Skip to main content
Erschienen in: Microsystem Technologies 6/2021

04.01.2021 | Technical Paper

Design and implementation of a photoplethysmography acquisition system with an optimized artificial neural network for accurate blood pressure measurement

verfasst von: Rajeev Kumar Pandey, Tse-Yu Lin, Paul C.-P. Chao

Erschienen in: Microsystem Technologies | Ausgabe 6/2021

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

A new neural network (NN) is orchestrated by this study to achieve high-accuracy in blood pressure (BP) estimation by a real-time photoplethysmography (PPG). The PPG system consists of an OLED/OPD module to detect the pulsation of blood vessels, followed by a readout circuitry. The circuit is comprised of transimpedance amplifier, a digital tune high order band pass filter, programmable gain amplifier (PGA), time interleave OLED driver, micro-controller unit, and the Bluetooth transceiver. The obtained PPG signals are subsequently processed with quality checking, feature extraction, and into an NN for estimating BP. The feature extraction is assisted, by principal component analysis (PCA) to reduce the total number of input features to five with accuracy assured. 96 subjects participated in data collection for calibrating the designed NN. The resulted correlation is 0.81, while the errors for SBP and DBP are 2.00 ± 6.08 and 1.87 ± 4.09 mmHg, respectively. According to the Advancement of Medical Instrumentation (AAMI) and British Hypertension Society (BHS), a BP device in Grade A needs to control its accuracy error less than ± 8 mmHg, based on which the BP sensor developed herein are in Grade A, since the resulted errors of ± 6.08 and ± 4.09 mmHg are both less than ± 8 mmHg, showing the satisfactory performance of the BP monitor developed by this study.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
Zurück zum Zitat Ahmad S, Chen S, Soueidan K, Batkin I, BolicDajani MH, Groza V (2012) Electrocardiogram-assisted blood pressure estimation. IEEE Trans Biomed Eng 59(3):608–618CrossRef Ahmad S, Chen S, Soueidan K, Batkin I, BolicDajani MH, Groza V (2012) Electrocardiogram-assisted blood pressure estimation. IEEE Trans Biomed Eng 59(3):608–618CrossRef
Zurück zum Zitat Bonomi AG, Schipper F, Eerikäinen LM, Margarito J, Aarts RM, Babaeizadeh S, Morree HM, Dekker LG (2016) Atrial fibrillation detection using photo-plethysmography and acceleration data at the wrist. In: 2016 Computing in Cardiology Conference (CinC), pp 277–280 Bonomi AG, Schipper F, Eerikäinen LM, Margarito J, Aarts RM, Babaeizadeh S, Morree HM, Dekker LG (2016) Atrial fibrillation detection using photo-plethysmography and acceleration data at the wrist. In: 2016 Computing in Cardiology Conference (CinC), pp 277–280
Zurück zum Zitat Bramwell JC, Hill AV (1992) The velocity of the pulse wave in man. Proc R Soc Lond Biol Charact 93(652):298–306 Bramwell JC, Hill AV (1992) The velocity of the pulse wave in man. Proc R Soc Lond Biol Charact 93(652):298–306
Zurück zum Zitat Chen PH, Fan RE, Lin JC (2006) A study on SMO-type decomposition methods for support vector machines. IEEE Trans Neural Netw 174:893–908CrossRef Chen PH, Fan RE, Lin JC (2006) A study on SMO-type decomposition methods for support vector machines. IEEE Trans Neural Netw 174:893–908CrossRef
Zurück zum Zitat Cohen Z, Haxha S (2017) Optical-based sensor prototype for continuous monitoring of the blood pressure. IEEE Sens J 17(13):4258–4268CrossRef Cohen Z, Haxha S (2017) Optical-based sensor prototype for continuous monitoring of the blood pressure. IEEE Sens J 17(13):4258–4268CrossRef
Zurück zum Zitat Ding X, Yan BP, Zhang Y-T, Liu J, Zhao N, Tsang HK (2017) Pulse transit time based continuous cuffless blood pressure estimation: A new extension and a comprehensive evaluation. Sci Rep 7(1):11554CrossRef Ding X, Yan BP, Zhang Y-T, Liu J, Zhao N, Tsang HK (2017) Pulse transit time based continuous cuffless blood pressure estimation: A new extension and a comprehensive evaluation. Sci Rep 7(1):11554CrossRef
Zurück zum Zitat Duan K, Qian Z, Atef M, Wang G (2016) A feature exploration methodology for learning based cuffless blood pressure measurement using photoplethysmography. In: 2016 38th Annual international conference of the IEEE engineering in medicine and biology society (EMBC), pp 6385–6388 Duan K, Qian Z, Atef M, Wang G (2016) A feature exploration methodology for learning based cuffless blood pressure measurement using photoplethysmography. In: 2016 38th Annual international conference of the IEEE engineering in medicine and biology society (EMBC), pp 6385–6388
