3.1 Chemical properties of the virgin (VF) and recycled fibres (RF)
The pH values of the fibres were measured after three different time spans but the differences for each fibre type were so low that only the average value was reported (Table
3). While the pH value of VF amounted to 4.0, those of RF were on average 4.9 and 5.2 after each recycling process, respectively. The slightly higher pH values of the RF may be due to the formation of ammonia due to the breakdown of the UF-resin, which reacts to alkaline ammonium hydroxide in water (Roffael and Hüster
2012; Wan et al.
2014). Roffael et al. (
2009) assumed, that the highly increased pH value of the RF (6.3) in their study also enhances the cleavage of acetyl groups in hemicelluloses and subsequently of the glycosidic bonds.
Table 3
Chemical properties of the virgin fibres (VF) and recovered fibres (RF). Equal letters within a property indicate that there is no statistical difference between the fibre types
Virgin fibres | Non-milled | 4.0a | 1.8a | 8.6a | 0.07a | 0.2a | n.a |
milled | 4.0a | 2.0a | 10.0a | 0.07a | 0.2a | n.a |
RF 1 | 10 mm | Non-milled | 4.8c | 50.5b | 595.0b | 1.1b | 3.5b | 35.0 |
milled | 4.8bc | 61.3b | 557.0b | 1.0b | 3.2b | 32.0 |
16 mm | Non-milled | 4.9 | 51.0c | 465c | 1.2b | 3.8b | 38.0 |
milled | 5.2d | 62.9c | 517.0c | 1.1b | 3.5b | 35.0 |
RF 2 | 10 mm | Non-milled | 5.3b | 61.2b | 617b | 2.2c | 7.0c | 51.8 |
milled | 5.0 | 79.5b | 629.0b | 2.5c | 8.0c | 59.2 |
16 mm | Non-milled | 5.4d | 75.5c | 617.0c | 2.2c | 7.0c | 54.6 |
milled | 5.4d | 68.0c | 561.0c | 1.9c | 6.1c | 47.6 |
Formaldehyde emission of the VF after 3 h was 1.8 and 2.0 mg per kg oven-dried fibres for non-milled and hammer-milled samples, respectively, without significant difference (Table
3). Each recycling process increased the formaldehyde emissions of the RF. In addition, the hammer-milling process further increased the emission, except after hammer-milling of second-time recycled RF of 16 mm panels. The 24 h formaldehyde emission of non-milled and hammer-milled samples VF were again the same resulting in 8.6 and 10.0 mg per kg oven-dried fibres, respectively.
Virgin fibres’ NC of 0.07% is in accordance with Cowling and Merrill (
1966), who reported that wood contains approximately 0.1% nitrogen; Lubis et al. (
2018a) found 0.5% nitrogen in VF. While the NC of the VF was negligibly low, the NC of the RF amounted to approximately 1% after the first and 2% after the second disintegration process (Table
3). As the NC of the virgin MDF panels was approximately 3% (Table
4), this indicates that about 33.5% of the UF binder remained on the first-generation RF and 53.4% on the second- generation RF (related to the virgin panels).
Table 4
Chemical properties of virgin and recycled MDF panels. Asterisks and equal letters within a property indicate that there is no statistical difference between the MDF panels throughout the different generations
1st generation | 10 mm | 17.2 | 14.8a | 12.2a | 162a | 3.1a | 10.0a |
16 mm | 17.7 | 14.5d | 12.0c | 163d | 3.1a | 10.0a |
2nd generation | 10 mm | Recycled | 15.2ad | 10.9 | 9.3b | 209b | 4.2 | 13.5 |
Reference | 15.1ace | 12.3 c | 10.0b | 182abc | 3.2a | 10.4a |
16 mm | Recycled | 13.7f | 11.2e | 8.8d | 114e | 4.0 | 12.8 |
Reference | 16.2 | 10.9e | 9.6de | 135ef | 3.0a | 9.9a |
3rd generation | 10 mm | Recycled | 13.4be | 12.9bc | 9.6b | 148c | 5.4 | 17.3 |
Reference | 14bcd | 13.6abc | 13.6ab | 173a | 3.2a | 10.3a |
16 mm | Recycled | 11.6 | 13.9d | 10.3e | 136df | 4.9 | 15.7 |
Reference | 14.3f | 13.4de | 12.7c | 180def | 3.1a | 9.9a |
3.2 Physico-mechanical and chemical properties of the MDF panels
MDF produced from RF exhibited slightly higher densities than the target density and respective reference panels (Table
5). Even though, the IB of the second-generation panels was identical to that of the first-generation and corresponding reference panels. Moreover, the IB of the third-generation 10 mm MDF panels showed 64.5% increment (at slight density increase of 3.8%), while 16 mm MDF panels showed 89.5% increment (the density increased by 4.0%) compared to corresponding first-generation panels. In addition to the slightly increased density that may affect IB (Wong et al.
