Skip to main content
Erschienen in: Experimental Mechanics 4/2007

01.08.2007

Assessment of High Speed Imaging Systems for 2D and 3D Deformation Measurements: Methodology Development and Validation

verfasst von: V. Tiwari, M. A. Sutton, S. R. McNeill

Erschienen in: Experimental Mechanics | Ausgabe 4/2007

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Ultra high-speed and moderate speed image acquisition platforms have been characterized, with special emphasis on the variability and accuracy of the measurements obtained when employed in either 2D or 3D computer vision systems for deformation and shape measurements. Specifically, the type of image distortions present in both single channel cameras (HS-CMOS) and multi-channel image intensified cameras (UHS-ICCD) are quantified as part of the overall study, and their effect on the accuracy of experimental measurements obtained using digital image correlation have been determined. Results indicate that established methods for noise suppression and recently developed models for distortion correction can be used effectively in situations where the primary intensity noise components are characterized by minimal cross-talk and stationary spatial distortions. Baseline uniaxial tension experiments demonstrate that image correlation measurements using high speed imaging systems are unbiased and consistent with independent deformation measurements over the same length scale, with point-to-point strain variations that are similar to results obtained from translation experiments. In this study, the point-to-point variability in strain using the image intensified system is on the order of 0.001, whereas the non-intensified system had variability of 0.0001. Results confirm that high speed imaging systems can be utilized for full field two and three-dimensional measurements using digital image correlation methods.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Fußnoten
1
The UHS-ICCD imaging system used in this study is the Imacon 200 manufactured by DRS Hadland.
 
2
The HS-CMOS imaging system used in this study is the Phantom V7.1 manufactured by Vision Research, Inc.
 
3
The figure provides qualitative information regarding the arrangement of optical and digitization elements within the UHS-ICCD image acquisition system. The actual shape of a component, the number of components, their orientation and spatial relationship relative to other components should not be inferred from the schematic drawing.
 
4
The same randomly selected locations are used in all eight channels.
 
5
Saturation is known to occur for all points with I ≥ 1,023 since no additional range is possible. In this case, the standard deviation is zero.
 
6
Several approaches, including image averaging, domain filtering and homomorphic masking, are developed. When used to correct selected UHS-ICCD images, the results are not encouraging; increases in noise level are observed in some cases and the methods are not pursued further in this study.
 
7
The flat field correction process employed in this study is performed external to the IMACON software using algorithms developed by Correlated Solutions, Incorporated.
 
8
Additional experiments are performed with gain values of 1 and 2, with similar results, indicating that changes in initial conditions for the micro-channel plates did not appreciably alter local variability in the intensity response.
 
9
All 2D image correlation studies are performed using a modified version of VIC-2D, Correlated Solutions, Inc http://​www.​correlatedsoluti​ons.​com.
 
10
Lower spatial resolution in the UHS-ICCD system mandated a larger subset size to have sufficient contrast for accurate image correlation.
 
11
Translation tests performed using shifted copies of the reference image gave correct translation results, confirming that the image correlation algorithms are performing adequately.
 
12
The CMOS sensor has 8 bit quantization. The 8 bit data is scaled to 10 bits for comparison to UHS-ICCD results using the formula \( I_{{{\text{10}}\,\,{\text{bits}}}} = 1024\,{\left( {{I_{{{\text{8}}\,\,{\text{bits}}\,}} } \mathord{\left/ {\vphantom {{I_{{{\text{8}}\,\,{\text{bits}}\,}} } {256}}} \right. \kern-\nulldelimiterspace} {256}} \right)} \), where I8 bits > 16 to minimize effect of dark field differences between systems on the computed variations.
 
13
ICCD data is obtained from Fig. 4 and limited to same range as obtained from the CMOS sensor for comparative purposes.
 
14
Flat-field corrections performed on the Phantom V7.1 images did not decrease scatter in the measured intensity field data.
 
15
Flat field corrected images are used to obtain displacement fields. The results are nearly identical to the results shown in Fig. 10(a), and hence are not reported separately.
 
