Abstract

Based upon theory, wall shear stress (WSS), an important determinant of endothelial function and gene expression, has been assumed to be constant along the arterial tree and the same in a particular artery across species. In vivo measurements of WSS, however, have shown that these assumptions are far from valid. In this survey we will discuss the assessment of WSS in the arterial system in vivo and present the results obtained in large arteries and arterioles. In vivo WSS can be estimated from wall shear rate, as derived from non-invasively recorded velocity profiles, and whole blood viscosity in large arteries and plasma viscosity in arterioles, avoiding theoretical assumptions. In large arteries velocity profiles can be recorded by means of a specially designed ultrasound system and in arterioles via optical techniques using fluorescent flow velocity tracers. It is shown that in humans mean WSS is substantially higher in the carotid artery (1.1–1.3 Pa) than in the brachial (0.4–0.5 Pa) and femoral (0.3–0.5 Pa) arteries. Also in animals mean WSS varies substantially along the arterial tree. Mean WSS in arterioles varies between about 1.0 and 5.0 Pa in the various studies and is dependent on the site of measurement in these vessels. Across species mean WSS in a particular artery decreases linearly with body mass, e.g., in the infra-renal aorta from 8.8 Pa in mice to 0.5 Pa in humans. The observation that mean WSS is far from constant along the arterial tree implies that Murray’s cube law on flow-diameter relations cannot be applied to the whole arterial system. Because blood flow velocity is not constant along the arterial tree either, a square law also does not hold. The exponent in the power law likely varies along the arterial system, probably from 2 in large arteries near the heart to 3 in arterioles. The in vivo findings also imply that in in vitro studies no average shear stress value can be taken to study effects on endothelial cells derived from different vascular areas or from the same artery in different species. The cells have to be studied under the shear stress conditions they are exposed to in real life.

1 Introduction

During left ventricular ejection the blood expelled into the arterial system exerts hemodynamic forces on the artery wall. The luminal side of the artery wall is subjected to a pressure pulse, i.e., the difference between diastolic and systolic blood pressure, and a tangential stress exerted by the flowing blood. The pressure pulse distends the artery wall, resulting in radial and circumferential wall strain, i.e., the systolic increase in diameter and cross-sectional area relative to the end-diastolic level, respectively. The radial strain compresses the artery wall during systole [36]. Besides, the pressure pulse generates an axial stress, but not necessarily an axial strain. The tangential stress is known as wall shear stress (WSS). It can be estimated as the product of wall shear rate (WSR) and local blood viscosity, WSR being defined as the radial derivative of blood flow velocity distribution at the wall.
These biomechanical forces are important determinants of endothelial cell function. By modifying the production of vasoactive mediators by endothelial cells, WSS regulates arterial diameter [6, 14, 23, 44], while WSS, and radial and circumferential strain are determinants of endothelial gene expression [10, 11, 16, 34, 42]. Endothelial genes can be transiently or more permanently up-regulated by shear stress [60]. The studies on the effect of shear stress on endothelial gene expression are mostly performed in vitro. In these experiments the level of shear stress applied is generally calculated based upon Poiseuille’s law, while WSS is assumed to be constant along the arterial tree, as predicted by theory, and to be about the same in a particular artery across species. Thus endothelial cells are exposed to average calculated shear stress values, no matter the area or the species they are derived from.
In vivo measurements in arterioles [2, 31, 46, 50] and large arteries [48], however, have shown that mean WSS is neither constant along the arterial tree in a particular species, nor the same in a particular artery across species [18]. These findings have shed new light on our concepts regarding the arterial system, among which, the flow-diameter relations at bifurcations, and do have consequences for the in vitro studies on shear stress and endothelial gene expression.
In this survey, we will discuss the assessment of WSS in the arterial system in vivo and present the results obtained in large arteries and arterioles. The consequences of these findings, especially regarding the concept of the flow-diameter relations in bifurcations along the arterial tree, will be addressed.

2 Determination of WSS in vivo

2.1 In arterioles

2.1.1 Direct assessment

In cat mesenteric arterioles WSS was determined by means of micropressure measurements upstream and downstream, and length and diameter measurements [31]. Measurements of micro pressure in vivo, however, need a lot of skill and can only be realized in a limited number of experienced centers. Pries and Secomb [46] used a similar approach to determine WSS in rat mesenteric arterioles, but to circumvent micro pressure measurements they computed the pressure differences along arteriolar segments using a mathematical model [47].
Bakker and colleagues [2] determined shear stress in rat cremaster muscle arterioles from length, diameter and viscosity measurements, assuming the presence of Poiseuille flow.

2.1.2 Assessment from velocity profiles

In arterioles optical techniques are employed, using fluorescent particles as velocity tracers. In this approach, pairs of flashes of light provide in a single video field two images of the same tracer displaced over a certain distance for the given interval between the flashes. The time interval between the two flashes is selected so that the concomitant images of the tracer show no or only little overlap. To construct velocity profiles, i.e., the velocity distribution over the cross-sectional area of the vessel, the centroids of the images of the tracers are identified and the displacement of the tracer in the preset time interval, yielding its velocity, and its relative radial position in the vessel are measured. By using sequences of illumination at a preset delay with respect to the ECG reference, systolic and diastolic velocity profiles can be determined. Originally, fluorescently labeled blood platelets were used as velocity tracers [58]. With these tracers no data points could be obtained closer to the wall than 0.5 μm due to their physical size [13] and their orientation [59]. In more recent years nanometer particles are in use as velocity tracers [32, 61]. Because of their smaller size (0.4–0.5 μm in diameter), flow velocities can be determined as close to the wall as about 0.2 μm. Originally the velocity of the tracers and their position were determined by hand, a time-consuming procedure, but recently a computerized two-dimensional correlation technique has been developed to assess displacement and position of the tracers [61].
The experimentally determined velocity profiles can be adequately described by a modification [58] of the equation as originally described by Roevros [52]:
$$ v(r) = v_{{\max }} {\left( {1 - {\left| {a\frac{r} {R} + b} \right|}^{K} } \right)},\quad a > 0, $$
(1)
where v(r) is the flow velocity at the radial position r, the vertical lines denote absolute values, v max is the maximal center stream flow velocity in the vessel, R is the radius of the vessel, a is a scale factor allowing a non-zero intercept of the fit with the vessel wall, b is a parameter correcting for a shift of the top of the profile away from the vessel center (note that a and b are interrelated) and K describes the degree of flattening of the profile. K = 2 for a fully developed parabolic velocity profile; K will be higher the flatter the velocity profile is.
The platelet velocity profiles as described in this way are flattened parabolas in systole as well as in diastole [50, 58] with K factors varying between 2.3 and 4. Flattening of the profile is also indicated by the ratio of maximum and mean velocity of the profile, ranging from 1.39 to 1.54.This ratio is 2 in case of a parabolic profile. Differences in WSR at opposite walls may have to be appreciated due to asymmetry of the velocity profiles [57].
A least estimate of WSR can be obtained by determining the best fit through the measured velocity profile with the use of Eq. (1) and a linear extrapolation from the point closest to the wall, where velocity can be measured to zero flow at the wall [57]. Because in arterioles the velocity tracers are approaching the vessel wall closely, plasma viscosity, which can be accurately determined in vitro by means of glass capillary viscometry systems, is used to convert WSR to WSS.