2000; Hong et al.
2017,
2020), the main reason for the higher IB might be the increasing amount of adhesive that remains on the fibres after recycling, as previously reported (Roffael et al.
2002,
2010a; Lykidis and Grigoriou
2008; Bütün et al.
2018,
2019; Lubis et al.
2018b). On the other hand, Roffael et al. (
2016) reported that the substitution of VF by 100% RF decreased the IB of the new MDF significantly. This might be due to strength loss of the recycled fibres and the over proportional consumption of adhesive by fines, which occurs more in recycled MDF. Moreover, a slight reduction in fibre length, which may occur during recycling as reported elsewhere (F.Y.B.B., unpublished data 2020), might explain higher IB. Shorter fibres may result in a larger surface area for enhanced adhesion. In addition, short fibres can strengthen the structure of the MDF by filling the voids between the large fibres, while aligning themselves along the forming direction (Back
1987). Correspondingly, Groom et al. (
2002) suggested that there is an optimal ratio of fines (shorter fibres) to larger fibres, where the fines provide a greater degree of bonding. Shortening of fibres, however, reduces flexural strength (Myers
1983; Ye et al.
2007) but a reduction in MOR and MOE was hardly observed (Table
5). On the other hand, flexural strength (MOR) and MOE of recovered MDF panels (10 mm thickness) were not significantly different despite increasing density (on average 3% related to first-generation panels) throughout the different generations. Furthermore, repeated recycling of 16 mm MDF panels resulted in rather fluctuating results in terms of bending strengths, which were not significant and were attributed to fluctuations in the production process. In terms of MOE, 16 mm MDF showed similar trends except for a 5.8% decrement for the third-generation panels in comparison to the corresponding reference panels, instead of an increment.
Table 5
Physico-mechanical properties of virgin and recycled MDF panels. Asterisks and equal letters within a property indicate that there is no statistical difference between the MDF panels throughout the different generations
1st generation | 10 mm | 727a | 0.31a | 30.4* | 2992* | 68.6a | 19a |
16 mm | 742c | 0.19c | 30.6a | 3310a | 62.6c | 17.3d |
2nd generation | 10 mm | Recycled | 743b | 0.34ab | 29.6* | 3020* | 77.8b | 17.1 |
Reference | 739ab | 0.22 | 32.2* | 3447* | 76.4ab | 20.4abc |
16 mm | Recycled | 766d | 0.23d | 32.3ac | 3536c | 71.2d | 18.6eg |
Reference | 773d | 0.19 cd | 34.9c | 4019d | 53.6ce | 16.2de |
3rd generation | 10 mm | Recycled | 756b | 0.51 | 28.5* | 2750* | 73.7b | 19.8c |
Reference | 717b | 0.39b | 28.6* | 2974* | 75.6ab | 21.2b |
16 mm | Recycled | 773d | 0.36 | 35.2bc | 3451abcd | 71.5d | 19.5f |
Reference | 747c | 0.20 cd | 34bc | 3667bc | 54.2e | 16.8dfg |
Thickness swelling (TS) of the MDF panels after 24 h immersion in water progressed differently to the water uptake (WU) (Table
5). The second-generation 10 mm panels showed 16% and 10% reduced TS compared to the corresponding reference and first-generation panels, respectively. TS of third-generation 10 mm panels was same as the corresponding reference and first-generation panels. Recycled 16 mm MDF, on the other hand, showed constantly higher TS throughout the generations in comparison to the corresponding reference and first-generation panels. The WU of the MDF after 24 h immersion did not exhibit significant differences between 10 mm second- and third-generation panels and their corresponding reference panels, but significantly higher values when compared to the first-generation panels (Table
5). The WU of 16 mm panels were identical between second- and third-generation panels. The recycled 16 mm panels showed higher water uptake than the first-generation and the reference panels. Higher WU and TS values of the recycled MDF panels are usually attributed to the poor adhesion of the panels, which can be detected by lower IB. In this study, even though the IB increased throughout the repeated recycling processes, the WU and TS increased after recycling. Moezzipour et al. (