16
Even though the spatial distortion function does correct for stationary fields, applying the UHS-ICCD distortion fields did not improve the results obtained using flat field correction and shown in Fig. 7. The lack of improvement further demonstrates that image-to-image variability in the pixel intensity values is the primary source of errors in the UHS-ICCD imaging systems.
 
17
The width of the correction region is directly related to the subset size used for the displacement measurements.
 
18
Dead pixels must be removed from the digital image correlation process to eliminate this effect. Highly non-linear response is generally a function of the incident light intensity and hence is not a stationary, spatially varying distortion effect that can be corrected.
 
19
For the same set of experiments, the UHS-ICCD system is unbiased when estimating the whole-field response, with errors in average strain less than 100 micro strain.
 
20
Any significant mismatch between initializing the image acquisition processes in the stereo cameras can result in unacceptable errors in the measurements. When using two UHS-ICCD cameras in a 3D configuration, oscilloscope measurements confirmed that the time delay between trigger pulse for both the cameras is on the order of a few picoseconds, with a maximum difference in camera initialization on the order of ±2.5 ns. For the HS-CMOS systems, the time delay is less than 1 μs. Such small time delays are insignificant for the experiments performed in this study.
 
21
Stereo calibration and 3D image correlation are performed using software developed by Correlated Solutions, Incorporated, http://​www.​correlatedsoluti​ons.​com.
 