2.2 In large arteries

2.2.1 Assessment from velocity profiles

Velocity profiles in large arteries can be recorded non-invasively by means of MRI [15, 40, 41, 55] and non-invasive ultrasound. In our studies the latter technique is used, because of its better spatial, and especially, temporal resolution [48].
To accurately determine velocity profiles in vivo, precise measurement of low blood flow velocities close to the vessel wall is required. This can only be achieved when the high amplitude low frequency signals reflected by the artery wall are adequately suppressed without losing the low blood flow velocity information near the wall. This can be accomplished by considering the time-dependent aspects of the reflections and using a band stop filter which adapts its rejection range to the mean frequency of the reflections from the artery wall [4]. In this adaptive filtering technique these reflections are suppressed by shifting the temporal frequency distribution toward zero frequency, the shift being given by the estimated mean frequency of the reflected signal. Subsequently, the reflections, then centered around zero frequency, are selectively suppressed by a high-pass filter with a low cut-off frequency.
To assess WSR, a conventional 2-D imager (Mark 9 HDI, ATL, Bothell, Washington, USA) with a C9-5 curved array is combined with dedicated signal processing to measure the blood flow velocity distribution along a selected line of observation across the center of the artery. After localization of the region of interest, the system is switched to a single line of observation (Motion mode; M-mode) with short emission bursts (2 periods) to retain spatial resolution and a high pulse repetition frequency to facilitate blood flow velocity detection. The radio frequency (RF) signals are captured at a sample rate of 20 MHz and stored on a computer for off-line analysis. After automatic identification of the wall-lumen interfaces, cursors, representing sample volumes, are positioned on the reflections from the anterior and posterior walls [35]. The time-dependent blood flow velocity distribution is obtained with the use of a modeled cross-correlation function applied to short segments of RF data between the cursors after suppression of the wall signals with an adaptive high pass filter. Calculation of mean blood flow velocity for all RF segments provides a time-dependent velocity profile (Fig. 1). The length of the RF segments is selected according to the actual bandwidth of the RF signals (2.5 MHz) and corresponds to 300 μm in depth; the segments are spaced at 150-μm intervals (50% overlap). For further details regarding this ultrasound technique the reader is referred to previous publications of our group [3, 4, 20].
Using a similar analysis of profile shape as in arterioles, it could be demonstrated that in the common carotid artery the velocity profile is substantially flattened (Fig. 1) with a K factor of 4 in systole [8]. The systolic velocity profile is also flattened in the femoral artery [55]. In the brachial artery, however, the K factor was found to be 2.1 in systole [8], indicating that the velocity profile in this artery is close to parabolic [55]. The difference in shape of the velocity profile between the carotid and the brachial artery can likely be explained by the greater relative distension of the former artery [8, 43] and a relatively longer entrance length in the latter. The smaller diameter of the brachial artery, relative to the resolution of the ultrasound system, may contribute to the more parabolic profile measured in this vessel.
In the ultrasound systems presently in use, the shear rate distribution in an artery is derived from the radial derivative of the velocity profile at each site and each time instant (Fig. 2). Because blood flow velocities cannot be determined at the wall, the maximum value of the radial derivative of the velocity profile is considered as the estimate of instantaneous WSR [3, 20]. From the shear distribution mean WSR, the time-averaged shear rate over one cardiac cycle, and peak WSR, the value at peak systole, can be determined. When interested in WSR values in a particular artery in general, the values recorded near the anterior and the posterior walls are averaged to minimize the influence of skewness of the velocity profile and of secondary flows. In studies on the relation between WSR and artery wall structure, the shear rate values as assessed locally are used.
In large arteries whole blood viscosity (WBV), which can be determined by using the approximation proposed by Weaver et al. [62], is used to calculate WSS:
$$ \log ({\text{WBV}}) = \log (\eta _{0} ) + (0.03 - 0.0076\log (\gamma )){\text{Ht}}, $$
(2)
where η o is plasma viscosity, γ is WSR and Ht is hematocrit.
Under the shear rate conditions found in large arteries in vivo [48], the effect of changes in plasma viscosity on this estimation of WBV is negligible [8], leaving shear rate and hematocrit as the relevant parameters. In vitro WBV can be determined by means of a cone plate viscometer. The viscosity determined in this way, however, may lead to too high estimates of WBV, because it cannot be measured at appropriate and sufficiently high shear rates in all subjects studied [17].

3 WSS data obtained in vivo

3.1 In arterioles

The average WSS in mesenteric arterioles was found to be 1.82 Pa, with a range of 0.51–5.0 Pa, in rabbits [50], 4.71 ± 2.34 Pa (mean ± SD) in cats [31] and around 5 Pa, with a substantial variation, in rats, at least in arterioles larger than 15 μm in diameter [46]. In smaller arterioles, WSS rapidly increased to above 10 Pa in arterioles with a diameter of 6 μm [46]. The wide variation in WSS values found in these studies can likely be explained by the non-regulatory properties of mesenteric arterioles [5]; variations in blood flow velocity are not or inadequately compensated for by a change in arteriolar diameter. Besides, differences in anesthesia and variations in the site of measurement along the arterioles have to be considered.
Shear stress in the first order arterioles of rat cremaster muscle was found to be 3 ± 0.5 Pa (mean ± SEM) in the proximal part and 2.1 ± 0.5 Pa in the more distal part [2].

3.2 In large arteries

3.2.1 In humans

In human arteries mean WSS is far from constant along the arterial tree as predicted by theory (Table 1). In the common carotid artery of presumed healthy volunteers, mean WSS was found to vary on the average between 1.1 and 1.4 Pa in the different study populations [48], values within the limits of the theoretically predicted value of 1.5 Pa ± 50%. Mean WSS is substantially lower in muscular conduit arteries of presumed healthy volunteers, reaching average values in the common femoral artery, the superficial femoral artery and the brachial artery varying between 0.3 and 0.4 Pa, around 0.5 Pa and varying between 0.4 and 0.5 Pa, respectively (Table 1).
Table 1
Average mean wall shear stress (Pa) in the common carotid (CCA), common (CFA) and superficial femoral (SFA) and brachial (BA) arteries at rest in healthy volunteers
 