2018) assumed the removal of the lignin as a reason; however, this is unlikely for the present study due to neutral pH value and a relatively moderate temperature during disintegration. A possible reason for higher WU and TS might be the increased availability of hygroscopic low-molecular-weight sugars and of fines, which might act like wicks. In contrast to the present findings, Roffael et al. (
2016) observed reduced WU and TS when VF were substituted with 33% RF. They attributed this improvement to the reactivation of the sizing agent (water repellent) contained in the recycled industrial waste MDF and cross-linking of the RF by free formaldehyde in the UF resin. Virgin panels in the present study, however, did not contain sizing agents. In addition, the higher amount of adhesive in the recovered MDF and the resulting increase in IB might explain the stable water-related properties between the 2nd and the 3rd generation of the recycled panels.
Urea, ammonia and oligomeric decay products of UF resin can react with formaldehyde and act as formaldehyde scavengers. Thus, various studies reported significantly reduced formaldehyde content and emission of the recycled MDF (Roffael et al.
2010b;
2016; Behn
2018). Similarly, the formaldehyde emission determined by perforator method of the recycled panels was lower than that of virgin panels throughout the different generations of this study. However, formaldehyde emission results assessed by the gas analysis and flask method did not follow the same trend.
The formaldehyde emission determined by perforator method of the MDF revealed different trends depending on the panel thicknesses (Table
4). Still, regarding both thicknesses, the first-generation panels displayed a significantly higher formaldehyde emission compared to the later generations and their reference panels and the subsequent recycling further decreased the formaldehyde emission of the recycled panels. Recycled 10 mm panels had an identical formaldehyde emission to their reference panels. However, 16 mm recycled panels exhibited significantly lower formaldehyde emission of 15.4% (second-generation) and 18.8% (third-generation) compared to their corresponding reference panels. Likewise, formaldehyde emission assessed by gas analyser showed different trends depending on the panel thicknesses. Again, the formaldehyde emission of the first-generation panels was significantly higher than that of the subsequent generations and their reference panels. Formaldehyde emissions of both thickness-type panels were lower after the subsequent recycling processes, while that of 10 mm panels was always lower in comparison to their corresponding reference panels. Panels of 16 mm thickness showed the opposite tendency with slightly but not significantly higher formaldehyde emission values compared to their reference panels.
Formaldehyde emission after 3 h assessed by the flask method also revealed similar trends to the ones observed by perforator and gas analysis methods; first-generation panels released significantly higher emissions than the subsequent generations and their reference panels. Furthermore, the 10 mm recycled and respective reference panels displayed identical formaldehyde emission after 3 h. Similarly, 16 mm recycled panels and second-generation reference panels were identical in terms of 3 h formaldehyde emission. Reduction in formaldehyde emissions due to recycling is in contrast to increasingly higher emissions of the RF. This might be explained by the fact that the decay products of UF resin (urea, ammonia and oligomers) in the RF material are able to react with formaldehyde and act as formaldehyde scavengers.
Interestingly, the formaldehyde emissions during 24 h measured by flask method resulted in a different tendency to other related methods. When compared to the first-generation panels, 10 mm and 16 mm recycled panels showed unequal trends; emission of 10 mm second-generation panels was 22.5% (significantly) higher compared to the first-generation panels, while that of third-generation panels was 8.6% lower. The formaldehyde emission of second-generation 16 mm panels, however, was 30.1% and that of third-generation panels 16.5% lower than the first-generation panels. Both in second and third generations, however, 16 mm recycled panels were not significantly different from their reference panels. Compared to the previous studies (Dix et al.
