Abstract

In brain surgery procedures, such as deep brain stimulation, drug-resistant epilepsy and tumour surgery, the patient is intentionally awakened to map functional neural bases via electrophysiological assessment. This assessment can involve patient’s body movements; thus, increasing the mechanical load on the head-restraint systems used for keeping the skull still during the surgery. The loads exchanged between the head and the restraining device can potentially result into skin and bone damage. The aim of this work is to assess such loads for laying down the requirements of a surgical robotics system for dynamic head movements compensation by fast moving arms and by an active restraint able to damp such actions. A Mayfield® head clamp was tracked and instrumented with strain gages (SGs). SG locations were chosen according to finite element analyses. During an actual brain surgery, displacements and strains were measured and clustered according to events that generated them. Loads were inferred from strain data. The greatest force components were exerted vertically (median 5.5 N, maximum 151.87 N) with frequencies up to 1.5 Hz. Maximum measured displacement and velocity were 9 mm and 60 mm/s, with frequencies up to 2.8 Hz. The analysis of loads and displacements allowed to identify the surgery steps causing maximal loads on the head-restraint device.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Chao L, Chen K (1997) Shape optimal design and force sensitivity evaluation of six-axis force sensors. Sens Actuators A 63:105–112CrossRef Chao L, Chen K (1997) Shape optimal design and force sensitivity evaluation of six-axis force sensors. Sens Actuators A 63:105–112CrossRef
2.
Zurück zum Zitat D’Amico M, Ferrigno G (1990) Technique for the evaluation of derivatives from noisy biomechanical displacement data using a model-based bandwidth-selection procedure. Med Biol Eng Comput 28:407–415PubMedCrossRef D’Amico M, Ferrigno G (1990) Technique for the evaluation of derivatives from noisy biomechanical displacement data using a model-based bandwidth-selection procedure. Med Biol Eng Comput 28:407–415PubMedCrossRef
3.
Zurück zum Zitat De Lorenzo D, De Momi E, Dyagilev I, Manganelli R, Formaglio A, Prattichizzo D, Shoham M, Ferrigno G (2011) Force feedback in a piezoelectric linear actuator for neurosurgery. Int J Med Robot Comput Assisted Surg 7:268–275 De Lorenzo D, De Momi E, Dyagilev I, Manganelli R, Formaglio A, Prattichizzo D, Shoham M, Ferrigno G (2011) Force feedback in a piezoelectric linear actuator for neurosurgery. Int J Med Robot Comput Assisted Surg 7:268–275
4.
Zurück zum Zitat Donaldson N, Munih M, Perkins T, Wood D (1999) Apparatus to measure simultaneously 14 isometric leg joint moments. Part 1: design and calibration of six-axis transducers for the forces and moments at the ankle. Med Biol Eng Comput 37:137–147PubMedCrossRef Donaldson N, Munih M, Perkins T, Wood D (1999) Apparatus to measure simultaneously 14 isometric leg joint moments. Part 1: design and calibration of six-axis transducers for the forces and moments at the ankle. Med Biol Eng Comput 37:137–147PubMedCrossRef
5.
Zurück zum Zitat Dreier JD, Williams B, Mangar D, Camporesi EM (2009) Patients selection in awake neurosurgery. HSR Proc Intensive Care Cardiovasc Anesth 30:19–27 Dreier JD, Williams B, Mangar D, Camporesi EM (2009) Patients selection in awake neurosurgery. HSR Proc Intensive Care Cardiovasc Anesth 30:19–27
6.
Zurück zum Zitat Duffau H (2005) Lessons from brain mapping in surgery for low-grade glioma: insights into associations between tumour and brain plasticity. Lancet Neurol 4:476–486PubMedCrossRef Duffau H (2005) Lessons from brain mapping in surgery for low-grade glioma: insights into associations between tumour and brain plasticity. Lancet Neurol 4:476–486PubMedCrossRef
7.
Zurück zum Zitat Ferrigno G, Baroni G, Casolo F, De Momi E, Gini G, Matteucci M, Pedrocchi A (2011) Medical robotics. Pulse IEEE 2:55–61CrossRef Ferrigno G, Baroni G, Casolo F, De Momi E, Gini G, Matteucci M, Pedrocchi A (2011) Medical robotics. Pulse IEEE 2:55–61CrossRef
8.