Men
Women
Young
Old
Young
Old
CCA
1.3
1.2
1.2
1.1
CFA
0.4
0.3
SFA
0.5
0.5
BA
0.5
0.5
0.4
0.5
Derived from Reneman et al. [48]
The lower mean WSS in these conduit arteries at rest likely results from the high peripheral resistance in these vessels, reducing mean volume flow and inducing reflections. In the femoral artery, adaptation of the peripheral resistance during vasodilatation results in mean WSS values close to those in the common carotid artery [25]. Based upon these observations it may be concluded that at rest, mean WSS is regulated locally and depends on the characteristics of the peripheral circulation. Mean WSS will be higher in the absence of reflections, as in the brain circulation, and lower when reflections are dominantly present as in the arm and leg circulations at rest.
Mean shear stress in normal coronary arteries, as derived from intra-coronary velocity measurements and coronary angiography, assuming Poiseiulle flow, was found to be on the average 0.68 Pa (range 0.33–1.24 Pa) [12].
Peak WSS is not significantly different along the arterial tree, varying between 2.5 and 4.3 Pa in the common carotid artery, between 3.4 and 4.0 Pa in the femoral arteries and between 2.7 and 3.9 Pa in the brachial artery in the populations studied [48].
In humans, mean WSS also varies within artery bifurcations. At rest, mean WSS was found to be significantly lower in the common than in the superficial femoral artery; the former artery seeing reflections from both the superficial and the deep femoral artery, resulting in a longer-lasting negative flow during diastole in the common femoral artery [25]. Peak WSS is not significantly different between these arteries [25]. In the common carotid artery mean WSR, and, hence, mean WSS, was found to be lower near the bifurcation than about 3 cm more proximally. This can likely be explained by the influence of reflections from the external carotid artery at the former site, which has greatly disappeared at the latter site [27]. It is of interest to note that in both the femoral [26] and the carotid artery bifurcation [27] IMT at the posterior wall is greater in the areas with lower WSS. Also in normal coronary arteries, wall thickness and shear stress correlate negatively [63].
Mean WSS was not significantly different in men and women, either in the common carotid artery [53] or in the brachial artery [9].

3.2.2 In animals

Most of the shear stress data obtained in large arteries of anaesthetized animals are calculated from blood flow (as recorded optically, electromagnetically or by means of ultrasound), diameter and blood viscosity, using Poiseuille’s law. These mean shear stress data are likely to be underestimations and do not necessarily represent the shear stress value near the artery wall. Moreover, a substantial spread in the data is observed, for example, varying in the common carotid artery between 1.6 and 4.6 Pa in dogs and between 1.2 and 8.4 Pa in mice [7]. The error made in estimating the internal diameter of the artery likely contributes to this spread in the data. In dog coronary arteries shear stress was found to be around 1.0 Pa in arteries with a diameter larger than 160 μm and around 1.9 Pa in smaller ones [56]. Despite the spread in the data, it may be concluded that mean shear stress is not constant along the arterial tree in animals either [7].

3.2.3 Across species

Across species mean shear stress decreases with an increase in estimated internal arterial diameter. In their allometric scaling study, Greve and colleagues [18] showed that across species, including mice, rats, dogs and humans, mean WSS in the infra-renal aorta decreases linearly with body mass on a log/log scale. In this part of the aorta mean WSS was estimated to be about 0.5 Pa in men, about 7 Pa in rat and about 8.8 Pa in mice. In the common carotid artery mean shear stress varies on the average from about 1.2 Pa in humans to on the average about 7.0 Pa in mice [7]. Thus, the lesson to be learned is that in a particular artery mean shear stress will be higher, the smaller the animal is (Table 2).
Table 2
Differences in mean wall shear stress (Pa) in a particular artery across species
 
Man
Rat
Mouse
Infrarenal aortaa
0.5
7.0
8.8
Common carotid Ab
1.2
4.0
7.0
aAccording to Greve et al. [18]
bAccording to Cheng et al. [7]

4 Comments regarding the assessment of WSS in vivo

Using nanometer particles, shear rate can be determined close to the wall in arterioles. In large arteries, however, WSR is determined at some distance from the wall and, hence, the values obtained in arteries are least estimates, because shear rate increases toward the wall. Despite this underestimation, WSS as estimated at a distance from the wall will not be too different from the value at the wall, because viscosity decreases toward the wall. Shear stress can be more or less considered as a continuum from the center of the vessel to the wall. Although assessed in venules, extrapolation of the data on shear stress and shear rate as a function of vessel radius, as published by Long et al. [32], indicates that shear stress determined at 250–300 μm from the wall will underestimate wall shear stress by about 10%. For an artery with a lumen diameter of 6 mm, a distance of 300 μm, as in our ultrasound system, converts to a relative radial position of 0.9.
As indicated above, the in vivo recorded velocity profiles are generally flattened parabolas, in both large arteries and arterioles. It has been shown that in arterioles WSR is on the average 2.1 times lower (range: 1.5–3.9 times) when derived from a parabolic than from an actually measured velocity profile [57]. This underestimation of WSR, and, hence, of WSS, is even more pronounced when nanometer particles [32], allowing flow velocity assessments closer to the wall, rather than blood platelets [57, 58] are used as velocity tracers. Also in large arteries the WSR and WSS values calculated on the basis of a parabolic velocity profile are substantially lower than those derived from the actually measured profiles. In the common carotid artery mean WSR is underestimated by a factor of 2–3 [8, 20] and mean WSS by a factor of 2 [8], when assuming a parabolic velocity profile. In the brachial artery the underestimation of mean WSR and mean WSS is less pronounced [8], likely due to the more parabolic shape of the velocity profile in this artery. Such underestimations of WSR do not only affect calculated WSS, but also calculated or determined whole blood viscosity, which strongly depends on shear rate (Eq. 2).

5 Design of the arterial system with emphasis on the flow-diameter relations at bifurcations

The substantial differences in mean WSS along the arterial tree as found in vivo, in both man and animals, are in disagreement with the assumption that mean WSS is about constant along the arterial tree [22, 28]. As can be learned from Eq. (3), for fully developed flow, shear stress (τ) critically depends on the lumen diameter (d) of the artery:
$$ \tau = \frac{{4\eta v_{{\text{c}}} }} {d} = \frac{{32\eta q}} {{\pi d^{3} }} $$
(3)
where η is blood viscosity. To convert center stream velocity (v c) to volume flow (q), use is made of the property that for a parabolic flow distribution v c is twice the velocity averaged over the cross-sectional area (πd 2 /4).
The concept of constant mean WSS is based upon the principle of minimal work according to Murray’s law [39], which implies that the cube diameter of a vessel should be proportional to the flow through it, converting the last part of Eq. (3) into a constant. Consequently, the cube of the diameter of a parent vessel equals the sum of the cubes of the diameters of the daughter vessels. The constant mean WSS requires adaptation of the arterial diameter to the tangential shear stress τ, i.e., any slight increase and decrease in WSS is counteracted by a proportional increase and decrease in arterial diameter, respectively [21, 51, 54, 64]. To date, it has been well established experimentally that indeed WSS is an important determinant of arterial diameter, both acutely and chronically, and that the adaptation process is of great importance in maintaining mean WSS within limits, in both large arteries and arterioles, despite changing peripheral blood flow requirements [6, 23, 24] and changes in blood viscosity [21, 37, 38].
In Murray’s law, however, it is assumed that Poiseuille’s law can be applied to the arterial system, which, among others, implies that the velocity profile is considered to be fully developed to a parabola. In general Poiseiulle’s law does not hold for the arterial system in vivo, because of the pulsatile nature of the flow, and branching, curving and tapering of the arteries. This is for instance demonstrated by the fact that the systolic velocity profile as recorded in vivo, is a flattened parabola rather than a fully developed one, in arteries due to flow unsteadiness and short entrance lengths and in arterioles mainly due to dominating viscous forces.
The validity of Murray’s “cube law” (q = cd 3 ) for the whole arterial tree has been challenged by Zamir and colleagues [65]. They showed that in the major branches of the aortic arch the relation between flow and diameter is governed by a “square law”, which would suggest (Eq. 3) that flow velocity is constant, independent of the diameter [65]. A “square law” for the whole arterial tree, however, is incompatible with the observation that mean blood flow velocity also varies along the arterial tree, in animals [30] as well as in man [49]. The observation that neither mean WSS, nor mean velocity is constant along the arterial tree indicates that the exponent in the power law may vary along the arterial tree, a concept already considered by Zamir and colleagues [65]. At the present state of the art, it may be concluded that Murray’s law does not hold for the whole arterial system and that the exponent of the power law varies along the arterial tree, possibly from 2 in larger arteries [65] to about 3 in arterioles [33]. In line with this idea is the earlier observation that the exponent of the power law was found to be 2.55 in coronary arteries [1].
One should bear in mind that the varying mean WSS values and the varying exponents of the power law along the arterial tree, as described above, refer to the situation at rest. During exercise the situation is likely to be different due to adaptation of the peripheral resistance during vasodilatation. In the femoral artery vasodilatation results in disappearance of reflections and in mean WSS values close to those in the common carotid artery [25]. The increased WSS values during vasodilatation indicate that the artery is incapable to fully counteract the increase in shear stress by lumen enlargement. During strenuous exercise the increase in mean WSS will even be more pronounced. Under these circumstances volume flow in the femoral artery may increase tenfold, which requires at least doubling of the arterial diameter (Eq. 3) to maintain shear stress at the same level. However, under sustained high flow conditions the increase in arterial diameter will maximally be about 20%, as indicated by flow-mediated dilatation experiments in the brachial artery. A tenfold increase in flow in combination with a 20% increase in diameter will cause a 5.8-fold increase in shear stress (Eq. 3), resulting in mean WSS values between 1.8 and 3.0 Pa in the femoral artery bifurcation during strenuous exercise.