2001a,
b; Schoo et al.
2003; Roffael et al.
2010a), the rather milder conditions (lower temperature and/or shorter duration) might result in a lower breakdown of the UF resin during the thermo-hydrolytic disintegration. Thus, the slight increment in the formaldehyde emission of the third-generation panels can be due to the higher amount of remaining non-hydrolysed UF-binder, even though, these values were always lower than the first-generation panels, except the 24 h flask method results for 10 mm second-generation MDF panels.
The nitrogen content (NC) of the first-generation and reference MDF panels amounted to 3.1% and indicate that the targeted 10% UF resin content was reached. NC was determined as an indicator for the UF content of the recycled panels. It exhibited a constant increment after the subsequent recycling processes, while these values were the same for the first-generation and reference panels irrespective of the panel thicknesses. As a result of the remaining UF binder on the RF (33.5% in RF1 and 53.4% in RF2), the NC increased by 35.4% and 74.2% related to virgin panels for 10 mm recycled panels and by 29.0% and 58.0% for 16 mm recycled panels after each disintegration process, respectively.
A possible explanation for the inconsistent physico-mechanical and fluctuation of chemical results between 10 and 16 mm panels may be attributed to the natural variability of the wood quality along with the limitations of the laboratory-scale production of them.
3.3 Chemical characteristics of the disintegration water (DW)
The pH values of the DW were increased from 4.5 to 5.1 over the various disintegration runs (Table
6). The formaldehyde content in the DW after the first disintegration process was 249.5 mg l
−1 and 342.3 mg l
−1 after recycling of the 10 mm and 16 mm first-generation panels, respectively. An increment of 11.0% was observed after the subsequent recycling of the 10 mm second-generation MDF panels, while 33.4% decrement occurred after the recycling of the 16 mm second-generation panels.
Table 6
Chemical properties of the disintegration water (DW) obtained after the disintegration processes compared to the demineralised water
pH | 4.5 | 4.7 | 5.0 | 5.1 | 5.2 |
Formaldehyde content (mg l−1) | 249.5 | 342.3 | 277.0 | 227.8 | n. a |
Reducing sugars and equivalents (mg l−1) | 7.0 | 6.2 | 0.6 | 0.8 | 0.2 |
Nitrogen content (%) | 0.4 | 0.47 | 0.43 | 0.44 | < 0.003 |
Calculated UF content (%) | 1.2 | 1.5 | 1.4 | 1.4 | n. a |
Significant levels of reducing sugar equivalents (6–7 mg l
−1) were detected in the DW after the first disintegration process. These might originate mainly from hemicelluloses, which were cleaved during the production (pulping) of VF or from panel recycling. During these processes, cleavage of acetyl groups may occur followed by cleavage of glycosidic bonds mainly of hemicelluloses. After the second disintegration process, however, the amounts of reducing sugar equivalents in DW were lower than 1 mg l
−1 showing 91.4% and 87.0% decrement for 10 mm and 16 mm panels, respectively (Table
6). This indicates that the first disintegration process already removed most of the extractable sugars. The reason, why the pH values of the DW obtained after the first disintegration process, is acidic, is that the VF exhibit a pH value of 4.0 (Table
3) due to formation of acetic acid during pulping. During the second disintegration process, the pH values of DW was higher, but still below that of demineralised water.
The NC of the DW obtained after the disintegration of the second-generation 10 mm panels was slightly higher (7.0%) than after the previous disintegration. Meanwhile, 16 mm panels had a slightly lower (6.4%) NC in DW obtained after the second disintegration. Based on the assumption that each kilo of RF material absorbs ca. 2 L of water, on average, approximately 65% and 50% of the initial UF was found in the DW samples from the 1st and the 2nd disintegration process, respectively. The NC of a specific recycled MDF should be roughly the sum of the NC of the used RF and ca. 3.1% nitrogen, which derives from the 10% targeted UF resin. The difference between the total NC of the recycled boards and the NC of DW and RF combined is attributed to evaporation (Hagel and Saake
2020) during draining of the DW and/or during the RF drying.