22
Results from a series of dynamic events will be reported in a future publication.
 
23
Image sensors integrate the light intensity emanating from points on an object over the specified exposure time.
 
Literatur
1.
Zurück zum Zitat Sutton MA, Wolters WJ, Peters WH, Ranson WF, McNeill SR (1983) Determination of displacements using an improved digital correlation method. Image Vis Comput 4(3):143–150.CrossRef Sutton MA, Wolters WJ, Peters WH, Ranson WF, McNeill SR (1983) Determination of displacements using an improved digital correlation method. Image Vis Comput 4(3):143–150.CrossRef
2.
Zurück zum Zitat Sutton MA, McNeill SR, Jang J, Babai M (1988) The effects of sub-pixel image restoration on digital correlation error estimates. Opt Eng 27(3):173–175. Sutton MA, McNeill SR, Jang J, Babai M (1988) The effects of sub-pixel image restoration on digital correlation error estimates. Opt Eng 27(3):173–175.
3.
Zurück zum Zitat Bruck HA, McNeill SR, Sutton MA, Peters WH (1989) Digital image correlation using Newton Raphson method of partial differential correction. Exp Mech 29:261–267.CrossRef Bruck HA, McNeill SR, Sutton MA, Peters WH (1989) Digital image correlation using Newton Raphson method of partial differential correction. Exp Mech 29:261–267.CrossRef
4.
Zurück zum Zitat Sutton MA, Bruck HA, Chae TL, Turner JL (1990) Development of computer methodology for the analysis of surface deformations in magnified images. ASTM STP-1094 on MICON-90, Advances in video technology for microstructural evaluation of materials, p 109. Sutton MA, Bruck HA, Chae TL, Turner JL (1990) Development of computer methodology for the analysis of surface deformations in magnified images. ASTM STP-1094 on MICON-90, Advances in video technology for microstructural evaluation of materials, p 109.
5.
Zurück zum Zitat Khan-Jetter ZL, Chu TC (1990) Three dimensional displacement measurements using digital image correlation and photogrammic analysis. Exp Mech 30(1):10–16.CrossRef Khan-Jetter ZL, Chu TC (1990) Three dimensional displacement measurements using digital image correlation and photogrammic analysis. Exp Mech 30(1):10–16.CrossRef
6.
Zurück zum Zitat Luo PF, Chao YJ, Sutton MA, Peters WH (1993) Accurate measurement of three dimensional deformable and rigid bodies using computer vision. Exp Mech 33(2):123–132.CrossRef Luo PF, Chao YJ, Sutton MA, Peters WH (1993) Accurate measurement of three dimensional deformable and rigid bodies using computer vision. Exp Mech 33(2):123–132.CrossRef
7.
Zurück zum Zitat Helm J, McNeill SR, Sutton MA (1996) Improved three-dimensional image correlation for surface displacement measurement. Opt Eng 35(7):1911–1920.CrossRef Helm J, McNeill SR, Sutton MA (1996) Improved three-dimensional image correlation for surface displacement measurement. Opt Eng 35(7):1911–1920.CrossRef
8.
Zurück zum Zitat Helm JD, McNeill SR, Sutton MA (1996) Improved 3D Image correlation for surface displacement measurement. Opt Eng 35(7):1911–1920.CrossRef Helm JD, McNeill SR, Sutton MA (1996) Improved 3D Image correlation for surface displacement measurement. Opt Eng 35(7):1911–1920.CrossRef
9.
Zurück zum Zitat Synnergren P, Sjodahl M (1999) A stereoscopic digital speckle photography system for 3D displacement field measurements. Opt Lasers Eng 31:425–443.CrossRef Synnergren P, Sjodahl M (1999) A stereoscopic digital speckle photography system for 3D displacement field measurements. Opt Lasers Eng 31:425–443.CrossRef
10.
Zurück zum Zitat Sutton MA, McNeill SR, Helm JD, Schreier HW, Chao YJ (2000) Photomechanics. Advances in 2D and 3D computer vision for shape and deformation measurement. In: Rastogi PK (ed) Topics in applied physics. Springer Verlag, 77:323–372. Sutton MA, McNeill SR, Helm JD, Schreier HW, Chao YJ (2000) Photomechanics. Advances in 2D and 3D computer vision for shape and deformation measurement. In: Rastogi PK (ed) Topics in applied physics. Springer Verlag, 77:323–372.
11.
Zurück zum Zitat Lu H, Cary PD (2000) Deformation measurements by digital image correlation: implementation of a second order displacement gradient. Exp Mech 40:393–400.CrossRef Lu H, Cary PD (2000) Deformation measurements by digital image correlation: implementation of a second order displacement gradient. Exp Mech 40:393–400.CrossRef
12.
Zurück zum Zitat Cheng P, Sutton MA, Schreier HW, McNeill SR (2002) Full-field speckle pattern image correlation with B-spline deformation function. Exp Mech 42(3):344–352.CrossRef Cheng P, Sutton MA, Schreier HW, McNeill SR (2002) Full-field speckle pattern image correlation with B-spline deformation function. Exp Mech 42(3):344–352.CrossRef