6 Concluding considerations

The in vivo data presented clearly show that at rest mean WSS is far from constant along the arterial tree as predicted by theory, neither in man, nor in animals. In man mean WSS is about four times higher in the carotid artery than in the femoral and brachial arteries. The lower mean WSS in the latter arteries can be explained by the high peripheral resistance in these arteries at rest and is logical from a physiological point of view. It allows for an increase in mean WSS during exercise without reaching high levels that could be damaging to endothelial cells. During exercise, after all, the arteries may have to accommodate ten times higher blood flows, which would lead to too high WSS levels when starting at a high level already, because arteries can dilate maximally 20%. It is also shown that across species WSS in a particular artery is substantially different and will be higher, the smaller the animal is. Also along arterial bifurcations, and within arteriolar networks and a specific artery WSS may vary. The differences in WSS along the arterial tree as described in this review refer to developed arterial systems. In developing arterial systems WSS has been shown to be constant along the arterial system, at least in arteries with a diameter larger than about 60 μm [29]. Apparently, the diameter adapts to the flow to be carried during development. This does not imply that WSS is the sole determinant of importance in the developing arterial system. Model studies have shown that stable arterial systems can only develop and be maintained through interplay among WSS, arterial pressure, circumferential stress [19, 45, 46] and metabolic tissue status [45].
The differences in mean WSS along the arterial tree imply that Murray’s cube law of minimal energy discharge does not hold for the whole arterial system. A square law cannot be applied to the whole arterial tree either, because mean blood flow velocity also varies along this tree. At the present state of the art, it may be concluded that the exponent of the power law varies along the arterial tree, probably from 2 in large arteries near the heart to 3 in arterioles.
The in vivo observations on mean WSS also have consequences for the in vitro studies on the interaction between shear stress and endothelial cell gene expression. In these studies endothelial cells are exposed to an average shear stress value calculated based upon Poiseuille’s law and assuming shear stress to be constant along the arterial tree. Poiseuille’s law cannot be applied and, based upon the in vivo findings, no average shear stress value can be taken to study effects on endothelial cells derived from different vascular areas or from the same artery in different species. The cells have to be studied under the shear stress conditions they are exposed to in real life.
It should be kept in mind that the ultrasound techniques presently available to non-invasively assess WSR, and, hence, WSS, in vivo do have their limitations. Not only is the spatial resolution of the systems limited, but at the present state-of-the-art WSR can reliably be determined only in relatively straight arteries. This is a serious limitation, because information about the level of WSS and its direction in arterial bifurcations, especially opposite to flow dividers, is of utmost importance when studying the role of WSS in atherogenesis. In our institute we are working on a different approach to the assessment of velocity profiles, using multiple lines of observation (multiple M-line technique), that may allow assessment of the shear rate distribution in bifurcations as the carotid artery bulb.
Open Access This is an open access article distributed under the terms of the Creative Commons Attribution Noncommercial License ( https://​creativecommons.​org/​licenses/​by-nc/​2.​0 ), which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
Literatur
1.
Zurück zum Zitat Arts T, Kruger RT, van Gerven W, Lambregts JA, Reneman RS (1979) Propagation velocity and reflection of pressure waves in the canine coronary artery. Am J Physiol 237:H469–H474PubMed Arts T, Kruger RT, van Gerven W, Lambregts JA, Reneman RS (1979) Propagation velocity and reflection of pressure waves in the canine coronary artery. Am J Physiol 237:H469–H474PubMed
2.
Zurück zum Zitat Bakker EN, Versluis JP, Sipkema P, VanTeeffelen JW, Rolf TM, Spaan JA, VanBavel E (2003) Differential structural adaptation to haemodynamics along single rat cremaster arterioles. J Physiol 548:549–555CrossRefPubMedPubMedCentral Bakker EN, Versluis JP, Sipkema P, VanTeeffelen JW, Rolf TM, Spaan JA, VanBavel E (2003) Differential structural adaptation to haemodynamics along single rat cremaster arterioles. J Physiol 548:549–555CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Brands PJ, Hoeks APG, Hofstra L, Reneman RS (1995) A noninvasive method to estimate wall shear rate using ultrasound. Ultrasound Med Biol 21:171–185CrossRefPubMed Brands PJ, Hoeks APG, Hofstra L, Reneman RS (1995) A noninvasive method to estimate wall shear rate using ultrasound. Ultrasound Med Biol 21:171–185CrossRefPubMed
4.
Zurück zum Zitat Brands PJ, Hoeks APG, Reneman RS (1995) The effect of echo suppression on the mean velocity estimation range of the rf cross-correlation model estimator. Ultrasound Med Biol 21:945–959CrossRefPubMed Brands PJ, Hoeks APG, Reneman RS (1995) The effect of echo suppression on the mean velocity estimation range of the rf cross-correlation model estimator. Ultrasound Med Biol 21:945–959CrossRefPubMed
5.
Zurück zum Zitat Broeders MA, Tangelder GJ, Slaaf DW, Reneman RS, oude Egbrink MG (1998) Endogenous nitric oxide protects against thromboembolism in venules but not in arterioles. Arterioscler Thromb Vasc Biol 18:139–145CrossRefPubMed Broeders MA, Tangelder GJ, Slaaf DW, Reneman RS, oude Egbrink MG (1998) Endogenous nitric oxide protects against thromboembolism in venules but not in arterioles. Arterioscler Thromb Vasc Biol 18:139–145CrossRefPubMed
6.
