Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 7/2012

01.07.2012 | Original Article

Optimal features for online seizure detection

verfasst von: Lojini Logesparan, Alexander J. Casson, Esther Rodriguez-Villegas

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 7/2012

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This study identifies characteristic features in scalp EEG that simultaneously give the best discrimination between epileptic seizures and background EEG in minimally pre-processed scalp data; and have minimal computational complexity to be suitable for online, real-time analysis. The discriminative performance of 65 previously reported features has been evaluated in terms of sensitivity, specificity, area under the sensitivity–specificity curve (AUC), and relative computational complexity, on 47 seizures (split in 2,698 2 s sections) in over 172 h of scalp EEG from 24 adults. The best performing features are line length and relative power in the 12.5–25 Hz band. Relative power has a better seizure detection performance (AUC = 0.83; line length AUC = 0.77), but is calculated after the discrete wavelet transform and is thus more computationally complex. Hence, relative power achieves the best performance for offline detection, whilst line length would be preferable for online low complexity detection. These results, from the largest systematic study of seizure detection features, aid future researchers in selecting an optimal set of features when designing algorithms for both standard offline detection and new online low computational complexity detectors.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Agostinho PR, Haddad S, De Lima JA, Serdijn WA, Saotome O (2008) An ultra low power CMOS pA/V transconductor and its application to wavelet filters. Analog Integr Circ Sig Process 57:19–27CrossRef Agostinho PR, Haddad S, De Lima JA, Serdijn WA, Saotome O (2008) An ultra low power CMOS pA/V transconductor and its application to wavelet filters. Analog Integr Circ Sig Process 57:19–27CrossRef
2.
Zurück zum Zitat Badawy RAB, Pillay N, Jettec N, Wiebec S, Federico P (2011) A blinded comparison of continuous versus sampled review of video-EEG monitoring data. Clin Neurophysiol 122:1086–1090PubMedCrossRef Badawy RAB, Pillay N, Jettec N, Wiebec S, Federico P (2011) A blinded comparison of continuous versus sampled review of video-EEG monitoring data. Clin Neurophysiol 122:1086–1090PubMedCrossRef
3.
Zurück zum Zitat Casson AJ, Yates DC, Smith SJ, Duncan JS, Rodriguez-Villegas E (2010) Wearable electroencephalography. IEEE EMBS Mag 29:44–56 Casson AJ, Yates DC, Smith SJ, Duncan JS, Rodriguez-Villegas E (2010) Wearable electroencephalography. IEEE EMBS Mag 29:44–56
4.
Zurück zum Zitat Casson AJ, Rodriguez-Villegas E (2011) A 60 pW gmC continuous wavelet transform circuit for portable EEG systems. J Solid-State Circuits 46:1406–1415CrossRef Casson AJ, Rodriguez-Villegas E (2011) A 60 pW gmC continuous wavelet transform circuit for portable EEG systems. J Solid-State Circuits 46:1406–1415CrossRef
5.
Zurück zum Zitat DeClercq W, Vergult A, Vanrumste B, Van Paesschen W, Van Huffel S (2006) Canonical correlation analysis applied to remove muscle artifacts from the electroencephalogram. IEEE Trans Biomed Eng 53:2583–2587CrossRef DeClercq W, Vergult A, Vanrumste B, Van Paesschen W, Van Huffel S (2006) Canonical correlation analysis applied to remove muscle artifacts from the electroencephalogram. IEEE Trans Biomed Eng 53:2583–2587CrossRef
6.
Zurück zum Zitat Faul S, Temko A, Marnane W (2009) Age-independent seizure detection. In: Proceedings of the 31st international conference of IEEE Engineering Medicine Biology Society, Minnesota. IEEE, Piscataway, pp 6612–6615 Faul S, Temko A, Marnane W (2009) Age-independent seizure detection. In: Proceedings of the 31st international conference of IEEE Engineering Medicine Biology Society, Minnesota. IEEE, Piscataway, pp 6612–6615
7.