Zurück zum Zitat Forouzanfar M, Ahmad S, Batkin I, Dajani HR, Groza VZ, Bolic M (2013) Coefficient-free blood pressure estimation based on pulse transit time-cuff pressure dependence. IEEE Trans Biomed Eng 60(7):1814–1824CrossRef Forouzanfar M, Ahmad S, Batkin I, Dajani HR, Groza VZ, Bolic M (2013) Coefficient-free blood pressure estimation based on pulse transit time-cuff pressure dependence. IEEE Trans Biomed Eng 60(7):1814–1824CrossRef
Zurück zum Zitat Gesche H, Grosskurth D, Küchler G, Patzak A (2012) Continuous blood pressure measurement by using the pulse transit time: Comparison to a cuff-based method. Eur J Appl Physiol 112(1):309–315CrossRef Gesche H, Grosskurth D, Küchler G, Patzak A (2012) Continuous blood pressure measurement by using the pulse transit time: Comparison to a cuff-based method. Eur J Appl Physiol 112(1):309–315CrossRef
Zurück zum Zitat Huang S-C, Hung P-H, Hong C-H, Wang H-M (2014) A new image blood pressure sensor based on PPG, RRT, BPTT, and harmonic balancing. IEEE Sens J 14(10):3685–3692CrossRef Huang S-C, Hung P-H, Hong C-H, Wang H-M (2014) A new image blood pressure sensor based on PPG, RRT, BPTT, and harmonic balancing. IEEE Sens J 14(10):3685–3692CrossRef
Zurück zum Zitat Kao YH, Chao P-CP, Wey CL (2019) Design and Validation of a New PPG Module to Acquire High-Quality Physiological Signals for High-Accuracy Biomedical Sensing. IEEE J Sel Topics Quantum Electron 25(1):1–10 (Art no. 69000210)CrossRef Kao YH, Chao P-CP, Wey CL (2019) Design and Validation of a New PPG Module to Acquire High-Quality Physiological Signals for High-Accuracy Biomedical Sensing. IEEE J Sel Topics Quantum Electron 25(1):1–10 (Art no. 69000210)CrossRef
Zurück zum Zitat Kao YH, Chao P-CP, Wey CL (2018) Towards maximizing the sensing accuracy of an cuffless, optical blood pressure sensor using a high-order front-end filter. Microsyst Technol 24:4621CrossRef Kao YH, Chao P-CP, Wey CL (2018) Towards maximizing the sensing accuracy of an cuffless, optical blood pressure sensor using a high-order front-end filter. Microsyst Technol 24:4621CrossRef
Zurück zum Zitat Kurylyak Y, Lamonaca F, Grimaldi D (2013) A neural network-based method for continuous blood pressure estimation from a PPG signal. In: 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC). Minneapolis, pp 280–283. https://doi.org/10.1109/I2MTC.2013.6555424 Kurylyak Y, Lamonaca F, Grimaldi D (2013) A neural network-based method for continuous blood pressure estimation from a PPG signal. In: 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC). Minneapolis, pp 280–283. https://​doi.​org/​10.​1109/​I2MTC.​2013.​6555424
Zurück zum Zitat Lin Q, Xu J, Song S, Breeschoten A, Konijnenburg M, Chen M, Hoof C, Tavernier F, Helleputte NV (2019) A 196μW, Reconfigurable lightto-digital converter with 119dB dynamic range, for wearable PPG/NIRS sensors. In: 2019 Symposium on VLSI circuits. Kyoto, Japan, pp C58–C59. https://doi.org/10.23919/VLSIC.2019.8778004 Lin Q, Xu J, Song S, Breeschoten A, Konijnenburg M, Chen M, Hoof C, Tavernier F, Helleputte NV (2019) A 196μW, Reconfigurable lightto-digital converter with 119dB dynamic range, for wearable PPG/NIRS sensors. In: 2019 Symposium on VLSI circuits. Kyoto, Japan, pp C58–C59. https://​doi.​org/​10.​23919/​VLSIC.​2019.​8778004
Zurück zum Zitat Marefat F et al (2020) A 1-V 8.1 µW PPG-recording front-end with > 92-dB DR using light-to-digital conversion with signal-aware DC subtraction and ambient light removal. IEEE Solid State Circuits Lett 3:17–20CrossRef Marefat F et al (2020) A 1-V 8.1 µW PPG-recording front-end with > 92-dB DR using light-to-digital conversion with signal-aware DC subtraction and ambient light removal. IEEE Solid State Circuits Lett 3:17–20CrossRef
Zurück zum Zitat Martina JR, Westerhof BE, Goudoever JV, Beaumont EMFHde, Truijen J, Kim Y-S, Immink RV, Jöbsis DA, Hollmann MW, Lahpor JR, Mol BAJM, van Lieshout JJ (2012) Noninvasive continuous arterial blood pressure monitoring with Nexfin®. Anesthesiology 116(5):1092–1103CrossRef Martina JR, Westerhof BE, Goudoever JV, Beaumont EMFHde, Truijen J, Kim Y-S, Immink RV, Jöbsis DA, Hollmann MW, Lahpor JR, Mol BAJM, van Lieshout JJ (2012) Noninvasive continuous arterial blood pressure monitoring with Nexfin®. Anesthesiology 116(5):1092–1103CrossRef