Zurück zum Zitat Busse R, Fleming I (1998) Pulsatile stretch and shear stress; physical stimuli determining the production of endothelium-derived relaxing factors. J Vasc Res 35:73–84CrossRefPubMed Busse R, Fleming I (1998) Pulsatile stretch and shear stress; physical stimuli determining the production of endothelium-derived relaxing factors. J Vasc Res 35:73–84CrossRefPubMed
7.
Zurück zum Zitat Cheng C, Helderman F, Tempel D, Segers D, Hierck B, Poelmann R, van Tol A, Duncker DJ, Robbers-Visser D, Ursem NT, van Haperen R, Wentzel JJ, Gijsen F, van der Steen AF, de Crom R, Krams R (2007) Large variations in absolute wall shear stress levels within one species and between species. Atherosclerosis 195:225–235CrossRefPubMed Cheng C, Helderman F, Tempel D, Segers D, Hierck B, Poelmann R, van Tol A, Duncker DJ, Robbers-Visser D, Ursem NT, van Haperen R, Wentzel JJ, Gijsen F, van der Steen AF, de Crom R, Krams R (2007) Large variations in absolute wall shear stress levels within one species and between species. Atherosclerosis 195:225–235CrossRefPubMed
8.
Zurück zum Zitat Dammers R, Stifft F, Tordoir JH, Hameleers JM, Hoeks AP, Kitslaar PJ (2003) Shear stress depends on vascular territory: comparison between common carotid and brachial artery. J Appl Physiol 94:485–489CrossRefPubMed Dammers R, Stifft F, Tordoir JH, Hameleers JM, Hoeks AP, Kitslaar PJ (2003) Shear stress depends on vascular territory: comparison between common carotid and brachial artery. J Appl Physiol 94:485–489CrossRefPubMed
9.
Zurück zum Zitat Dammers R, Tordoir JHM, Hameleers JMM, Kitslaar PJEHM, Hoeks APG (2002) Brachial artery shear stress is independent of gender or age and does not modify vessel wall mechanical properties. Ultrasound Med Biol 28:1015–1022CrossRefPubMed Dammers R, Tordoir JHM, Hameleers JMM, Kitslaar PJEHM, Hoeks APG (2002) Brachial artery shear stress is independent of gender or age and does not modify vessel wall mechanical properties. Ultrasound Med Biol 28:1015–1022CrossRefPubMed
10.
Zurück zum Zitat Davies PF, Tripathi SC (1993) Mechanical stress mechanisms and the cell. An endothelial paradigm. Circ Res 72:239–245CrossRefPubMed Davies PF, Tripathi SC (1993) Mechanical stress mechanisms and the cell. An endothelial paradigm. Circ Res 72:239–245CrossRefPubMed
11.
Zurück zum Zitat Dekker RJ, Boon RA, Rondaij MG, Kragt A, Volger OL, Elderkamp YW, Meijers JC, Voorberg J, Pannekoek H, Horrevoets AJ (2006) KLF2 provokes a gene expression pattern that establishes functional quiescent differentiation of the endothelium. Blood 107:4354–4363CrossRefPubMed Dekker RJ, Boon RA, Rondaij MG, Kragt A, Volger OL, Elderkamp YW, Meijers JC, Voorberg J, Pannekoek H, Horrevoets AJ (2006) KLF2 provokes a gene expression pattern that establishes functional quiescent differentiation of the endothelium. Blood 107:4354–4363CrossRefPubMed
12.
Zurück zum Zitat Doriot PA, Dorsaz PA, Dorsaz L, De Benedetti E, Chatelain P, Delafontaine P (2000) In-vivo measurements of wall shear stress in human coronary arteries. Coron Artery Dis 11:495–502CrossRefPubMed Doriot PA, Dorsaz PA, Dorsaz L, De Benedetti E, Chatelain P, Delafontaine P (2000) In-vivo measurements of wall shear stress in human coronary arteries. Coron Artery Dis 11:495–502CrossRefPubMed
14.
Zurück zum Zitat Furchgott RF (1983) Role of endothelium in responses of vascular smooth muscle. Circ Res 53:557–573CrossRefPubMed Furchgott RF (1983) Role of endothelium in responses of vascular smooth muscle. Circ Res 53:557–573CrossRefPubMed
15.
Zurück zum Zitat Gatehouse PD, Keegan J, Crowe LA, Masood S, Mohiaddin RH, Kreitner KF, Firmin DN (2005) Applications of phase-contrast flow and velocity imaging in cardiovascular MRI. Eur Radiol 15:2172–2184CrossRefPubMed Gatehouse PD, Keegan J, Crowe LA, Masood S, Mohiaddin RH, Kreitner KF, Firmin DN (2005) Applications of phase-contrast flow and velocity imaging in cardiovascular MRI. Eur Radiol 15:2172–2184CrossRefPubMed
16.
Zurück zum Zitat Gimbrone MA, Topper JN (1999) Biology of the vessel wall. In: Chien KR (eds) Molecular basis of cardiovascular disease. Saunders, Philadelphia, pp 331–348 Gimbrone MA, Topper JN (1999) Biology of the vessel wall. In: Chien KR (eds) Molecular basis of cardiovascular disease. Saunders, Philadelphia, pp 331–348
17.
Zurück zum Zitat Gnasso A, Carallo C, Irace C, Spagnuolo V, De Novara G, Mattiolo PL, Pujia A (1996) Association between intima-media thickness and wall shear stress in common carotid artery in healthy male subjects. Circulation 94:3257–3262CrossRefPubMed Gnasso A, Carallo C, Irace C, Spagnuolo V, De Novara G, Mattiolo PL, Pujia A (1996) Association between intima-media thickness and wall shear stress in common carotid artery in healthy male subjects. Circulation 94:3257–3262CrossRefPubMed
18.
Zurück zum Zitat Greve JM, Les AS, Tang BT, Draney Blomme MT, Wilson NM, Dalman RL, Pelc NJ, Taylor CA (2006) Allometric scaling of wall shear stress from mice to humans: quantification using cine phase-contrast MRI and computational fluid dynamics. Am J Physiol Heart Circ Physiol 291:H1700–H1708CrossRefPubMed Greve JM, Les AS, Tang BT, Draney Blomme MT, Wilson NM, Dalman RL, Pelc NJ, Taylor CA (2006) Allometric scaling of wall shear stress from mice to humans: quantification using cine phase-contrast MRI and computational fluid dynamics. Am J Physiol Heart Circ Physiol 291:H1700–H1708CrossRefPubMed
19.
Zurück zum Zitat Hacking WJ, VanBavel E, Spaan JA (1996) Shear stress is not sufficient to control growth of vascular networks: a model study. Am J Physiol 270:H364–H375PubMed Hacking WJ, VanBavel E, Spaan JA (1996) Shear stress is not sufficient to control growth of vascular networks: a model study. Am J Physiol 270:H364–H375PubMed
20.
Zurück zum Zitat Hoeks APG, Samijo SK, Brands PJ, Reneman RS (1995) Assessment of wall shear rate in humans: an ultrasound study. J Vasc Invest 1:108–117 Hoeks APG, Samijo SK, Brands PJ, Reneman RS (1995) Assessment of wall shear rate in humans: an ultrasound study. J Vasc Invest 1:108–117
21.