Zurück zum Zitat Goncharova II, McFarland DJ, Vaughan TM, Wolpaw JR (2003) EMG contamination of EEG: spectral and topographical characteristics. Clin Neurophysiol 114:1580–1593PubMedCrossRef Goncharova II, McFarland DJ, Vaughan TM, Wolpaw JR (2003) EMG contamination of EEG: spectral and topographical characteristics. Clin Neurophysiol 114:1580–1593PubMedCrossRef
8.
Zurück zum Zitat Gotman J, Ives JR, Gloor P (1981) Frequency content of EEG and EMG at seizure onset: possibility of removal of EMG artefact by digital filtering. Electroenceph Clin Neurophysiol 52:626–639PubMedCrossRef Gotman J, Ives JR, Gloor P (1981) Frequency content of EEG and EMG at seizure onset: possibility of removal of EMG artefact by digital filtering. Electroenceph Clin Neurophysiol 52:626–639PubMedCrossRef
9.
10.
Zurück zum Zitat Greene BR, Faul S, Marnane WP, Lightbody G, Korotchikova I, Boylan GB (2008) A comparison of quantitative EEG features for neonatal seizure detection. Clin Neurophysiol 119:1248–1261PubMedCrossRef Greene BR, Faul S, Marnane WP, Lightbody G, Korotchikova I, Boylan GB (2008) A comparison of quantitative EEG features for neonatal seizure detection. Clin Neurophysiol 119:1248–1261PubMedCrossRef
11.
Zurück zum Zitat Guerrero-Mosquera C, Trigueros AM, Fraco JI, Navia-Vàzquez A (2010) New feature extraction approach for epileptic EEG signal detection using time-frequency distributions. Med Biol Eng Comput 48:321–333PubMedCrossRef Guerrero-Mosquera C, Trigueros AM, Fraco JI, Navia-Vàzquez A (2010) New feature extraction approach for epileptic EEG signal detection using time-frequency distributions. Med Biol Eng Comput 48:321–333PubMedCrossRef
12.
Zurück zum Zitat Hall CW Jr, Sarkar A (2011) Mutual information in natural position order of electroencephalogram is significantly increased at seizure onset. Med Biol Eng Comput 49:133–141PubMedCrossRef Hall CW Jr, Sarkar A (2011) Mutual information in natural position order of electroencephalogram is significantly increased at seizure onset. Med Biol Eng Comput 49:133–141PubMedCrossRef
13.
Zurück zum Zitat Harreby KR, Sevcencu C, Struijik JJ (2011) Early seizure detection in rats based on vagus nerve activity. Med Biol Eng Comput 49:143–151PubMedCrossRef Harreby KR, Sevcencu C, Struijik JJ (2011) Early seizure detection in rats based on vagus nerve activity. Med Biol Eng Comput 49:143–151PubMedCrossRef
14.
Zurück zum Zitat Hongmin L, Yigang H, Sun Y (2008) Detection of cardiac signal characteristic point using log-domain wavelet transform circuits. Circuits Syst Signal Process 27:683–698CrossRef Hongmin L, Yigang H, Sun Y (2008) Detection of cardiac signal characteristic point using log-domain wavelet transform circuits. Circuits Syst Signal Process 27:683–698CrossRef
15.
Zurück zum Zitat Kamboh AM, Raetz M, Oweiss KG, Mason A (2007) Area-power efficient VLSI implementation of multichannel DWT for data compression in implantable neuroprosthetics. IEEE Trans Biomed Circ Syst 1:128–135CrossRef Kamboh AM, Raetz M, Oweiss KG, Mason A (2007) Area-power efficient VLSI implementation of multichannel DWT for data compression in implantable neuroprosthetics. IEEE Trans Biomed Circ Syst 1:128–135CrossRef
16.
Zurück zum Zitat Kelly KM, Shiaud DS, Kernd RT, Chiend JH, Yang MCK, Yandora KA, Valeriano JP, Halford JJ, Sackellares JC (2010) Assessment of a scalp EEG-based automated seizure detection system. Clin Neurphysiol 121:1832–1843CrossRef Kelly KM, Shiaud DS, Kernd RT, Chiend JH, Yang MCK, Yandora KA, Valeriano JP, Halford JJ, Sackellares JC (2010) Assessment of a scalp EEG-based automated seizure detection system. Clin Neurphysiol 121:1832–1843CrossRef
17.
Zurück zum Zitat Kim H, Rosen J (2010) Epileptic seizure detection—an AR model based algorithm for implantable device. In: Proceedings of the 32nd international conference of IEEE Engineering Medicine Biology Society, Buenos Aires. IEEE, Piscataway, p 5541 Kim H, Rosen J (2010) Epileptic seizure detection—an AR model based algorithm for implantable device. In: Proceedings of the 32nd international conference of IEEE Engineering Medicine Biology Society, Buenos Aires. IEEE, Piscataway, p 5541