13.
Zurück zum Zitat Sutton MA, Turner YJ, Chao YJ, Bruck HA, Chae TL (1992) Experimental investigation of three-dimensional effects near a crack tip using computer vision. Int J Fract 53:201–228. Sutton MA, Turner YJ, Chao YJ, Bruck HA, Chae TL (1992) Experimental investigation of three-dimensional effects near a crack tip using computer vision. Int J Fract 53:201–228.
14.
Zurück zum Zitat Luo PF, Chao YJ, Sutton MA (1994) Application of stereo vision to 3D deformation analysis in fracture mechanics. Opt Eng 33:981.CrossRef Luo PF, Chao YJ, Sutton MA (1994) Application of stereo vision to 3D deformation analysis in fracture mechanics. Opt Eng 33:981.CrossRef
15.
Zurück zum Zitat Sutton MA, Zhao W, McNeill SR, Helm JD, Riddell WT, Piascik RS (1999) Local crack closure measurements: development and application of a measurement system using computer vision and a far-field microscope. In: Smith K, McDowell J (eds) ASTM STP 1343 on crack closure measurements, pp 145–156. Sutton MA, Zhao W, McNeill SR, Helm JD, Riddell WT, Piascik RS (1999) Local crack closure measurements: development and application of a measurement system using computer vision and a far-field microscope. In: Smith K, McDowell J (eds) ASTM STP 1343 on crack closure measurements, pp 145–156.
16.
Zurück zum Zitat Sutton MA, McFadden C (2000) Development of a methodology for non-contacting strain measurements in fluid environments using computer vision. Opt Lasers Eng 32:367–377.CrossRef Sutton MA, McFadden C (2000) Development of a methodology for non-contacting strain measurements in fluid environments using computer vision. Opt Lasers Eng 32:367–377.CrossRef
17.
Zurück zum Zitat Sutton MA, Zhao W, McNeill SR, Srchreier HW, Chao YJ (2001) Development and assessment of a single-image fringe projection method for dynamic applications. Exp Mech 41(3):205–217.CrossRef Sutton MA, Zhao W, McNeill SR, Srchreier HW, Chao YJ (2001) Development and assessment of a single-image fringe projection method for dynamic applications. Exp Mech 41(3):205–217.CrossRef
18.
Zurück zum Zitat Helm J, Sutton MA, Boone ML (2001) Experimental study of crack growth in thin sheet material under tension–torsion loading. Int J Fract 109:285–301.CrossRef Helm J, Sutton MA, Boone ML (2001) Experimental study of crack growth in thin sheet material under tension–torsion loading. Int J Fract 109:285–301.CrossRef
19.
Zurück zum Zitat Tsai RY (1986) An efficient and accurate camera calibration technique for 3D machine vision. Proceedings of the IEEE International Conference on Computer Vision and Pattern Recognition pp 364–374. Tsai RY (1986) An efficient and accurate camera calibration technique for 3D machine vision. Proceedings of the IEEE International Conference on Computer Vision and Pattern Recognition pp 364–374.
20.
Zurück zum Zitat Tsai RY (1987) A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-self TV cameras and lenses. J Robot Autom RA-3(4):323–345.CrossRef Tsai RY (1987) A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-self TV cameras and lenses. J Robot Autom RA-3(4):323–345.CrossRef
21.
Zurück zum Zitat Faugeras O, Toscani G (1987) Camera calibration for 3D computer vision. International Workshop on Machine Vision and Machine Intelligence, Japan, pp 240–247. Faugeras O, Toscani G (1987) Camera calibration for 3D computer vision. International Workshop on Machine Vision and Machine Intelligence, Japan, pp 240–247.
22.
Zurück zum Zitat Weng J, Cohen P, Hernion M (1992) Camera calibration and distortion model and accuracy evaluation. IEEE Trans Pattern Anal Mach Intell 14:965–980.CrossRef Weng J, Cohen P, Hernion M (1992) Camera calibration and distortion model and accuracy evaluation. IEEE Trans Pattern Anal Mach Intell 14:965–980.CrossRef
23.
Zurück zum Zitat Devy M, Garric V, Orteu JJ (1997) Camera calibration from multiple views of a 2D object using global nonlinear minimization method. International Conference on Intelligent Robots and Systems, France, 3:1583–1589. Devy M, Garric V, Orteu JJ (1997) Camera calibration from multiple views of a 2D object using global nonlinear minimization method. International Conference on Intelligent Robots and Systems, France, 3:1583–1589.
24.