Zurück zum Zitat Kamiya A, Togawa T (1980) Adaptive regulation of wall shear stress to flow change in the canine carotid artery. Am J Physiol 239:H14–H21PubMed Kamiya A, Togawa T (1980) Adaptive regulation of wall shear stress to flow change in the canine carotid artery. Am J Physiol 239:H14–H21PubMed
22.
Zurück zum Zitat Kassab GS, Fung YC (1995) The pattern of coronary arteriolar bifurcations and the uniform shear hypothesis. Ann Biomed Eng 23:13–20CrossRefPubMed Kassab GS, Fung YC (1995) The pattern of coronary arteriolar bifurcations and the uniform shear hypothesis. Ann Biomed Eng 23:13–20CrossRefPubMed
23.
Zurück zum Zitat Koller A, Huang A (1999) Development of nitric oxide and prostaglandin mediation of shear stress-induced arteriolar dilation with aging and hypertension. Hypertension 34:1073–1079CrossRefPubMed Koller A, Huang A (1999) Development of nitric oxide and prostaglandin mediation of shear stress-induced arteriolar dilation with aging and hypertension. Hypertension 34:1073–1079CrossRefPubMed
24.
Zurück zum Zitat Koller A, Kaley G (1996) Shear stress dependent regulation of vascular resistance in health and disease: role of endothelium. Endothelium 4:247–272CrossRef Koller A, Kaley G (1996) Shear stress dependent regulation of vascular resistance in health and disease: role of endothelium. Endothelium 4:247–272CrossRef
25.
Zurück zum Zitat Kornet L, Hoeks AP, Lambregts J, Reneman RS (2000) Mean wall shear stress in the femoral arterial bifurcation is low and independent of age at rest. J Vasc Res 37:112–122CrossRefPubMed Kornet L, Hoeks AP, Lambregts J, Reneman RS (2000) Mean wall shear stress in the femoral arterial bifurcation is low and independent of age at rest. J Vasc Res 37:112–122CrossRefPubMed
26.
Zurück zum Zitat Kornet L, Hoeks APG, Lambregts J, Reneman RS (1999) In the femoral artery bifurcation differences in mean wall shear stress within subjects are associated with different intima-media thicknesses. Arterioscler Thromb Vasc Biol 19:2933–2939CrossRefPubMed Kornet L, Hoeks APG, Lambregts J, Reneman RS (1999) In the femoral artery bifurcation differences in mean wall shear stress within subjects are associated with different intima-media thicknesses. Arterioscler Thromb Vasc Biol 19:2933–2939CrossRefPubMed
27.
Zurück zum Zitat Kornet L, Lambregts JAC, Hoeks APG, Reneman RS (1998) Differences in near-wall shear rate in the carotid artery within subjects are associated with different intima-media thicknesses. Arterioscl Thromb Vasc Biol 18:1877–1884CrossRefPubMed Kornet L, Lambregts JAC, Hoeks APG, Reneman RS (1998) Differences in near-wall shear rate in the carotid artery within subjects are associated with different intima-media thicknesses. Arterioscl Thromb Vasc Biol 18:1877–1884CrossRefPubMed
28.
Zurück zum Zitat LaBarbera M (1990) Principles of design of fluid transport systems in zoology. Science 249:992–1000CrossRefPubMed LaBarbera M (1990) Principles of design of fluid transport systems in zoology. Science 249:992–1000CrossRefPubMed
29.
Zurück zum Zitat le Noble F, Fleury V, Pries A, Corvol P, Eichmann A, Reneman RS (2005) Control of arterial branching morphogenesis in embryogenesis: go with the flow. Cardiovasc Res 65:619–628CrossRefPubMed le Noble F, Fleury V, Pries A, Corvol P, Eichmann A, Reneman RS (2005) Control of arterial branching morphogenesis in embryogenesis: go with the flow. Cardiovasc Res 65:619–628CrossRefPubMed
30.
Zurück zum Zitat Li YH, Reddy AK, Taffet GE, Michael LH, Entman ML, Hartley CJ (2003) Doppler evaluation of peripheral vascular adaptations to transverse aortic banding in mice. Ultrasound Med Biol 29:1281–1289CrossRefPubMed Li YH, Reddy AK, Taffet GE, Michael LH, Entman ML, Hartley CJ (2003) Doppler evaluation of peripheral vascular adaptations to transverse aortic banding in mice. Ultrasound Med Biol 29:1281–1289CrossRefPubMed
31.
Zurück zum Zitat Lipowsky HH, Kovalcheck S, Zweifach BW (1978) The distribution of blood rheological parameters in the microvasculature of cat mesentery. Circ Res 43:738–749CrossRefPubMed Lipowsky HH, Kovalcheck S, Zweifach BW (1978) The distribution of blood rheological parameters in the microvasculature of cat mesentery. Circ Res 43:738–749CrossRefPubMed
32.
Zurück zum Zitat Long DS, Smith ML, Pries AR, Ley K, Damiano ER (2004) Microviscometry reveals reduced blood viscosity and altered shear rate and shear stress profiles in microvessels after hemodilution. Proc Natl Acad Sci USA 101:10060–10065CrossRefPubMedPubMedCentral Long DS, Smith ML, Pries AR, Ley K, Damiano ER (2004) Microviscometry reveals reduced blood viscosity and altered shear rate and shear stress profiles in microvessels after hemodilution. Proc Natl Acad Sci USA 101:10060–10065CrossRefPubMedPubMedCentral
33.
Zurück zum Zitat Mayrovitz HN, Roy J (1983) Microvascular blood flow: evidence indicating a cubic dependence on arteriolar diameter. Am J Physiol 245:H1031–H1038PubMed Mayrovitz HN, Roy J (1983) Microvascular blood flow: evidence indicating a cubic dependence on arteriolar diameter. Am J Physiol 245:H1031–H1038PubMed
34.
Zurück zum Zitat McCue S, Dajnowiec D, Xu F, Zhang M, Jackson MR, Langille BL (2006) Shear stress regulates forward and reverse planar cell polarity of vascular endothelium in vivo and in vitro. Circ Res 98:939–946CrossRefPubMed McCue S, Dajnowiec D, Xu F, Zhang M, Jackson MR, Langille BL (2006) Shear stress regulates forward and reverse planar cell polarity of vascular endothelium in vivo and in vitro. Circ Res 98:939–946CrossRefPubMed
35.
Zurück zum Zitat Meinders JM, Brands PJ, Willigers JM, Kornet L, Hoeks AP (2001) Assessment of the spatial homogeneity of artery dimension parameters with high frame rate 2-D B-mode. Ultrasound Med Biol 27:785–794CrossRefPubMed Meinders JM, Brands PJ, Willigers JM, Kornet L, Hoeks AP (2001) Assessment of the spatial homogeneity of artery dimension parameters with high frame rate 2-D B-mode. Ultrasound Med Biol 27:785–794CrossRefPubMed
36.