18.
Zurück zum Zitat Koubeissi MZ, Syed TU (2011) Inpatient video-EEG monitoring: how much shall we review? Clin Neurophysiol 122:1065–1066PubMedCrossRef Koubeissi MZ, Syed TU (2011) Inpatient video-EEG monitoring: how much shall we review? Clin Neurophysiol 122:1065–1066PubMedCrossRef
19.
Zurück zum Zitat Kuhlmann L, Cook MJ, Fuller K, Grayden DB, Burkitt AN, Mareels IMY (2008) Correlation analysis of seizure detection features. In: Proceedings of the international conference on intelligent sensors, sensor networks and information processing, Sydney. IEEE, Piscataway, pp 309–314 Kuhlmann L, Cook MJ, Fuller K, Grayden DB, Burkitt AN, Mareels IMY (2008) Correlation analysis of seizure detection features. In: Proceedings of the international conference on intelligent sensors, sensor networks and information processing, Sydney. IEEE, Piscataway, pp 309–314
20.
Zurück zum Zitat Kuhlmann L, Burkitt AN, Cook MJ, Fuller K, Grayden DB, Seiderer L, Mareels IMY (2009) Seizure detection using seizure probability estimation: comparison of features used to detect seizures. Ann Biomed Eng 37:2129–2145PubMedCrossRef Kuhlmann L, Burkitt AN, Cook MJ, Fuller K, Grayden DB, Seiderer L, Mareels IMY (2009) Seizure detection using seizure probability estimation: comparison of features used to detect seizures. Ann Biomed Eng 37:2129–2145PubMedCrossRef
21.
Zurück zum Zitat Lesser RP (2009) Epilepsy: does continuous EEG monitoring improve seizure control? Nat Rev Neurol 5:581–582PubMedCrossRef Lesser RP (2009) Epilepsy: does continuous EEG monitoring improve seizure control? Nat Rev Neurol 5:581–582PubMedCrossRef
22.
Zurück zum Zitat McEvoy RP, Faul S, Marnane WP (2010) Ambulatory REACT: real-time seizure detection with a DSP microprocessor. In: Proceedings of the international conference of IEEE Engineering Medicine Biology Society, Buenos Aires. IEEE, Piscataway, pp 2443–2444 McEvoy RP, Faul S, Marnane WP (2010) Ambulatory REACT: real-time seizure detection with a DSP microprocessor. In: Proceedings of the international conference of IEEE Engineering Medicine Biology Society, Buenos Aires. IEEE, Piscataway, pp 2443–2444
23.
Zurück zum Zitat Narasimhan S, Chiel HJ, Bhunia S (2010) Ultra-low-power and robust digital-signal-processing hardware for implantable neural interface microsystems. IEEE Trans Biomed Circ Syst 4:1–10CrossRef Narasimhan S, Chiel HJ, Bhunia S (2010) Ultra-low-power and robust digital-signal-processing hardware for implantable neural interface microsystems. IEEE Trans Biomed Circ Syst 4:1–10CrossRef
24.
Zurück zum Zitat Nuwer MR, Comi G, Emerson R, Fuglsang-Frederiksen A, Guerit J, Hinrichs H, Ikeda A, Luccas FJC, Rappelsburger P (1998) IFCN standards for digital recording of clinical EEG. Electroenceph Clin Neurophysiol 106:259–261PubMedCrossRef Nuwer MR, Comi G, Emerson R, Fuglsang-Frederiksen A, Guerit J, Hinrichs H, Ikeda A, Luccas FJC, Rappelsburger P (1998) IFCN standards for digital recording of clinical EEG. Electroenceph Clin Neurophysiol 106:259–261PubMedCrossRef
25.
Zurück zum Zitat O’Donnell RD, Berkhout J, Adey WR (1974) Contamination of scalp EEG spectrum during contraction of cranio-facial muscles. Electroencephalogr Clin Neurophysiol 37:145–151PubMedCrossRef O’Donnell RD, Berkhout J, Adey WR (1974) Contamination of scalp EEG spectrum during contraction of cranio-facial muscles. Electroencephalogr Clin Neurophysiol 37:145–151PubMedCrossRef
26.
Zurück zum Zitat Raghunathan S, Gupta SK, Markandeya HS, Roya K, Irazoqui PP (2010) A hardware-algorithm co-design approach to optimize seizure detection algorithms for implantable applications. J Neurosci Methods 1:106–117CrossRef Raghunathan S, Gupta SK, Markandeya HS, Roya K, Irazoqui PP (2010) A hardware-algorithm co-design approach to optimize seizure detection algorithms for implantable applications. J Neurosci Methods 1:106–117CrossRef
27.
