Fire Zone Diagram of Flame-retardant Cables: Ignition and Upward Flame Spread

verfasst von: Qiyuan Xie, Tai Gong, Xinyan Huang

Erschienen in: Fire Technology | Ausgabe 5/2021

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Electrical cable is a common fire risk and hazard, and once ignited, a cable fire can spread to other rooms and floors by following the direction and location of cables. This work investigated the ignition and upward flame spread over the 1-m long cable under a growing heat flux. Results showed that the flame-retardant cables could be easily ignited by a small flame after a weak irradiation (5 kW/m2) if preheated to 70°C. As the external radiation increases, the cable surface temperature increases, and the upward flame spread rate increases significantly. Once the cable surface reaches 240°C, piloted ignition can be achieved. With the combined effect of external heating (> 18 kW/m2) and smoldering, auto-ignition could be achieved once the cable sheath reaches 500 °C. Moreover, flame-retardant cable fire is intense with severe melting, dripping, swelling, and cracking. The falling cracks and dripping flow can form a pool fire to increase the fire hazard. Finally, a new fire-zone diagram with the surface temperature and critical mass flux was proposed to quantify the cable fire hazard. This work provides important information about fire behaviors of the flame-retardant cable under a real fire scene and may guide the design of fire-resistant cables.

Graphical abstract

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
4.
Zurück zum Zitat Campbell R 2019 Home Electrical Fires. National Fire Protection Association (NFPA) Campbell R 2019 Home Electrical Fires. National Fire Protection Association (NFPA)
15.
Zurück zum Zitat Journeaux T, Försth M, Messa S, Kobilsek M, Sundström B, Johansson P et al (2010) CEMAC - CE-marking of cables. SP Rapport NV - 2010:27 Journeaux T, Försth M, Messa S, Kobilsek M, Sundström B, Johansson P et al (2010) CEMAC - CE-marking of cables. SP Rapport NV - 2010:27
22.
24.
Zurück zum Zitat Konno Y, Kobayashi Y, Fernandez-Pello C, Hashimoto N, Nakaya S, Tsue M et al (2020) Opposed-flow flame spread and extinction in electric wires: the effects of gravity, external radiant heat flux, and wire characteristics on wire flammability. Fire Technol 56:131–148. https://doi.org/10.1007/s10694-019-00935-4CrossRef Konno Y, Kobayashi Y, Fernandez-Pello C, Hashimoto N, Nakaya S, Tsue M et al (2020) Opposed-flow flame spread and extinction in electric wires: the effects of gravity, external radiant heat flux, and wire characteristics on wire flammability. Fire Technol 56:131–148. https://​doi.​org/​10.​1007/​s10694-019-00935-4CrossRef
32.
Zurück zum Zitat Quintiere J 1981 Radiant Panel Rate of Flame Spread Apparatus Quintiere J 1981 Radiant Panel Rate of Flame Spread Apparatus
33.
Zurück zum Zitat ISO 5658–2 2006 Reaction to fire tests -- Spread of flame -- Part 2: Lateral spread on building and transport products in vertical configuration. International Organization for Standardization, Geneva ISO 5658–2 2006 Reaction to fire tests -- Spread of flame -- Part 2: Lateral spread on building and transport products in vertical configuration. International Organization for Standardization, Geneva
Metadaten
Titel
Fire Zone Diagram of Flame-retardant Cables: Ignition and Upward Flame Spread
verfasst von
Qiyuan Xie
Tai Gong
Xinyan Huang
Publikationsdatum
22.05.2021
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 5/2021
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-021-01133-x

Weitere Artikel der Ausgabe 5/2021

Fire Technology 5/2021 Zur Ausgabe