Zurück zum Zitat Meinders JM, Kornet L, Hoeks AP (2003) Assessment of spatial inhomogeneities in intima media thickness along an arterial segment using its dynamic behavior. Am J Physiol Heart Circ Physiol 285:H384–H391CrossRefPubMed Meinders JM, Kornet L, Hoeks AP (2003) Assessment of spatial inhomogeneities in intima media thickness along an arterial segment using its dynamic behavior. Am J Physiol Heart Circ Physiol 285:H384–H391CrossRefPubMed
37.
Zurück zum Zitat Melkumyants AM, Balashov SA (1990) Effect of blood viscocity on arterial flow induced dilator response. Cardiovasc Res 24:165–168CrossRefPubMed Melkumyants AM, Balashov SA (1990) Effect of blood viscocity on arterial flow induced dilator response. Cardiovasc Res 24:165–168CrossRefPubMed
38.
Zurück zum Zitat Melkumyants AM, Balashov SA, Khayutin VM (1995) Control of arterial lumen by shear stress on endothelium. NIPS 10:204–210 Melkumyants AM, Balashov SA, Khayutin VM (1995) Control of arterial lumen by shear stress on endothelium. NIPS 10:204–210
39.
Zurück zum Zitat Murray CD (1926) The physiological principle of minimum work: I. The vascular system and the cost of blood volume. Proc Natl Acad Sci USA 12:207–214CrossRefPubMedPubMedCentral Murray CD (1926) The physiological principle of minimum work: I. The vascular system and the cost of blood volume. Proc Natl Acad Sci USA 12:207–214CrossRefPubMedPubMedCentral
40.
Zurück zum Zitat Oyre S, Pedersen EM, Ringgaard S, Boesiger P, Paaske WP (1997) In vivo wall shear stress measured by magnetic resonance velocity mapping in the normal human abdominal aorta. Eur J Vasc Endovasc Surg 13:263–271CrossRefPubMed Oyre S, Pedersen EM, Ringgaard S, Boesiger P, Paaske WP (1997) In vivo wall shear stress measured by magnetic resonance velocity mapping in the normal human abdominal aorta. Eur J Vasc Endovasc Surg 13:263–271CrossRefPubMed
41.
Zurück zum Zitat Oyre S, Ringgaard S, Kozerke S, Paaske WP, Erlandsen M, Boesiger P, Pedersen EM (1998) Accurate noninvasive quantitation of blood flow, cross-sectional lumen vessel area and wall shear stress by three-dimensional paraboloid modeling of magnetic resonance imaging velocity data. J Am Coll Cardiol 32:128–134CrossRefPubMed Oyre S, Ringgaard S, Kozerke S, Paaske WP, Erlandsen M, Boesiger P, Pedersen EM (1998) Accurate noninvasive quantitation of blood flow, cross-sectional lumen vessel area and wall shear stress by three-dimensional paraboloid modeling of magnetic resonance imaging velocity data. J Am Coll Cardiol 32:128–134CrossRefPubMed
42.
Zurück zum Zitat Parmar KM, Larman HB, Dai G, Zhang Y, Wang ET, Moorthy SN, Kratz JR, Lin Z, Jain MK, Gimbrone MA Jr, Garcia-Cardena G (2006) Integration of flow-dependent endothelial phenotypes by Kruppel-like factor 2. J Clin Invest 116:49–58CrossRefPubMed Parmar KM, Larman HB, Dai G, Zhang Y, Wang ET, Moorthy SN, Kratz JR, Lin Z, Jain MK, Gimbrone MA Jr, Garcia-Cardena G (2006) Integration of flow-dependent endothelial phenotypes by Kruppel-like factor 2. J Clin Invest 116:49–58CrossRefPubMed
43.
Zurück zum Zitat Perktold K, Thurner E, Kenner T (1994) Flow and stress characteristics in rigid walled and compliant carotid artery bifurcation models. Med Biol Eng Comput 32:19–26CrossRefPubMed Perktold K, Thurner E, Kenner T (1994) Flow and stress characteristics in rigid walled and compliant carotid artery bifurcation models. Med Biol Eng Comput 32:19–26CrossRefPubMed
44.
Zurück zum Zitat Pohl U, Holtz J, Busse R, Bassenge E (1986) Crucial role of endothelium in the vasodilator response to increased flow in vivo. Hypertension 8:37–44CrossRefPubMed Pohl U, Holtz J, Busse R, Bassenge E (1986) Crucial role of endothelium in the vasodilator response to increased flow in vivo. Hypertension 8:37–44CrossRefPubMed
45.
Zurück zum Zitat Pries AR, Secomb TW (2005) Control of blood vessel structure: insights from theoretical models. Am J Physiol Heart Circ Physiol 288:H1010–H1015CrossRefPubMed Pries AR, Secomb TW (2005) Control of blood vessel structure: insights from theoretical models. Am J Physiol Heart Circ Physiol 288:H1010–H1015CrossRefPubMed
46.
Zurück zum Zitat Pries AR, Secomb TW, Gaethgens P (1995) Design principles of vascular beds. Circ Res 77:1017–1023CrossRefPubMed Pries AR, Secomb TW, Gaethgens P (1995) Design principles of vascular beds. Circ Res 77:1017–1023CrossRefPubMed
47.
Zurück zum Zitat Pries AR, Secomb TW, Gessner T, Sperandio MB, Gross JF, Gaehtgens P (1994) Resistance to blood flow in microvessels in vivo. Circ Res 75:904–915CrossRefPubMed Pries AR, Secomb TW, Gessner T, Sperandio MB, Gross JF, Gaehtgens P (1994) Resistance to blood flow in microvessels in vivo. Circ Res 75:904–915CrossRefPubMed
48.
Zurück zum Zitat Reneman RS, Arts T, Hoeks AP (2006) Wall shear stress—an important determinant of endothelial cell function and structure—in the arterial system in vivo. Discrepancies with theory. J Vasc Res 43:251–269CrossRefPubMed Reneman RS, Arts T, Hoeks AP (2006) Wall shear stress—an important determinant of endothelial cell function and structure—in the arterial system in vivo. Discrepancies with theory. J Vasc Res 43:251–269CrossRefPubMed
49.
Zurück zum Zitat Reneman RS, Arts T, Hoeks AP (2008) WSS in the arterial system in vivo—Assessment, results and comparison with theory. In: Yim P (eds) Hemodynamics: bioengineering and clinical perspectives. Wiley, New Jersey (in press) Reneman RS, Arts T, Hoeks AP (2008) WSS in the arterial system in vivo—Assessment, results and comparison with theory. In: Yim P (eds) Hemodynamics: bioengineering and clinical perspectives. Wiley, New Jersey (in press)
50.
Zurück zum Zitat Reneman RS, Woldhuis B, oude Egbrink MGA, Slaaf DW, Tangelder GJ (1992) Concentration and velocity profiles of blood cells in the microcirculation. In: Hwang NHC, Turitto VT, Yen MRT (eds) Advances in cardiovascular engineering. Plenum Press, New York, pp 25–40CrossRef Reneman RS, Woldhuis B, oude Egbrink MGA, Slaaf DW, Tangelder GJ (1992) Concentration and velocity profiles of blood cells in the microcirculation. In: Hwang NHC, Turitto VT, Yen MRT (eds) Advances in cardiovascular engineering. Plenum Press, New York, pp 25–40CrossRef
52.