Zurück zum Zitat Shiau D, Halford JJ, Kelly KM, Kern RT, Inman M, Chien J, Pardalos PM, Yang MCK, Sackellares JC (2010) Signal regularity-based automated seizure detection system for scalp EEG monitoring. Cybern Syst Anal 46:922–935PubMedCrossRef Shiau D, Halford JJ, Kelly KM, Kern RT, Inman M, Chien J, Pardalos PM, Yang MCK, Sackellares JC (2010) Signal regularity-based automated seizure detection system for scalp EEG monitoring. Cybern Syst Anal 46:922–935PubMedCrossRef
28.
Zurück zum Zitat Sisodiya S (2007) Etiology and management of refractory epilepsies. Nat Clin Pract Neuro 3:320–330CrossRef Sisodiya S (2007) Etiology and management of refractory epilepsies. Nat Clin Pract Neuro 3:320–330CrossRef
29.
Zurück zum Zitat Tito M, Cabrerizo M, Ayala M, Jayakar P, Adjouadi M (2009) Seizure detection: an assessment of time- and frequency-based features in a unified two-dimensional decisional space using nonlinear decision functions. J Clin Neurophysiol 26:381–391PubMedCrossRef Tito M, Cabrerizo M, Ayala M, Jayakar P, Adjouadi M (2009) Seizure detection: an assessment of time- and frequency-based features in a unified two-dimensional decisional space using nonlinear decision functions. J Clin Neurophysiol 26:381–391PubMedCrossRef
30.
Zurück zum Zitat van Putten MJAM, Kind T, Visser F, Lagerburg V (2005) Detecting temporal lobe seizures from scalp EEG recordings: a comparison of various features. Clin Neurophysiol 116:2480–2489PubMedCrossRef van Putten MJAM, Kind T, Visser F, Lagerburg V (2005) Detecting temporal lobe seizures from scalp EEG recordings: a comparison of various features. Clin Neurophysiol 116:2480–2489PubMedCrossRef
31.
Zurück zum Zitat Vergult A, De Clercq Q, Palmini A, Vanrumste B, Dupont P, Van Huffel S, Van Paesschen W (2007) Improving the Interpretation of Ictal Scalp EEG: BSS-CCA algorithm for muscle artifact removal. Epilepsia 48:950–958PubMedCrossRef Vergult A, De Clercq Q, Palmini A, Vanrumste B, Dupont P, Van Huffel S, Van Paesschen W (2007) Improving the Interpretation of Ictal Scalp EEG: BSS-CCA algorithm for muscle artifact removal. Epilepsia 48:950–958PubMedCrossRef
32.
Zurück zum Zitat Verma N, Shoeb A, Bohorquez J, Dawson J, Guttag J, Chandrakasan AP (2010) A micro-power EEG acquisition SoC with integrated feature extraction processor for a chronic seizure detection system. J Solid-State Circuits 45:804–816CrossRef Verma N, Shoeb A, Bohorquez J, Dawson J, Guttag J, Chandrakasan AP (2010) A micro-power EEG acquisition SoC with integrated feature extraction processor for a chronic seizure detection system. J Solid-State Circuits 45:804–816CrossRef
33.
Zurück zum Zitat Wang A, Chandrakasan AP (2005) A 180-mV subthreshold FFT processor using a minimum energy design methodology. IEEE J Solid-State Circuits 40:310–319CrossRef Wang A, Chandrakasan AP (2005) A 180-mV subthreshold FFT processor using a minimum energy design methodology. IEEE J Solid-State Circuits 40:310–319CrossRef
34.
Zurück zum Zitat Zandi AS, Javidan M, Dumont GA, Tafreshi R (2010) Automated real-time epileptic seizure detection in scalp EEG recordings using an algorithm based on wavelet packet transform. IEEE Trans Biomed Eng 57:1639–1651PubMedCrossRef Zandi AS, Javidan M, Dumont GA, Tafreshi R (2010) Automated real-time epileptic seizure detection in scalp EEG recordings using an algorithm based on wavelet packet transform. IEEE Trans Biomed Eng 57:1639–1651PubMedCrossRef
35.
Zurück zum Zitat Zweig MH, Campbell G (1993) Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine. Clin Chem 39:561–577PubMed Zweig MH, Campbell G (1993) Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine. Clin Chem 39:561–577PubMed
Metadaten
Titel
Optimal features for online seizure detection
verfasst von
Lojini Logesparan
Alexander J. Casson
Esther Rodriguez-Villegas
Publikationsdatum
01.07.2012
Verlag
Springer-Verlag
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 7/2012
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-012-0904-x

Weitere Artikel der Ausgabe 7/2012

Medical & Biological Engineering & Computing 7/2012 Zur Ausgabe

Premium Partner