Zurück zum Zitat Hemm S, Werdell K (2010) Stereotactic implantation of deep brain stimulation electrodes: a review of technical systems, methods and emerging tools. Med Biol Eng Comput 48:611–624PubMedCrossRef Hemm S, Werdell K (2010) Stereotactic implantation of deep brain stimulation electrodes: a review of technical systems, methods and emerging tools. Med Biol Eng Comput 48:611–624PubMedCrossRef
9.
Zurück zum Zitat Lee M, Rezai AR, Chou J (1994) Depressed skull fractures in children secondary to skull clamp fixation devices. Pediatr Neurosurg 21:174–7; discussion 178 Lee M, Rezai AR, Chou J (1994) Depressed skull fractures in children secondary to skull clamp fixation devices. Pediatr Neurosurg 21:174–7; discussion 178
10.
Zurück zum Zitat Lee MJ, Lin EL (2010) The use of the three-pronged Mayfield head clamp resulting in an intracranial epidural hematoma in an adult patient. Eur Spine J 19(Suppl 2):S187–S189PubMedCrossRef Lee MJ, Lin EL (2010) The use of the three-pronged Mayfield head clamp resulting in an intracranial epidural hematoma in an adult patient. Eur Spine J 19(Suppl 2):S187–S189PubMedCrossRef
11.
Zurück zum Zitat Liker MA, Won DS, Rao VY, Hua SE (2008) Deep brain stimulation: an evolving technology. Proc IEEE 96:1129–1141CrossRef Liker MA, Won DS, Rao VY, Hua SE (2008) Deep brain stimulation: an evolving technology. Proc IEEE 96:1129–1141CrossRef
12.
Zurück zum Zitat Liu SA, Tzo HL (2002) A novel six-component force sensor of good measurement isotropy and sensitivities. Sens Actuators A 100:223–230CrossRef Liu SA, Tzo HL (2002) A novel six-component force sensor of good measurement isotropy and sensitivities. Sens Actuators A 100:223–230CrossRef
13.
Zurück zum Zitat Malosio, M, Negri SP, Pedrocchi N, Vicentini F, Cardinale F, Tosatti LM (2012) The kinematic architecture of the active headframe: a new head support for awake brain surgery. In: Proceedings of the 34th annual international conference of the engineering in medicine and biology society, San Diego, USA Malosio, M, Negri SP, Pedrocchi N, Vicentini F, Cardinale F, Tosatti LM (2012) The kinematic architecture of the active headframe: a new head support for awake brain surgery. In: Proceedings of the 34th annual international conference of the engineering in medicine and biology society, San Diego, USA
14.
Zurück zum Zitat Mandir AS, Rowland LH, Dougherty PM, Lenz FA (1997) Microelectrode recording and stimulation techniques during stereotactic procedures in the thalamus and pallidum. Adv Neurol 74:159–165PubMed Mandir AS, Rowland LH, Dougherty PM, Lenz FA (1997) Microelectrode recording and stimulation techniques during stereotactic procedures in the thalamus and pallidum. Adv Neurol 74:159–165PubMed
15.
Zurück zum Zitat Olivier PE, Du Toit DE (2008) Isokinetic neck strength profile of senior elite rugby union players. J Sci Med Sport 11:96–105PubMedCrossRef Olivier PE, Du Toit DE (2008) Isokinetic neck strength profile of senior elite rugby union players. J Sci Med Sport 11:96–105PubMedCrossRef
16.
Zurück zum Zitat Puangmali P, Althoefer K, Seneviratne LD, Murphy D, Dasgupta P (2008) State-of-the-art in force and tactile sensing for minimally invasive surgery. Sens J IEEE 8:371–381CrossRef Puangmali P, Althoefer K, Seneviratne LD, Murphy D, Dasgupta P (2008) State-of-the-art in force and tactile sensing for minimally invasive surgery. Sens J IEEE 8:371–381CrossRef
17.
