01.03.2007 | Technical Paper

A piezoelectric micro-cantilever bio-sensor using the mass-micro-balancing technique with self-excitation

verfasst von: Yeolho Lee, Geunbae Lim, Wonkyu Moon

Erschienen in: Microsystem Technologies | Ausgabe 5-6/2007

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

A biosensor was developed for using in a Lab-On-a-Chip (LOC). The sensor detects the change in the resonance frequency of a micro-cantilever with a piezoelectric film. This is the mass micro-balancing technique, which has been successfully used for detecting bio-materials in the quartz crystal microbalance (QCM). The PZT film, a piezoelectric film, is designed to act as both sensor and actuator. The geometry of the micro cantilever is optimized to maximize the sensitivity and minimize the environmental effects such as viscous damping and added mass effect in liquid. The fabricated sensor is composed of a 100 μm long, 30 μm wide, and 5 μm thick cantilever with a 2.5 μm thick piezoelectric (PZT) layer on it. The ratio of thickness to length of the micro cantilever is very high compared to others in micro cantilever-based studies. This high aspect ratio is the key to maximize the sensitivity and minimize the environmental effects. The fabricated micro sensor was tested by detecting the mussel gluing protein, the insulin-anti insulin binding protein and the poly T-sequence DNA.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Baselt David R, Lee Gil U, Colton Richard J (1996) Biosensor based on force microscope technology. J Vac Sci Technol B 14:789–793CrossRef Baselt David R, Lee Gil U, Colton Richard J (1996) Biosensor based on force microscope technology. J Vac Sci Technol B 14:789–793CrossRef
Zurück zum Zitat Baselt David R, Lee Gil U, Hansen Karolyn M, Chrisey Linda A, Colton Richard J (1997) A high-sensitivity micromachined biosensor. Proc IEEE 85(4):672–680CrossRef Baselt David R, Lee Gil U, Hansen Karolyn M, Chrisey Linda A, Colton Richard J (1997) A high-sensitivity micromachined biosensor. Proc IEEE 85(4):672–680CrossRef
Zurück zum Zitat Battiston FM, Ramseyer JP, Lang HP, Baller MK, Gerber C, Gimzewski JK, Meyer E, Güntherodt HJ (2001) A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout. Sens Actuators B 77(1–2):122–131CrossRef Battiston FM, Ramseyer JP, Lang HP, Baller MK, Gerber C, Gimzewski JK, Meyer E, Güntherodt HJ (2001) A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout. Sens Actuators B 77(1–2):122–131CrossRef
Zurück zum Zitat Blevins Robert D (1990) Flow-induced vibration, 2nd edn. Van Nostrand Reinhold, New York Blevins Robert D (1990) Flow-induced vibration, 2nd edn. Van Nostrand Reinhold, New York
Zurück zum Zitat Ferrari V, Marioli D, Taroni A, Ranucci E, Ferruti P (1996) Development and application of mass sensors based on flexural resonances in alumina beams. IEEE Trans Ultrason Ferroelectr Freq Control 43(4):601–608CrossRef Ferrari V, Marioli D, Taroni A, Ranucci E, Ferruti P (1996) Development and application of mass sensors based on flexural resonances in alumina beams. IEEE Trans Ultrason Ferroelectr Freq Control 43(4):601–608CrossRef
Zurück zum Zitat Ilic B, Czaplewski D, Craighead HG, Neuzil P, Campagnolo C, Batt C (2000) Mechanical resonant immunospecific biological detector. Appl Phys Lett 77:450–452CrossRef Ilic B, Czaplewski D, Craighead HG, Neuzil P, Campagnolo C, Batt C (2000) Mechanical resonant immunospecific biological detector. Appl Phys Lett 77:450–452CrossRef
Zurück zum Zitat Kim BH, Maute M, Prins FE, Kern DP, Croitoru M, Raible S, Weimar U, Göpel W (2000) Parallel frequency readout of an array of mass-sensitive transducers for sensor applications. Microelectron Eng 53(1–4):229–232CrossRef Kim BH, Maute M, Prins FE, Kern DP, Croitoru M, Raible S, Weimar U, Göpel W (2000) Parallel frequency readout of an array of mass-sensitive transducers for sensor applications. Microelectron Eng 53(1–4):229–232CrossRef
Zurück zum Zitat Lavrik Nickolay V, Datskos Panos G (2003) Femtogram mass detection using photothermally actuated nanomechanical resonators. Appl Phys Lett 82:2697–2699CrossRef Lavrik Nickolay V, Datskos Panos G (2003) Femtogram mass detection using photothermally actuated nanomechanical resonators. Appl Phys Lett 82:2697–2699CrossRef
Zurück zum Zitat Lee Chengkuo, Itoh Toshihiro, Suga Tadatomo (1999) Self-excited piezoelectric PZT microcantilevers for dynamic SFM-with inherent sensing and actuating capabilities. Sens Actuators A 72(2):179–188CrossRef Lee Chengkuo, Itoh Toshihiro, Suga Tadatomo (1999) Self-excited piezoelectric PZT microcantilevers for dynamic SFM-with inherent sensing and actuating capabilities. Sens Actuators A 72(2):179–188CrossRef
Zurück zum Zitat Maute M, Raible S, Prins FE, Kern DP, Weimar U, Göpel W (1999) Fabrication and application of polymer coated cantilevers as gas sensors. Microelectron Eng 46(1–4):439–442CrossRef Maute M, Raible S, Prins FE, Kern DP, Weimar U, Göpel W (1999) Fabrication and application of polymer coated cantilevers as gas sensors. Microelectron Eng 46(1–4):439–442CrossRef
Zurück zum Zitat Miyahara Y, Deschler M, Fujii T, Watanabe S, Bleuler H (2002) Non-contact atomic force microscope with a PZT cantilever used for deflection sensing, direct oscillation and feedback actuation. Appl Surf Sci 188(3–4):450–455CrossRef Miyahara Y, Deschler M, Fujii T, Watanabe S, Bleuler H (2002) Non-contact atomic force microscope with a PZT cantilever used for deflection sensing, direct oscillation and feedback actuation. Appl Surf Sci 188(3–4):450–455CrossRef
Zurück zum Zitat Pilkey Walter D (1994) Stress, strain and structural matrices. Wiley, New York Pilkey Walter D (1994) Stress, strain and structural matrices. Wiley, New York
Zurück zum Zitat Rao Singiresu S (1995) Mechanical vibrations. 3rd edn. Addison-Wesley, Reading Rao Singiresu S (1995) Mechanical vibrations. 3rd edn. Addison-Wesley, Reading
Zurück zum Zitat Su Ming, Li Shuyou, Dravid Vinayak P (2003) Microcantilever resonance-based DNA detection with nanoparticle probes. Appl Phys Lett 82:3562–3564CrossRef Su Ming, Li Shuyou, Dravid Vinayak P (2003) Microcantilever resonance-based DNA detection with nanoparticle probes. Appl Phys Lett 82:3562–3564CrossRef
Metadaten
Titel
A piezoelectric micro-cantilever bio-sensor using the mass-micro-balancing technique with self-excitation
verfasst von
Yeolho Lee
Geunbae Lim
Wonkyu Moon
Publikationsdatum
01.03.2007
Verlag
Springer-Verlag
Erschienen in
Microsystem Technologies / Ausgabe 5-6/2007
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-006-0216-x

Weitere Artikel der Ausgabe 5-6/2007

Microsystem Technologies 5-6/2007 Zur Ausgabe

Neuer Inhalt