Zurück zum Zitat Zhang Z (1999) A flexible new technique for camera calibration. Technical Report MSR-TR-98-71, Microsoft Research. Zhang Z (1999) A flexible new technique for camera calibration. Technical Report MSR-TR-98-71, Microsoft Research.
25.
Zurück zum Zitat Garcia D, Orteu JJ, Devy M (2000) Accurate calibration of a stereovision sensor: comparison of different approaches. 5th Workshop on Vision Modeling, and Visualization, Germany, pp 25–32. Garcia D, Orteu JJ, Devy M (2000) Accurate calibration of a stereovision sensor: comparison of different approaches. 5th Workshop on Vision Modeling, and Visualization, Germany, pp 25–32.
26.
Zurück zum Zitat Heikkilä J (2000) Geometric camera calibration using circular control points. Pattern Anal Mach Intell 22(10):1066–1077.CrossRef Heikkilä J (2000) Geometric camera calibration using circular control points. Pattern Anal Mach Intell 22(10):1066–1077.CrossRef
27.
Zurück zum Zitat Yu W (2004) Image-based lens geometric distortion correction using minimization of average bicoherence index. Pattern Recognition 37:1175–1187.CrossRef Yu W (2004) Image-based lens geometric distortion correction using minimization of average bicoherence index. Pattern Recognition 37:1175–1187.CrossRef
28.
Zurück zum Zitat McNeill SR, Sands R, Tiwari V, Sutton MA (2004) Digital Image Correlation Measurement Error Considerations in Ultra-high Speed Imaging, ICEM12—12th International Conference on Experimental Mechanics, Politecnico di Bari, Italy, pp 188–189. McNeill SR, Sands R, Tiwari V, Sutton MA (2004) Digital Image Correlation Measurement Error Considerations in Ultra-high Speed Imaging, ICEM12—12th International Conference on Experimental Mechanics, Politecnico di Bari, Italy, pp 188–189.
29.
Zurück zum Zitat Tiwari V, Williams S, Sutton MA, McNeill SR (2005) Application of digital image correlation in impact testing. SEM Annual Conference pp 413–414. Tiwari V, Williams S, Sutton MA, McNeill SR (2005) Application of digital image correlation in impact testing. SEM Annual Conference pp 413–414.
30.
Zurück zum Zitat Schreier HW, Garcia D, Sutton MA (2004) Advances in light microscope stereo vision. Exp Mech 44(3):278–288.CrossRef Schreier HW, Garcia D, Sutton MA (2004) Advances in light microscope stereo vision. Exp Mech 44(3):278–288.CrossRef
31.
Zurück zum Zitat Brown DC (1971) Lens distortion for close-range photogrammetry. Photometric Engineering 37(8):855–866. Brown DC (1971) Lens distortion for close-range photogrammetry. Photometric Engineering 37(8):855–866.
32.
Zurück zum Zitat Beyer HA (1992) Accurate Calibration of CCD-cameras. In: Proceedings of the International Conference on Computer Vision and Pattern Recognition (CVPR’92), Urbana-Champaign IL, June, pp 96–101. Beyer HA (1992) Accurate Calibration of CCD-cameras. In: Proceedings of the International Conference on Computer Vision and Pattern Recognition (CVPR’92), Urbana-Champaign IL, June, pp 96–101.
33.
Zurück zum Zitat Weng J, Cohen P, Herniou M (1992) Camera calibration with distortion models and accuracy evaluation. IEEE Trans Pattern Anal Mach Intell 14:965–980.CrossRef Weng J, Cohen P, Herniou M (1992) Camera calibration with distortion models and accuracy evaluation. IEEE Trans Pattern Anal Mach Intell 14:965–980.CrossRef
34.
Zurück zum Zitat Peuchot B (1993) Camera virtual equivalent model 0.01 pixel detector. Proceedings of Computerized Medical Imaging and Graphics 17:289–294.CrossRef Peuchot B (1993) Camera virtual equivalent model 0.01 pixel detector. Proceedings of Computerized Medical Imaging and Graphics 17:289–294.CrossRef
35.
Zurück zum Zitat Brand R, Mohr P, Bobet P (1994) Distorsions optiques: corrections dans un mode’le projectif. Proceedings of 9th Congress AFCET, Reconnaissances des Formes et Intelligence Articielle (RFIA’94) in January in Paris, France, pp 87–98. Brand R, Mohr P, Bobet P (1994) Distorsions optiques: corrections dans un mode’le projectif. Proceedings of 9th Congress AFCET, Reconnaissances des Formes et Intelligence Articielle (RFIA’94) in January in Paris, France, pp 87–98.
Metadaten
Titel
Assessment of High Speed Imaging Systems for 2D and 3D Deformation Measurements: Methodology Development and Validation
verfasst von
V. Tiwari
M. A. Sutton
S. R. McNeill
Publikationsdatum
01.08.2007
Erschienen in
Experimental Mechanics / Ausgabe 4/2007
Print ISSN: 0014-4851
Elektronische ISSN: 1741-2765
DOI
https://doi.org/10.1007/s11340-006-9011-y

Weitere Artikel der Ausgabe 4/2007

Experimental Mechanics 4/2007 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.