Zurück zum Zitat Sharma M, Barbosa K, Ho V, Griggs D, Ghirmai T, Krishnan SK, Hsiai TK, Chiao J-C, Cao H (2017) Cuff-less and continuous blood pressure monitoring: a methodological review. Technologies 5(21):1–22 Sharma M, Barbosa K, Ho V, Griggs D, Ghirmai T, Krishnan SK, Hsiai TK, Chiao J-C, Cao H (2017) Cuff-less and continuous blood pressure monitoring: a methodological review. Technologies 5(21):1–22
Zurück zum Zitat Sommermeyer D, Zou D, Ficker JH, Randerath W, Fischer C, Penzel T, Sanner B, Hedner J, Grote L (2016) Detection of cardiovascular risk from a photoplethysmographic signal using a matching pursuit algorithm. Med Biol Eng Comput 54(7):1111–1121CrossRef Sommermeyer D, Zou D, Ficker JH, Randerath W, Fischer C, Penzel T, Sanner B, Hedner J, Grote L (2016) Detection of cardiovascular risk from a photoplethysmographic signal using a matching pursuit algorithm. Med Biol Eng Comput 54(7):1111–1121CrossRef
Zurück zum Zitat Suzuki S, Oguri K (2009) Cuffless blood pressure estimation by error-correcting output coding method based on an aggregation of AdaBoost with a photoplethysmograph sensor. In: 2009 Annual international conference of the IEEE engineering in medicine and biology society, pp 6765–6768 Suzuki S, Oguri K (2009) Cuffless blood pressure estimation by error-correcting output coding method based on an aggregation of AdaBoost with a photoplethysmograph sensor. In: 2009 Annual international conference of the IEEE engineering in medicine and biology society, pp 6765–6768
Zurück zum Zitat Tang Z, Tamura T, Sekine M, Huang M, Chen W, Yoshida M, Sakatani K, Kobayashi H, Kanaya S (2017) A chair-based unobtrusive cuffless blood pressure monitoring system based on pulse arrival time. IEEE J Biomed Health Inf 21(5):1194–1205CrossRef Tang Z, Tamura T, Sekine M, Huang M, Chen W, Yoshida M, Sakatani K, Kobayashi H, Kanaya S (2017) A chair-based unobtrusive cuffless blood pressure monitoring system based on pulse arrival time. IEEE J Biomed Health Inf 21(5):1194–1205CrossRef
Zurück zum Zitat Yan C et al (2019) Novel deep convolutional neural network for cuff-less blood pressure measurement using ECG and PPG signals. In: 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). Berlin, pp 1917–1920. https://doi.org/10.1109/EMBC.2019.8857108 Yan C et al (2019) Novel deep convolutional neural network for cuff-less blood pressure measurement using ECG and PPG signals. In: 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). Berlin, pp 1917–1920. https://​doi.​org/​10.​1109/​EMBC.​2019.​8857108
Zurück zum Zitat Wang L, Zhou W, Xing Y, Zhou X (2018) A novel neural network model for blood pressure estimation using photoplethesmography without electrocardiogram. J Healthc Eng 2018:7804243CrossRef Wang L, Zhou W, Xing Y, Zhou X (2018) A novel neural network model for blood pressure estimation using photoplethesmography without electrocardiogram. J Healthc Eng 2018:7804243CrossRef
Zurück zum Zitat Zhang Y, Feng Z (2017) A SVM method for continuous blood pressure estimation from a PPG signal. In: Proceedings of the 9th international conference on machine learning and computing (ICMLC 2017). Association for computing machinery. New York, NY, USA, pp 128–132. https://doi.org/10.1145/3055635.3056634 Zhang Y, Feng Z (2017) A SVM method for continuous blood pressure estimation from a PPG signal. In: Proceedings of the 9th international conference on machine learning and computing (ICMLC 2017). Association for computing machinery. New York, NY, USA, pp 128–132. https://​doi.​org/​10.​1145/​3055635.​3056634
Zurück zum Zitat Zheng Y, Yan B, Zhang Y, Poon C (2014) An armband wearable device for overnight and cuff-less blood pressure measurement. IEEE Trans Biomed Eng 61:2179–2186CrossRef Zheng Y, Yan B, Zhang Y, Poon C (2014) An armband wearable device for overnight and cuff-less blood pressure measurement. IEEE Trans Biomed Eng 61:2179–2186CrossRef
Metadaten
Titel
Design and implementation of a photoplethysmography acquisition system with an optimized artificial neural network for accurate blood pressure measurement
verfasst von
Rajeev Kumar Pandey
Tse-Yu Lin
Paul C.-P. Chao
Publikationsdatum
04.01.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
Microsystem Technologies / Ausgabe 6/2021
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-020-05109-9

Weitere Artikel der Ausgabe 6/2021

Microsystem Technologies 6/2021 Zur Ausgabe

Neuer Inhalt