatic control mode sprinklers for fire protection. Norwood, MA 02062, USA FM Approvals LLC. (2006) Class Number 2000—Approval standard for automatic control mode sprinklers for fire protection. Norwood, MA 02062, USA
5.
Zurück zum Zitat Xin Y, Tamanini F (2008) Assessment of commodity classification for sprinkler protection using representative fuels. In: 9th international symposium of fire safety science, pp 527–538. doi:10.3801/IAFSS.FSS.9-527 Xin Y, Tamanini F (2008) Assessment of commodity classification for sprinkler protection using representative fuels. In: 9th international symposium of fire safety science, pp 527–538. doi:10.​3801/​IAFSS.​FSS.​9-527
7.
Zurück zum Zitat FM Global (2011) FM global loss prevention data sheets 8–9—Storage of class 1, 2, 3, 4 and plastic commodities. Norwood, MA FM Global (2011) FM global loss prevention data sheets 8–9—Storage of class 1, 2, 3, 4 and plastic commodities. Norwood, MA
Metadaten
Titel
SMART Sprinkler Protection for Highly Challenging Fires—Part 2: Full-Scale Fire Tests in Rack Storage
verfasst von
Yibing Xin
Kyle Burchesky
Jaap de Vries
Harold Magistrale
Xiangyang Zhou
Stephen D’Aniello
Publikationsdatum
23.05.2017
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 5/2017
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-017-0659-x

Weitere Artikel der Ausgabe 5/2017

Fire Technology 5/2017 Zur Ausgabe