Zurück zum Zitat Roevros JMJG (1974) Analogue processing of C.W.-Doppler flowmeter signals to determine average frequency shift momentaneously without the use of a wave analyzer. In: Reneman RS (eds) Cardiovascular applications of ultrasound. North-Holland, Amsterdam, pp 43–54 Roevros JMJG (1974) Analogue processing of C.W.-Doppler flowmeter signals to determine average frequency shift momentaneously without the use of a wave analyzer. In: Reneman RS (eds) Cardiovascular applications of ultrasound. North-Holland, Amsterdam, pp 43–54
53.
Zurück zum Zitat Samijo SK, Willigers JM, Barkhuysen R, Kitslaar PJEHM, Reneman RS, Hoeks APG (1998) Wall shear stress in the common carotid artery as function of age and gender. Cardiovasc Res 39:515–522CrossRefPubMed Samijo SK, Willigers JM, Barkhuysen R, Kitslaar PJEHM, Reneman RS, Hoeks APG (1998) Wall shear stress in the common carotid artery as function of age and gender. Cardiovasc Res 39:515–522CrossRefPubMed
54.
Zurück zum Zitat Sherman TF (1981) On connecting large vessels to small. The meaning of Murray’s law. J Gen Physiol 78:431–453CrossRefPubMed Sherman TF (1981) On connecting large vessels to small. The meaning of Murray’s law. J Gen Physiol 78:431–453CrossRefPubMed
55.
Zurück zum Zitat Silber HA, Ouyang P, Bluemke DA, Gupta SN, Foo TK, Lima JA (2005) Why is flow-mediated dilation dependent on arterial size? Assessment of the shear stimulus using phase-contrast magnetic resonance imaging. Am J Physiol Heart Circ Physiol 288:H822–H828CrossRefPubMed Silber HA, Ouyang P, Bluemke DA, Gupta SN, Foo TK, Lima JA (2005) Why is flow-mediated dilation dependent on arterial size? Assessment of the shear stimulus using phase-contrast magnetic resonance imaging. Am J Physiol Heart Circ Physiol 288:H822–H828CrossRefPubMed
56.
Zurück zum Zitat Stepp DW, Nishikawa Y, Chilian WM (1999) Regulation of shear stress in the canine coronary microcirculation. Circulation 100:1555–1561CrossRefPubMed Stepp DW, Nishikawa Y, Chilian WM (1999) Regulation of shear stress in the canine coronary microcirculation. Circulation 100:1555–1561CrossRefPubMed
57.
Zurück zum Zitat Tangelder GJ, Slaaf DW, Arts T, Reneman RS (1988) Wall shear rate in arterioles in vivo: least estimates from platelet velocity profiles. Am J Physiol 254:H1059–H1064PubMed Tangelder GJ, Slaaf DW, Arts T, Reneman RS (1988) Wall shear rate in arterioles in vivo: least estimates from platelet velocity profiles. Am J Physiol 254:H1059–H1064PubMed
58.
Zurück zum Zitat Tangelder GJ, Slaaf DW, Muijtjens AM, Arts T, oude Egbrink MG, Reneman RS (1986) Velocity profiles of blood platelets and red blood cells flowing in arterioles of the rabbit mesentery. Circ Res 59:505–514CrossRefPubMed Tangelder GJ, Slaaf DW, Muijtjens AM, Arts T, oude Egbrink MG, Reneman RS (1986) Velocity profiles of blood platelets and red blood cells flowing in arterioles of the rabbit mesentery. Circ Res 59:505–514CrossRefPubMed
59.
Zurück zum Zitat Teirlinck HC, Tangelder GJ, Slaaf DW, Muijtjens AM, Arts T, Reneman RS (1984) Orientation and diameter distribution of rabbit blood platelets flowing in small arterioles. Biorheology 21:317–331PubMed Teirlinck HC, Tangelder GJ, Slaaf DW, Muijtjens AM, Arts T, Reneman RS (1984) Orientation and diameter distribution of rabbit blood platelets flowing in small arterioles. Biorheology 21:317–331PubMed
60.
Zurück zum Zitat Topper JN, Gimbrone MA (1999) Blood flow and vascular gene expression: fluid shear stress as a modulator of endothelial phenotype. Mol Med Today 5:40–46CrossRefPubMed Topper JN, Gimbrone MA (1999) Blood flow and vascular gene expression: fluid shear stress as a modulator of endothelial phenotype. Mol Med Today 5:40–46CrossRefPubMed
61.
Zurück zum Zitat Vennemann P, Kiger KT, Lindken R, Groenendijk BC, Stekelenburg-de Vos S, ten Hagen TL, Ursem NT, Poelmann RE, Westerweel J, Hierck BP (2006) In vivo micro particle image velocimetry measurements of blood-plasma in the embryonic avian heart. J Biomech 39:1191–1200CrossRefPubMed Vennemann P, Kiger KT, Lindken R, Groenendijk BC, Stekelenburg-de Vos S, ten Hagen TL, Ursem NT, Poelmann RE, Westerweel J, Hierck BP (2006) In vivo micro particle image velocimetry measurements of blood-plasma in the embryonic avian heart. J Biomech 39:1191–1200CrossRefPubMed
62.
Zurück zum Zitat Weaver JPA, Evans A, Walder DN (1969) The effect of increased fibrinogen content on the viscosity of blood. Clin Sci 36:1–10PubMed Weaver JPA, Evans A, Walder DN (1969) The effect of increased fibrinogen content on the viscosity of blood. Clin Sci 36:1–10PubMed
63.
Zurück zum Zitat Wentzel JJ, Janssen E, Vos J, Schuurbiers JC, Krams R, Serruys PW, de Feyter PJ, Slager CJ (2003) Extension of increased atherosclerotic wall thickness into high shear stress regions is associated with loss of compensatory remodeling. Circulation 108:17–23CrossRefPubMed Wentzel JJ, Janssen E, Vos J, Schuurbiers JC, Krams R, Serruys PW, de Feyter PJ, Slager CJ (2003) Extension of increased atherosclerotic wall thickness into high shear stress regions is associated with loss of compensatory remodeling. Circulation 108:17–23CrossRefPubMed
64.
Zurück zum Zitat Zamir M (1977) Shear forces and blood vessel radii in the cardiovascular system. J Gen Physiol 69:449–461CrossRefPubMed Zamir M (1977) Shear forces and blood vessel radii in the cardiovascular system. J Gen Physiol 69:449–461CrossRefPubMed
65.
Zurück zum Zitat Zamir M, Sinclair P, Wonnacott TH (1992) Relation between diameter and flow in major branches of the arch of the aorta. J Biomech 25:1303–1310CrossRefPubMed Zamir M, Sinclair P, Wonnacott TH (1992) Relation between diameter and flow in major branches of the arch of the aorta. J Biomech 25:1303–1310CrossRefPubMed
Metadaten
Titel
Wall shear stress as measured in vivo: consequences for the design of the arterial system
verfasst von
Robert S. Reneman
Arnold P. G. Hoeks
Publikationsdatum
01.05.2008
Verlag
Springer Berlin Heidelberg
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 5/2008
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-008-0330-2

Weitere Artikel der Ausgabe 5/2008

Medical & Biological Engineering & Computing 5/2008 Zur Ausgabe