Zurück zum Zitat Rezasoltani A, Ylinen J, Bakhtiary AH, Norozi M, Montazeri M (2008) Cervical muscle strength measurement is dependent on the location of thoracic support. Br J Sports Med 42:379–382PubMedCrossRef Rezasoltani A, Ylinen J, Bakhtiary AH, Norozi M, Montazeri M (2008) Cervical muscle strength measurement is dependent on the location of thoracic support. Br J Sports Med 42:379–382PubMedCrossRef
18.
Zurück zum Zitat Rozet I, Vavilala MS (2007) Risks and benefits of patient positioning during neurosurgical care. Anesthesiol Clin 25:631–653PubMedCrossRef Rozet I, Vavilala MS (2007) Risks and benefits of patient positioning during neurosurgical care. Anesthesiol Clin 25:631–653PubMedCrossRef
19.
Zurück zum Zitat Seng KY, Lee Peter VS, Lam PM (2002) Neck muscle strength across the sagittal and coronal planes: an isometric study. Clin Biomech (Bristol, Avon) 17:545–547 Seng KY, Lee Peter VS, Lam PM (2002) Neck muscle strength across the sagittal and coronal planes: an isometric study. Clin Biomech (Bristol, Avon) 17:545–547
20.
Zurück zum Zitat Serramito-Garcia R, Arcos-Algaba A, Santin-Amo JM, Garcia-Allut A, Bandin-Dieguez FJ, Gelabert-Gonzalez M (2009) Epidural haematoma due to an headrest in an adult. Neurocirugia (Astur) 20:567–570 Serramito-Garcia R, Arcos-Algaba A, Santin-Amo JM, Garcia-Allut A, Bandin-Dieguez FJ, Gelabert-Gonzalez M (2009) Epidural haematoma due to an headrest in an adult. Neurocirugia (Astur) 20:567–570
21.
Zurück zum Zitat Szelenyi A, Bello L, Duffau H, Fava E, Feigl GC, Galanda M, Neuloh G, Signorelli F, Sala F, Workgroup for Intraoperative Management in Low-Grade Glioma Surgery within the European Low-Grade Glioma Network (2010) Intraoperative electrical stimulation in awake craniotomy: methodological aspects of current practice. Neurosurg Focus 28:E7 Szelenyi A, Bello L, Duffau H, Fava E, Feigl GC, Galanda M, Neuloh G, Signorelli F, Sala F, Workgroup for Intraoperative Management in Low-Grade Glioma Surgery within the European Low-Grade Glioma Network (2010) Intraoperative electrical stimulation in awake craniotomy: methodological aspects of current practice. Neurosurg Focus 28:E7
22.
Zurück zum Zitat Trejos AL, Patel RV, Naish MD (2010) Force sensing and its application in minimally invasive surgery and therapy: a survey. Proc Inst Mech Eng Part C J Mech Eng Sci 224:1435–1454CrossRef Trejos AL, Patel RV, Naish MD (2010) Force sensing and its application in minimally invasive surgery and therapy: a survey. Proc Inst Mech Eng Part C J Mech Eng Sci 224:1435–1454CrossRef
23.
Zurück zum Zitat Vasavada AN, Li S, Delp SL (2001) Three-dimensional isometric strength of neck muscles in humans. Spine (Phila Pa 1976) 26:1904–1909 Vasavada AN, Li S, Delp SL (2001) Three-dimensional isometric strength of neck muscles in humans. Spine (Phila Pa 1976) 26:1904–1909
24.
Zurück zum Zitat Wang Z, Peng C, Zheng X, Wang P, Wang G (1997) Force measurement on fracture site with external fixation. Med Biol Eng Comput 35:289–290PubMedCrossRef Wang Z, Peng C, Zheng X, Wang P, Wang G (1997) Force measurement on fracture site with external fixation. Med Biol Eng Comput 35:289–290PubMedCrossRef
Metadaten
Titel
Intraoperative forces and moments analysis on patient head clamp during awake brain surgery
verfasst von
Danilo De Lorenzo
Elena De Momi
Lorenzo Conti
Emiliano Votta
Marco Riva
Enrica Fava
Lorenzo Bello
Giancarlo Ferrigno
Publikationsdatum
01.03.2013
Verlag
Springer-Verlag
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 3/2013
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-012-1002-9

Weitere Artikel der Ausgabe 3/2013

Medical & Biological Engineering & Computing 3/2013 Zur Ausgabe

Premium Partner